Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Mol Mutagen ; 45(1): 44-55, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15605355

RESUMO

An interlaboratory study was performed to validate an anti-CD71/flow cytometry-based technique for enumerating micronucleated reticulocytes (MN-RETs) in mouse peripheral blood. These experiments were designed to address International Workshop on Genotoxicity Test Procedures validation criteria by evaluating the degree of correspondence between MN-RET measurements generated by flow cytometry (FCM) with those obtained using traditional microscopy-based methods. In addition to these cross-methods data, flow cytometric MN-RET measurements for each blood sample were performed at two separate sites in order to evaluate the reproducibility of data between laboratories. In these studies, groups of male CD-1 mice were treated with vehicle (saline or vegetable oil), a negative control (saline or vegetable oil), or four dose levels of five known genotoxicants (clastogens: cyclophosphamide, benzo[a]pyrene, 5-fluorouracil, methotrexate; aneugen: vincristine sulfate). Exposure occurred on 3 consecutive days via intraperitoneal injection, and blood samples were obtained approximately 24 hr after the final treatment. MN-RET frequencies were determined for each sample based on the analysis of 2,000 (microscopy) and 20,000 (FCM) reticulocytes. Regardless of the method utilized, each genotoxic agent was observed to cause statistically significant increases in the frequency of MN-RETs, and each response occurred in a dose-dependent manner. Spearman's correlation coefficient (rs) for FCM versus microscopy-based MN-RET measurements (nine experiments, 252 paired measurements) was 0.740, indicating a high degree of correspondence between methods. The rs value for all flow cytometric MN-RET measurements performed at the two independent sites was 0.857 (n = 248), suggesting that the automated method is highly transferable between laboratories. Additionally, the flow cytometric system offered advantages relative to microscopy-based scoring, including a greater number of cells analyzed, much faster analysis times, and a greater degree of objectivity. Collectively, data presented in this report suggest that the overall performance of mouse peripheral blood micronucleus tests is enhanced by the use of the flow cytometric scoring procedure.


Assuntos
Citometria de Fluxo/métodos , Testes para Micronúcleos/métodos , Reticulócitos , Animais , Antígenos CD , Antígenos de Diferenciação de Linfócitos B , Benzo(a)pireno/toxicidade , Ciclofosfamida/toxicidade , Relação Dose-Resposta a Droga , Masculino , Metotrexato/toxicidade , Camundongos , Mutagênicos/toxicidade , Receptores da Transferrina , Vincristina/toxicidade
2.
Environ Mol Mutagen ; 42(3): 166-84, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14556224

RESUMO

We have isolated and characterized a stable epithelial cell line from Muta Mouse lung that is a suitable complement to the in vivo assay system. The cells are contact inhibited, forming a flat monolayer, and retain several epithelial/pulmonary characteristics. The genome is stable across more than 50 generations, with a modal chromosome number of 78. Spontaneous rates of micronuclei (19.2 +/- 1.4 per 1,000), sister chromatid exchanges (0.25 +/- 0.004 per chromosome), and chromosome aberrations ( approximately 4%) are lower than, or comparable to, other transgenic cell lines currently used in mutagenicity research. Fluorescence in situ hybridization analyses showed that 80% of cells contain three lambdagt10lacZ loci. Slot-blot analyses indicated that the average cell contains approximately 17 transgene monomers. Spontaneous mutant frequency at the lacZ transgene is stable (39.8 +/- 1.1 x 10(-5)), and the direct-acting mutagens N-ethyl-N-nitrosourea and ICR-191 yielded increases in mutant frequency of 6.3- and 3.2-fold above control, respectively. Benzo[a]pyrene (BaP) exposure increased mutant frequency more than 25-fold above control and did not require an exogenous metabolic activation mixture. Inhibition of Cyp1A1 by 5 microM alpha-naphthoflavone eliminated BaP mutagenesis. Activation and mutation induction by the heterocyclic amine 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine required a low concentration (0.05% v/v) of exogenous rat liver S9. High activity of alpha, micro, and pi glutathione-S-transferase isozymes appears to confer resistance to the cytotoxic effects of xenobiotics. The cell line is a suitable complement to the in vivo Muta Mouse assay, and provides an opportunity for routine in vitro mutagenicity testing using an endpoint that is identical to that employed in vivo.


Assuntos
Pulmão/citologia , Animais , Células Epiteliais/citologia , Óperon Lac , Camundongos , Camundongos Mutantes , Microscopia de Fluorescência , Mutação , Transgenes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...