Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Breast ; 50: 11-18, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31958661

RESUMO

BACKGROUND: Patients with breast cancer (BC) show strong interest in complementary and alternative medicine (CAM), particularly for adverse effects of adjuvant endocrine treatment - e.g., with letrozole. Letrozole often induces myalgia/limb pain and arthralgia, with potential noncompliance and treatment termination. This analysis investigated whether CAM before aromatase inhibitor (AI) therapy is associated with pain development and the intensity of AI-induced musculoskeletal syndrome (AIMSS) during the first year of treatment. PATIENTS AND METHODS: The multicenter phase IV PreFace study evaluated letrozole therapy in postmenopausal, hormone receptor-positive patients with early BC. Patients were asked about CAM use before, 6 months after, and 12 months after treatment started. They recorded pain every month for 1 year in a diary including questions about pain and numeric pain rating scales. Data were analyzed for patients who provided pain information for all time points. RESULTS: Of 1396 patients included, 901 (64.5%) had used CAM before AI treatment. Throughout the observation period, patients with CAM before AI treatment had higher pain values, for both myalgia/limb pain and arthralgia, than non-users. Pain increased significantly in both groups over time, with the largest increase during the first 6 months. No significant difference of pain increase was noted regarding CAM use. CONCLUSIONS: CAM use does not prevent or improve the development of AIMSS. Pain intensity was generally greater in the CAM group. Therefore, because of the risk of non-compliance and treatment discontinuation due to the development of higher pain levels, special attention must be paid to patient education and aftercare in these patients.


Assuntos
Inibidores da Aromatase/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Terapias Complementares , Letrozol/efeitos adversos , Dor Musculoesquelética/induzido quimicamente , Idoso , Artralgia/induzido quimicamente , Feminino , Alemanha/epidemiologia , Humanos , Pessoa de Meia-Idade , Mialgia/induzido quimicamente , Pós-Menopausa
2.
Ann Oncol ; 29(1): 186-192, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29045642

RESUMO

Background: Patients' compliance and persistence with endocrine treatment has a significant effect on the prognosis in early breast cancer (EBC). The purpose of this analysis was to identify possible reasons for non-persistence, defined as premature cessation of therapy, on the basis of patient and tumor characteristics in individuals receiving adjuvant treatment with letrozole. Patients and methods: The EvAluate-TM study is a prospective, multicenter, noninterventional study in which treatment with the aromatase inhibitor letrozole was evaluated in postmenopausal women with hormone receptor-positive EBC in the early therapy phase. Treatment persistence was evaluated at two pre-specified study visits after 6 and 12 months. As a measure of early therapy persistence the time from the start to the end of treatment (TTEOT) was analyzed. Cox regression analyses were carried out to identify patient characteristics and tumor characteristics predicting TTEOT. Results: Out of the total population of 3941 patients with EBC, 540 (13.7%) events involving treatment cessation unrelated to disease progression were observed. This was due to drug-related toxicity in the majority of cases (73.5%). Persistence rates were 92.2%, 86.9%, and 86.3% after 6, 12, and 15 months, respectively. The main factors influencing premature treatment discontinuation were older age [hazard ratio (HR) 1.02/year], comorbidities (HR 1.06 per comorbidity), low body mass index, and lower tumor grade (HR 0.85 per grade unit). Conclusion: These results support the view that older, multimorbid patients with low tumor grade and low body mass index are at the greatest risk for treatment discontinuation and might benefit from compliance and support programs.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Letrozol/administração & dosagem , Adesão à Medicação , Idoso , Antineoplásicos/administração & dosagem , Inibidores da Aromatase/administração & dosagem , Neoplasias da Mama/patologia , Neoplasias da Mama/psicologia , Quimioterapia Adjuvante , Feminino , Humanos , Pessoa de Meia-Idade , Pós-Menopausa , Estudos Prospectivos
3.
Geburtshilfe Frauenheilkd ; 77(2): 169-175, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28331239

