Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 198
Filtrar
1.
Am J Cardiol ; 221: 19-28, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38583700

RESUMO

Cardiogenic shock after acute myocardial infarction (AMI-CS) carries significant mortality despite advances in revascularization and mechanical circulatory support. We sought to identify the process-based and structural characteristics of centers with lower mortality in AMI-CS. We analyzed 16,337 AMI-CS cases across 440 centers enrolled in the National Cardiovascular Data Registry's Chest Pain-MI Registry, a retrospective cohort database, between January 1, 2015, and December 31, 2018. Centers were stratified across tertiles of risk-adjusted in-hospital mortality rate (RAMR) for comparison. Risk-adjusted multivariable logistic regression was also performed to identify hospital-level characteristics associated with decreased mortality. The median participant age was 66 (interquartile range 57 to 75) years, and 33.0% (n = 5,390) were women. The median RAMR was 33.4% (interquartile range 26.0% to 40.0%) and ranged from 26.9% to 50.2% across tertiles. Even after risk adjustment, lower-RAMR centers saw patients with fewer co-morbidities. Lower-RAMR centers performed more revascularization (92.8% vs 90.6% vs 85.9%, p <0.001) and demonstrated better adherence to associated process measures. Left ventricular assist device capability (odds ratio [OR] 0.78 [0.67 to 0.92], p = 0.002), more frequent revascularization (OR 0.93 [0.88 to 0.98], p = 0.006), and higher AMI-CS volume (OR 0.95 [0.91 to 0.99], p = 0.009) were associated with lower in-hospital mortality. However, several such characteristics were not more frequently observed at low-RAMR centers, despite potentially reflecting greater institutional experience or resources. This may reflect the heterogeneity of AMI-CS even after risk adjustment. In conclusion, low-RAMR centers do not necessarily exhibit factors associated with decreased mortality in AMI-CS, which may reflect the challenges in performing outcomes research in this complex population.

2.
JACC Cardiovasc Interv ; 17(4): 505-515, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38340102

RESUMO

BACKGROUND: A single, multitiered valve center designation has been proposed to publicly identify centers with expertise for all valve therapies. The correlation between transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (MTEER) procedures is unknown. OBJECTIVES: The authors sought to examine the relationship between site-level volumes and outcomes for TAVR and MTEER. We further explored variability between sites for MTEER outcomes. METHODS: Using the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) national registry, TAVR and MTEER procedures at sites offering both therapies from 2013 to 2022 were examined. Sites were ranked into deciles of adjusted in-hospital and 30-day outcomes separately for TAVR and MTEER and compared. Stepwise, hierarchical multivariable models were constructed for MTEER outcomes, and the median OR was calculated. RESULTS: Between 2013 and 2022, 384,394 TAVRs and 53,274 MTEERs (median annualized volumes: 93.6 and 18.8, respectively) were performed across 453 U.S. sites. Annualized TAVR and MTEER volumes were moderately correlated (r = 0.48; P < 0.001). After adjustment, 14.3% of sites had the same decile rank for TAVR and MTEER 30-day composite outcome, 50.6% were within 2 decile ranks; 35% had more discordant outcomes for the 2 procedures (P = 0.0005). For MTEER procedures, the median OR for the 30-day composite outcome was 1.57 (95% CI: 1.51-1.64), indicating a 57% variability in outcome by site. CONCLUSIONS: There is modest correlation between hospital-level volumes for TAVR and MTEER but low interprocedural correlation of outcomes. For similar patients, site-level variability for mortality/morbidity following MTEER was high. Factors influencing outcomes and "centers of excellence" as a whole may differ for TAVR and MTEER.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Estados Unidos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Sistema de Registros , Hospitais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
3.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38235547

RESUMO

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Sarcopenia , Substituição da Valva Aórtica Transcateter , Humanos , Sarcopenia/diagnóstico por imagem , Sarcopenia/complicações , Fragilidade/diagnóstico , Fragilidade/complicações , Resultado do Tratamento , Força da Mão , Estudos Transversais , Medição de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Composição Corporal , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
5.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37503662

