Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Food Microbiol ; 149(3): 262-8, 2011 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-21802758

RESUMO

Escherichia coli O157:H7 attached to beef-contact surfaces found in beef fabrication facilities may serve as a source of cross-contamination. This study evaluated E. coli O157:H7 attachment, survival and growth on food-contact surfaces under simulated beef processing conditions. Stainless steel and high-density polyethylene surfaces (2×5cm) were individually suspended into each of three substrates inoculated (6log CFU/ml or g) with E. coli O157:H7 (rifampicin-resistant, six-strain composite) and then incubated (168h) statically at 4 or 15°C. The three tested soiling substrates included sterile tryptic soy broth (TSB), unsterilized beef fat-lean tissue (1:1 [wt/wt]) homogenate (10% [wt/wt] with sterile distilled water) and unsterilized ground beef. Initial adherence/attachment of E. coli O157:H7 (0.9 to 2.9log CFU/cm(2)) on stainless steel and high-density polyethylene was not affected by the type of food-contact surface but was greater (p<0.05) through ground beef. Adherent and suspended E. coli O157:H7 counts increased during storage at 15°C (168h) by 2.2 to 5.4log CFU/cm(2) and 1.0 to 2.8log CFU/ml or g, respectively. At 4°C (168h), although pathogen levels decreased slightly in the substrates, numbers of adherent cells remained constant on coupons in ground beef (2.4 to 2.5log CFU/cm(2)) and increased on coupons in TSB and fat-lean tissue homogenate by 0.9 to 1.0and 1.7 to 2.0log CFU/cm(2), respectively, suggesting further cell attachment. The results of this study indicate that E. coli O157:H7 attachment to beef-contact surfaces was influenced by the type of soiling substrate and temperature. Notably, attachment occurred not only at a temperature representative of beef fabrication areas during non-production hours (15°C), but also during cold storage (4°C) temperatures, thus, rendering the design of more effective sanitation programs necessary.


Assuntos
Biofilmes/crescimento & desenvolvimento , Escherichia coli O157/fisiologia , Manipulação de Alimentos , Carne/microbiologia , Animais , Bovinos , Contagem de Colônia Microbiana , Escherichia coli , Escherichia coli O157/crescimento & desenvolvimento , Polietileno , Aço Inoxidável , Temperatura , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA