MAGMA ; 37(2): 169-183, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38197908

RESUMO

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Assuntos
Imageamento por Ressonância Magnética , Imãs , Imageamento por Ressonância Magnética/métodos
2.
Nat Methods ; 20(12): 2048-2057, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38012321

RESUMO

To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m-1, 900 T m-1s-1) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35-0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Cabeça , Neuroimagem , Razão Sinal-Ruído
3.
Magn Reson Med ; 90(6): 2592-2607, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37582214

RESUMO

PURPOSE: A 128-channel receive-only array for brain imaging at 7 T was simulated, designed, constructed, and tested within a high-performance head gradient designed for high-resolution functional imaging. METHODS: The coil used a tight-fitting helmet geometry populated with 128 loop elements and preamplifiers to fit into a 39 cm diameter space inside a built-in gradient. The signal-to-noise ratio (SNR) and parallel imaging performance (1/g) were measured in vivo and simulated using electromagnetic modeling. The histogram of 1/g factors was analyzed to assess the range of performance. The array's performance was compared to the industry-standard 32-channel receive array and a 64-channel research array. RESULTS: It was possible to construct the 128-channel array with body noise-dominated loops producing an average noise correlation of 5.4%. Measurements showed increased sensitivity compared with the 32-channel and 64-channel array through a combination of higher intrinsic SNR and g-factor improvements. For unaccelerated imaging, the 128-channel array showed SNR gains of 17.6% and 9.3% compared to the 32-channel and 64-channel array, respectively, at the center of the brain and 42% and 18% higher SNR in the peripheral brain regions including the cortex. For R = 5 accelerated imaging, these gains were 44.2% and 24.3% at the brain center and 86.7% and 48.7% in the cortex. The 1/g-factor histograms show both an improved mean and a tighter distribution by increasing the channel count, with both effects becoming more pronounced at higher accelerations. CONCLUSION: The experimental results confirm that increasing the channel count to 128 channels is beneficial for 7T brain imaging, both for increasing SNR in peripheral brain regions and for accelerated imaging.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Razão Sinal-Ruído , Imagens de Fantasmas , Neuroimagem/métodos , Desenho de Equipamento
4.
Magn Reson Med ; 85(5): 2490-2506, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33231890

RESUMO

PURPOSE: To achieve highly accelerated submillimeter resolution T2 -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume selection and variable flip angles (VFA). METHODS: GRASE imaging has disadvantages in that (a) k-space modulation causes T2 blurring by limiting the number of slices and (b) a VFA scheme results in partial success with substantial SNR loss. In this work, accelerated GRASE with controlled T2 blurring is developed to improve a point spread function (PSF) and temporal signal-to-noise ratio (tSNR) with a large number of slices. To this end, the VFA scheme is designed by minimizing a trade-off between SNR and blurring for functional sensitivity, and a new GRASE-optimized random encoding, which takes into account the complex signal decays of T2 and T2∗ weightings, is proposed by achieving incoherent aliasing for constrained reconstruction. Numerical and experimental studies were performed to validate the effectiveness of the proposed method over regular and VFA GRASE (R- and V-GRASE). RESULTS: The proposed method, while achieving 0.8 mm isotropic resolution, functional MRI compared to R- and V-GRASE improves the spatial extent of the excited volume up to 36 slices with 52%-68% full width at half maximum (FWHM) reduction in PSF but approximately 2- to 3-fold mean tSNR improvement, thus resulting in higher BOLD activations. CONCLUSIONS: We successfully demonstrated the feasibility of the proposed method in T2 -weighted functional MRI. The proposed method is especially promising for cortical layer-specific functional MRI.


