Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 8052, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-35577824

RESUMO

Ocean acidification is a threat to deep-sea corals and could lead to dramatic and rapid loss of the reef framework habitat they build. Weakening of structurally critical parts of the coral reef framework can lead to physical habitat collapse on an ecosystem scale, reducing the potential for biodiversity support. The mechanism underpinning crumbling and collapse of corals can be described via a combination of laboratory-scale experiments and mathematical and computational models. We synthesise data from electron back-scatter diffraction, micro-computed tomography, and micromechanical experiments, supplemented by molecular dynamics and continuum micromechanics simulations to predict failure of coral structures under increasing porosity and dissolution. Results reveal remarkable mechanical properties of the building material of cold-water coral skeletons of 462 MPa compressive strength and 45-67 GPa stiffness. This is 10 times stronger than concrete, twice as strong as ultrahigh performance fibre reinforced concrete, or nacre. Contrary to what would be expected, CWCs retain the strength of their skeletal building material despite a loss of its stiffness even when synthesised under future oceanic conditions. As this is on the material length-scale, it is independent of increasing porosity from exposure to corrosive water or bioerosion. Our models then illustrate how small increases in porosity lead to significantly increased risk of crumbling coral habitat. This new understanding, combined with projections of how seawater chemistry will change over the coming decades, will help support future conservation and management efforts of these vulnerable marine ecosystems by identifying which ecosystems are at risk and when they will be at risk, allowing assessment of the impact upon associated biodiversity.


Assuntos
Antozoários , Animais , Antozoários/química , Recifes de Corais , Ecossistema , Concentração de Íons de Hidrogênio , Oceanos e Mares , Água do Mar/química , Água , Microtomografia por Raio-X
2.
Micromachines (Basel) ; 11(2)2020 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-32053957

RESUMO

Optical biopsy describes a range of medical procedures in which light is used to investigate disease in the body, often in hard-to-reach regions via optical fibres. Optical biopsies can reveal a multitude of diagnostic information to aid therapeutic diagnosis and treatment with higher specificity and shorter delay than traditional surgical techniques. One specific type of optical biopsy relies on Raman spectroscopy to differentiate tissue types at the molecular level and has been used successfully to stage cancer. However, complex micro-optical systems are usually needed at the distal end to optimise the signal-to-noise properties of the Raman signal collected. Manufacturing these devices, particularly in a way suitable for large scale adoption, remains a critical challenge. In this paper, we describe a novel fibre-fed micro-optic system designed for efficient signal delivery and collection during a Raman spectroscopy-based optical biopsy. Crucially, we fabricate the device using a direct-laser-writing technique known as ultrafast laser-assisted etching which is scalable and allows components to be aligned passively. The Raman probe has a sub-millimetre diameter and offers confocal signal collection with 71.3% ± 1.5% collection efficiency over a 0.8 numerical aperture. Proof of concept spectral measurements were performed on mouse intestinal tissue and compared with results obtained using a commercial Raman microscope.

3.
J Biophotonics ; 12(11): e201900055, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31240824

RESUMO

Ultrashort pulse lasers offer great promise for tissue resection with exceptional precision and minimal thermal damage. Surgery in the bowel requires high precision and minimal necrotic tissue to avoid severe complications such as perforation. The deployment of ultrashort lasers in minimally invasive or endoscopic procedures has been hindered by the lack of suitable optical fibres for high peak powers. However, recent developments of hollow core microstructured fibres provide potential for delivery of such pulses throughout the body. In this study, analysis of laser ablation via a scanning galvanometer on a porcine colon tissue model is presented. A thermally damaged region (<85 µm) and fine depth control of ablation using the pulse energies 46 and 33 µJ are demonstrated. It is further demonstrated that such pulses suitable for precision porcine colon resection can be flexibly delivered via a hollow core negative curvature fibre (HC-NCF) and again ablation depth can be controlled with a thermally damaged region <85 µm. Ablation volumes are comparable to that of early stage lesions in the inner lining of the colon. This study concludes that the combination of ultrashort pulses and flexible fibre delivery via HC-NCF present a viable route to new minimally invasive surgical procedures.


