Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesth Intensive Care ; 35(2): 173-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17444304

RESUMO

Fluids balanced to avoid acid-base disturbances may be preferable to saline, which causes metabolic acidosis in high volume. We evaluated acid-base and bio-energetic effects of haemodilution with a crystalloid balanced on physical chemical principles, versus crystalloids causing metabolic acidosis or metabolic alkalosis. Anaesthetised, mechanically ventilated Sprague-Dawley rats (n=32, allocated to four groups) underwent six exchanges of 9 ml crystalloid for 3 ml blood. Exchange was with one of three crystalloids with strong ion difference (SID) values of 0, 24 (balanced) and 40 mEq/l. Controls did not undergo haemodilution. Mean haemoglobin concentration fell to approximately 50 g/l after haemodilution. With SID 24 mEq/l fluid, metabolic acid-base remained unchanged. Dilution with SID 0 mEq/l and 40 mEq/l fluids caused a progressive metabolic acidosis and alkalosis respectively. Standard base excess (SBE) and haemoglobin concentration were directly correlated in the SID 0 mEq/l group (R2 = 0.61), indirectly correlated in the SBE 40 mEq/l group (R2 = 0.48) and showed no correlation in the SID 24 mEq/l group (R2 = 0.003). There were no significant differences between final ileal values of CO2 gap, nucleotides concentration, energy charge, or luminal lactate concentration. SID 40 mEq/l crystalloid dilution caused a significant rise in subcutaneous lactate. In this group mean kidney ATP concentration was significantly less than controls and renal energy charge significantly lower than SID 0 mEq/l and control groups. We conclude that a crystalloid SID of 24 mEq/l provides balanced haemodilution. Bio-energetic perturbations with higher SID haemodilution may be more severe and need further investigation.


Assuntos
Equilíbrio Ácido-Base/efeitos dos fármacos , Metabolismo Energético/efeitos dos fármacos , Hemodiluição/métodos , Soluções Isotônicas/farmacologia , Equilíbrio Hidroeletrolítico , Acidose/induzido quimicamente , Difosfato de Adenosina/metabolismo , Monofosfato de Adenosina/metabolismo , Trifosfato de Adenosina/metabolismo , Alcalose/induzido quimicamente , Animais , Soluções Cristaloides , Hemoglobinas/efeitos dos fármacos , Concentração de Íons de Hidrogênio/efeitos dos fármacos , Soluções Isotônicas/administração & dosagem , Ácido Láctico/metabolismo , Masculino , Ratos , Ratos Sprague-Dawley
2.
Neurosurgery ; 46(5): 1131-8; discussion 1138-9, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10807245

RESUMO

OBJECTIVE: To evaluate, in a prospective, observational study, whether bilateral monitoring of jugular bulb oxyhemoglobin saturation (SjO2), in addition to standard monitoring, results in modification of the management of severe head trauma. METHODS: The patients underwent bilateral jugular bulb cannulation and observation at 8-hour intervals, during which SjO2 was measured and the neurological condition and physiological variables were assessed. The study group was responsible for evaluating whether the physician's decision-making process was influenced by the detection of SjO2 abnormalities. The SjO2 discrepancy in simultaneous bilateral samples was also evaluated to determine whether it interfered with the interpretation of data and with clinical decision-making. The SjO2-related complications were monitored. RESULTS: Thirty patients underwent 319 observations. In 96% of patients, SjO2 was normal or high and had no influence on the diagnostic or therapeutic strategies. Treatment decisions were dictated by changes in clinical status and in intracranial and cerebral perfusion pressure. When these parameters were abnormal, treatment was administered, even if SjO2 was normal (101 observations). Conversely, when SjO2 was the only detected abnormality (34 observations), no treatment was administered. Abnormally low SjO2 values, caused by hypovolemia and hypocapnia, were detected in 3.4% of observations and actually modified the management. The discrepancies in simultaneous bilateral samples were substantial and gave rise to relevant interpretation problems. Fifteen percent of jugular catheters showed evidence of bacterial colonization. CONCLUSION: Intermittent SjO2 monitoring did not substantially influence the management of severe head trauma. Therefore, recommendation for its routine use in all patients seems inadvisable, and indications for this invasive method should no longer be defined on the basis of experts' opinions, but rather on randomized, prospective studies.


Assuntos
Lesões Encefálicas/terapia , Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Hipóxia Encefálica/diagnóstico , Monitorização Fisiológica/instrumentação , Oximetria/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Lesões Encefálicas/sangue , Cuidados Críticos , Feminino , Humanos , Hipóxia Encefálica/sangue , Pressão Intracraniana/fisiologia , Veias Jugulares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
3.
J Neurosurg ; 88(4): 769-72, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9525727

RESUMO

The authors describe a patient with severe head injury and sepsis who became acutely quadriplegic 3 days postinjury because of a critical illness polyneuropathy (CIP) and critical illness myopathy (CIM), which resolved rapidly after treatment of the underlying infection. In only 3 days the patient developed septic shock together with flaccid quadriplegia and absent deep tendon reflexes with no clinical or radiological evidence of central nervous system deterioration. Neurophysiological studies showed an acute axonal sensorimotor polyneuropathy, whereas the clinical course strongly suggested a concurrent myopathy. A severe Staphylococcus epidermidis infection accompanied by bacteremia was treated and the patient recovered fully within a few days. Although the case described here is unique because of its very early onset and rapid resolution, CIP and CIM are frequent complications of sepsis and multiple organ failure. The authors suggest that severely head injured patients with sepsis should be evaluated for CIP and CIM when presenting with unexplained muscle weakness or paralysis.


Assuntos
Quadriplegia/etiologia , Quadriplegia/fisiopatologia , Doença Aguda , Adulto , Antibacterianos/uso terapêutico , Traumatismos Craniocerebrais/complicações , Traumatismos Craniocerebrais/cirurgia , Estado Terminal , Humanos , Masculino , Doenças Musculares/complicações , Doenças do Sistema Nervoso Periférico/complicações , Complicações Pós-Operatórias , Choque Séptico/etiologia , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/tratamento farmacológico
4.
Intensive Care Med ; 22(10): 1070-4, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8923072

RESUMO

OBJECTIVE: To assess the results of a 5-year experience with bedside burr hole for intracranial pressure (ICP) monitoring performed by intensive care physicians. DESIGN: Prospective, observational study in 120 patients. SETTING: A general-neurologic Intensive Care Unit in a University Hospital. PATIENTS: Patients admitted for acute neural lesion requiring ICP monitoring. METHOD: A 2.71 mm burr hole was made with positioning of a subarachnoid screw, through which a miniaturized fiberoptic, tip transducer device (Camino) was advanced and inserted 2 mm in the frontal cortex. MAIN RESULTS: Over a 5-year period 120 patients, mainly with severe head trauma, underwent ICP monitoring. None of the planned patients was excluded because of technical difficulties. No life-threatening complications were reported, and the overall morbidity rate related to the ICP monitor was 3.3%. Complications were infectious in nature, with 2.5% wound infections and 0.8% meningitis. Although seven patients bled when opening the dura, no intracranial hematomas were recorded due to the ICP monitor. The fiberoptic device was left in place for 5 +/- 1.6 (SD) days (range 1-12 days). Five patients (4.1%) required catheter substitution due to breakage of the system components (fiberoptics). CONCLUSIONS: Bedside insertion of a ICP monitor performed by intensive care physicians is a safe procedure, with a complication rate comparable to other series published by neurosurgeons. The overall morbidity rate is comparable to, or even lower than, that caused by central vein catheterization.


Assuntos
Craniotomia , Cuidados Críticos/métodos , Pressão Intracraniana , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Craniotomia/efeitos adversos , Craniotomia/instrumentação , Craniotomia/métodos , Falha de Equipamento , Tecnologia de Fibra Óptica , Hospitais com mais de 500 Leitos , Humanos , Itália , Corpo Clínico Hospitalar , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...