Assuntos
Encéfalo , Imageamento Tridimensional , Encéfalo/diagnóstico por imagem , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Razão Sinal-Ruído
5.
Magn Reson Med ; 84(6): 3128-3145, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32557752

RESUMO

PURPOSE: Functional MRI (fMRI) at the mesoscale of cortical layers and columns requires both sensitivity and specificity, the latter of which can be compromised if the imaging method is affected by vascular artifacts, particularly cortical draining veins at the pial surface. Recent studies have shown that cerebral blood volume (CBV) imaging is more specific to the actual laminar locus of neural activity than BOLD imaging using standard gradient-echo EPI sequences. Gradient and spin-echo (GRASE) BOLD imaging has also shown greater specificity when compared with standard gradient-echo EPI BOLD. Here we directly compare CBV and BOLD contrasts in high-resolution imaging of the primary motor cortex for laminar functional MRI in four combinations of signal labeling, CBV using slice-selective slab-inversion vascular space occupancy (VASO) and BOLD, each with 3D gradient-echo EPI and zoomed 3D-GRASE image readouts. METHODS: Activations were measured using each sequence and contrast combination during a motor task. Activation profiles across cortical depth were measured to assess the sensitivity and specificity (pial bias) of each method. RESULTS: Both CBV imaging using gradient-echo 3D-EPI and BOLD imaging using 3D-GRASE show similar specificity and sensitivity and are therefore useful tools for mesoscopic functional MRI in the human cortex. The combination of GRASE and VASO did not demonstrate high levels of sensitivity, nor show increased specificity. CONCLUSION: Three-dimensional EPI with VASO contrast and 3D-GRASE with BOLD contrast both demonstrate sufficient sensitivity and specificity for laminar functional MRI to be used by neuroscientists in a wide range of investigations of depth-dependent neural circuitry in the human brain.


Assuntos
Mapeamento Encefálico , Volume Sanguíneo Cerebral , Encéfalo , Circulação Cerebrovascular , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética
6.
Magn Reson Med ; 82(1): 377-386, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30883901

RESUMO

PURPOSE: To develop a novel, simultaneous multi-slice (SMS) reconstruction that extends an inter-slice leakage constraint to intra-slice aliasing with a virtual slice concept for artifact reduction. METHODS: Inter-slice leakage constraint has been used for SMS reconstruction that mitigates leakage artifacts from the adjacent slices. In this work, the leakage constraint is extended to more general framework that includes SMS and parallel MRI as special cases by viewing intra-slice aliasing artifacts from undersampling as virtual slices while imposing data fidelity to ensure the measurement consistency. In this way, the reconstruction makes it feasible to directly estimate the individual slices from the undersampled SMS acquisition as a one-step method. The performance of the extended method is evaluated with data acquired using 2D GRE and EPI sequences. RESULTS: Compared to a two-step method that performs slice unaliasing followed by inplane unaliasing, the proposed one-step method reduces aliasing artifacts by employing the extended leakage constraint while lowering the noise amplification by improving the conditioning for the inverse problem. CONCLUSIONS: The proposed one-step method takes advantage of virtual slices as additional encoding power for improved image quality. We successfully demonstrated that the proposed one-step method minimizes a trade-off between aliasing artifacts and amplified noises over the two-step method.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Humanos
7.
Neuroimage ; 164: 155-163, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28213116

RESUMO

Encoding higher spatial resolution in simultaneous multi-slice (SMS) EPI is highly dependent on gradient performance, high density receiver coil arrays and pulse sequence optimization. We simulate gradient amplitude and slew rate determination of EPI imaging performance in terms of minimum TE, echo spacing (ES) and spatial resolution. We discuss the effects of image zooming in pulse sequences that have been used for sub-millimeter resolutions and the trade-offs in using partial Fourier and parallel imaging to reduce TE, PSF and ES. Using optimizations for SMS EPI pulse sequences with available gradient and receiver hardware, experimental results in ultra-high resolution (UHR) (0.45-0.5mm isotropic) SMS-EPI fMRI and mapping ocular dominance columns (ODC) in human brain at 0.5 mm isotropic resolution are demonstrated. We discuss promising future directions of UHR fMRI.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Encéfalo/fisiologia , Dominância Ocular/fisiologia , Humanos , Imageamento Tridimensional/métodos
8.
Neuroimage ; 122: 281-7, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26241682

RESUMO

Cerebrospinal fluid (CSF) dynamics have been mostly studied with cardiac-gated phase contrast MRI combining signal from many cardiac cycles to create cine-phase sampling of one time-averaged cardiac cycle. The relative effects of cardiac and respiratory changes on CSF movement are not well understood. There is possible respiration-driven movement of CSF in ventricles, cisterns, and subarachnoid spaces which has not been characterized with velocity measurements. To date, commonly used cine-phase contrast techniques of velocity imaging inherently cannot detect respiratory velocity changes since cardiac-gated data acquired over several minutes randomizes respiratory phase contributions. We have developed an extremely fast, real-time, and quantitative MRI technique to image CSF velocity in simultaneous multi-slice (SMS) echo planar imaging (EPI) acquisitions of 3 or 6 slice levels simultaneously over 30s and observe 3D spatial distributions of CSF velocity. Measurements were made in 10 subjects utilizing a respiratory belt to record respiratory phases and visual cues to instruct subjects on breathing rates. A protocol is able to measure velocity within regions of brain and basal cisterns covered with 24 axial slices in 4 minutes, repeated for 3 velocity directions. These measurements were performed throughout the whole brain, rather than in selected line regions so that a global view of CSF dynamics could be visualized. Observations of cardiac and breathing-driven CSF dynamics show bidirectional respiratory motion occurs primarily along the central axis through the basal cisterns and intraventricular passageways and to a lesser extent in the peripheral Sylvian fissure with little CSF motion present in subarachnoid spaces. During inspiration phase, there is upward (inferior to superior) CSF movement into the cranial cavity and lateral ventricles and a reversal of direction in expiration phase.


Assuntos
Encéfalo/fisiologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Líquido Cefalorraquidiano/fisiologia , Imagem Ecoplanar/métodos , Respiração , Ventrículos Cerebrais/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Processamento de Sinais Assistido por Computador
9.
Magn Reson Med ; 70(6): 1500-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24130105

RESUMO

PURPOSE: Simultaneous multi-slice (SMS) echo planar imaging (EPI) is incorporated into two-dimensional (2D) arterial spin labeling (ASL) imaging to produce more slices for measuring perfusion in a larger region of the brain than currently possible with multi-slice EPI. METHODS: Pulsed ASL (PASL) preparations using FAIR and QUIPSS II techniques were combined with SMS-EPI. Testing was performed in four subjects at 3 Tesla. Multiband slice acceleration factors (MB) from MB-2 to MB-5 using 40 averages were evaluated. Comparisons were made quantitatively to PASL 2D EPI and qualitatively to PASL 3D GRASE. RESULTS: In the 12 slice data set, spatial SNR for the perfusion weighted images averaged across subjects was 3.28 and 3.44 for the two sequential MB-1 acquisitions as control comparison, 3.25 for MB-2 and 2.98 for MB-3. The temporal SNR averaged 1.01 and 0.99 for MB-1, 0.89 for MB-2, and 0.78 for MB-3. For whole-brain spatial coverage, the 20 slice data sets could be acquired in narrower time windows, from 874 ms using EPI (MB-1) down to 196 ms using MB-5. SMS-EPI ASL differed from 3D GRASE ASL, which can use background suppression and has less susceptibility artifact as a CPMG SE sequence. CONCLUSION: SMS-EPI has a major advantage over EPI-based ASL imaging by increasing slice coverage without lengthening the acquisition time window.


Assuntos
Algoritmos , Artérias Cerebrais/anatomia & histologia , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Vision Res ; 50(15): 1445-51, 2010 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-20417656

RESUMO

PROBLEM: To investigate the independent role of spatial frequency on component motion integration. METHOD: Two Type II plaids were presented at varying spatial frequencies. The velocity vectors of the underlying components were constructed so that predicted speed and direction from the components; the Intersection of Constraints; the vector average; and distortion products, remained constant for each of the two plaids across spatial frequency. Perceived direction was measured using a method of adjustment. RESULTS: Perceived direction changed as a function of spatial frequency, approaching the pattern direction only at spatial frequencies greater than 0.5cpd. CONCLUSIONS: Spatial frequency has an independent effect on the component integration stage that determines perceived pattern motion direction. The results appear to reflect the resolution of orientation for recombination of the components at low spatial frequencies. These results have implications for motion modelling and possible clinical applications.


Assuntos
Percepção de Movimento/fisiologia , Humanos , Reconhecimento Visual de Modelos , Estimulação Luminosa/métodos