Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Agric Food Chem ; 67(50): 13840-13847, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-30945545

RESUMO

The use of headspace thin-film microextraction devices (SPMESH) for parallel extraction of trace-level volatiles prior to direct analysis in real-time mass spectrometry (DART-MS) has been reported previously, in which volatiles were extracted from samples in multi-well plates. In this report, we demonstrate that headspace extraction of volatiles by SPMESH sheets can be performed directly from planar surfaces. When coupled with DART-MS, this approach yields volatile mass spectral images with at least 4 mm resolution. When samples were spotted onto general-purpose silica gel thin-layer chromatography (TLC) plates, the SPMESH extraction could reach equilibrium within 2-4 min and 48 samples could be extracted and analyzed in 14 min. Because volatilization of analytes from TLC plates was very rapid, SPMESH extraction was delayed by the addition of 5% polyethylene glycol. Good linearity was achieved in the microgram per liter to milligram per liter range for four odorants (3-isobutyl-2-methoxypyrazine, linalool, methyl anthranilate, and o-aminoacetophenone) in several matrices (water, 10% ethanol, juice, and grape macerate) using 5 µL sample sizes. Detection limits as low as 50 pg/spot (10 µg/L in grape macerate) could be achieved. In contrast to many reports on headspace solid-phase microextraction, negligible matrix effects were observed for ethanol and grape macerates compared to water. SPMESH can preserve volatile images from planar surfaces, and SPMESH-DART-MS from TLC plates is well-suited for rapid trace volatile analysis, especially with small sample sizes.


Assuntos
Cromatografia em Camada Fina/métodos , Microextração em Fase Sólida/métodos , Vitis/química , Compostos Orgânicos Voláteis/química , Compostos Orgânicos Voláteis/isolamento & purificação , Espectrometria de Massas/métodos
2.
Anal Chem ; 90(22): 13806-13813, 2018 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-30362714

RESUMO

Headspace (HS) extraction and preconcentration of volatiles by solid-phase microextraction (SPME) can improve the sensitivity and selectivity of ambient ionization-mass spectrometry approaches like direct analysis in real time (DART), but previous approaches to HS-SPME-DART-MS have been challenging to automate. This report describes the production of inexpensive, reusable solid-phase mesh-enhanced sorption from headspace (SPMESH) sheets by laser-etching mesh patterns into poly(dimethylsiloxane) (PDMS) sheets. Parallel headspace extraction of volatiles from multiple samples can be achieved by positioning the SPMESH sheets over multiwell plates and then attaching to a positioning stage for automated DART-MS quantitation. Using three representative odorants (3-isobutyl-2-methoxypyrazine, linalool, and methyl anthranilate), we achieved µg/L-ng/L detection limits with SPMESH-DART-MS, with the DART-MS step requiring only 17 min for 24 samples. Acceptable repeatability (24% or less day-to-day variation) and excellent recovery from a grape matrix (99-106%) could be achieved. Through use of a Teflon gasket and stainless steel spacers, cross-contamination between the headspaces of adjacent wells could be limited to roughly 1%. Optimum SPMESH extraction and desorption parameters were determined by response surface methodology. In summary, sheet-based SPMESH provides a sensitive, readily automated approach for coupling with DART-MS and achieving high-throughput trace-level volatile analyses.

3.
Dalton Trans ; 46(47): 16465-16473, 2017 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-29144523

RESUMO

Emerging applications that exploit the properties of nanoparticles for biotechnology require that the nanoparticles be biocompatible or support biological recognition. These types of particles can be produced through syntheses that involve biologically relevant molecules (proteins or natural extracts, for example). Many of the protocols that rely on these molecules are performed without a clear understanding of the mechanism by which the materials are produced. We have investigated a previously described reaction in which gold nanoparticles are produced from the reaction of chloroauric acid and proteins in solution. We find that modifications to the starting conditions can alter the product from the expected solution-suspended colloids to a product where colloids are formed within a solid, fibrous protein structure. We have interrogated this synthesis, exploiting the change in products to better understand this reaction. We have evaluated the kinetics and products for 7 different proteins over a range of concentrations and temperatures. The key factor that controls the synthetic outcome (colloid or fiber) is the concentration of the protein relative to the gold concentration. We find that the observed fibrous structures are more likely to form at low protein concentrations and when hydrophilic proteins are used. An analysis of the reaction kinetics shows that AuNP formation occurs faster at lower protein (fiber-forming) concentrations than at higher protein (colloid-forming) concentrations. These results contradict traditional expectations for reaction kinetics and protein-fiber formation and are instructive of the manner in which proteins template gold nanoparticle production.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Nanotecnologia/métodos , Proteínas/química , Animais , Técnicas de Química Sintética , Cinética
4.
J Agric Food Chem ; 65(42): 9353-9359, 2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-28965401

RESUMO

Ambient ionization mass spectrometric (AI-MS) techniques like direct analysis in real time (DART) offer the potential for rapid quantitative analyses of trace volatiles in food matrices, but performance is generally limited by the lack of preconcentration and extraction steps. The sensitivity and selectivity of AI-MS approaches can be improved through solid-phase microextraction (SPME) with appropriate thin-film geometries, for example, solid-phase mesh-enhanced sorption from headspace (SPMESH). This work improves the SPMESH-DART-MS approach for use in food analyses and validates the approach for trace volatile analysis for two compounds in real samples (grape macerates). SPMESH units prepared with different sorbent coatings were evaluated for their ability to extract a range of odor-active volatiles, with poly(dimethylsiloxane)/divinylbenzene giving the most satisfactory results. In combination with high-resolution mass spectrometry (HRMS), detection limits for SPMESH-DART-MS under 4 ng/L in less than 30 s acquisition times could be achieved for some volatiles [3-isobutyl-2-methoxypyrazine (IBMP) and ß-damascenone]. A comparison of SPMESH-DART-MS and SPME-GC-MS quantitation of linalool and IBMP demonstrates excellent agreement between the two methods for real grape samples (r2 ≥ 0.90), although linalool measurements appeared to also include isobaric interference.


Assuntos
Espectrometria de Massas/métodos , Vitis/química , Compostos Orgânicos Voláteis/química , Aromatizantes/química , Aromatizantes/isolamento & purificação , Microextração em Fase Sólida , Compostos Orgânicos Voláteis/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA