Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Radiat Res ; 199(6): 535-555, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310880

RESUMO

Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.


Assuntos
Bioensaio , Coleta de Amostras Sanguíneas , Estudos Retrospectivos , Citocinese , Espectroscopia de Ressonância de Spin Eletrônica
2.
Radiat Res ; 199(6): 571-582, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057983

RESUMO

The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semiautomated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.


Assuntos
Citocinese , Liberação Nociva de Radioativos , Humanos , Relação Dose-Resposta à Radiação , Citocinese/efeitos da radiação , Testes para Micronúcleos/métodos , Bioensaio/métodos , Radiometria/métodos
3.
Radiat Res ; 199(6): 556-570, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37018160

RESUMO

After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.


Assuntos
Aberrações Cromossômicas , Liberação Nociva de Radioativos , Humanos , Estudos Retrospectivos , Radiometria/métodos , Bioensaio/métodos , Cromossomos , Relação Dose-Resposta à Radiação
4.
Health Phys ; 117(6): 598-605, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31124834

RESUMO

In September and October 2017, elevated atmospheric ruthenium contamination was measured in several European countries. The most probable origin of this release of radionuclides was reconstructed to be the Southern Ural region. During that time, five workers from a German company stayed up to 2 wk about 120 km from the Chelyabinsk region in Ekaterinburg, Russia. No clinical symptoms were reported during or after the suspected radiation exposure, and no internal contamination was found in whole-body measurements. However, to investigate radiation protection issues and to clarify the workers' situation in order to reassure them, as they planned to continue working in Ekaterinburg, our laboratory was urgently requested by the company's occupational physician to perform biodosimetry using dicentric analysis to determine if the workers have been exposed to radiation by incorporation of radionuclides. The workers' dicentric yields have been compared to reference data of background frequencies in unexposed individuals, but, as it is not reasonable to quantify individual absorbed radiation doses from internalized beta emitters due to various confounding factors, individual dose estimation has not been performed. Dicentric frequencies for two workers differed significantly from the mean laboratory background level, which could have been induced by an exposure to incorporated radionuclides due to beta emissions by Ru or to gamma irradiation by the decay nuclide of Ru. However, the maximum absorbed radiation doses calculated for a resident in the Ru-contaminated area during that time does not correspond to the observed dicentric frequencies. It cannot be excluded that their dicentric frequencies were already elevated before September 2017, potentially induced by an earlier radiation exposure to diagnostic x rays or even by chance.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Doenças Profissionais/etiologia , Exposição Ocupacional/análise , Radioisótopos de Rutênio/análise , Adulto , Análise Citogenética , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/epidemiologia , Doenças Profissionais/patologia , Exposição Ocupacional/efeitos adversos , Doses de Radiação , Federação Russa/epidemiologia , Radioisótopos de Rutênio/efeitos adversos
5.
Radiat Res ; 189(6): 579-596, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29613823

RESUMO

Dicentric chromosome analysis (DCA) is the gold standard for individual radiation dose assessment. However, DCA is limited by the time-consuming phytohemagglutinin (PHA)-mediated lymphocyte activation. In this study using human peripheral blood lymphocytes, we investigated PHA-associated whole genome gene expression changes to elucidate this process and sought to identify suitable gene targets as a means of meeting our long-term objective of accelerating cell cycle kinetics to reduce DCA culture time. Human peripheral whole blood from three healthy donors was separately cultured in RPMI/FCS/antibiotics with BrdU and PHA-M. Diluted whole blood samples were transferred into PAXgene tubes at 0, 12, 24 and 36 h culture time. RNA was isolated and aliquots were used for whole genome gene expression screening. Microarray results were validated using qRT-PCR and differentially expressed genes [significantly (FDR corrected) twofold different from the 0 h value reference] were analyzed using several bioinformatic tools. The cell cycle positions and DNA-synthetic activities of lymphocytes were determined by analyzing the correlated total DNA content and incorporated BrdU level with flow cytometry after continued BrdU incubation. From 42,545 transcripts of the whole genome microarray 47.6%, on average, appeared expressed. The number of differentially expressed genes increased linearly from 855 to 2,858 and 4,607 at 12, 24 and 36 h after PHA addition, respectively. Approximately 2-3 times more up- than downregulated genes were observed with several hundred genes differentially expressed at each time point. Earliest enrichment was observed for gene sets related to the nucleus (12 h) followed by genes assigned to intracellular structures such as organelles (24 h) and finally genes related to the membrane and the extracellular matrix were enriched (36 h). Early gene expression changes at 12 h, in particular, were associated with protein classes such as chemokines/cytokines (e.g., CXCL1, CXCL2) and chaperones. Genes coding for biological processes involved in cell cycle control (e.g., MYBL2, RBL1, CCNA, CCNE) and DNA replication (e.g., POLA, POLE, MCM) appeared enriched at 24 h and later, but many more biological processes (42 altogether) showed enrichment as well. Flow cytometry data fit together with gene expression and bioinformatic analyses as cell cycle transition into S phase was observed with interindividual differences from 12 h onward, whereas progression into G2 as well as into the second G1 occurred from 36 h onward after activation. Gene set enrichment analysis over time identifies, in particular, two molecular categories of PHA-responsive gene targets (cytokine and cell cycle control genes). Based on that analysis target genes for cell cycle acceleration in lymphocytes have been identified ( CDKN1A/B/C, RBL-1/RBL-2, E2F2, Deaf-1), and it remains undetermined whether the time expenditure for DCA can be reduced by influencing gene expression involved in the regulatory circuits controlling PHA-associated cell cycle entry and/or progression at a specific early cell cycle phase.


Assuntos
Cromossomos Humanos/genética , Linfócitos/efeitos dos fármacos , Linfócitos/metabolismo , Fito-Hemaglutininas/farmacologia , Ciclo Celular/efeitos dos fármacos , Humanos , Ativação Linfocitária/efeitos dos fármacos , Linfócitos/citologia , Linfócitos/imunologia
6.
Radiat Res ; 185(5): 461-72, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27092766

RESUMO

The purpose of this work was to adapt a more advanced form of the cytokinesis-block micronucleus (CBMN) cytome assay for triage biodosimetry in the event of a mass casualty radiation incident. We modified scoring procedures for the CBMN cytome assay to optimize field deployability, dose range, accuracy, speed, economy, simplicity and stability. Peripheral blood of 20 donors was irradiated in vitro (0-6 Gy X ray, maximum photon energy 240 keV) and processed for CBMN. Initially, we assessed two manual scoring strategies for accuracy: 1. Conventional scoring, comprised of micronucleus (MN) frequency per 1,000 binucleated (BN) cells (MN/1,000 BN cells); and 2. Evaluation of 1,000, 2,000 and 3,000 cells in total and different cellular subsets based on MN formation and proliferation (e.g., BN cells with and without MN, mononucleated cells). We used linear and logistic regression models to identify the cellular subsets related closest to dose with the best discrimination ability among different doses/dose categories. We validated the most promising subsets and their combinations with 16 blind samples covering a dose range of 0-8.3 Gy. Linear dose-response relationships comparable to the conventional CBMN assay (r(2) = 0.86) were found for BN cells with MN (r(2) = 0.84) and BN cells without MN (r(2) = 0.84). Models of combined cell counts (CCC) of BN cells with and without MN (BN(+MN) and BN(-MN)) with mononucleated cells (Mono) improved this relationship (r(2) = 0.92). Conventional CBMN discriminated dose categories up to 3 Gy with a concordance between 0.96-1.0 upon scoring 1,000 total cells. In 1,000 BN cells, concordances were observed for conventional CBMN up to 4 Gy as well as BN(+MN) or BN(-MN) (about 0.85). At doses of 4-6 Gy, the concordance of conventional CBMN, BN(+MN) and BN(-MN) declined (about 0.55). We found about 20% higher concordance and more precise dose estimates of irradiated and blinded samples for CCC (Mono + BN(+MN)) after scoring 1,000 total cells. Blinded sample analysis revealed that the mean absolute difference (MAD) of dose estimates and the number of dose estimates outside the ±0.5 Gy interval based on CCC (Mono + BN(+MN)) was comparable to conventional CBMN for doses ≤4 Gy when scoring 3,000 total cells or more. At doses >4-8.3 Gy, the MAD of CCC (Mono + BN(+MN)) declined to half of the MADs observed for conventional CBMN, suggesting that the combined cell counts approach improved the discrimination ability. Conventional CBMN at 1,000 total-cell counts performed as efficiently as counting 1,000 BN cells. Discriminating and counting only BN cells with and without MN after 1,000 BN cells at ≤4 Gy revealed performances similar to conventional CBMN. After 3,000 total cells were scored, CCC (Mono + BN(+MN)) was superior to conventional CBMN at >4 Gy up to about 8 Gy. Our modification of CBMN evaluations saved time compared to the widely established semiautomated MN scoring and extended the dose range up to approximately 6 Gy for triage biodosimetry.


Assuntos
Citocinese/efeitos da radiação , Testes para Micronúcleos/métodos , Radiometria/métodos , Adulto , Apoptose/efeitos da radiação , Divisão do Núcleo Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/etiologia , Adulto Jovem
7.
Radiat Prot Dosimetry ; 168(2): 235-41, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25958413

RESUMO

Dicentric chromosome analysis (DCA) is the gold standard for individual radiation dose estimation. Two limiting factors of DCA are the time-consuming lymphocyte stimulation and proliferation using the lectin PHA-M and the upper dose limit of individual dose assessment of ∼4 Gy. By measuring the mitotic index (MI), the authors investigated systematically whether the stimulation of lymphocytes can be improved after administration of alternative (and combined) mitogens. The authors compared the lymphocyte stimulation effectiveness of the traditionally used PHA-M (from Phaseolus vulgaris) with seven cited mitogens by determination of MIs: five lectins namely CNA (concanavalin A), PW (pokeweed), LMA (Maackia amurensis), LTV (T. vulgaris), PHA-L (P. vulgaris) as well as LPS (lipopolysaccharide, Escherichia coli) and SLO (streptolysine O, Streptococcus pyogenes) were applied. The conventional protocol using PHA-M for lymphocyte stimulation proved to be superior over lower/higher PHA-M concentrations as well as seven other mitogens administered either alone or combined with SLO or LPS.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Ativação Linfocitária/efeitos dos fármacos , Linfócitos/efeitos dos fármacos , Mitógenos/farmacologia , Fito-Hemaglutininas/farmacologia , Monitoramento de Radiação/métodos , Humanos , Ativação Linfocitária/efeitos da radiação , Linfócitos/patologia , Linfócitos/efeitos da radiação , Doses de Radiação
8.
Radiat Res ; 184(1): 66-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26151173

RESUMO

The accidental gamma radiation exposure of an industrial radiography worker and the cytogenetic examination of the worker's blood lymphocytes are described here. The exposure of the worker was due to a malfunction at the entrance into the depleted uranium-shielding device of a (192)Ir source during operation. Because the source was sealed no additional beta radiation exposure was assumed. The worker's thermoluminescent dosimeter indicated an absorbed dose of 0.078 Sv, which presumably took place in December 2013. No clinical symptoms were reported in the case history after the potential exposure to radiation. Four months after the incident it was decided that biological dosimetry using dicentric chromosome and micronucleus analysis would be performed to follow radiation protection aspects and to clarify the radiation dose uncertainties for the exposed worker. Micronucleus frequency was not increased above the laboratory's control value of micronucleus background frequency of unexposed individuals. However, the observed dicentric frequency (0.003 dicentric/cell) differs significantly from the laboratory's background level of dicentric chromosomes in unexposed individuals (0.0007 dicentric/cell). Dicentric analysis in 2,048 metaphase cells resulted in an estimated dose of no more than 0.181 Gy (95% upper confidence level), not less than 0.014 Gy (95% lower confidence level) and a mean dose of 0.066 Gy (photon-equivalent whole-body exposure) based on interpolation from the laboratory's calibration curve for (60)Co gamma radiation. Since overdispersion of dicentric chromosomes (u = 9.78) indicated a heterogeneous (partial-body) exposure, we applied the Dolphin method and estimated an exposure of 2.1 Sv affecting 21% of the body volume. Because the overdispersion of dicentric chromosomes was caused by only one heavily damaged cell containing two dicentrics, it is possible that this was an incidental finding. In summary, a radiation overexposure of the radiography worker must be assumed and this case considered as a potential partial-body exposure scenario.


Assuntos
Aberrações Cromossômicas , Liberação Nociva de Radioativos , Adulto , Células Cultivadas , Feminino , Humanos , Masculino , Testes para Micronúcleos , Pessoa de Meia-Idade , Doses de Radiação , Radiografia
9.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25205835

RESUMO

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Emergências , Europa (Continente) , Humanos , Exposição à Radiação/prevenção & controle , Gestão da Segurança/organização & administração
10.
Radiat Prot Dosimetry ; 159(1-4): 87-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24743767

RESUMO

Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.


Assuntos
Planejamento em Desastres/organização & administração , Linfócitos/efeitos da radiação , Testes para Micronúcleos/métodos , Lesões por Radiação/diagnóstico , Monitoramento de Radiação/métodos , Triagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Simulação por Computador , Relação Dose-Resposta à Radiação , Feminino , Raios gama , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Lesões por Radiação/sangue , Adulto Jovem
11.
Health Phys ; 106(6): 764-71, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24776911

RESUMO

Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with 6°Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Modelos Biológicos , Radiometria/métodos , Automação , Calibragem , Relação Dose-Resposta à Radiação , Humanos
12.
Radiat Environ Biophys ; 53(2): 241-54, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24557539

RESUMO

In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.


Assuntos
Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Comportamento Cooperativo , Internet , Liberação Nociva de Radioativos , Radiometria/métodos , Triagem , Aberrações Cromossômicas/efeitos da radiação , Humanos , Doses de Radiação , Fatores de Tempo
13.
Radiat Res ; 180(2): 149-55, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23883318

RESUMO

The focus of the study is an intercomparison of laboratories' dose-assessment performances using the γ-H2AX foci assay as a diagnostic triage tool for rapid individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-4 Gy) as well as blinded test samples (0.1-6.4 Gy) were incubated at 37°C for 2 and 24 h (repair time) and sent to the participants. The foci assay was performed according to protocols individually established in participating laboratories and therefore varied. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) of estimated doses relative to the actual doses was calculated and radiation doses were merged into four triage categories reflecting clinical relevance to calculate accuracy, sensitivity and specificity. First γ-H2AX based dose estimates were reported 7 h after sample receipt. Estimates were similarly accurate for 2 and 24 h repair times, providing scope for its use in the early phase of a radiation exposure incident. Equal accuracy was achieved by scoring 20, 30, 40 or 50 cells per sample. However, MAD values of 0.5-0.7 Gy and 1.3-1.7 Gy divided the data sets into two groups, driven mainly by the considerable differences in foci yields between calibration and blind samples. Foci yields also varied dramatically between laboratories, highlighting reproducibility issues as an important caveat of the foci assay. Nonetheless, foci counts could distinguish high- and low-dose samples in all data sets and binary dose categories of clinical significance could be discriminated with satisfactory accuracy (mean 84%, ±0.03 SEM). Overall, the results suggest that the γ-H2AX assay is a useful tool for rapidly screening individuals for significant exposures that occurred up to at least 24 h earlier, and may help to prioritize cytogenetic dosimetry follow-up.


Assuntos
Bioensaio/métodos , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Histonas/metabolismo , Ensaio de Proficiência Laboratorial , Leucócitos/efeitos da radiação , Processamento de Proteína Pós-Traducional/efeitos da radiação , Radiometria/métodos , Adulto , Calibragem , Células Cultivadas/enzimologia , Células Cultivadas/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Leucócitos/enzimologia , Masculino , Fosforilação/efeitos da radiação , Lesões por Radiação/diagnóstico , Lesões por Radiação/enzimologia , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo , Triagem
14.
Radiat Res ; 180(2): 111-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23862692

RESUMO

Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.


Assuntos
Bioensaio/métodos , Cromossomos Humanos/efeitos da radiação , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Histonas/metabolismo , Ensaio de Proficiência Laboratorial , Leucócitos/efeitos da radiação , Testes para Micronúcleos , Radiometria/métodos , Adulto , Células Cultivadas/efeitos dos fármacos , Células Cultivadas/efeitos da radiação , Aberrações Cromossômicas , Citocinese/efeitos da radiação , Relação Dose-Resposta à Radiação , Expressão Gênica/efeitos da radiação , Humanos , Leucócitos/ultraestrutura , Masculino , Fosforilação , Processamento de Proteína Pós-Traducional , Lesões por Radiação/diagnóstico , Lesões por Radiação/genética , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo , Triagem/métodos
15.
Radiat Res ; 180(2): 129-37, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23862730

RESUMO

The study design and obtained results represent an intercomparison of various laboratories performing dose assessment using the dicentric chromosome analysis (DCA) as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. DCA was performed according to established protocols. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 2.4 days after sample arrival. DCA dose estimates were reported with high and comparable accuracy, with MAD values ranging between 0.16-0.5 Gy for both manual and automated scoring. No significant differences were found for dose estimates based either on 20, 30, 40 or 50 cells, suggesting that the scored number of cells can be reduced from 50 to 20 without loss of precision of triage dose estimates, at least for homogenous exposure scenarios. Triage categories of clinical significance could be discriminated efficiently using both scoring procedures.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas , Cromossomos Humanos/efeitos da radiação , Ensaio de Proficiência Laboratorial , Leucócitos/efeitos da radiação , Radiometria/métodos , Adulto , Automação , Calibragem , Cromossomos Humanos/ultraestrutura , Relação Dose-Resposta à Radiação , Dosimetria Fotográfica , Humanos , Leucócitos/ultraestrutura , Masculino , Lesões por Radiação/diagnóstico , Lesões por Radiação/genética , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo , Triagem/métodos
16.
Radiat Res ; 180(2): 120-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23862731

RESUMO

The focus of the study is an intercomparison of laboratories' dose-assessment performances using the cytokinesis-block micronucleus (CBMN) assay as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. The CBMN assay was performed according to protocols individually established and varying among participating laboratories. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 4 days after sample arrival. The CBMN dose estimates were reported with high accuracy (MAD values of 0.20-0.50 Gy at doses below 6.4 Gy for both manual and automated scoring procedures), but showed a limitation of the assay at the dose point of 6.4 Gy, which resulted in a clear dose underestimation in all cases. The MAD values (without 6.4 Gy) differed significantly (P = 0.03) between manual (0.25 Gy, SEM = 0.06, n = 4) or automated scoring procedures (0.37 Gy, SEM = 0.08, n = 5), but lowest MAD were equal (0.2 Gy) for both scoring procedures. Likewise, both scoring procedures led to the same allocation of dose estimates to triage categories of clinical significance (about 83% accuracy and up to 100% specificity).


Assuntos
Bioensaio/métodos , Ensaio de Proficiência Laboratorial , Leucócitos/efeitos da radiação , Testes para Micronúcleos/métodos , Radiometria/métodos , Adulto , Automação , Células Cultivadas/efeitos da radiação , Células Cultivadas/ultraestrutura , Citocinese/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Leucócitos/ultraestrutura , Masculino , Lesões por Radiação/diagnóstico , Lesões por Radiação/genética , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo , Triagem/métodos
17.
Radiat Res ; 180(2): 138-48, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23886340

RESUMO

The possibility of a large-scale acute radiation exposure necessitates the development of new methods that could provide rapid individual dose estimates with high sample throughput. The focus of the study was an intercomparison of laboratories' dose-assessment performances using gene expression assays. Lithium-heparinized whole blood from one healthy donor was irradiated (240 kVp, 1 Gy/min) immediately after venipuncture at approximately 37°C using single X-ray doses. Blood samples to establish calibration curves (0.25-4 Gy) as well as 10 blinded test samples (0.1-6.4 Gy) were incubated for 24 h at 37°C supplemented with an equal volume of medium and 10% fetal calf serum. For quantitative reverse transcription polymerase chain reaction (qRT-PCR), samples were lysed, stored at -20°C and shipped on ice. For the Chemical Ligation Dependent Probe Amplification methodology (CLPA), aliquots were incubated in 2 ml CLPA reaction buffer (DxTerity), mixed and shipped at room temperature. Assays were run in each laboratory according to locally established protocols. The mean absolute difference (MAD) of estimated doses relative to the true doses (in Gy) was calculated. We also merged doses into binary categories reflecting aspects of clinical/diagnostic relevance and examined accuracy, sensitivity and specificity. The earliest reported time on dose estimates was <8 h. The standard deviation of technical replicate measurements in 75% of all measurements was below 11%. MAD values of 0.3-0.5 Gy and 0.8-1.3 Gy divided the laboratories contributions into two groups. These fourfold differences in accuracy could be primarily explained by unexpected variances of the housekeeping gene (P = 0.0008) and performance differences in processing of calibration and blinded test samples by half of the contributing laboratories. Reported gene expression dose estimates aggregated into binary categories in general showed an accuracies and sensitivities of 93-100% and 76-100% for the groups, with low MAD and high MAD, respectively. In conclusion, gene expression-based dose estimates were reported quickly, and for laboratories with MAD between 0.3-0.5 Gy binary dose categories of clinical significance could be discriminated with an accuracy and sensitivity comparable to established cytogenetic assays.


Assuntos
Bioensaio/métodos , Expressão Gênica/efeitos da radiação , Ensaio de Proficiência Laboratorial , Leucócitos/efeitos da radiação , Técnicas de Amplificação de Ácido Nucleico/métodos , Radiometria/métodos , Adulto , Relação Dose-Resposta à Radiação , Eletroforese Capilar/métodos , Humanos , Leucócitos/ultraestrutura , Masculino , Microesferas , Lesões por Radiação/diagnóstico , Lesões por Radiação/genética , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Método Simples-Cego , Fatores de Tempo , Triagem
18.
Mutat Res ; 756(1-2): 174-83, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23707243

RESUMO

Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos Humanos/efeitos da radiação , Raios gama/efeitos adversos , Laboratórios/normas , Linfócitos/efeitos da radiação , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos/prevenção & controle , Automação , Radioisótopos de Cobalto , Relação Dose-Resposta à Radiação , Europa (Continente) , Humanos
19.
Radiat Prot Dosimetry ; 151(4): 621-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22923244

RESUMO

In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.


Assuntos
Proteção Radiológica , Liberação Nociva de Radioativos , Defesa Civil , Emergências , Europa (Continente) , Humanos , Liberação Nociva de Radioativos/prevenção & controle
20.
Cancer Biol Ther ; 3(1): 47-53, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14726672

RESUMO

Cell-cell and cell-extracellular matrix contacts influence cellular sensitivity to ionizing radiation. To further define the influence of these interactions on tumor cell survival and cell cycle progression after irradiation without or in combination with the phorbol ester phorbol-12-myristate-13-acetate (PMA), the radiation response of p53 wild-type A549 lung cancer cells grown on polystyrene, fibronectin (FN) or BSA was examined. Confluently growing and log-phase A549 cell cultures irradiated on FN showed significantly greater survival compared to cells irradiated on polystyrene or BSA. There was a significantly greater elevation of G(2)/M cells in FN cultures after irradiation compared to other culture conditions. PMA reduced radiation survival on all three substrata and under both log-phase and confluent culture conditions, but had no effect on the elevation of G(2)/M cells in FN cultures. Induction of Chk1 phosphorylation by irradiation was only seen in FN cultures. Chk2 and Cdk1 phosphorylation and Cdc25C expression also differed between FN and polystyrene cultures. Induction of p53 and p21 by irradiation was modulated but not inhibited by PMA, as were changes in cyclin D1 and pRb. Changes in protein expression and phosphorylation of these cell cycle regulatory proteins coincided tightly with accumulation of cells in G(2)/M after irradiation. These findings clearly demonstrate the influence of both intercellular and cell-substratum interactions on the radiation response without or in combination with PMA and differentiate between the cell survival and cell cycle effects of FN attachment.


Assuntos
Comunicação Celular/fisiologia , Sobrevivência Celular/efeitos da radiação , Matriz Extracelular/fisiologia , Fibronectinas/farmacologia , Comunicação Celular/efeitos da radiação , Linhagem Celular Tumoral , Meios de Cultura , Matriz Extracelular/efeitos da radiação , Citometria de Fluxo , Humanos , Neoplasias Pulmonares , Acetato de Tetradecanoilforbol/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...