RESUMO

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Assuntos
Estenose da Valva Aórtica , Cardiomiopatias , Disfunção Cognitiva , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Estudos Prospectivos , Depressão/diagnóstico , Depressão/epidemiologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia , Assistência Centrada no Paciente , Cardiomiopatias/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
7.
J Am Heart Assoc ; 12(13): e029542, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37345820

RESUMO

Background Studies in mice and small patient subsets implicate metabolic dysfunction in cardiac remodeling in aortic stenosis, but no large comprehensive studies of human metabolism in aortic stenosis with long-term follow-up and characterization currently exist. Methods and Results Within a multicenter prospective cohort study, we used principal components analysis to summarize 12 echocardiographic measures of left ventricular structure and function pre-transcatheter aortic valve implantation in 519 subjects (derivation). We used least absolute shrinkage and selection operator regression across 221 metabolites to define metabolic signatures for each structural pattern and measured their relation to death and multimorbidity in the original cohort and up to 2 validation cohorts (N=543 for overall validation). In the derivation cohort (519 individuals; median age, 84 years, 45% women, 95% White individuals), we identified 3 axes of left ventricular remodeling, broadly specifying systolic function, diastolic function, and chamber volumes. Metabolite signatures of each axis specified both known and novel pathways in hypertrophy and cardiac dysfunction. Over a median of 3.1 years (205 deaths), a metabolite score for diastolic function was independently associated with post-transcatheter aortic valve implantation death (adjusted hazard ratio per 1 SD increase in score, 1.54 [95% CI, 1.25-1.90]; P<0.001), with similar effects in each validation cohort. This metabolite score of diastolic function was simultaneously associated with measures of multimorbidity, suggesting a metabolic link between cardiac and noncardiac state in aortic stenosis. Conclusions Metabolite profiles of cardiac structure identify individuals at high risk for death following transcatheter aortic valve implantation and concurrent multimorbidity. These results call for efforts to address potentially reversible metabolic biology associated with risk to optimize post-transcatheter aortic valve implantation recovery, rehabilitation, and survival.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Animais , Camundongos , Idoso de 80 Anos ou mais , Masculino , Multimorbidade , Estudos Prospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Função Ventricular Esquerda
9.
ASAIO J ; 68(12): 1470-1474, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36469446

RESUMO

The importance of medical therapy to ameliorate the incidence and impact of left ventricular assistance device-related gastrointestinal bleeding has been highlighted recently with several single-center studies. Electronic databases were searched for studies that compared the incidence of gastrointestinal bleeding for those people on left ventricular assist support with and without angiotensin II inhibition. Angiotensin II inhibition was associated with a lower incidence of gastrointestinal bleeding (pooled RR 0.58, 95% confidence interval (CI): 0.34-0.98; p = 0.04], with a trend toward toward lower incidence with arteriovenous malformation-associated gastrointestinal bleeding (pooled RR 0.50, 95% CI: 0.25-1.03; p = 0.06).


Assuntos
Malformações Arteriovenosas , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Angiotensina II , Estudos Retrospectivos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Malformações Arteriovenosas/complicações , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia
10.
Innovations (Phila) ; 17(6): 482-490, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36317252

RESUMO

OBJECTIVE: Surgical aortic valve replacement (SAVR) has been the standard of care for severe aortic stenosis. In 2019, annual transcatheter aortic valve replacement (TAVR) implantations surpassed SAVR. We compared in-hospital costs and outcomes between these two procedures. METHODS: A single-center retrospective review was performed of patients who underwent isolated SAVR or TAVR from October 2013 to December 2019. Baseline patient characteristics, operating room (OR) time, intensive care unit (ICU) length of stay (LOS), total LOS, cumulative cost, and complication rates were collected. Propensity matching was performed to identify differences in costs and outcomes between comparable groups. RESULTS: There were 515 patients who met inclusion criteria. TAVR was performed in 402 patients, while SAVR was performed in 113. Propensity matching resulted in 82 matched pairs. The SAVR cohort more frequently spent >1 day in the ICU, had longer total hospital LOS, longer OR time, and higher hospitalization cost. However, TAVR was associated with higher mean OR cost and higher valve cost. The cumulative index admission costs were not significantly different between groups. TAVR patients had less postoperative atrial fibrillation but more frequent pacemaker placement. One-year mortality was similar between SAVR (2.4%) and TAVR (3.8%), but 3-year (5.8% vs 19.2%) and 5-year (5.8% vs 37.2%) mortality favored SAVR. CONCLUSIONS: In propensity-matched groups, TAVR was associated with shorter ICU and hospital LOS and OR times but increased permanent pacemaker rates. In addition, while 1-year survival was similar between groups, SAVR had significantly improved 3-year and 5-year survival.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Custos Hospitalares , Fatores de Risco
11.
Innovations (Phila) ; 17(5): 401-408, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36217748

RESUMO

OBJECTIVE: Monitored anesthesia care (MAC) has been increasingly used in lieu of general anesthesia (GA) for transcatheter aortic valve replacement (TAVR). We sought to compare outcomes and in-hospital costs between MAC and GA for TAVR at a Veterans Affairs Medical Center. METHODS: A single-center retrospective review was performed of 349 patients who underwent transfemoral TAVR (MAC, n = 244 vs GA, n = 105) from January 2014 to December 2019. Baseline patient characteristics, operating room (OR) time, intensive care unit (ICU) length of stay (LOS), and cost, total LOS, hospital cost, total cost, and complication rates were collected. Propensity matching was performed and resulted in 83 matched pairs. RESULTS: In the unmatched TAVR cohort, MAC TAVR was associated with reduced OR time (146 vs 198 min, P < 0.001), ICU LOS (1.4 vs 1.8 days, P < 0.001), total hospital LOS (3.4 vs 5.4 days, P < 0.001), and lower index total cost ($81,300 vs $85,400, P = 0.010). After propensity matching, MAC TAVR patients had reduced OR time (146 vs 196 min, P < 0.05), ICU LOS (1.2 vs 1.7 days, P = 0.006), total LOS (3.5 vs 5.1 days, P = 0.001), and 180-day mortality (2.4% vs 12%, P < 0.03). There was no difference in total hospitalization cost or total cost. CONCLUSIONS: In propensity-matched groups, TAVR utilizing MAC is associated with improved OR time efficiency, decreased LOS, and a reduction in 180-day mortality but no significant difference in cost.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Anestesia Geral/métodos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Valva Aórtica/cirurgia
12.
JACC Cardiovasc Interv ; 15(18): 1837-1848, 2022 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-36137687

RESUMO

BACKGROUND: Low ejection fraction (EF) and low flow as determined by an echocardiographic stroke volume index (SVi) <35 mL/m2 are associated with low transvalvular gradients and increased mortality in both severe aortic stenosis (AS) and post-transcatheter aortic valve replacement (TAVR). Absence of an elevated echocardiographic transaortic gradient post-TAVR is considered a marker of procedural success despite the absence of data on its impact on mortality. OBJECTIVES: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF. METHODS: In a multicenter retrospective registry of patients undergoing TAVR, Cox models with regression splines explored the relationship between invasive and echocardiographic gradients post-TAVR with 2-year mortality. An invasive gradient <5 mm Hg was considered low, between ≥5 and <10 mm Hg was considered intermediate, and ≥10 mm Hg was considered high. An echocardiographic gradient <10 mm Hg was considered low, ≥10 and <20 mm Hg was considered intermediate, and ≥20 mm Hg was considered high. RESULTS: Higher mortality occurred in low echocardiographic gradients at discharge relative to intermediate gradients (P < 0.001), and low gradient was associated with lower EF and echocardiographic SVi (P < 0.001 and P < 0.008, respectively). Lower mortality occurred in low invasive gradients relative to intermediate gradients (P = 0.012) with no difference in EF and echocardiographic SVi between groups (P = 0.089 and P = 0.947, respectively). There were insufficient observations to determine the impact of high echocardiographic and invasive gradients on mortality. CONCLUSIONS: In this large retrospective analysis, the impact of transaortic gradients on mortality after TAVR was not linear and complex, showing opposite results among echocardiographic and invasive measurements in low-gradient patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento
13.
J Am Heart Assoc ; 11(19): e026529, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36172966

RESUMO

Background Global longitudinal strain (GLS) is a sensitive measure of left ventricular function and a risk marker in severe aortic stenosis. We sought to determine whether biomarkers of cardiac damage (cardiac troponin) and stress (NT-proBNP [N-terminal pro-B-type natriuretic peptide]) could complement GLS to identify patients with severe aortic stenosis at highest risk. Methods and Results From a multicenter prospective cohort of patients with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation, we measured absolute GLS (aGLS), cardiac troponin, and NT-proBNP at baseline in 499 patients. Left ventricular ejection fraction <50% was observed in 19% and impaired GLS (aGLS <15%) in 38%. Elevations in cardiac troponin and NT-proBNP were present in 79% and 89% of those with impaired GLS, respectively, as compared with 63% and 60% of those with normal GLS, respectively (P<0.001 for each). aGLS <15% was associated with increased mortality in univariable analysis (P=0.009), but, in a model with both biomarkers, aGLS, and clinical covariates included, aGLS was not associated with mortality; elevation in each biomarker was associated with an increased hazard of mortality (adjusted hazard ratio, >2; P≤0.002 for each) when the other biomarker was elevated, but not when the other biomarker was normal (interaction P=0.015). Conclusions Among patients with symptomatic severe aortic stenosis undergoing transcatheter aortic valve implantation, elevations in circulating cardiac troponin and NT-proBNP are more common as GLS worsens. Biomarkers of cardiac damage and stress are independently associated with mortality after transcatheter aortic valve implantation, whereas GLS is not. These findings may have implications for risk stratification of asymptomatic patients to determine optimal timing of valve replacement.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Biomarcadores , Humanos , Peptídeo Natriurético Encefálico , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Troponina , Função Ventricular Esquerda
14.
J Am Heart Assoc ; 11(13): e024342, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35766258

RESUMO

Background P2Y12 inhibitor medications are critical following percutaneous coronary intervention (PCI); however, adherence remains suboptimal. Our objective was to assess the effectiveness of a multifaceted intervention to improve P2Y12 inhibitor adherence following PCI. Methods and Results This was a modified stepped wedge trial of 52 eligible hospitals, of which 15 were randomly selected and agreed to participate (29 hospitals declined, and 8 eligible hospitals were not contacted). At each intervention hospital, patient recruitment occurred for 6 months and enrolled patients were followed up for 1 year after PCI. Three control groups were used: patients at intervention hospitals undergoing PCI (1) before the intervention period (preintervention); (2) after the intervention period (postintervention); or (3) at the 8 hospitals not contacted (concurrent controls). The intervention consisted of 4 components: (1) P2Y12 inhibitor delivered to patients' bedside after PCI; (2) education on importance of P2Y12 inhibitors; (3) automated reminder telephone calls to refill medication; and (4) outreach to patients if they delayed refilling P2Y12 inhibitor. The primary outcomes were as follows: (1) proportion of patients with delays filling P2Y12 inhibitor at hospital discharge and (2) proportion of patients who were adherent in the year after PCI using pharmacy refill data. Primary analysis compared intervention with preintervention control patients. There were 1377 (intent-to-treat) potentially eligible patients, of whom 803 (per protocol) were approached at intervention sites versus 5910 preintervention, 2807 postintervention, and 4736 concurrent control patients. In the intent-to-treat analysis, intervention patients were less likely to delay filling P2Y12 at hospital discharge (-3.4%; 98.3% CI, -1.2% to -5.6%) and more likely to be adherent to P2Y12 (4.1%; 98.3% CI, 1.0%-7.1%) at 1 year, but had more clinical events (3.2%; 98.3% CI, 2.3%-4.1%) driven by repeated PCI compared with preintervention patients. In post hoc analysis looking at myocardial infarction, stroke, and death, intervention patients had lower event rates compared with preintervention patients (-1.7%; 98.3% CI, -2.3% to -1.1%). Conclusions A 4-component intervention targeting P2Y12 inhibitor adherence was difficult to implement. The intervention produced mixed results. It improved P2Y12 adherence, but there was also an increase in repeat PCI. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01609842.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Resultado do Tratamento
15.
J Invasive Cardiol ; 34(6): E484-E485, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35652713

RESUMO

A 60-year-old female underwent a left ventricular assist device implantation during which a 1-mm Gore-Tex sheet was used to cover the device and outflow graft to prevent future sternal re-entry injury. Seven years later, she developed low-flow alarms with a pattern of gradual decline in flow and power suggestive of outflow graft obstruction. After a discussion with the multidisciplinary team, percutaneous stenting of the outflow graft was pursued.


Assuntos
Coração Auxiliar , Obstrução do Fluxo Ventricular Externo , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Pessoa de Meia-Idade , Politetrafluoretileno , Stents/efeitos adversos
16.
J Am Heart Assoc ; 11(7): e023466, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35301869

RESUMO

Background Left ventricular hypertrophy (LVH) is associated with increased mortality risk and rehospitalization after transcatheter aortic valve replacement among those with severe aortic stenosis. Whether cardiac troponin (cTnT) and NT-proBNP (N-terminal pro-B-type natriuretic peptide) risk stratify patients with aortic stenosis and without LVH is unknown. Methods and Results In a multicenter prospective registry of 923 patients with severe aortic stenosis undergoing transcatheter aortic valve replacement, we included 674 with core-laboratory-measured LV mass index, cTnT, and NT-proBNP. LVH was defined by sex-specific guideline cut-offs and elevated biomarker levels were based on age and sex cut-offs. Adjusted Cox proportional hazards models evaluated associations between LVH and biomarkers and all-cause death out to 5 years. Elevated cTnT and NT-proBNP were present in 82% and 86% of patients with moderate/severe LVH, respectively, as compared with 66% and 69% of patients with no/mild LVH, respectively (P<0.001 for each). After adjustment, compared with no/mild LVH, moderate/severe LVH was associated with an increased hazard of mortality (adjusted hazard ratio [aHR], 1.34; 95% CI 1.01-1.77, P=0.043). cTnT and NT-proBNP each risk stratified patients with moderate/severe LVH (P<0.05). In a model with both biomarkers and LVH included, elevated cTnT (aHR, 2.08; 95% CI 1.45-3.00, P<0.001) and elevated NT-proBNP (aHR, 1.46; 95% CI 1.00-2.11, P=0.049) were each associated with increased mortality risk, whereas moderate/severe LVH was not (P=0.15). Conclusions Elevations in circulating cTnT and NT-proBNP are more common as LVH becomes more pronounced but are also observed in those with no/minimal LVH. As measures of maladaptive remodeling and cardiac injury, cTnT and NT-proBNP predict post-transcatheter aortic valve replacement mortality better than LV mass index. These findings may have important implications for risk stratification and treatment of patients with aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Hipertrofia Ventricular Esquerda , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Biomarcadores , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Fatores de Risco
17.
Innovations (Phila) ; 16(6): 517-522, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34488482

RESUMO

OBJECTIVE: Elevated red blood cell distribution width (RDW) level has been shown to be associated with poor outcomes in patients with cardiovascular disease. Limited data are available regarding the prognostic value of RDW in transcatheter aortic valve replacement (TAVR) patients. Therefore, we aimed to investigate the impact of RDW variation on outcomes of TAVR patients. METHODS: From March 20, 2012, to February 20, 2020, the pre-TAVR RDW levels of 1,163 consecutive TAVR patients were examined. Receiver operating curves were set to define the most accurate cut-point, which was subsequently validated in our validation set. Associations of RDW levels with early and long-term outcomes were investigated. RESULTS: A total of 988 patients were eligible for the analysis. Patients with 30-day, 1-year, and 7-year mortality had significantly higher pre-TAVR RDW levels (15.8% [12.9-19.1] vs 14.7% [11.6-26.3], P = 0.01; 16% [12.3-26.3] vs 14.7% [11.6-24.3], P < 0.001; 15.6% [12.3-26.3] vs 14.6% [11.6-24.3], P < 0.001, respectively). A RDW of 14.5% was found as the most sensitive and specific cut-point for mortality at 1 and 7 years (HR = 2.6, 95% CI: 1.6-4.2, P < 0.001; HR = 1.8, 95% CI: 1.3-2.4, P < 0.001), with mortality of 22% versus 10% at 1 year (P < 0.001) and 37% versus 27% at 7 years (P < 0.001) in patients with RDW ≥14.5% versus those with RDW <14.5%. CONCLUSIONS: RDW is an important prognostic factor in TAVR patients. A RDW level higher than 14.5% is significantly associated with post-TAVR early and late mortality. RDW levels should be incorporated into current risk assessment models as an additional variable to predict post-TAVR outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Eritrócitos , Humanos , Prognóstico , Fatores de Risco , Resultado do Tratamento
18.
J Card Surg ; 36(11): 4024-4029, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34365660

RESUMO

INTRODUCTION: Limited data are available about the outcomes of transcatheter mitral valve replacement (TMVR) using transseptal approach in patients with prior mitral valve repair (valve-in-ring) or replacement (valve-in-valve) (TMViVR) and on modes of the prior surgical valve failures. We report our tertiary center TMVR experience in high surgical risk patients with prior mitral valve repair or replacement. METHODS: From December 2016 to January 2020, patients with symptomatic severe mitral valve stenosis and/or insufficiency at increased redo surgical risk were included. TMViVR was performed off-label with Sapien S3 valve (Edwards Lifesciences). Patients were followed within 30-days and 1-year from the procedure. RESULTS: Twenty-seven patients underwent transcatheter mitral valve-in-valve (n = 21) or valve-in-ring (n = 6) replacement. Mean ± SD age was 71.8 ± 11 years with Society of Thoracic Surgeons' calculated mortality 7.1 ± 4.6%. The etiology of valve failure was stenosis in 17 (63%) patients, insufficiency in 4 (14.8%) patients, and both in 6 (22.2%) patients. TMViVR technical success was 100% in all patients. Left ventricular outflow track (LVOT) obstruction was observed in only one (3.7%) patient. Zero patients had moderate or severe central mitral valve regurgitation or paravalvular leak. All patients had symptomatic improvement at 30 days. The mean transmitral diastolic pressure gradient decreased from 14.1 ± 4.6 to 6.9 ± 4.6 mm Hg (p < .001) at 30 days. The one patient with LOVT obstruction required readmission at 5-months. One-year survival was 95%. At 1-year mean gradients remained lower than the baseline (7.0 ± 3.0 vs. 12.4 ± 4.0, p = .002). CONCLUSIONS: Transcatheter mitral valve-in-valve and valve-in-ring replacement is feasible and safe. The improvement in mitral valve hemodynamics appears to be durable.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Humanos , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Instrumentos Cirúrgicos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...