Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(4): 041003, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37566859

RESUMO

We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment, which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of 5.9 ton. During the (1.09±0.03) ton yr exposure used for this search, the intrinsic ^{85}Kr and ^{222}Rn concentrations in the liquid target are reduced to unprecedentedly low levels, giving an electronic recoil background rate of (15.8±1.3) events/ton yr keV in the region of interest. A blind analysis of nuclear recoil events with energies between 3.3 and 60.5 keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of 2.58×10^{-47} cm^{2} for a WIMP mass of 28 GeV/c^{2} at 90% confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.

2.
Phys Rev Lett ; 130(26): 261002, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450817

RESUMO

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from multiply interacting massive particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This Letter places strong constraints on spin-independent interactions of dark matter particles with a mass between 1×10^{12} and 2×10^{17} GeV/c^{2}. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross sections for dark matter particles with masses close to the Planck scale.

3.
Phys Rev Lett ; 129(16): 161805, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306777

RESUMO

We report on a blinded analysis of low-energy electronic recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 ton liquid xenon target reduced the background in the (1, 30) keV search region to (15.8±1.3) events/(ton×year×keV), the lowest ever achieved in a dark matter detector and ∼5 times lower than in XENON1T. With an exposure of 1.16 ton-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

4.
Eur Phys J C Part Fields ; 82(7): 599, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35821975

RESUMO

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222 Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ( ∼ 17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222 Rn activity concentration in XENONnT is determined to be 4.2 ( - 0.7 + 0.5 )  µ Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

5.
Eur J Clin Nutr ; 59(3): 325-33, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15508014

RESUMO

OBJECTIVE: To examine the effect of a diet containing a novel legume food ingredient, Australian sweet lupin (Lupinus angustifolius) kernel fibre (LKFibre), compared to a control diet without the addition of LKFibre, on serum lipids in men. DESIGN: Randomized crossover dietary intervention study. SETTING: Melbourne, Australia--Free-living men. SUBJECTS: A total of 38 healthy males between the ages of 24 and 64 y completed the intervention. INTERVENTION: Subjects consumed an LKFibre and a control diet for 1 month each. Both diets had the same background menus with seven additional experimental foods that either contained LKFibre or did not. Depending on energy intake, the LKFibre diet was designed to contain an additional 17 to 30 g/day fibre beyond that of the control diet. RESULTS: Compared to the control diet, the LKFibre diet reduced total cholesterol (TC) (mean+/-s.e.m.; 4.5+/-1.7%; P=0.001), low-density lipoprotein cholesterol (LDL-C) (5.4+/-2.2%; P=0.001), TC: high-density lipoprotein cholesterol (HDL-C) (3.0+/-2.0%; P=0.006) and LDL-C:HDL-C (3.8+/-2.6%; P=0.003). No effects on HDL-C, triacylglycerols, glucose or insulin were observed. CONCLUSIONS: Addition of LKFibre to the diet provided favourable changes to some serum lipid measures in men, which, combined with its high palatability, suggest this novel ingredient may be useful in the dietary reduction of coronary heart disease risk.


Assuntos
Colesterol/sangue , Fibras na Dieta/administração & dosagem , Hipercolesterolemia/tratamento farmacológico , Lupinus/química , Fitoterapia , Adulto , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Doença das Coronárias/sangue , Doença das Coronárias/prevenção & controle , Estudos Cross-Over , Fibras na Dieta/uso terapêutico , Humanos , Hipercolesterolemia/sangue , Masculino , Pessoa de Meia-Idade , Triglicerídeos/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...