Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Talanta ; 74(4): 717-23, 2008 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371699

RESUMO

Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to determine the distribution of the trace elements zinc, copper and lead in insular, central and hippocampal areas of thin tissue sections (thickness 20microm) through an entire human brain hemisphere. For the investigation of the tissue samples, a commercial laser ablation system was coupled to a double-focusing sector field ICP-MS. The regions of interest of healthy brain tissue (thickness 20microm) were scanned (raster area approximately 200mm(2)) with a focused laser beam (wavelength 266nm, diameter of laser crater 200microm and laser power density 3x10(9)Wcm(-2)). The ion intensities of (64)Zn(+), (63)Cu(+) and (208)Pb(+) were measured by LA-ICP-MS within the ablated area. For quantification purposes, matrix-matched laboratory standards were prepared by means of dosing of each analyte to the pieces of brain tissue. The mass spectrometric analysis yielded inhomogeneous and largely reciprocal distributions of Zn and Cu in the selected areas of investigated brain samples. The highest concentrations of Zn and Cu with the most distinct distribution pattern were found in the hippocampus (up to 15microg g(-1)). In contrast to zinc and copper, for lead, a more homogeneous distribution throughout all regions examined was found at a low concentration (in the ngg(-1) range) level within the analytical range of LA-ICP-MS.


Assuntos
Cobre/análise , Hipocampo/química , Chumbo/análise , Espectrometria de Massas/métodos , Zinco/análise , Idoso , Feminino , Humanos , Lasers , Padrões de Referência
2.
Anal Bioanal Chem ; 390(2): 571-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17962924

RESUMO

The ability of a quadrupole-based ICP-MS with an octopole collision cell to obtain precise and accurate measurements of isotope ratios of magnesium, calcium and potassium was evaluated. Hydrogen and helium were used as collision/reaction gases for ICP-MS isotope ratio measurements of calcium and potassium in order to avoid isobaric interference with the analyte ions from (mainly) argon ions 40Ar+ and argon hydride ions 40Ar1H+. Mass discrimination factors determined for the isotope ratios 25Mg/24Mg, 40Ca/44Ca and 39K/41K under optimized experimental conditions varied between 0.044 and 0.075. The measurement precisions for 25Mg/24Mg, 40Ca/44Ca and 39K/41K were found to be 0.09%, 0.43% and 1.4%, respectively. This analytical method that uses ICP-QMS with a collision cell to obtain isotope ratio measurements of magnesium, calcium and potassium was used in routine mode to characterize biological samples (nutrient solution and small amounts of digested plant samples). The mass spectrometric technique was employed to study the dynamics of nutrient uptake and translocation in barley plants at different root temperatures (10 degrees C and 20 degrees C) using enriched stable isotopes (25Mg, 44Ca and 41K) as tracers. For instance, the mass spectrometric results of tracer experiments demonstrated enhanced 25Mg and 44Ca uptake and translocation into shoots at a root temperature of 20 degrees C 24 h after isotope spiking. In contrast, results obtained from 41K tracer experiments showed the highest 41K contents in plants spiked at a root temperature of 10 degrees C.

3.
Artigo em Inglês | MEDLINE | ID: mdl-17885277

RESUMO

Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed.


Assuntos
Química Encefálica , Encéfalo/anatomia & histologia , Espectrometria de Massas/métodos , Metais Pesados/análise , Animais , Encéfalo/metabolismo , Humanos , Lasers , Metais Pesados/metabolismo , Microquímica , Caramujos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
4.
Anal Chem ; 79(16): 6074-80, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17622184

RESUMO

Quantitative imaging analysis of endogenous an exogenous elements throughout entire organisms is required for studies of bioavailability, transport processes, distribution, contamination and to monitor environmental risks using indicator organisms. An imaging mass spectrometric technique using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) was developed to analyze selenium and metal distributions in longitudinal sections (thickness, 100 microm) of entire slugs (genus arion). Slugs were fed with either a placebo or solutions containing 1000 microg mL(-1) Se. Samples (raster area, 25 mmx45 mm) were scanned together with synthetic matrix-matched standards with a focused beam of a Nd:YAG laser (wavelength, 266 nm; diameter of laser crater, 50 microm; laser power density, 3x10(9) W cm(-2)) in a large laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a double focusing sector field ICPMS. Ion intensities of selenium (78Se+, 82Se+) were measured together with 13C+, 63Cu+, and 64Zn+ within the entire tissue section. The regression coefficient of the calibration curve was 0.998. Inhomogeneous distributions for Se but also for C, Cu, and Zn were found. Selenium was enriched in the kidney (150 microg g(-1) in Se-treated animals versus 15 microg g(-1) in the placebo-treated animal, respectively) and in the digestive gland (200 microg g(-1) versus 25 microg g(-1)). Highest Se concentrations were detected in the gut of Se-treated slugs (250 microg g(-1)), and additional Se occurred in the skin of these animals. Cu was enriched in the heart and the mucous ventral skin. Interestingly, in addition to the localization in the digestive gland, Zn was detected only in the dorsal skin but not the ventral skin. The developed analytical technique allows the quantitative imaging of selenium together with selected metals in thin sections of biological tissue with limits of detection at the submicrogram per gram range.


Assuntos
Cobre/análise , Monitoramento Ambiental/métodos , Espectrometria de Massas/métodos , Selênio/farmacocinética , Zinco/análise , Animais , Gastrópodes , Lasers , Espectrometria de Massas/normas , Distribuição Tecidual
5.
Anal Chem ; 77(10): 3208-16, 2005 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15889910

RESUMO

Laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) was used to produce images of element distribution in 20-microm thin sections of human brain tissue. The sample surface was scanned (raster area approximately 80 mm(2)) with a focused laser beam (wavelength 213 nm, diameter of laser crater 50 microm, and laser power density 3 x 10(9) W cm(-2)) in a cooled laser ablation chamber developed for these measurements. The laser ablation system was coupled to a double-focusing sector field ICPMS. Ion intensities of 31P+, 32S+, 56Fe+, 63Cu+, 64Zn+, 232Th+, and 238U+ were measured within the area of interest of the human brain tissue (hippocampus) by LA-ICPMS. The quantitative determination of copper, zinc, uranium, and thorium distribution in thin slices of the human hippocampus was performed using matrix-matched laboratory standards. In addition, a new arrangement in solution-based calibration using a micronebulizer, which was inserted directly into the laser ablation chamber, was applied for validation of synthetic laboratory standard. The mass spectrometric analysis yielded an inhomogeneous distribution (layered structure) for P, S, Cu, and Zn in thin brain sections of the hippocampus. In contrast, Th and U are more homogeneously distributed at a low-concentration level with detection limits in the low-nanogram per gram range. The unique analytical capability and the limits of LA-ICPMS will be demonstrated for the imaging of element distribution in thin cross sections of brain tissue from the hippocampus. LA-ICPMS provides new information on the spatial element distribution of the layered structure in thin sections of brain tissues from the hippocampus.


Assuntos
Química Encefálica , Cobre/análise , Hipocampo/química , Espectrometria de Massas/métodos , Zinco/análise , Calibragem , Humanos , Lasers , Fósforo/análise , Enxofre/análise , Tório/análise , Urânio/análise
6.
Anal Bioanal Chem ; 374(6): 1091-5, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12458425

RESUMO

It is well known that ammunition containing depleted uranium (DU) was used by NATO during the Balkan conflict. To evaluate the origin of DU (the enrichment of natural uranium or the reprocessing of spent nuclear fuel) it is necessary to directly detect the presence of activation products ((236)U, (239)Pu, (240)Pu, (241)Am, and (237)Np) in the ammunition. In this work the analysis of actinides by alpha-spectrometry was compared with that by inductively coupled plasma mass spectrometry (ICP-MS) after selective separation of ultratraces of transuranium elements from the uranium matrix. (242)Pu and (243)Am were added to calculate the chemical yield. Plutonium was separated from uranium by extraction chromatography, using tri- n-octylamine (TNOA), with a decontamination factor higher than 10(6); after elution plutonium was determined by ICP-MS ((239)Pu and (240)Pu) and alpha-spectrometry ((239+240)Pu) after electroplating. The concentration of Pu in two DU penetrator samples was 7 x 10(-12) g g(-1) and 2 x 10(-11) g g(-1). The (240)Pu/(239)Pu isotope ratio in one penetrator sample (0.12+/-0.04) was significantly lower than the (240)Pu/(239)Pu ratios found in two soil samples from Kosovo (0.35+/-0.10 and 0.27+/-0.07). (241)Am was separated by extraction chromatography, using di(2-ethylhexyl)phosphoric acid (HDEHP), with a decontamination factor as high as 10(7). The concentration of (241)Am in the penetrator samples was 2.7 x 10(-14) g g(-1) and <9.4 x 10(-15) g g(-1). In addition (237)Np was detected at ultratrace levels. In general, ICP-MS and alpha-spectrometry results were in good agreement. The presence of anthropogenic radionuclides ((236)U, (239)Pu,(240)Pu, (241)Am, and (237)Np) in the penetrators indicates that at least part of the uranium originated from the reprocessing of nuclear fuel. Because the concentrations of radionuclides are very low, their radiotoxicological effect is negligible.

7.
Fresenius J Anal Chem ; 370(5): 527-33, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11496982

RESUMO

This paper describes an analytical procedure for determining the stoichiometry of BaxSr1-xTiO3 perovskite layers using inductively coupled plasma mass spectrometry (ICP-MS). The analytical results of mass spectrometry measurements are compared to those of X-ray fluorescence analysis (XRF). The performance and the limits of solid-state mass spectrometry analytical methods for the surface analysis of thin BaxSr1-xTiO3 perovskite layers sputtered neutral mass spectrometry (SNMS)--are investigated and discussed.

8.
Fresenius J Anal Chem ; 370(5): 534-40, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11496983

RESUMO

Laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a very efficient and sensitive technique for the direct analysis of solids. In this work the capability of LA-ICP-MS was investigated for determination of trace elements in high-purity graphite. Synthetic laboratory standards with a graphite matrix were prepared for the purpose of quantifying the analytical results. Doped trace elements, concentration 0.5 microg g(-1), in a laboratory standard were determined with an accuracy of 1% to +/- 7% and a relative standard deviation (RSD) of 2-13%. Solution-based calibration was also used for quantitative analysis of high-purity graphite. It was found that such calibration led to analytical results for trace-element determination in graphite with accuracy similar to that obtained by use of synthetic laboratory standards for quantification of analytical results. Results from quantitative determination of trace impurities in a real reactor-graphite sample, using both quantification approaches, were in good agreement. Detection limits for all elements of interest were determined in the low ng g(-1) concentration range. Improvement of detection limits by a factor of 10 was achieved for analyses of high-purity graphite with LA-ICP-MS under wet plasma conditions, because the lower background signal and increased element sensitivity.

9.
Fresenius J Anal Chem ; 370(5): 618-23, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11496995

RESUMO

To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.


Assuntos
Cálcio/análise , Ferro/análise , Isótopos/análise , Radioisótopos/análise , Selênio/análise , Cálcio/química , Ferro/química , Isótopos/química , Espectrometria de Massas , Radioisótopos/química , Selênio/química
10.
Fresenius J Anal Chem ; 370(5): 637-40, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11496998

RESUMO

The capability of LA-ICP-MS for determination of trace impurities in transparent quartz glasses was investigated. Due to low or completely lacking absorption of laser radiation, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) proves difficult on transparent solids, and in particular the quantification of measurement results is problematic in these circumstances. Quartz glass reference materials of various compositions were studied by using a Nd:YAG laser system with focused laser radiation of wavelengths of 1064 nm, 532 nm and 266 nm, and an ICP-QMS (Elan 6000, Perkin Elmer). The influence of ICP and laser ablation conditions in the analysis of quartz glasses of different compositions was investigated, with the laser power density in the region of interaction between laser radiation and solid surface determining the ablation process. The trace element concentration was determined via calibration curves recorded with the aid of quartz glass reference materials. Under optimized measuring conditions the correlation coefficients of the calibration curves are in the range of 0.9-1. The relative sensitivity factors of the trace elements determined in the quartz glass matrix are 0.1-10 for most of the trace elements studied by LA-ICP-MS. The detection limits of the trace elements in quartz glass are in the low ng/g to pg/g range.

11.
Fresenius J Anal Chem ; 370(5): 612-7, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11496994

RESUMO

As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF-ICP-MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF-ICP-MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4 x 10(-4) and 10(-3) counts per atom were achieved for 238U in DF-ICP-QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2 x 10(-4) and 1.4 x 10(-4), respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 microg L(-1) NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/P38U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10(-5) to 10(-3). Results obtained with ICP-MS, alpha- and gamma-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.


Assuntos
Espectrometria de Massas/métodos , Liberação Nociva de Radioativos , Poluentes Radioativos do Solo/análise , Nebulizadores e Vaporizadores , Centrais Elétricas , Sensibilidade e Especificidade , Ucrânia
12.
Fresenius J Anal Chem ; 367(5): 407-13, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11227466

RESUMO

The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95-110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02-0.38 microg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 microg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5-10 microg/L) to test the analytical method and the recoveries were 95-105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1-5 mg) for method development and quality control.


Assuntos
Meio Ambiente , Metais/análise , Oligoelementos/análise , Animais , Calibragem , Bovinos , Cabelo/química , Humanos , Fígado/química , Espectrometria de Massas , Metais Alcalinos/análise , Metais Alcalinoterrosos/análise , Metais Pesados/análise , Plantas Tóxicas , Padrões de Referência , Valores de Referência , Ródio/normas , Sensibilidade e Especificidade , Nicotiana/química
13.
Fresenius J Anal Chem ; 368(5): 490-5, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11227531

RESUMO

The increasing emission of Pt-group metals from automobile catalytic converters requires the development of highly sensitive procedures for ultratrace analysis of environmental and biological systems. Tree bark, located close to motorway or industrial areas, was utilised as a substrate for collection of airborne particulate matter and samples after digestion (microwave assisted dissolution with HNO3 and HCl) were analysed by ICP mass spectrometry. The study targeted Pt and other metallic contaminants and involved analysis of some 57 tree bark samples using both quadrupole and double-focusing sector field ICP mass spectrometers. Detection limits for platinum determination in tree bark were 0.03 ng/g (DF-ICP-MS) and 0.2 ng/g (ICP-QMS). The platinum content of the bark samples ranged from 0.07-5.4 ng/g.


Assuntos
Poluentes Atmosféricos/análise , Extratos Vegetais/análise , Platina/análise , Oligoelementos/análise , Cidades , Espectrometria de Massas/métodos , Espectrometria de Massas/normas , População Rural , Sensibilidade e Especificidade , Árvores
14.
Fresenius J Anal Chem ; 368(2-3): 173-81, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11220576

RESUMO

Because multielement trace analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is often limited by the lack of suitable reference materials with a similar matrix composition, a novel quantification strategy using solution calibration was developed. For mass spectrometric multielement determination in geological samples a quadrupole-based LA-ICP-MS is coupled with an ultrasonic nebulizer (USN). In order to arrange matrix matching the standard solutions are nebulized with a USN during solution calibration and simultaneously a blank target (e.g. lithium borate) is ablated with a focused laser beam. The homogeneous geological samples were measured using the same experimental arrangement where a 2% nitric acid is simultaneously nebulized with the USN. Homogeneous targets were prepared from inhomogeneous geological samples by powdering, homogenizing and fusing with a lithium borate mixture in a muffle furnace at 1050 degrees C. Furthermore, a homogeneous geological glass was also investigated. The quantification of analytical results was performed by external calibration using calibration curves measured on standard solutions. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS, measured concentrations in homogeneous geological targets were also corrected with relative sensitivity coefficients (RSCs) determined using one standard solution only. The analytical results of LA-ICP-MS on various geological samples are in good agreement with the reference values and the results of other trace analytical methods. The relative standard deviation (RSD) for trace element determination (N = 6) is between 2 and 10%.

15.
Fresenius J Anal Chem ; 368(1): 23-30, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11220826

RESUMO

The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

16.
Fresenius J Anal Chem ; 368(1): 79-87, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11220836

RESUMO

Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1-11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower microg/g range (from 0.03 microg/g for Lu, Ta and Th to 7.3 microg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (lambda: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 x 10(9) W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.

17.
Anal Chem ; 71(15): 3077-84, 1999 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21662899

RESUMO

The direct injection high efficiency nebulizer (DIHEN) was explored for the ultrasensitive determination of long-lived radionuclides ((226)Ra, (230)Th, (237)Np, (238)U, (239)Pu, and (241)Am) and for precise isotope analysis by inductively coupled plasma mass spectrometry (ICPMS). The DIHEN was used at low solution uptake rates (1-100 µL/min) without a spray chamber. Optimal sensitivity (e.g., (238)U, 230 MHz/ppm; (230)Th, 190 MHz/ppm; and (239)Pu, 184 MHz/ppm) was achieved at low nebulizer gas flow rates (0.16 L/min), high rf power (1450 W), and low solution uptake rates (100 µL/min). The optimum parameters varied slightly for the two DIHENs tested. The detection limits of long-lived radionuclides in aqueous solutions varied from 0.012 to 0.11 ng/L. The sensitivity of the DIHEN was improved by a factor of 3 to 5 compared with that of a microconcentric nebulizer (MicroMist used with a minicyclonic spray chamber at a solution uptake rate of 85 µL/min) and a factor of 1.5 to 4 compared with that of a conventional nebulizer (cross-flow used with a Scott type spray chamber at a solution uptake rate of 1 mL/min). The precision of the DIHEN ranged from 0.5 to 1.7% RSD (N = 3) for all measurements at the 10 ng/L concentration level (∼3 pg sample size). The sensitivity decreased to 10 MHz/ppm at a solution uptake rate of 1 µL/min. The precision was about 5% RSD at a sample size of 30 fg for each long-lived radionuclide by the DIHEN-ICPMS method. The oxide to atom ratios were less than 0.05 (except ThO(+)/Th(+) ) and decreased under the optimum conditions in the following sequence: ThO(+)/Th(+) > UO(+)/U(+) > NpO(+)/Np(+) > PuO(+)/Pu(+) > AmO(+)/Am(+) > RaO(+)/Ra(+). Atomic and oxide ions were used as analyte ions for ultratrace and isotope analyses of long-lived radionuclides in environmental and radioactive waste samples. The analytical methods developed were applied to the determination of long-lived radionuclides and isotope ratio measurements in different radioactive waste and environmental samples using the DIHEN in combination with quadrupole ICPMS. For instance, the (240)Pu/(239)Pu isotope ratio was measured in a radioactive waste sample at a plutonium concentration of 12 ng/L. This demonstrates a main advantage of DIHEN-ICPMS compared with α-spectrometry, which cannot be used to selectively determine (239)Pu and (240)Pu because of similar α energies (5.244 and 5.255 MeV, respectively).

18.
Anal Bioanal Chem ; 355(7-8): 831-5, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15045274

RESUMO

A radiofrequency (rf) powered planar magnetron glow discharge ion source has been designed and coupled to a double-focusing mass spectrometer. Superposition of the electrical field of the plasma in the cathode dark space and the magnetic field obtained from a ring-shaped magnet located directly behind the sample (cathode) form the electron traps and enhance the sputtering and ionization efficiency of the ion source. In order to establish optimum conditions for the trace analysis of nonconducting materials, mass spectrometric studies have been carried out on the ion signal intensities and energy distributions of analyte and discharge gas ions depending on pressure.

19.
Anal Bioanal Chem ; 355(5-6): 626-32, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15045328

RESUMO

For the trace analysis of impurities in thick ceramic layers of a solid oxide fuel cell (SOFC) sensitive solid-state mass spectrometric methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and radiofrequency glow discharge mass spectrometry (rf-GDMS) have been developed and used. In order to quantify the analytical results of LA-ICP-MS, the relative sensitivity coefficients of elements in a La(0.6)Sr(0.35)MnO(3) matrix have been determined using synthetic standards. Secondary ion mass spectrometry (SIMS) - as a surface analytical method - has been used to characterize the element distribution and diffusion profiles of matrix elements on the interface of a perovskite/Y-stabilized ZrO(2) layer. The application of different mass spectrometric methods for process control in the preparation of ceramic layers for the SOFC is described.

20.
Anal Bioanal Chem ; 353(3-4): 267-70, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15048480

RESUMO

Grain and grain boundary diffusion coefficients in alumina scales on FeCrAl-based ODS alloys have been determined. The boundary diffusion-coefficients have been derived by combining gravimetrically determined growth rate data with SEM and TEM analyses of the oxide scale microstructure. The diffusion coefficients determined have been used as input parameters for a computer model describing the oxygen isotope exchange between grain and grain boundary in the alumina scale which forms during a two-stage oxidation using (18)O-tracers. This comparison of the calculated tracer profiles with profiles determined experimentally by SIMS allows the estimation of the lattice diffusion coefficient of oxygen in the alumina scale.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA