Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
AJR Am J Roentgenol ; 200(6): W628-34, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701094

RESUMO

OBJECTIVE: The purpose of this study was to determine the effectiveness of a radiation dose reduction strategy for CT angiography by the combination of higher iodine delivery rate and automated tube potential selection with adjusted reference values for tube current-exposure time product, as well as to measure the impact of this approach on image quality. SUBJECTS AND METHODS: One hundred consecutive patients underwent high-pitch CT angiography of the thorax and abdomen using either 90 mL of iomeprol 300 (n = 44, protocol A) or 90 mL of iomeprol 400 (n = 56, protocol B) at the same flow rate. Automated tube potential selection was used with reference tube current-time products of 330 mAs and 250 mAs for protocols A and B, respectively. Twenty vascular segments were analyzed for attenuation and image noise by two readers. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all segments. The dose-length product (DLP) was documented to calculate effective dose and was compared between protocols both globally and for body mass index (BMI) subgroups. RESULTS: There were no differences in sex, height, weight, or BMI between both groups. Images from patients scanned with protocol B showed higher levels of image noise but also higher signal in all vascular segments. As a result, there were no differences in SNR between both groups. Conversely, CNR was significantly higher for almost all vascular segments in the group scanned using protocol B. Furthermore, DLP was significantly lower when protocol B was used, particularly in patients with a BMI of less than 30. CONCLUSION: In CT angiography, a combination of higher iodine delivery rate and automated tube potential selection with adjusted reference values for the tube current-time product allows reductions in radiation dose by approximately 30% without compromising image quality.


Assuntos
Angiografia/métodos , Aortografia/métodos , Meios de Contraste/administração & dosagem , Artéria Ilíaca/diagnóstico por imagem , Iopamidol/análogos & derivados , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Estudos Prospectivos , Razão Sinal-Ruído
2.
World J Radiol ; 4(7): 328-34, 2012 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-22900135

RESUMO

AIM: To assess the feasibility/accuracy of a commercial handheld device in the context of increased demand for point-of-care serum creatinine (SCr) determination. METHODS: In this institutional review board-approved, prospective study, 401 patients referred for contrast-enhanced computed tomography were included at two centres. Capillary (c)SCr was determined using two devices A+B and venous (v)SCr was determined in the centre's laboratory. Method comparison statistics for both centres and for vSCr<>1.2 mg/dL, receiver operating characteristic analysis, negative predictive values (NPV), sensitivity and specificity were calculated pre-/post-curve offset correction with vSCr. RESULTS: Pearson's coefficients for cSCr vs vSCr were: centre 1-A:0.93/B:0.92; centre 2-A:0.85/B:0.82 (all P < 0.0001). Overall correlation was better for vSCr > 1.2 mg/dL. The area under the receiver operating characteristic curves showed a high accuracy for cSCr, but the device underestimated SCr, which was confirmed by Bland-Altman plot. Addition of the offset correction factor to the original data from centre 1 resulted in an improvement in sensitivity for detecting patients at risk (> 1.2 mg/dL), whilst maintaining acceptable specificity and improving NPV. CONCLUSION: This study showed the feasibility of SCr determination using the evaluated handheld device in a routine clinical setting. The device showed high sensitivity and high NPV, but may significantly underestimate SCr without offset correction to local laboratories.

3.
Radiology ; 263(3): 917-26, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22623699

RESUMO

PURPOSE: To assess the feasibility and diagnostic performance of time-resolved computed tomographic (CT) angiography in the detection and classification of endoleaks after endovascular aortic aneurysm repair (EVAR) in high-risk patients. MATERIALS AND METHODS: The study was approved by our ethics committee. Written informed consent was obtained from all participating patients. Fifty-four patients (42 male and 12 female patients; mean age, 70.9 years ± 9.3 [standard deviation]) with either thoracic (n = 8) or abdominal (n = 46) aortic aneurysms treated with a stent-graft were prospectively included. The patients were examined with a time-resolved CT angiographic protocol consisting of 12 low-dose phases (80 kVp; 120 mAs [effective]; scan range, 27 cm), with 60 mL of iomeprol. Patients with abdominal aneurysm repair also underwent contrast material-enhanced (CE) ultrasonography (US). The time delay between contrast enhancement within the stent lumen and the endoleak was measured. Effective radiation dose was calculated from the scanner protocols. Measures of diagnostic performance for the detection of endoleaks were calculated for time-resolved CT angiography, with CE US serving as the reference standard. RESULTS: All time-resolved CT angiographic data sets were diagnostic. Mean effective radiation dose was 14.6 mSv. Four thoracic and 19 abdominal endoleaks were identified by using time-resolved CT angiography. Seventeen of 19 abdominal endoleaks were confirmed with CE US. This rate resulted in a sensitivity of 94%, a specificity of 93%, a positive predictive value of 89%, and a negative predictive value of 96% for time-resolved CT angiography after abdominal EVAR. Type I endoleaks showed significantly earlier mean peak contrast enhancement (0.28 second ± 0.83) compared with that for type II endoleaks (9.17 seconds ± 3.59, P < .0001). CONCLUSION: Time-resolved CT angiography with 12 low-dose phases is feasible for patients after thoracic and abdominal EVAR. The protocol approximates the radiation dose of standard triphasic protocols. Its dynamic information differentiates types of endoleaks and shows high diagnostic performance.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/terapia , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Endoleak/classificação , Estudos de Viabilidade , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Fosfolipídeos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Hexafluoreto de Enxofre , Fatores de Tempo
4.
Eur J Radiol ; 81(12): 3697-702, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21196093

RESUMO

OBJECTIVE: To evaluate diagnostic image quality of high-pitch dual source comprehensive cardiothoracic CT protocol in patients presenting with acute undifferentiated chest pain. MATERIALS AND METHODS: Consecutive symptomatic subjects (n=51) with undifferentiated acute chest pain underwent ECG-synchronized high-pitch dual-spiral chest CT angiography (Definition Flash, Siemens Medical Solutions, 2 × 100 kVp or 2 × 120 kV if BMI>30, collimation: 128 × 0.6mm, pitch: 3.2). Independent investigators determined the image quality of each cardiac and pulmonary vessel segment, measured contrast-to-noise-ratio (CNR), and determined radiation exposure. In addition, the prevalence of CT findings (pulmonary embolism (PE), aortic dissection (AD) and significant coronary stenosis (≥ 50%)) was determined. Univariate and multivariate analysis were performed to determine the subpopulation with highest diagnostic quality. RESULTS: Among 51 subjects (66% male, average age: 63 ± 15.8), the prevalence of positive CT findings was moderate (overall: 11.7%). Overall, image quality of the pulmonary, aortic and coronary vasculature was good (1.26 ± 0.43 and CNR: 2.52) with an average radiation dose of 3.82 mSv and 3.2% of segments rated non-evaluable. The image quality was lowest in the coronary arteries (p=0.02), depending on the heart rate (r=0.52, p<0.001). In subjects with a heart rate of ≤ 65 bpm (n=30) subjective image quality and CNR of the coronary arteries were higher (1.6 ± 0.5 vs. 2.1 ± 0.5, p=0.03 and 1.21 ± 0.3 vs. 1.02 ± 0.3, p=0.05) with only 1.5% segments classified as non-evaluable. CONCLUSION: High-pitch dual-spiral comprehensive cardiothoracic CT provides low radiation exposure with excellent image quality at heart rates ≤ 65 bpm. In subjects with higher heart rates, image quality of the aortic and pulmonary vasculature remains excellent, while the assessment of the coronary arteries degrades substantially.


Assuntos
Algoritmos , Angiografia/métodos , Dor no Peito/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada Espiral/métodos , Doença Aguda , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Heart ; 98(6): 460-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21846767

RESUMO

AIMS: The study aims to determine the direct costs and comparative cost-effectiveness of latest-generation dual-source computed tomography (DSCT) and invasive coronary angiography for diagnosing coronary artery disease (CAD) in patients suspected of having this disease. METHODS: The study was based on a previously elaborated cohort with an intermediate pretest likelihood for CAD and on complementary clinical data. Cost calculations were based on a detailed analysis of direct costs, and generally accepted accounting principles were applied. Based on Bayes' theorem, a mathematical model was used to compare the cost-effectiveness of both diagnostic approaches. Total costs included direct costs, induced costs and costs of complications. Effectiveness was defined as the ability of a diagnostic test to accurately identify a patient with CAD. RESULTS: Direct costs amounted to €98.60 for DSCT and to €317.75 for invasive coronary angiography. Analysis of model calculations indicated that cost-effectiveness grew hyperbolically with increasing prevalence of CAD. Given the prevalence of CAD in the study cohort (24%), DSCT was found to be more cost-effective than invasive coronary angiography (€970 vs €1354 for one patient correctly diagnosed as having CAD). At a disease prevalence of 49%, DSCT and invasive angiography were equally effective with costs of €633. Above a threshold value of disease prevalence of 55%, proceeding directly to invasive coronary angiography was more cost-effective than DSCT. CONCLUSIONS: With proper patient selection and consideration of disease prevalence, DSCT coronary angiography is cost-effective for diagnosing CAD in patients with an intermediate pretest likelihood for it. However, the range of eligible patients may be smaller than previously reported.


Assuntos
Angiografia Coronária/economia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/economia , Tomografia Computadorizada por Raios X/economia , Tomografia Computadorizada por Raios X/métodos , Análise Custo-Benefício , Árvores de Decisões , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
6.
J Am Coll Cardiol ; 57(24): 2426-36, 2011 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-21658564

RESUMO

OBJECTIVES: We conducted a systematic review and meta-analysis to determine the predictive value of findings of coronary computed tomography angiography for incident cardiovascular events. BACKGROUND: Initial studies indicate a prognostic value of the technique; however, the level of evidence as well as exact independent risk estimates remain unclear. METHODS: We searched PubMed, EMBASE, and the Cochrane Library through January 2010 for studies that followed up ≥ 100 subjects for ≥ 1 year and reported at ≥ 1 hazard ratio (HR) of interest. Risk estimates for the presence of significant coronary stenosis (primary endpoint; ≥ 50% diameter stenosis), left main coronary artery stenosis, each coronary stenosis, 3-vessel disease, any plaque, per coronary segment containing plaque, and noncalcified plaque were derived in random effect regression analysis, and causes of heterogeneity were determined in meta-regression analysis. RESULTS: We identified 11 eligible articles including 7,335 participants (age 59.1 ± 2.6 years, 62.8% male) with suspected coronary artery disease. The presence of ≥ 1 significant coronary stenosis (9 studies, 3,670 participants, and 252 outcome events [6.8%] with 62% revascularizations) was associated with an annualized event rate of 11.9% (6.4% in studies excluding revascularization). The corresponding HR was 10.74 (98% confidence interval [CI]: 6.37 to 18.11) and 6.15 (95% CI: 3.22 to 11.74) in studies excluding revascularization. Adjustment for coronary calcification did not attenuate the prognostic significance (p = 0.79). The estimated HRs for left main stenosis, presence of plaque, and each coronary segment containing plaque were 6.64 (95% CI: 2.6 to 17.3), 4.51 (95% CI: 2.2 to 9.3), and 1.23 (95% CI: 1.17 to 1.29), respectively. CONCLUSIONS: Presence and extent of coronary artery disease on coronary computed tomography angiography are strong, independent predictors of cardiovascular events despite heterogeneity in endpoints, categorization of computed tomography findings, and study population.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida
7.
Eur Radiol ; 21(7): 1424-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21249370

RESUMO

OBJECTIVE: The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS: 31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, tube current relation: 3:1). Specific post-processing was applied to generate energies of standard 120 and 140 kVp spectra as well as a filtered 140 kVp spectrum with mean photon energies of 64, 69 and 88 keV, respectively, and an optimized hard spectrum of 95-150 keV. Image quality and diagnostic value were subjectively and objectively determined. RESULTS: Image quality was rated superior to the standard image in 29/31 high energy reconstructions; the diagnostic value was rated superior in 27 patients. Image quality and diagnostic value scores improved significantly from 3.5 to 2.1 and from 3.6 to 1.9, respectively. In several exams decisive diagnostic features were only discernible in the high energy reconstructions. The density of the artefacts decreased from -882 to -341 HU. CONCLUSIONS: Dual Energy CT with specific postprocessing can reduce metal artefacts and may significantly enhance diagnostic value in the evaluation of metallic implants.


Assuntos
Artefatos , Metais , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
8.
Eur J Radiol ; 77(2): 312-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19720488

RESUMO

RATIONALE AND OBJECTIVE: The aim of this pilot study was the evaluation of CT perfusion patterns in metastatic GIST lesions under specific molecular therapy with sunitinib or imatinib both in responders and non-responders. PATIENTS AND METHODS: 24 patients with metastatic GIST under tyrosine kinase inhibition were retrospectively evaluated. A total of 46 perfusion and venous phase CT scans were acquired. Volume of distribution, blood flow, blood volume, permeability and hepatic perfusion index measurements of metastatic lesions were carried out. Lesions were classified as "good response" or "poor response" to therapy, and perfusion parameters were compared for these two types of lesions. RESULTS: 24 patients were evaluated. In the extrahepatic abdominal lesions (N = 15), good responders showed significant lower perfusion values than poor responders (volume of distribution: 3.3 ± 2.0 vs. 13.0 ± 1.8 ml/100ml, p = 0.001). The same tendency was observed in intrahepatic lesions (N = 31) (liver volume of distribution: 2.1 ± 0.3 vs. 7.1 ± 1.3 ml/100ml, p = 0.003); (hepatic perfusion index: 24.3 ± 7.9 vs. 76.1 ± 1.5%, p = 0.0001). CONCLUSION: Our data indicate that there are characteristic perfusion patterns of metastatic GIST lesions showing a good or poor response to molecular pharmacotherapy. Perfusion should be further evaluated in cross-sectional imaging studies as a possible biomarker for treatment response in targeted therapies of GIST.


Assuntos
Angiografia/métodos , Tumores do Estroma Gastrointestinal , Indóis/uso terapêutico , Imagem de Perfusão/métodos , Piperazinas/uso terapêutico , Pirimidinas/uso terapêutico , Pirróis/uso terapêutico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Benzamidas , Feminino , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/secundário , Humanos , Mesilato de Imatinib , Masculino , Pessoa de Meia-Idade , Terapia de Alvo Molecular/métodos , Projetos Piloto , Proteínas Tirosina Quinases/antagonistas & inibidores , Sunitinibe , Resultado do Tratamento
9.
Eur Radiol ; 20(12): 2876-81, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20589380

RESUMO

OBJECTIVE: The aim of this study was to test the feasibility of time-resolved computed tomography angiography (TR-CTA) for use in the lower leg. METHODS: Fifty-nine patients with suspected peripheral arterial occlusive disease were examined with a standard CTA (S-CTA) of the lower run-off and with an additional TR-CTA of the calves (12 phases; 2.5 s/phase, 80 kV, 120 mAs, volume of contrast medium 50 mL, flow rate 5.0 mL/s). For seven lower-leg artery segments, arterial contrast and the presence of venous overlay were tested for S-CTA and TR-CTA. Stenoses were classified on a three-point scale separately for S-CTA and TR-CTA, and diagnostic confidence for stenosis assessment was evaluated for both datasets. Contrast arrival times and HU values were evaluated in patients with asymmetric proximal stenoses. RESULTS: TR-CTA resulted in significantly higher contrast enhancement (P < 0.0001) and less venous overlay as compared to S-CTA (P < 0.05). Diagnostic confidence for stenosis rating was significantly higher in TR-CTA (P < 0.0001). Asymmetric proximal stenoses lead to significantly delayed and diminished contrast enhancement on the stenotic side. CONCLUSION: TR-CTA of the calves is feasible and provides higher enhancement and higher diagnostic confidence as compared to monophasic CTA of the lower legs.


Assuntos
Angiografia/métodos , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Clin Hemorheol Microcirc ; 45(1): 19-25, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20571226

RESUMO

We report discordant imaging findings of a small persistent type II endoleak in a 72-year-old man who had undergone endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm. Although the aneurysm was growing in size digital subtraction angiography could not detect an endoleak, but time-resolved CT-angiography and contrast enhanced ultrasound did detect a small type II endoleak.


Assuntos
Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Angiografia Digital , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Ultrassonografia
11.
Eur Radiol ; 20(12): 2882-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20571800

RESUMO

OBJECTIVE: To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. METHODS: Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. RESULTS: In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. CONCLUSION: With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation.


Assuntos
Pulmão/diagnóstico por imagem , Imagem de Perfusão/métodos , Ventilação Pulmonar , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Xenônio , Adulto , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Invest Radiol ; 45(7): 363-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20458248

RESUMO

OBJECTIVE: Recent technical developments have led to an extension of perfusion computed tomography (PCT) scan range to cover nearly the entire brain and to reconstruct time resolved (4d) CT-angiography (CTA) datasets from the PCT data. The purpose of this study was to compare the results of simulated standard PCT and extended PCT with 4d-CTA. MATERIALS AND METHODS: Extended multimodal stroke CT (unenhanced cranial CT, CTA, and PCT) was acquired in 72 patients. PCT images with a scan coverage of 9.6 cm in the z-axis, simulated 2 cm PCT images at the level of the basal ganglia comparable to standard PCT, standard supra-aortic CTA, and 4d-CTA images were reconstructed. Two readers assessed the PCT image quality as well as pathologic findings in extended and simulated PCT, CTA, and 4d-CTA. The brain was divided into 4 axial segments. The independent samples t test was applied to test differences between data for significance. RESULTS: In 75.0% of all patient exams, pathologic findings were observed in the PCT; these were located in 138 brain segments. In 24.1% of all 54 exams with pathologic PCT findings, the pathology would have been missed on standard PCT. The longer scan coverage resulted in a different final diagnosis in 34.7% of all exams. Quality of the PCT parameter maps was on average very good both for the supratentoric and the infratentoric brain areas (4.28 and 4.18, respectively, on a 5-point scale). In 90% of all exams with pathologic changes in the CTA, these abnormalities were also noted on 4d-CTA. In only 2.8% of all cases, the additional time resolution of the 4d-CTA provided additional information. CONCLUSION: Extending the scan coverage of PCT from 2 cm to 9.6 cm led to an augmentation of clinically important information in the imaging of acute stroke.


Assuntos
Angiografia Cerebral/métodos , Imagem de Perfusão/métodos , Intensificação de Imagem Radiográfica/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Thorac Imaging ; 25(2): 161-7, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20463535

RESUMO

PURPOSE: The aim of this study was to test the feasibility and the additional value of time-resolved computed tomography angiography (CTA) of the aorta, using multiple low-dose phases. MATERIALS AND METHODS: Twenty-two consecutive patients underwent a time-resolved CTA protocol (TR-CTA) of the aorta, either for follow-up of endovascular aneurysm repair (EVAR) or aortic dissection, using a CT scanner with the possibility of bidirectional table movements for dynamic CT imaging (Siemens Definition AS+; 12 phases, temporal resolution 2.5 s/scan, 80 kVp, 120 mAs/rot, scan range 27 cm, 60 mL; Imeron 400, flow 5.0 mL/s). The patients had previously undergone standard CTA (120 kVp, 100 mL contrast agent). Standard CTA after EVAR and aortic dissection were triphasic and biphasic protocols, respectively. Effective radiation dose and maximum Hounsfield unit values were compared between the TR-CTA and standard CTA. Image quality was rated for TR-CTA. RESULTS: Fifteen patients underwent TR-CTA for follow-up after EVAR; 4 were examined for follow-up after dissection and 3 for both, that is, aortic dissection treated with an endovascular stent. Mean effective dose of TR-CTA for the scan range of 27 cm (15.3+/-1.1 mSv) was comparable with the biphasic standard CTA protocols (16.2+/-2.4 mSv; P=0.29). Triphasic protocols resulted in 23.7+/-4.9 mSv (P<0.0001). Hounsfield unit values were not significantly different. Most of the examinations (91%) were fully evaluable, whereas 9% were of limited evaluability because of high image noise. None of the examinations was nondiagnostic. DISCUSSION: TR-CTA consisting of multiple low-dose phases leads to a clear depiction of the angiographic information and is feasible for follow-up after EVAR and aortic dissection. Considering the limited scan range, radiation dose is comparable with the standard biphasic CTA protocol, but dynamic information may provide additional information.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/cirurgia , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estatísticas não Paramétricas , Fatores de Tempo
14.
Invest Radiol ; 45(7): 399-405, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20498609

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of dual-energy CT (DECT) in renal mass characterization using a single-phase acquisition. MATERIALS AND METHODS: A total of 202 patients (148 males, 54 females; 63 +/- 13 years) with ultrasound-based suspicion of a renal mass underwent unenhanced single energy and nephrographic phase DECT on a dual source scanner (Siemens Somatom Definition Dual Source, n = 174; Somatom Definition Flash, n = 28). Scan parameters for DECT were: tube potential, 80/100 and 100/Sn140 kVp; exposure, 404/300 and 96/232 effective mAs; collimation, 14 x 1.2/32 x 0.6 mm. Two abdominal radiologists assessed DECT and SECT image quality and noise on a 5-point visual analogue scale. Using solely the DE acquisition including virtual nonenhanced (VNE) and color coded iodine images that enable direct visualization of iodine, masses were characterized as benign or malignant. In a second reading session after 34 to 72 (average: 55) days, the same assessment was again performed using both the true nonenhanced (TNE) and nephrographic phase scans thereby simulating conventional single-energy CT. Sensitivities, specificities, diagnostic accuracies, and interpretation times and were recorded for both reading paradigms. Dose reduction of a single-phase over a dual-phase protocol was calculated. Results were tested for statistical significance using the paired Wilcoxon signed rank test and student t test. Differences in sensitivities were tested for significance using the McNemar test. RESULTS: Of the 202 patients, 115 (56.9%) underwent surgical resection of renal masses. Histopathology showed malignancy in 99 and benign tumors in 18 patients, in 48 patients (23.7%), follow-up imaging showed size stability of lesions diagnosed as benign, and 37 patients (18.3%) had no mass. Based on DECT only, 95/99 (96.0%) patients with malignancy and 96/103 (93.2%) patients without malignancy were correctly identified, for an overall accuracy of 94.6%. The dual-phase approach identified 96/99 (97.0%) and 98/103 (95.1%), accuracy 96.0%, P > 0.05 for both. Mean interpretation time was 2.2 +/- 0.8 minutes for DECT, and 3.5 +/- 1.0 minutes for the dual-phase protocol, P < 0.001. Mean VNE/TNE image quality was 1.68 +/- 0.65/1.30 +/- 0.59, noise was 2.03 +/- 0.57/1.18 +/- 0.29, P < 0.001 for both. Omission of the true unenhanced phase lead to a 48.9 +/- 7.0% dose reduction. CONCLUSION: DECT allows for fast and accurate characterization of renal masses in a single-phase acquisition. Interpretation of color coded images significantly reduces interpretation time. Omission of a nonenhanced acquisition can reduce radiation exposure by almost 50%.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Renais/classificação , Masculino , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Invest Radiol ; 45(6): 347-53, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20404737

RESUMO

OBJECTIVE: New generation Dual Source computed tomography (CT) scanners offer different x-ray spectra for Dual Energy imaging. Yet, an objective, manufacturer independent verification of the dose required for the different spectral combinations is lacking. The aim of this study was to assess dose and image noise of 2 different Dual Energy CT settings with reference to a standard chest scan and to compare image noise and contrast to noise ratios (CNR). Also, exact effective dose length products (E/DLP) conversion factors were to be established based on the objectively measured dose. MATERIALS AND METHODS: An anthropomorphic Alderson phantom was assembled with thermoluminescent detectors (TLD) and its chest was scanned on a Dual Source CT (Siemens Somatom Definition) in dual energy mode at 140 and 80 kVp with 14 x 1.2 mm collimation. The same was performed on another Dual Source CT (Siemens Somatom Definition Flash) at 140 kVp with 0.8 mm tin filter (Sn) and 100 kVp at 128 x 0.6 mm collimation. Reference scans were obtained at 120 kVp with 64 x 0.6 mm collimation at equivalent CT dose index of 5.4 mGy*cm. Syringes filled with water and 17.5 mg iodine/mL were scanned with the same settings. Dose was calculated from the TLD measurements and the dose length products of the scanner. Image noise was measured in the phantom scans and CNR and spectral contrast were determined in the iodine and water samples. E/DLP conversion factors were calculated as ratio between the measured dose form the TLDs and the dose length product given in the patient protocol. RESULTS: The effective dose measured with TLDs was 2.61, 2.69, and 2.70 mSv, respectively, for the 140/80 kVp, the 140 Sn/100 kVp, and the standard 120 kVp scans. Image noise measured in the average images of the phantom scans was 11.0, 10.7, and 9.9 HU (P > 0.05). The CNR of iodine with optimized image blending was 33.4 at 140/80 kVp, 30.7 at 140Sn/100 kVp and 14.6 at 120 kVp. E/DLP conversion factors were 0.0161 mSv/mGy*cm for the 140/80 kVp protocol, 0.0181 mSv/mGy*cm for the Sn140/100 kVp mode and 0.0180 mSv/mGy*cm for the 120 kVp examination. CONCLUSION: Dual Energy CT is feasible without additional dose. There is no significant difference in image noise, while CNR can be doubled with optimized dual energy CT reconstructions. A restriction in collimation is required for dose-neutrality at 140/80 kVp, whereas this is not necessary at 140 Sn/100 kVp. Thus, CT can be performed routinely in Dual Energy mode without additional dose or compromises in image quality.


Assuntos
Carga Corporal (Radioterapia) , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiografia Torácica , Tomografia Computadorizada por Raios X , Humanos , Dosimetria Termoluminescente
16.
Eur Radiol ; 20(5): 1168-73, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20333388

RESUMO

OBJECTIVE: To detail the principles of using model-based determination of regional myocardial blood flow (MBF) by computed tomography (CT) and demonstrate its in vivo applicability. METHODS: Dual-source CT was performed with a dynamic protocol comprising acquisition with alternating table positions in ECG-triggered end-systolic timing every second for 30 s. The results of two reconstructions were merged into one final image stack (coverage 73 mm), with low spatial frequency components from a 360 degrees reconstruction and high spatial frequency components from a dual-source cardiac partial image reconstruction. A parametric deconvolution technique was used to fit the time-attenuation curves (TAC), the maximum slope of which was used to derive MBF. RESULTS: One study participant underwent dynamic myocardial stress perfusion imaging (9.6 mSv) followed by invasive coronary angiography and measurement of fractional flow reserve as the gold standard. MBF was 159 ml/100 ml/min in the non-ischaemic anterolateral and 86 ml/100 ml/min in the inferoseptal ischaemic wall. CONCLUSION: This first evaluation indicates that mathematical modelling of voxel TACs can potentially be used to quantify differences in MBF in a clinical setting. If confirmed in feasibility studies, cardiac CT may allow for parallel assessment of morphology and haemodynamic relevance of coronary artery disease.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Doença da Artéria Coronariana/terapia , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Doses de Radiação , Stents , Sístole
17.
J Vasc Interv Radiol ; 21(3): 315-21, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20097097

RESUMO

PURPOSE: To compare true and "virtual" noncontrast images derived from dual-energy CT examinations in patients after endovascular repair of aortic aneurysms. MATERIALS AND METHODS: Seventy dual-energy CT examinations were performed on a dual-source CT scanner with a single-energy noncontrast scan and a dual-energy acquisition in venous phase. True and virtual noncontrast images were compared regarding image quality, calcifications in true noncontrast images, subtraction of calcification in virtual noncontrast images, and acceptance levels by two radiologists. Presence of endoleaks was assessed on venous-phase images and on virtual or true noncontrast images. In addition, the acceptance of color-coded images, in which iodine information is colored, was assessed. Possible dose reduction of a single-phase dual-energy examination protocol was compared with a standard biphasic examination protocol. RESULTS: Twenty-four endoleaks were detected and correctly classified with both approaches. Mean image quality was rated good for virtual noncontrast images (1.97 +/- 0.99) and excellent for true noncontrast images (1.16 +/- 0.37; P< .0001). Ninety-four percent of virtual noncontrast images were rated as diagnostic, and 80% of all true noncontrast images showed calcifications within the aneurysm. Subtraction of calcification in virtual noncontrast images was classified as none (30%), minimal (40%), moderate (24%), or severe (6%). Eighty-three percent of color-coded images were rated as fully diagnostic, 11% were accepted with restrictions, and 6% were nondiagnostic. Possible dose reduction of a single-phase dual-energy protocol, compared with a standard biphasic protocol, was 44%. CONCLUSIONS: Dual-energy CT makes a reliable detection of endoleaks feasible in a single acquisition. This provides a potential dose reduction for patients who have to undergo lifelong follow-up examinations after endovascular aneurysm repair.


Assuntos
Angiografia/métodos , Angioplastia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
18.
Invest Radiol ; 45(2): 64-71, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20027121

RESUMO

OBJECTIVE: High radiation doses remain a drawback of current triple-rule-out computed tomography (CT) protocols. With dual source CT, a new high-pitch dual spiral technique offers the possibility to acquire an Electrocardiography (ECG)-gated-synchronized dataset of the whole chest in less than 1 second. The aim of this study was to compare the dose of such a protocol to a standard, nongated chest scan and to a conventional, retrospectively ECG-gated triple-rule-out protocol. Also, the efficacy and dose of this dual spiral protocol was to be compared in patients examined with this high-pitch technique and matched controls scanned with the conventional technique. MATERIALS AND METHODS: An anthropomorphic Alderson Rando phantom was equipped with thermoluminescent detectors and scanned with the high-pitch protocol (Siemens Somatom Definition Flash; 2 x 120 kVp, 426 mAseff, 128 x 0.6 mm collimation, pitch 3.2), the nongated chest scan (same scanner; 120 kVp, 160 mAseff, 128 x 0.6 mm, pitch 1.2; equivalent Computed Tomography Dose Index (CTDI) of 7.12 mGy), and the conventional gating technique (Siemens Somatom Definition; 120 kVp, 560 mAseff with ECG pulsing interval at 30%-70% of the R-R cycle, 64 x 0.6 mm, pitch 0.3). Noise was measured in air, central and peripheral soft tissue of the phantom. Conversion factors were determined based on the measured dose and the dose-length products of the scanner. The protocol was then applied with ethics committee approval in 31 patients suffering from acute chest pain. The 120 mL of contrast material (Ultravist 370, Bayer Schering Pharma) was applied at 5 mL/s. Dose was calculated based on the dose-length products and the conversion factor. Image quality was assessed by 2 readers for aorta, pulmonary arteries, and coronary arteries. The results were compared with matched controls scanned with the conventional ECG gating technique and non-ECG gated thorax scans. RESULTS: The dose determined with thermoluminescent dosimeters measurements amounted to 2.65, 2.68, and 19.27 mSv, respectively, for the dual spiral technique, the standard chest scan, and the conventional retrospective technique. There was no significant difference in image noise. Respective conversion factors were 0.0186, 0.0188, and 0.0180 mSv/mGy x cm. In the patient examinations, dose was 4.08 +/- 0.81 mSv with the high-pitch protocol compared with 20.4 +/- 5.3 mSv in the matched controls with the conventional technique, and 4.40 +/- 0.83 mSv for the non-ECG gated thorax scan. Scan times were 0.7 +/- 0.1 seconds for the high-pitch scan and 15 +/- 3 seconds for the conventional chest pain scan. Aorta and pulmonary arteries were depicted in diagnostic quality in both groups. About 84.7% of coronary artery segments were rated as diagnostic in the high-pitch exams (95.4% below 65 bpm and only 72.8% in higher heart rates), whereas 92.9% were diagnostic with the conventional approach. CONCLUSION: The high-pitch dual spiral technique requires only about one-fifth of the dose of conventional ECG gated triple-rule-out protocols, thus matching that of a standard nongated chest scan. With less than 1 second, the scan time is very short. This protocol can be recommended for patients with unclear chest pain with rhythmic heart rates below 65 bpm.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Feminino , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral/instrumentação
19.
Eur Radiol ; 20(3): 572-83, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19789884

RESUMO

PURPOSE: The purpose of this study was to assess the influence of iodine concentration on diagnostic efficacy in multi-detector-row computed tomography (MDCT) angiography of the abdominal aorta and abdominal arteries. METHODS: IRB approval and informed consent were obtained. In this double-blind trial, patients were randomised to undergo MDCT angiography of the abdominal arteries during administration of iobitridol (350 mgI/ml) or iomeprol (400 mgI/ml). Each centre applied its own technique for delivery of contrast medium, regardless of iodine concentration. Diagnostic efficacy, image quality, visualisation of the arterial wall and arterial enhancement were evaluated. A total of 153 patients received iobitridol and 154 received iomeprol. RESULTS: The ability to reach a diagnosis was "satisfactory" to "totally satisfactory" in 152 (99.3%) and 153 (99.4%) patients respectively. Image quality was rated as being "good" to "excellent" in 94.7 and 94.8% segments respectively. Similar results were observed for image quality of arterial walls (84.3 vs. 83.2%). The mean relative changes in arterial enhancement between baseline and arterial phase images showed no statistically significant differences. CONCLUSION: This study demonstrated the non-inferiority of the 350 versus 400 mgI/ml iodine concentration, in terms of diagnostic efficacy, in abdominal MDCT angiography. It also confirmed the high robustness and reliability of this technique across multi-national practices.


Assuntos
Angiografia/métodos , Aorta Abdominal/diagnóstico por imagem , Aumento da Imagem/métodos , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Relação Dose-Resposta a Droga , Método Duplo-Cego , Europa (Continente) , Feminino , Humanos , Iohexol/administração & dosagem , Iopamidol/administração & dosagem , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Eur Radiol ; 20(6): 1331-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20033181

RESUMO

OBJECTIVE: To determine the practicability and potential dose saving of an imaging algorithm incorporating a pulsing scheme applying systolic data acquisition at heart rates >75 beats per minute (bpm). METHODS: Patients clinically referred for coronary computed tomography angiography (CTA) underwent cardiac CTA using either a diastolic pulsing window (30-70%) or a narrow systolic pulsing window (150 ms at 300 ms). Independent investigators retrospectively determined image quality (1, excellent, to 5, unreadable) and derived effective radiation exposure. RESULTS: Among all 101 subjects (62 +/- 2 years, 59% male) the predicted decrease in the best reconstruction interval for diastolic phases was 12 ms per 1 bpm [95% confidence interval (CI): -13.5 to -11.2] and -1.9 ms for systolic phases (95% CI: -3.2 to -0.62, p = 0.004), independent of age, gender and body mass index (BMI). The systolic pulsing strategy in 47 subjects (23 subjects >75 bpm) resulted in significantly lower radiation exposure (4.97 +/- 2.3 vs 9.38 +/- 5.5 mSv, p < 0.001 for systolic versus diastolic, respectively), whereas there was no difference with respect to image quality or heart rate (p = 0.65 and p = 0.74, respectively). CONCLUSIONS: Our results suggest that a systolic window for tube current modulation in subjects with higher heart rates represents a reliable tool to ensure high image quality at significantly lower dose in patients undergoing routine cardiac CTA.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...