Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Anaesthesiol Clin Pharmacol ; 36(3): 386-390, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33487908

RESUMO

BACKGROUND AND AIMS: Current concerns related to the anesthetic neurotoxicity have brought a renewed interest in regional anesthesia. Regional anesthesia reduces the need for opioids and inhalational anesthetics. The immaturity of the neonatal and infant nervous system may render them more prone to neurotoxicity. We describe our technique of anesthesia, which minimizes the exposure to general anesthetics and reduces airway instrumentation because the operability is rendered by the regional block. MATERIAL AND METHODS: This was a retrospective case series of neonates and infants undergoing common surface surgeries. We describe our technique of anesthesia where regional blocks are the mainstay. We also put up the data pertaining to block effectiveness, technique, end-tidal sevoflurane concentration and complications. RESULTS: One thousand patients, including neonates and infants, received central and peripheral nerve blockade. The failure rate in upper extremity blocks 0% without complications. 86.12% were given under ultrasonography (USG) guidance and 13.89% were given with peripheral nerve stimulation. The failure rate of sciatic block single shot and continuous was 0%. 92.53% were given with USG guidance while 7.46% received sciatic with nerve stimulation technique. Failure rate of caudal epidural block was 0. 78% requiring a rescue analgesic, 1.4% had blood in the needle. Out of the caudals, 33.33% were done with USG guidance and 66.67% blocks were given with traditional techniques. Out of the 322 penile + ring blocks given by traditional method, 1 block failed requiring rescue analgesics. The mean sevoflurane concentration was 1.2 +/- 0.32. CONCLUSION: It is feasible to conduct surface surgeries in the most vulnerable population such as neonates and infants under regional anesthesia without intubation and airway instrumentation.

3.
Paediatr Anaesth ; 28(3): 287-290, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29285839

RESUMO

BACKGROUND: Children that have had a meningomyelocele repair often present for hip and bilateral lower limb surgeries. Due to vertebral, epidural, and nerve root abnormalities, placement of epidural catheter is difficult. AIMS: We aim to describe the potential role of ultrasound in delineating the most appropriate intervertebral space for central neuroaxial blocks in these patients. METHODS: Twelve children with previous meningomyelocele repair, in the age group of 6-12 years posted for hip or bilateral lower limb surgeries were included. After induction of anesthesia, an ultrasound scan was done with the patient in the left lateral position. The central neuroaxial block was performed in the most appropriate intervertebral space seen on transverse scan of spine. These patients were studied with regard to visibility of the osseous framework of the spine, the anterior and posterior dural complexes, ease of insertion of catheter, evidence of dural puncture, and possibility of identification of the extent of peri-incisional fibrosis. RESULTS: One case required 2 attempts. There was no evidence of dural puncture. We could confirm the soft tissue shadow, the osseous framework, and the anterior and posterior dural complexes in all 12 patients. Ultrasonography guided in selecting the most appropriate space for epidural catheter placement. CONCLUSION: Ultrasound guidance aids in identification of normal intervertebral space and explicitly shows the abnormal space. It can be used as an aid to differentiate between normal and abnormal space in post-meningomyelocele repair.


Assuntos
Anestesia Epidural/métodos , Extremidade Inferior/cirurgia , Meningomielocele/cirurgia , Ultrassonografia de Intervenção/métodos , Criança , Pré-Escolar , Espaço Epidural/diagnóstico por imagem , Feminino , Pé/cirurgia , Quadril/cirurgia , Humanos , Masculino , Procedimentos Ortopédicos/métodos , Coluna Vertebral/diagnóstico por imagem
4.
Paediatr Anaesth ; 27(10): 1010-1014, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28795472

RESUMO

BACKGROUND: Caudo-lumbar and caudo-thoracic epidural anesthesia is an established technique that carries a low risk of dural puncture or spinal cord trauma in infants. Traditionally catheter advancement is based on external measurements. However, malpositioning of catheters are known to occur. We hypothesized that caudal-epidural catheters inserted under real-time ultrasound guidance may be more accurate than the accuracy of the measurements traditionally used for their placement. METHODS: We studied 25 patients, aged 2 days to 5 months, posted for abdominal or thoracic surgery, receiving general anesthesia followed by caudo-epidural continuous block. External measurement defined as the distance from the caudal space and the surgically congruent vertebral level was measured in centimeters with the back gently flexed. Subsequently, a caudo-epidural block was performed in the same position. The epidural catheter insertion was followed under real-time ultrasound guidance till the predetermined vertebral level was reached. The actual length placed under real-time ultrasound scan was defined as the actual length. The high-frequency probe was placed longitudinal and paramedian to the spine. The vertebral level was determined by identifying the lumbosacral junction in longitudinal saggital view and counting the vertebrae up from L5. The catheter length at the skin was compared with the length recorded by external measurement. RESULTS: The actual length placed under real-time ultrasound scan were consistently longer than the external distance between the caudal space and selected vertebral level. The mean values of ultrasound were higher than the mean values of external measurement with a difference of 4.28 cm. Accuracy was not affected by age or affected by the selected vertebral level in the age group we studied. CONCLUSION: We conclude that catheters placed under ultrasound guidance are more accurate than the traditional method developed before the advent of ultrasound in young infants.


Assuntos
Anestesia Epidural/instrumentação , Anestesia Epidural/métodos , Ultrassonografia de Intervenção/métodos , Anestesia Caudal/instrumentação , Anestesia Caudal/métodos , Espaço Epidural/diagnóstico por imagem , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...