Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 93(14): 5947-5953, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33793209

RESUMO

It is often necessary to prefocus particles and cells into a tight stream for subsequent separation and/or analysis in microfluidic devices. A DC electric field has been widely used for particle and cell focusing in insulator-based dielectrophoretic (iDEP) microdevices, where a large field magnitude, a high constriction ratio, and/or a long microchannel are usually required to enhance the iDEP effect. We demonstrate, in this work, an AC iDEP focusing technique, which utilizes a low-frequency AC electric field to generate both an oscillatory electrokinetic flow of the particle/cell suspension and a field direction-independent dielectrophoretic force for particle/cell focusing in a virtually "infinite" microchannel. We also develop a theoretical analysis to evaluate this focusing in terms of the AC voltage frequency, amplitude, and particle size, which are each validated through both experimental demonstration and numerical simulation. The effectiveness of AC iDEP focusing increases with the second order of electric field magnitude, superior to DC iDEP focusing with only a first-order dependence. This feature and the "infinite" channel length together remove the necessity of large electric field and/or small constriction in DC iDEP focusing of small particles.


Assuntos
Técnicas Analíticas Microfluídicas , Simulação por Computador , Eletroforese , Dispositivos Lab-On-A-Chip , Tamanho da Partícula
2.
ACS Appl Mater Interfaces ; 12(47): 52343-52353, 2020 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-33181017

RESUMO

We describe a pH-indicating material that can be directly implanted or coated on orthopedic implant surfaces to provide high-spatial-resolution pH mapping through tissue by X-ray excited luminescence chemical imaging (XELCI). This is especially useful for detecting local pH changes during treatment of implant-associated infections. The material has two layers: an X-ray scintillator layer with Gd2O2S:Eu in epoxy, which emits 620 and 700 nm light when irradiated with X-rays, and a pH indicator dye layer, which absorbs some of the 620 nm light in a pH-dependent fashion. To acquire each pixel in the image, a focused X-ray beam irradiates a small region of scintillators and the ratio of 620 to 700 nm light is acquired through the tissue. Scanning the X-ray beam across the implant surface generates high-spatial-resolution chemical measurements. Two associated challenges are (1) to make robust sensors that can be implanted in tissue to measure local chemical concentrations specifically for metal orthopedic implants and (2) to conformally coat the implant surface with scintillators and pH indicator dyes in order to make measurements over a large area. Previously, we have physically pressed or glued a pH-sensitive hydrogel sensor onto the surface of an implant, but this is impractical for imaging over large irregular device areas such as an orthopedic plate with holes and edges. Herein, we describe a chemically sensitive and biocompatible XELCI sensor material that can conformally coat the implant surface. A two-part commercial-grade epoxy resin was mixed with Gd2O2S:Eu and adhered to the titanium surface. Sugar and salt particles were added to the surface of the epoxy as it cured to create a roughened surface and increase the surface area. On this roughened surface, a secondary layer of diacrylated polyethylene glycol (PEG) hydrogel, containing a pH sensitive dye, was polymerized. This combination of epoxy-PEG layers was found to adhere well to the metal implant unlike other previously tested polymer surfaces, which delaminated when exposed to water or humidity. The focused X-ray beam enabled 0.5 mm spatial resolution through 1 cm-thick tissue. The pH sensor-coated orthopedic plate was imaged with XELCI, through tissue, with different pH levels to acquire a calibration curve. The plates were also imaged through tissue, with a low pH region on one section due to growth of a Staphylococcus aureus biofilm. A pH sensor-coated stainless-steel rod with two distinct pH regions was inserted in a rabbit tibia specimen, and the pH was imaged through both bone and soft tissue. These studies demonstrate the use of pH sensor-coated orthopedic plates and rods for mapping the local pH through tissue during biofilm formation by XELCI.


Assuntos
Materiais Biocompatíveis/química , Substâncias Luminescentes/química , Animais , Materiais Biocompatíveis/farmacologia , Biofilmes/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Compostos de Epóxi/química , Gadolínio/química , Hidrogéis/química , Concentração de Íons de Hidrogênio , Camundongos , Polietilenoglicóis/química , Próteses e Implantes , Coelhos , Aço Inoxidável/química , Staphylococcus aureus/fisiologia , Tíbia/diagnóstico por imagem , Tíbia/patologia , Titânio/química , Raios Ultravioleta
3.
Micromachines (Basel) ; 11(5)2020 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-32344887

RESUMO

Focusing particles into a tight stream is critical for many microfluidic particle-handling devices such as flow cytometers and particle sorters. This work presents a fundamental study of the passive focusing of polystyrene particles in ratchet microchannels via direct current dielectrophoresis (DC DEP). We demonstrate using both experiments and simulation that particles achieve better focusing in a symmetric ratchet microchannel than in an asymmetric one, regardless of the particle movement direction in the latter. The particle focusing ratio, which is defined as the microchannel width over the particle stream width, is found to increase with an increase in particle size or electric field in the symmetric ratchet microchannel. Moreover, it exhibits an almost linear correlation with the number of ratchets, which can be explained by a theoretical formula that is obtained from a scaling analysis. In addition, we have demonstrated a DC dielectrophoretic focusing of yeast cells in the symmetric ratchet microchannel with minimal impact on the cell viability.

4.
Analyst ; 144(9): 2984-2993, 2019 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-30888348

RESUMO

A biomedical sensor was developed to measure local pH near orthopedic implants to detect and study implant-associated infection. The sensor is read using plain radiography, a technique which is noninvasive, inexpensive, ubiquitously available in medical facilities, and routinely used in diagnosis and follow-up. The sensor comprises a radiopaque tungsten indicator pin embedded within a chemically responsive hydrogel that exhibits a pH-dependent swelling. A stainless steel well holds this hydrogel and attaches to an orthopedic plate. The local pH may be determined from the extent of hydrogel swelling by radiographically measuring the indicator position relative to the well. We calibrated the sensor in a series of standard pH buffers and tested it during bacterial growth in culture. The sensor was robust: its response was negligibly affected by changes in temperature, ionic strength within the normal physiological range, or long-term incubation with reactive oxygen species generated from hydrogen peroxide and copper. Pooled data from several sensors fabricated at different times and tested in different conditions had a root-mean-square deviation from a pH electrode reading of 0.24 pH units. Radiographic measurements were also performed in cadaveric tissue with the sensor attached to an orthopedic plate fixed to a tibia. Pin position readings varied by 100 µm between observers surveying the same radiographs, corresponding to 0.065 pH units precision in the range pH 4-8. The sensor was designed to augment standard radiographs of tissue, bony anatomy, and hardware by also indicating local chemical concentrations.


Assuntos
Resinas Acrílicas/química , Hidrogéis/química , Próteses e Implantes/microbiologia , Radiografia/métodos , Humanos , Concentração de Íons de Hidrogênio , Staphylococcus aureus/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...