Rev Sci Instrum ; 92(3): 033309, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820015

RESUMO

Characteristics and performance of a time of flight (TOF) spectrometer developed for performing fission mass distribution studies are presented. The spectrometer contains two TOF arms based on multi-wire proportional counters (MWPCs). Each arm has two MWPCs to form a start-stop detection system for TOF measurements. The start detector has an active area of 4 × 4 cm2. The stop detector is a two-dimensional position sensitive MWPC with an active area of 16 × 11 cm2. Salient features of the MWPCs are the use of reduced sub-millimeter wire pitches of 0.635 and 0.317 mm in the electrodes along with the use of gold plated tungsten wires of diameters 10 and 20 µm. A delay line for position electrodes is prepared using chip inductors and capacitors. Ten different configurations of MWPC were investigated for the start detector, which involved the use of three and four electrode geometries, use of different wire pitches, and use of aluminized mylar for timing electrodes. Performance results close to micro-channel plate detectors have been observed with some designs of MWPC, displaying rise times better than 2 ns with an estimated inherent time resolution of ∼100 ps FWHM. A position resolution of ∼1 mm (FWHM) has been observed. Design features of the MWPCs and their test performance results are described in this article.

2.
MethodsX ; 3: 542-550, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27818948

RESUMO

Thin carbon-backed isotopically enriched 208Pb targets were required for our experiment aimed to study the reaction dynamics for 48Ti + 208Pb system, populating the near super-heavy nucleus 256Rf, through mass-energy correlation of the fission fragments. Purity and thickness of the targets are of utmost importance in such studies as these factors have strong influence on the measurement accuracy of mass and energy distribution of fission fragments. 208Pb targets with thickness ranging from 60 µg/cm2 to 250 µg/cm2 have been fabricated in high vacuum environment using physical vapor deposition method. Important points in the method are as follows: •208Pb was deposited using resistive heating method, whereas carbon (backing foil) deposition was performed by using the electron beam bombardment technique.•Different characterization techniques such as Particle Induced X-ray Emission (PIXE), Energy Dispersive X-Ray Fluorescence (EDXRF) and Rutherford Backscattering Spectrometry (RBS) were used to assert the purity and thickness of the targets.•These targets have successfully been used to accomplish our experimental objectives.

3.
Rev Sci Instrum ; 80(12): 123502, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20059140

RESUMO

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm(2) and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.