Assuntos
Técnicas de Ablação/instrumentação , Colo/cirurgia , Lasers , Animais , Colo/citologia , Suínos
4.
Acta Biomater ; 89: 313-329, 2019 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-30858052

RESUMO

The increasing incidence of osteoporotic bone fractures makes fracture risk prediction an important clinical challenge. Computational models can be utilised to facilitate such analyses. However, they critically depend on bone's underlying hierarchical material description. To understand bone's irreversible behaviour at the micro- and nanoscale, we developed an in situ testing protocol that allows us to directly relate the experimental data to the mechanical behaviour of individual mineralised collagen fibres and its main constitutive phases, the mineralised collagen fibrils and the mineral nanocrystals, by combining micropillar compression of single fibres with small angle X-ray scattering (SAXS) and X-ray diffraction (XRD). Failure modes were assessed by SEM. Strain ratios in the elastic region at fibre, fibril and mineral levels were found to be approximately 22:5:2 with strain ratios at the point of compressive strength of 0.23 ±â€¯0.11 for fibril-to-fibre and 0.07 ±â€¯0.01 for mineral-to-fibre levels. Mineral-to-fibre levels showed highest strain ratios around the apparent yield point, fibril-to-fibre around apparent strength. The mineralised collagen fibrils showed a delayed mechanical response, contrary to the mineral phase, which points towards preceding deformations of mineral nanocrystals in the extrafibrillar matrix. No damage was measured at the level of the mineralised collagen fibre which indicates an incomplete separation of the mineral and collagen, and an extrafibrillar interface failure. The formation of kink bands and the gradual recruitment of fibrils upon compressive loading presumably led to localised strains. Our results from a well-controlled fibrillar architecture provide valuable input for micromechanical models and computational non-linear bone strength analyses that may provide further insights for personalised diagnosis and treatment as well as bio-inspired implants for patients with bone diseases. STATEMENT OF SIGNIFICANCE: Musculoskeletal diseases such as osteoporosis, osteoarthritis or bone cancer significantly challenge health care systems and make fracture risk prediction and treatment optimisation important clinical goals. Computational methods such as finite element models have the potential to optimise analyses but highly depend on underlying material descriptions. We developed an in situ testing set-up to directly relate experimental data to the mechanical behaviour of bone's fundamental building block, the individual mineralised collagen fibre and its main constituents. Low multilevel strain ratios suggest high deformations in the extrafibrillar matrix and energy dissipation at the interfaces, the absence of damage indicates both an incomplete separation between mineral and collagen and an extrafibrillar interface failure. The formation of kink bands in the fibril-reinforced composite presumably led to localised strains. The deformation behaviour of a well-controlled fibrillar architecture provides valuable input for non-linear bone strength analyses.


Assuntos
Colágeno/química , Força Compressiva , Matriz Extracelular/química , Estresse Mecânico , Espalhamento a Baixo Ângulo , Turquia , Difração de Raios X
5.
Appl Opt ; 50(18): 2899-905, 2011 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-21691353

RESUMO

We demonstrate the adverse influence of temporal fluctuations of the phase modulation of a spatial light modulator (SLM) display device on nanosecond laser micromachining. We show that active cooling of the display reduces the amplitude of these fluctuations, and we demonstrate a process synchronization technique developed to compensate for these fluctuations when applying the SLM to laser materials processing. For alternative SLM devices developed specifically for laser wavefront control (which do not exhibit such flickering problems), we show that our process synchronization approach is also beneficial to avoid machining glitches when switching quickly between different phase profiles (and hence beam patterns).

6.
Appl Opt ; 50(12): 1779-85, 2011 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-21509071

RESUMO

Laser marking is demonstrated using a nanosecond (ns) pulse duration laser in combination with a liquid crystal spatial light modulator to generate two-dimensional patterns directly onto thin films and bulk metal surfaces. Previous demonstrations of laser marking with such devices have been limited to low average power lasers. Application in the ns regime enables more complex, larger scale marks to be generated with more widely available and industrially proven laser systems. The dynamic nature of the device is utilized to improve mark quality by reducing the impact of the inherently speckled intensity distribution across the generated image and reduce thermal effects in the marked surface.

7.
Opt Express ; 18(16): 17059-65, 2010 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-20721094

RESUMO

The application of a commercially available spatial light modulator (SLM) to control the spatial intensity distribution of a nanosecond pulsed laser for micromachining is described for the first time. Heat sinking is introduced to increase the average power handling capabilities of the SLM beyond recommended limits by the manufacturer. Complex intensity patterns are generated, using the Inverse Fourier Transform Algorithm, and example laser machining is demonstrated. The SLM enables both complex beam shaping and also beam steering.


Assuntos
Algoritmos , Análise de Fourier , Lasers , Luz , Microtecnologia/instrumentação , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA