Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(21)2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37960676

RESUMO

Low-cost, long-term measures of air pollution concentrations are often needed for epidemiological studies and policy analyses of household air pollution. The Washington passive sampler (WPS), an ultra-low-cost method for measuring the long-term average levels of light-absorbing carbon (LAC) air pollution, uses digital images to measure the changes in the reflectance of a passively exposed paper filter. A prior publication on WPS reported high precision and reproducibility. Here, we deployed three methods to each of 10 households in Ulaanbaatar, Mongolia: one PurpleAir for PM2.5; two ultrasonic personal aerosol samplers (UPAS) with quartz filters for the thermal-optical analysis of elemental carbon (EC); and two WPS for LAC. We compared multiple rounds of 4-week-average measurements. The analyses calibrating the LAC to the elemental carbon measurement suggest that 1 µg of EC/m3 corresponds to 62 PI/month (R2 = 0.83). The EC-LAC calibration curve indicates an accuracy (root-mean-square error) of 3.1 µg of EC/m3, or ~21% of the average elemental carbon concentration. The RMSE values observed here for the WPS are comparable to the reported accuracy levels for other methods, including reference methods. Based on the precision and accuracy results shown here, as well as the increased simplicity of deployment, the WPS may merit further consideration for studying air quality in homes that use solid fuels.

2.
Sci Total Environ ; 769: 144693, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33736238

RESUMO

The widespread and rapid social and economic changes from Covid-19 response might be expected to dramatically improve air quality. However, national monitoring data from the US Environmental Protection Agency for criteria pollutants (PM2.5, ozone, NO2, CO, PM10) provide inconsistent support for that expectation. Specifically, during stay-at-home orders, average PM2.5 levels were slightly higher (~10% of its multi-year interquartile range [IQR]) than expected; average ozone, NO2, CO, and PM10 levels were slightly lower (~30%, ~20%, ~27%, and ~1% of their IQR, respectively) than expected. The timing of peak anomaly, relative to the stay-at-home orders, varied by pollutant (ozone: 2 weeks before; NO2, CO: 3 weeks after; PM10: 2 weeks after); but, by 5-6 weeks after stay-at-home orders, the concentration anomalies appear to have ended. For PM2.5, ozone, CO, and PM10, no US state had lower-than-expected pollution levels for all weeks during stay-at-home-orders; for NO2, only Arizona had lower-than-expected levels for all weeks during stay-at-home orders. Our findings show that the enormous changes from the Covid-19 response have not lowered PM2.5 levels across the US beyond their normal range of variability; for ozone, NO2, CO, and PM10 concentrations were lowered but the reduction was modest and transient.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Ozônio , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Arizona , Humanos , Material Particulado/análise , SARS-CoV-2
3.
Sensors (Basel) ; 20(12)2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32560462

RESUMO

We propose a low-cost passive method for monitoring long-term average levels of light-absorbing carbon air pollution in polluted indoor environments. Building on prior work, the method here estimates the change in reflectance of a passively exposed surface through analysis of digital images. To determine reproducibility and limits of detection, we tested low-cost passive samplers with exposure to kerosene smoke in the laboratory and to environmental pollution in 20 indoor locations. Preliminary results suggest robust reproducibility (r = 0.99) and limits of detection appropriate for longer-term (~1-3 months) monitoring in households that use solid fuels. The results here suggest high precision; further testing involving "gold standard" measurements is needed to investigate accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...