Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ultrasound Int Open ; 7(2): E48-E54, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34804771

RESUMO

Purpose Continuous wave Doppler ultrasound is routinely used to detect cardiac valve stenoses. Vector flow imaging (VFI) is an angle-independent real-time ultrasound method that can quantify flow complexity. We aimed to evaluate if quantification of flow complexity could reliably assess valvular stenosis in pediatric patients. Materials and Methods Nine pediatric patients with echocardiographically confirmed valvular stenosis were included in the study. VFI and Doppler measurements were compared with transvalvular peak-to-peak pressure differences derived from invasive endovascular catheterization. Results Vector concentration correlated with the catheter measurements before intervention after exclusion of one outlier (r=-0.83, p=0.01), whereas the Doppler method did not (r=0.49, p=0.22). The change in vector concentration after intervention correlated strongly with the change in the measured catheter pressure difference (r=-0.86, p=0.003), while Doppler showed a tendency for a moderate correlation (r=0.63, p=0.07). Conclusion Transthoracic flow complexity quantification calculated from VFI data is feasible and may be useful for assessing valvular stenosis severity in pediatric patients.

3.
Diagnostics (Basel) ; 11(10)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34679630

RESUMO

The purpose of this study was to assess the image quality of the low dose 2D/3D slot scanner (LDSS) imaging system compared to conventional digital radiography (DR) imaging systems. Visual image quality was assessed using the visual grading analysis (VGA) method. This method is a subjective approach that uses a human observer to evaluate and optimise radiographic images for different imaging technologies. METHODS AND MATERIALS: ten posterior-anterior (PA) and ten lateral (LAT) images of a chest anthropomorphic phantoms and a knee phantom were acquired by an LDSS imaging system and two conventional DR imaging systems. The images were shown in random order to three (chest) radiologists and three experienced (knee) radiographers, who scored the images against a number of criteria. Inter- and intraobserver agreement was assessed using Fleiss' kappa and weighted kappa. RESULTS: the statistical comparison of the agreement between the observers showed good interobserver agreement, with Fleiss' kappa coefficients of 0.27-0.63 and 0.23-0.45 for the chest and knee protocols, respectively. Comparison of intraobserver agreement also showed good agreement with weighted kappa coefficients of 0.27-0.63 and 0.23-0.45 for the chest and knee protocols, respectively. The LDSS imaging system achieved significantly higher VGA image quality compared to the DR imaging systems in the AP and LAT chest protocols (p < 0.001). However, the LDSS imaging system achieved lower image quality than one DR system (p ≤ 0.016) and equivalent image quality to the other DR systems (p ≤ 0.27) in the knee protocol. The LDSS imaging system achieved effective dose savings of 33-52% for the chest protocol and 30-35% for the knee protocol compared with DR systems. CONCLUSIONS: this work has shown that the LDSS imaging system has the potential to acquire chest and knee images at diagnostic quality and at a lower effective dose than DR systems.

4.
BMJ Case Rep ; 14(5)2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34035019

RESUMO

A 21-year-old, otherwise healthy, female patient was admitted with haemoptysis. Chest X-ray and CT found a consolidated right middle pulmonary lobe. Catheter angiography of ascending aorta visualised two hypertrophic and tortuous branches of the right internal mammary artery with a fistula to the right superior pulmonary vein. The inflow was embolised with coils. Catheter angiography of descending aorta found hypertrophic right bronchial arteries and right phrenic artery supplying a web-like network of vessels, which drained to the right superior pulmonary vein with discrete filling of an accessory right middle pulmonary vein. CT angiography with a catheter for contrast administration in the ascending aorta was performed for characterisation. After two additional episodes of haemoptysis, right middle lobe lobectomy was performed. Perioperatively pulmonary artery blood supply to the right middle pulmonary lobe was absent and an atretic accessory middle pulmonary vein was seen. The patient was discharged 7 days afterwards without sequelae.


Assuntos
Fístula , Artéria Torácica Interna , Veias Pulmonares , Adulto , Anastomose Cirúrgica , Feminino , Hemoptise/etiologia , Hemoptise/terapia , Humanos , Artéria Torácica Interna/diagnóstico por imagem , Artéria Pulmonar , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Adulto Jovem
5.
Ultrasound Med Biol ; 46(9): 2493-2504, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32595057

RESUMO

Non-invasive assessment is preferred for monitoring arteriovenous dialysis fistulas (AVFs). Vector concentration assesses flow complexity, which may correlate with stenosis severity. We determined whether vector concentration could assess stenosis severity in dysfunctional AVFs. Vector concentration was estimated in four stenotic phantoms at different pulse repetition frequencies. Spectral Doppler peak velocity and vector concentration were measured in 12 patients with dysfunctional AVFs. Additionally, 5 patients underwent digital subtraction angiography (DSA). In phantoms, vector concentration exhibited an inverse relationship with stenosis severity and was less affected by aliasing in severe stenoses. In nine stenoses of 5 patients undergoing DSA, vector concentration correlated strongly with stenosis severity (first stenosis: r = -0.73, p = 0.04; other stenoses; r = -0.69, p = 0.02) and mid-stenotic diameter (first stenosis: r = 0.87, p = 0.006; other stenoses: r = 0.70, p = 0.02) as opposed to peak velocities (p > 0.05). Vector concentration is less affected by aliasing in severe stenoses and correlates with DSA in patients with dysfunctional AVF.


Assuntos
Derivação Arteriovenosa Cirúrgica , Constrição Patológica/diagnóstico por imagem , Diálise Renal , Humanos , Imagens de Fantasmas , Reologia , Índice de Gravidade de Doença , Ultrassonografia Doppler
6.
Ultrasound Int Open ; 4(3): E91-E98, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30276359

RESUMO

Purpose Spectral Doppler ultrasound (SDUS) is used for quantifying reflux in lower extremity varicose veins. The technique is angle-dependent opposed to the new angle-independent Vector Flow Imaging (VFI) method. The aim of this study was to compare peak reflux velocities obtained with VFI and SDUS in patients with chronic venous disease, i. e., pathological retrograde blood flow caused by incompetent venous valves. Materials and Methods 64 patients with chronic venous disease were scanned with VFI and SDUS in the great or the small saphenous vein, and reflux velocities were compared to three assessment tools for chronic venous disease. A flow rig was used to assess the accuracy and precision of the two methods. Results The mean peak reflux velocities differed significantly (VFI: 47.4 cm/s vs. SDUS: 62.0 cm/s, p<0.001). No difference in absolute precision (p=0.18) nor relative precision (p=0.79) was found. No correlation to disease severity, according to assessment tools, was found for peak reflux velocities obtained with either method. In vitro, VFI was more accurate but equally precise when compared to SDUS. Conclusion Both VFI and SDUS detected the pathologic retrograde flow in varicose veins but measured different reflux velocities with equal precision. VFI may play a role in evaluating venous disease in the future.

7.
Ultrasound Med Biol ; 44(9): 1941-1950, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29960752

RESUMO

Respiratory variability of peak velocities (RVPV) in the common femoral vein measured with ultrasound can reveal venous outflow obstruction. Pulse wave (PW) Doppler is the gold standard for venous velocity estimation of the lower extremities. PW Doppler measurements are angle dependent, whereas vector flow imaging (VFI) can yield angle-independent measures. The hypothesis of the present study was that VFI can provide RVPV estimations without the angle dependency of PW Doppler for an improved venous disease assessment. Sixty-seven patients with symptomatic chronic venous disease were included in the study. On average, VFI measured a lower RVPV than PW Doppler (VFI: 14.11 cm/s; PW: 17.32 cm/s, p = 0.002) with a non-significant improved precision compared with PW Doppler (VFI: 21.09%; PW: 26.49%, p = 0.08). In a flow phantom, VFI had improved accuracy (p < 0.01) and equal precision compared with PW Doppler. The study indicated that VFI can characterize the hemodynamic fluctuations in the common femoral vein.


Assuntos
Veia Femoral/diagnóstico por imagem , Veia Femoral/fisiopatologia , Respiração , Ultrassonografia Doppler/métodos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
8.
Diagnostics (Basel) ; 9(1)2018 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-30597993

RESUMO

Invasive catheterization is associated with a low risk of serious complications. However, although it is the gold standard for measuring pressure gradients, it induces changes to blood flow and requires significant resources. Therefore, non-invasive alternatives are urgently needed. Pressure gradients are routinely estimated non-invasively in clinical settings using ultrasound and calculated with the simplified Bernoulli equation, a method with several limitations. A PubMed literature search on validation of non-invasive techniques was conducted, and studies were included if non-invasively estimated pressure gradients were compared with invasively measured pressure gradients in vivo. Pressure gradients were mainly estimated from velocities obtained with Doppler ultrasound or magnetic resonance imaging. Most studies used the simplified Bernoulli equation, but more recent studies have employed the expanded Bernoulli and Navier⁻Stokes equations. Overall, the studies reported good correlation between non-invasive estimation of pressure gradients and catheterization. Despite having strong correlations, several studies reported the non-invasive techniques to either overestimate or underestimate the invasive measurements, thus questioning the accuracy of the non-invasive methods. In conclusion, more advanced imaging techniques may be needed to overcome the shortcomings of current methods.

9.
Ultrasound Med Biol ; 44(3): 593-601, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29223701

RESUMO

The study described here investigated whether angle-independent vector flow imaging (VFI) technique estimates peak velocities in the portal vein comparably to pulsed wave Doppler (PWD). Furthermore, intra- and inter-observer agreement was assessed in a substudy. VFI and PWD peak velocities were estimated with from intercostal and subcostal views for 32 healthy volunteers, and precision analyses were conducted. Blinded to estimates, three physicians rescanned 10 volunteers for intra- and inter-observer agreement analyses. The precision of VFI and PWD was 18% and 28% from an intercostal view and 23% and 77% from a subcostal view, respectively. Bias between VFI and PWD was 0.57 cm/s (p = 0.38) with an intercostal view and 9.89 cm/s (p <0.001) with a subcostal view. Intra- and inter-observer agreement was highest for VFI (inter-observer intra-class correlation coefficient: VFI 0.80, PWD 0.3; intra-observer intra-class correlation coefficient: VFI 0.90, PWD 0.69). Regardless of scan view, VFI was more precise than PWD.


Assuntos
Veia Porta/fisiologia , Ultrassonografia/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veia Porta/diagnóstico por imagem , Valores de Referência , Reprodutibilidade dos Testes , Ultrassonografia Doppler de Pulso/métodos
10.
Ultrasound Med Biol ; 43(10): 2477-2487, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28750944

RESUMO

Ultrasound is used for evaluating the veins of the lower extremities. Operator and angle dependency limit spectral Doppler ultrasound (SDUS). The aim of the study was to compare peak velocity measurements in a flow phantom and the femoropopliteal vein of 20 volunteers with the angle-independent vector velocity technique vector flow imaging (VFI) and SDUS. In the flow phantom, VFI underestimated velocity (p = 0.01), with a lower accuracy of 5.5% (p = 0.01) and with no difference in precision, that is, error factor, compared with SDUS (VFI: 1.02 vs. SDUS: 1.02, p = 0.58). In vivo, VFI estimated lower velocities (femoral: p = 0.001; popliteal: p = 0.001) with no difference in precision compared with SDUS (femoral: VFI 1.09 vs. SDUS 1.14, p = 0.37; popliteal: VFI 1.13 vs. SDUS 1.06, p = 0.09). In conclusion, the precise VFI technique can be used to characterize venous hemodynamics of the lower extremities despite its underestimation of velocities.


Assuntos
Veia Femoral/fisiologia , Imagens de Fantasmas , Veia Poplítea/fisiologia , Ultrassonografia/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Ultrassonografia Doppler/métodos , Adulto Jovem
11.
Ugeskr Laeger ; 178(44)2016 Oct 31.
Artigo em Dinamarquês | MEDLINE | ID: mdl-27808055

RESUMO

Chronic venous disease affects one quarter of the population and is routinely examined with Doppler ultrasound. The veins are evaluated in terms of diameter, compressibility and blood flow. The examination is performed with the patient in the standing position but can be complemented in the supine position, if disease of the deep veins is suspected. New angle-independent ultrasound techniques may contribute with more complex visualization of the blood flow and may in the future replace Doppler ultrasound in some areas of vein diagnostics.


Assuntos
Ultrassonografia/métodos , Insuficiência Venosa/diagnóstico por imagem , Doença Crônica , Humanos , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/irrigação sanguínea , Ultrassonografia Doppler/métodos , Varizes/terapia , Veias/anatomia & histologia , Insuficiência Venosa/patologia , Insuficiência Venosa/fisiopatologia , Insuficiência Venosa/terapia
12.
Acta Radiol Open ; 4(11): 2058460115603248, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26600943

RESUMO

Sarcomas are rare tumors originating from soft tissue or bone. Diagnosis and treatment of sarcomas should be performed at specialized sarcoma centers, where patients are evaluated at a multidisciplinary tumor conference. We present a case where sarcoma was suspected from magnetic resonance imaging (MRI), but histology revealed a metastasis from thyroid carcinoma, although the patient had no previous history of thyroid malignancy and resection of the thyroid gland was without malignancy. Ultrasound-guided biopsy was possible due to cortical destruction and the multidisciplinary approach with re-evaluation of previous pathology and a thorough patient history enabled a final diagnosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...