RESUMO

Introduction The placement of intramammary marker clips has proven to be helpful for tumor localization in patients undergoing neoadjuvant chemotherapy and breast-conserving surgery. The purpose of our study was to investigate the feasibility of using a clip marker system for breast cancer localization and its influence on the imaging assessment of treatment responses after neoadjuvant chemotherapy. Patients and Methods Between March and June 2015, a total of 25 patients (n = 25), with a suspicion of invasive breast cancer with diameters of at least 2 cm (cT2), underwent preoperative sonographically guided core needle biopsy using a single-use breast biopsy system (HistoCore™) and intramammary clip marking using a directly adapted clip system based on the established O-Twist Marker™, before their scheduled preoperative neoadjuvant chemotherapy. Localization of the intramammary marker clip was controlled by sonography and digital breast tomosynthesis. Results Sonography detected no dislocation of intrammammary marker clips in 20 of 25 patients (80 %), while digital breast tomosynthesis showed accurate placement without dislocation in 24 patients (96 %) (p < 0.05). There was no evidence of significant clip migration during preoperative follow-up imaging after neoadjuvant chemotherapy. No complication related to the clip marking was noted and there was no difficulty in evaluating the treatment response to neoadjuvant chemotherapy. Among the breast-conserving surgeries performed, no cases were identified in which intraoperative loss of the marker clip had occurred. Conclusion Our study underscores the importance of intramammary marking clip systems before neoadjuvant chemotherapy. Placement of marker clips is advised to facilitate accurate tumor bed localization. With regard to digital breast tomosynthesis, its development continues to improve the quality of diagnostics and the therapy of breast cancer particularly for small breast cancer tumors or in neoadjuvant chemotherapy setting.

4.
Geburtshilfe Frauenheilkd ; 75(1): 72-76, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25684789

RESUMO

Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

5.
Geburtshilfe Frauenheilkd ; 74(12): 1137-1143, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25568468

RESUMO

Introduction: The EvaluateTM study (Evaluation of therapy management and patient compliance in postmenopausal hormone receptor-positive breast cancer patients receiving letrozole treatment) is a prospective, non-interventional study for the assessment of therapy management and compliance in the routine care of postmenopausal women with invasive hormone receptor-positive breast cancer receiving letrozole. The parameters for inclusion in the study are presented and discussed here. Material and Methods: Between January 2008 and December 2009 a total of 5045 patients in 310 study centers were recruited to the EvaluateTM study. Inclusion criteria were hormone receptor-positive breast cancer and adjuvant treatment or metastasis. 373 patients were excluded from the analysis for various reasons. Results: A total of 4420 patients receiving adjuvant treatment and 252 patients with metastasis receiving palliative treatment were included in the study. For 4181 patients receiving adjuvant treatment, treatment with the aromatase inhibitor letrozole commenced immediately after surgery (upfront). Two hundred patients had initially received tamoxifen and started aromatase inhibitor treatment with letrozole at 1-5 years after diagnosis (switch), und 39 patients only commenced letrozole treatment 5-10 years after diagnosis (extended endocrine therapy). Patient and tumor characteristics were within expected ranges, as were comorbidities and concurrent medication. Conclusion: The data from the EvaluateTM study will offer a good overview of therapy management in the routine care of postmenopausal women with hormone receptor-positive breast cancer. Planned analyses will look at therapy compliance and patient satisfaction with how information is conveyed and the contents of the conveyed information.

6.
Geburtshilfe Frauenheilkd ; 73(11): 1135-1138, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24771900

RESUMO

Introduction: A newly adapted clip system for intramammary marking during ultrasound-guided core needle biopsy for suspicion of breast cancer is described and evaluated here. Material and Method: Fifty patients with suspicion of breast cancer (cT2) had ultrasound-guided core needle biopsy using a newly adapted clip marker system (HistoCore™ and O-Twist Marker™). Subsequently, ultrasound follow-up and tomosynthesis scans were done to determine the location of the marker clips. Results: No dislocation of the marker clip was detected on ultrasound in 45 of 50 patients (90 %), and 5 patients (10 %) had a maximum dislocation of 5 mm along the x-, y- or z-axis. Tomosynthesis scans demonstrated precise placement without dislocation of the clip markers in 48 patients (96 %); 2 patients (4 %) had a maximum dislocation of 3 mm along the x-, y- or z-axis. Conclusion: The newly developed clip marker system, a combination of a single-use breast biopsy needle and a precise, length-adapted intramammary marker clip, represents a further improvement in oncological therapy. This is of particular importance for patients requiring subsequent neoadjuvant chemotherapy, as in cases with complete tumour remission, there is no target point for preoperative, ultrasound-guided wire marking.

7.
Geburtshilfe Frauenheilkd ; 73(12): 1228-1235, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24771903

RESUMO

Several advancements over the last decade have triggered the developments in the field of breast cancer risk research. One of them is the availability of the human genome sequence along with cheap genotyping possibilities. Another is the globalization of research, which has led to the growth of research collaboration into large international consortia that facilitate the pooling of clinical and genotype data of hundreds of thousands of patients and healthy control individuals. This review concerns with the recent developments in breast cancer risk research and focuses on the discovery of new genetic breast cancer risk factors and their meaning in the context of established non-genetic risk factors. Finally the clinical application is highly dependent on the accuracy of breast cancer risk prediction models, not only for all breast cancer patients, but also for molecular subtypes, preferably for those which are associated with an unfavorable prognosis. Recently risk prediction incorporates all possible risk factors, which include epidemiological risk factors, mammographic density and genetic risk factors.

8.
Geburtshilfe Frauenheilkd ; 73(5): 422-427, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24771921

RESUMO

Aim: This prospective clinical study aimed to evaluate whether it would be possible to reduce the rate of re-excisions using CMOS technology, a specimen radiography system (SRS) or digital breast tomosynthesis (DBT) compared to a conventional full field digital mammography (FFDM) system. Material and Method: Between 12/2012 and 2/2013 50 patients were diagnosed with invasive breast cancer (BI-RADS™ 5). After histological verification, all patients underwent breast-conserving therapy with intraoperative imaging using 4 different systems and differing magnifications: 1. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm; 2. BioVision™ (Bioptics, Tucson, AZ, USA), CMOS technology, photodiode array, flat panel, tungsten source, focus 0.05, resolution 50 µm pixel pitch, 12 lp/mm; 3. the Trident™ specimen radiography system (SRS) (Hologic, Bedford, MA, USA), amorphous selenium, tungsten source, focus 0.05, resolution 70 µm pixel pitch, 7.1 lp/mm; 4. tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm, angular range 50 degrees, 25 projections, scan time > 20 s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiographs were prospectively shown to 3 radiologists. Results: Of the 50 patients with histologically proven breast cancer (BI-RADS™ 6), 39 patients required no further surgical therapy (re-excision) after breast-conserving surgery. A retrospective analysis (n = 11) showed a significant (p < 0.05) increase of sensitivity with the BioVision™, the Trident™ and tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 2.0 or 1.0 : 1.0 (tomosynthesis) (2.6, 3.3 or 3.6 %), i.e. re-excision would not have been necessary in 2, 3 or 4 patients, respectively, compared to findings obtained with a standard magnification of 1.0 : 1.0. Conclusion: The sensitivity of the BioVision™, the Trident™ and tomosynthesis was significantly (p < 0.05) higher and the rate of re-excisions was reduced compared to FFDM using a conventional detector at a magnification of 2.0 but without zooming.

9.
Eur J Surg Oncol ; 38(1): 44-51, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22032911

RESUMO

BACKGROUND: Re-operations after breast conserving surgery (BCS) are necessary, when specimen margins are not free of breast cancer cells. This study explored the accuracy of preoperative tumour size assessment and its influence on the rate of re-excisions and mastectomies. METHODS: The study included 1591 patients with invasive breast cancer, who were planned for BCS. Patient, staging and tumor characteristics were evaluated concerning their influence on re-excision and mastectomy rates. Patient and tumor characteristics comprised histopathological tumour size, HER2 status, multifocality, in situ component, grading (G), nodal status and hormone receptor (HR) status. Staging characteristics included deviation from pathological tumour size as measured by clinical examination, sonography and mammography. RESULTS: In 1316 patients (83%) sufficient treatment was possible with one operation. 275 patients (17%) had to undergo at least one further surgery as a result of positive specimen margins. In 138 patients (9%) mastectomy was ultimately necessary. In patients with a positive HER2 status, a larger tumour size, underestimation by ultrasound, an in situ component and multifocality, the risk for a re-operation was about doubled. Tumour size deviation in the mammogram or the clinical tumour size assessment did not have significant influence to the re-excision rates. CONCLUSION: Tumour size and accurate presurgical assessment of the tumour size itself are independent predictors for the need of a second surgery or even a mastectomy in patients for whom a primary BCS was planned.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Mamografia , Mastectomia Segmentar , Neoplasia Residual/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Neoplasias da Mama/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Mastectomia Radical Modificada , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Período Pré-Operatório , Reoperação , Medição de Risco , Ultrassonografia Mamária
10.
Geburtshilfe Frauenheilkd ; 72(6): 532-538, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26640287

RESUMO

Aim: The aim of this prospective clinical study was to assess whether it would be possible to reduce the rate of re-excisions and improve the quality using CMOS technology or digital breast tomosynthesis (DBT) compared to a conventional FFDM system. Material and Methods: An invasive breast cancer (BI-RADS 5) was diagnosed in 200 patients in the period from 5/2011 to 1/2012. After histological verification, a breast-conserving therapy was performed with intraoperative imaging. Three different imaging systems were used: 1) Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 l/mm as the standard; 2) BioVision™ (Bioptics, Tucson, USA), flat panel photodiode array, tungsten source, focus 0.05, resolution 50 µm pixel pitch, 12 l/mm; 3) Tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 l/mm, range: 50°, 25 projections, scan time > 20 s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiograms were prospectively shown to 3 radiologists. Results: Out of a total of 200 patients with histologically confirmed breast cancer (BI-RADS 6) 156 patients required no further operative therapy (re-excision) after breast-conserving therapy. A retrospective analysis (n = 44) showed an increase in sensitivity with tomosynthesis compared to the BioVision™ (CMOS technology) and the Inspiration™ at a magnification of 1.0 : 1.0 of 8 % (p < 0.05), i.e. re-excision would not have been necessary in 16 patients with tomosynthesis. Conclusions: The sensitivity of tomosynthesis for intraoperative radiography is significantly (p < 0.05) higher compared to both CMOS technology and an FFDM system with a conventional detector. Additional studies using higher magnification, e.g. 2.0 : 1.0, but no zooming will be necessary to evaluate the method further.

11.
Geburtshilfe Frauenheilkd ; 72(5): 408-411, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-25298545

RESUMO

Purpose: Experimental study of a new system for digital 2D and 3D full-field mammography (FFDM) using a high resolution detector based on two shifts of a-Se. Material and Methods: Images were acquired using the new FFDM system Amulet® (FujiFilm, Tokio, Japan), an a-Se detector (receptor 24 × 30 cm2, pixel size 50 µm, memory depth 12 bit, spatial resolution 10 lp/mm, DQE > 0.50). Integrated in the detector is a new method for data transfer, based on optical switch technology. The object of investigation was the Wisconsin Mammographic Random Phantom, Model 152A (Radiation Measurement Inc., Middleton, WI, USA) and the same parameters and exposure data (Tungsten, 100 mAs, 30 kV) were consistently used. We acquired 3 different pairs of images in the c-c and ml planes (2D) and in the c-c and c-c planes with an angle of 4 degrees (3D). Five radiologists experienced in mammography (experience ranging from 3 months to more than 5 years) analyzed the images (monitoring) which had been randomly encoded (random generator) with regard to the recognition of details such as specks of aluminum oxide (200-740 µm), nylon fibers (0.4-1.6 mm) and round lesions/masses (diameters 5-14 mm), using special linear glasses for 3D visualization, and compared the results. Results: A total of 225 correct positive decisions could be detected: we found 222 (98.7 %) correct positive results for 2D and 3D visualization in each case. Conclusion: The results of this phantom study showed the same detection rates for both 2D and 3D imaging using full field digital mammography. Our results must be confirmed in further clinical trials.

12.
Geburtshilfe Frauenheilkd ; 71(12): 1056-1066, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25253900

RESUMO

The information available about breast cancer risk factors has increased dramatically during the last 10 years. In particular, studies of low-penetrance genes and mammographic density have improved our understanding of breast cancer risk. In addition, initial steps have been taken in investigating interactions between genes and environmental factors. This review concerns with actual data on this topic. Several genome-wide association studies (GWASs) with a case-control design, as well as large-scale validation studies, have identified and validated more than a dozen single nucleotide polymorphisms (SNPs) associated with breast cancer risk. They are located not only in or close to genes known to be involved in cancer pathogenesis, but also in genes not previously associated with breast cancer pathogenesis, or may even not be related to any genes. SNPs have also been identified that alter the lifetime risk in BRCA mutation carriers. With regard to nongenetic risk factors, studies of postmenopausal hormone replacement therapy (HRT) have revealed important information on how to weigh up the risks and benefits of HRT. Mammographic density (MD) has become an accepted and important breast cancer risk factor. Lifestyle and nutritional considerations have become an integral part of most studies of breast cancer risk, and some improvements have been made in this field as well. More than 10 years after the publication of the first breast cancer prevention studies with tamoxifen, other substances such as raloxifene and aromatase inhibitors have been investigated and have also been shown to have preventive potential. Finally, mammographic screening systems have been implemented in most Western countries during the last decade. These may be developed further by including more individualized methods of predicting the patient's breast cancer risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...