Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Surg Endosc ; 36(1): 579-590, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33507384

RESUMO

BACKGROUND: When using a prosthetic material in hernia repair, the behaviour of the mesh at the peritoneal interface is especially important for implant success. Biomaterials developed for their intraperitoneal placement are known as composites and are made up of two different-structure materials, one is responsible for good integration within host tissue and the other is responsible to make contact with the viscera. This study examines the behaviour at the peritoneal level of two composites, the fully degradable Phasix-ST® and the partially degradable Symbotex®. A polypropylene mesh (Optilene®) served as control. METHODS: Sequential laparoscopy from 3 to 90 days, in a preclinical model in the New Zealand white rabbit, allowed monitoring adhesion formation. Morphological studies were performed to analyse the neoperitoneum formed in the repair process. Total macrophages were identified by immunohistochemical labelling. To identify the different macrophage phenotypes, complementary DNAs were amplified by qRT-PCR using specific primers for M1 (TNF-α/CXCL9) and M2 (MRC1/IL-10) macrophages. RESULTS: The percentage of firm and integrated adhesions remained very high in the control group over time. Both composites showed a significant decrease in adhesions at all study times and in qualitative terms were mainly loose. Significant differences were also observed from 7 days onwards between the two composites, increasing the values in Phasix over time. Neoperitoneum thickness for Phasix was significantly greater than those of the other meshes, showing mature and organized neoformed connective tissue. Immunohistochemically, a significantly higher percentage of macrophages was observed in Symbotex. mRNA expression levels for the M2 repair-type macrophages were highest for Phasix but significant differences only emerged for IL-10. CONCLUSIONS: Fewer adhesions formed to the Symbotex than Phasix implants. Ninety days after implant, total macrophage counts were significantly higher for Symbotex, yet Phasix showed the greater expression of M2 markers related to the tissue repair process.


Assuntos
Herniorrafia , Telas Cirúrgicas , Animais , Materiais Biocompatíveis , Peritônio/cirurgia , Polipropilenos , Coelhos , Aderências Teciduais
2.
World J Pediatr Congenit Heart Surg ; 13(2): 260-263, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34775849

RESUMO

Valve dysfunction is not widely recognized as a feature in newborns born to mothers with positive anti-Ro/SSA antibodies, and only scarce reports have suggested an association between rupture of the atrioventricular valve tensor apparatus and these maternal antibodies. We report the follow-up from fetal life to the time of postnatal surgery of a patient with severe tricuspid regurgitation due to a flail of the anterior tricuspid valve leaflet who was born to an anti-Ro/SSA antibodies positive mother.


Assuntos
Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Recém-Nascido , Ruptura , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
3.
Catheter Cardiovasc Interv ; 97(5): E692-E696, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33502083

RESUMO

Mitral valve perforation is a rare cause of mitral regurgitation. We present a case of a 16-year-old patient with mitral valve regurgitation after redo-cardiac surgery for recurrent subaortic stenosis. Transthoracic echocardiography revealed a mitral regurgitation with an eccentric jet causing a significant regurgitation documented by the presence of a convergence flow over the hole. This finding was corroborating by transesophageal echocardiography locating the perforation from the region of A2 scallop. Three-dimensional transesophageal echocardiography confirmed these findings and played a key role guiding the procedure. Typical approach is usually a cardiac surgical procedure based on repair the perforation, but the mitral orifice was successfully closed percutaneously using an Amplatzer Duct Occluder II (ADO II; Abbott Vascular, IL).


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Cardiopatia Reumática , Adolescente , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
J Surg Res ; 246: 26-33, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31557596

RESUMO

BACKGROUND: Tissue adhesives are a feasible option to fix a hernia repair mesh, avoiding tissue trauma of suture fixation. Classically, they are applied in the form of a drop, although novel applications such as spray are emerging. This study compares the use of a new experimental cyanoacrylate (n-butyl) in the form of a spray or drops. MATERIALS AND METHODS: Three study groups of New Zealand White rabbits were established (n = 6 each) according to the method used to fix a 5 × 3 cm polypropylene mesh in a partial abdominal wall defect model: control group (polypropylene stitches), adhesive drops group, and adhesive spray group. Morphological, immunohistochemical, and biomechanical strength studies were performed at 14 d postimplant. Collagen 1/3 gene ratio was determined by quantitative reverse transcription polymerase chain reaction. RESULTS: In the drops group, the adhesive obstructed the mesh pores and prevented tissue infiltration at the points of application. When the adhesive was applied as a spray, although more numerous, adhesive deposits were smaller and allowed for better host tissue infiltration into the mesh. The inflammatory response was similar in the adhesive groups and more intense than in the control group. Collagen 1/3 mRNA ratio was significantly higher in the spray than the control group. The mechanical resistance of the meshes was similar in all three groups. CONCLUSIONS: The application of the cyanoacrylate adhesive in the form of spray to fix polypropylene meshes in an animal model had a similar inflammatory response compared with droplet application. Neither application impacted the mechanical strength of the repaired area. An increased in collagen 1/3 ratio was found with cyanoacrylate spray compared with suture, and future studies should focus on this pathway.


Assuntos
Cianoacrilatos/administração & dosagem , Hérnia Abdominal/cirurgia , Herniorrafia/métodos , Procedimentos Cirúrgicos sem Sutura/métodos , Adesivos Teciduais/administração & dosagem , Parede Abdominal/cirurgia , Animais , Modelos Animais de Doenças , Herniorrafia/instrumentação , Coelhos , Telas Cirúrgicas , Procedimentos Cirúrgicos sem Sutura/instrumentação , Suturas , Resistência à Tração
5.
Surgery ; 167(3): 598-608, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31785825

RESUMO

BACKGROUND: In hernia surgery, soaking of meshes in antibiotics before implantation is a prophylactic strategy for minimizing the risk of infection while providing minimal, local, drug doses. This study describes the development and application of an antibacterial mesh coating comprising a carboxymethylcellulose gel loaded with rifampicin in a preclinical model of Staphylococcus aureus and S. epidermidis infection in rabbits. METHODS: Antibacterial activity and cytocompatibility (with fibroblasts) of unloaded carboxymethylcellulose gel and 0.13 mg/mL rifampicin-carboxymethylcellulose gel were assessed in vitro. Then, partial abdominal wall defects (5 × 2 cm) were created in New Zealand white rabbits (n = 34), the wound inoculated with 0.25 mL of 106 CFU Staphylococcus aureus/ S. epidermidis (n = 17 each), and the defect then repaired with a lightweight, monofilament, large pore polypropylene mesh either uncoated (n = 3) or coated with carboxymethylcellulose gel (n = 7) or rifampicin-carboxymethylcellulose gel (n = 7). By postoperative day 14, coating performance was evaluated by determining bacterial adhesion (via sonication), host tissue incorporation (via histology), macrophage response via immunostaining), and bloodstream drug diffusion (via high-performance liquid chromatography). RESULTS: In vitro, rifampicin-carboxymethylcellulose gel demonstrated great activity against Staphylococcus aureus/S. epidermidis, while being innocuous for fibroblasts. In vivo, rifampicin-carboxymethylcellulose gel-coated implants displayed full bacterial clearance and optimal tissue integration, irrespective of the strain of Staphylococcus. In contrast, uncoated and carboxymethylcellulose gel-coated implants exhibited macro/microscopic signs of infection and impaired tissue integration. Macrophage responses were less in rifampicin-carboxymethylcellulose gel implants than in uncoated mesh (Staphylococcus aureus/S. epidermidis; P < .01) and carboxymethylcellulose gel (S. epidermidis; P < .05) implants. Bloodstream levels of rifampicin were undetectable. CONCLUSION: Soaking meshes in rifampicin-carboxymethylcellulose gel inhibited effectively the bacterial adhesion to the mesh without compromising the tissue repair. This antibiotic gel constitutes an easy-to-use and effective prophylactic strategy that potentially reduce the prevalence of postoperative mesh infection.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia/instrumentação , Hérnia Abdominal/cirurgia , Herniorrafia/efeitos adversos , Telas Cirúrgicas , Infecção da Ferida Cirúrgica/prevenção & controle , Animais , Carboximetilcelulose Sódica/administração & dosagem , Modelos Animais de Doenças , Herniorrafia/instrumentação , Herniorrafia/métodos , Humanos , Masculino , Testes de Sensibilidade Microbiana , Coelhos , Rifampina/administração & dosagem , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/isolamento & purificação , Staphylococcus epidermidis/efeitos dos fármacos , Staphylococcus epidermidis/isolamento & purificação , Infecção da Ferida Cirúrgica/microbiologia
6.
Wound Repair Regen ; 27(1): 59-68, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30368971

RESUMO

In this study, rat models of wound closure by first and second intention were developed to evaluate the influence that two immunosuppressants for treating multiple sclerosis (fingolimod, azathioprine) have on wound healing. Sixty-three Sprague-Dawley rats were daily treated with fingolimod (0.6 mg/kg), azathioprine (2.5 mg/kg), or placebo (saline). Following 6 weeks of treatment, a linear incision (1.5 cm) or a circular excisional defect (diameter 1.5 cm) was made on the dorsal skin. The treatments were uninterrupted and after 7 days (incisional) or 21 days (incisional, excisional), animals were euthanized (n = 7 per group and time-point). Morphometric (wound closure), histological (stainings), and immunofluorescent studies (macrophages) were performed to evaluate the healing process. For both the incisional and excisional defects, animals treated with fingolimod exhibited a healing process equivalent to that of placebo in terms of collagenization, wound closure, and macrophage response. By comparison, groups treated with azathioprine displayed a delay in healing times which was especially evident in the excisional defect, where inflammatory reaction and collagen deposition in the repair tissue remained active by day 21. These results show that immunosuppressants with a selective mechanism of action (fingolimod) can have less impact on wound healing than their classical nonselective counterparts (azathioprine).


Assuntos
Azatioprina/farmacologia , Cloridrato de Fingolimode/farmacologia , Imunossupressores/farmacologia , Inflamação/tratamento farmacológico , Técnicas de Fechamento de Ferimentos , Cicatrização/efeitos dos fármacos , Animais , Inflamação/patologia , Masculino , Modelos Animais , Ratos , Ratos Sprague-Dawley
7.
PLoS One ; 13(11): e0206515, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30388135

RESUMO

INTRODUCTION: Lightweight (LW) polypropylene (PP) meshes better adapt to host tissue, causing less fibrosis and inflammatory responses than high-density meshes. Mesh fixation using tissue adhesives (TA) that replace conventional sutures may improve the process of hernia repair and tissue trauma. This preclinical study compares the behavior of different cyanoacrylate-based adhesives in the fixation of LW-PP meshes for hernia repair. METHODS: Partial abdominal wall defects were repaired using LW-PP Optilene meshes in New Zealand rabbits. The following groups were established according to the mesh fixation method: Suture (control), Glubran 2 (n-butyl), Ifabond (n-hexyl), SafetySeal (n-butyl) and Evobond (n-octyl). At 14, 90 and 180 days after surgery, the recovered implants were examined to assess the host tissue integration, the macrophage response and the biomechanical strength. RESULTS: All the groups showed optimal host tissue incorporation regardless of the fixation procedure. Significantly increased levels of collagen 1 and collagen 3 gene expression (p<0.001) were observed at 14 days compared to the medium- and long-term durations, where the Suture and Glubran groups showed the highest expression of collagen 1. All the adhesives increased the macrophage reaction (p<0.001) compared to sutures at all implant times. Maximal macrophage response was observed in the short-term Glubran group (p<0.01) compared to the rest of the groups. Although SafetySeal and Evobond did not reach the biomechanical resistance of sutures at 14 days, all the adhesives did reach this level in the medium- to long-term periods, providing significantly higher resistance (p<0.05). CONCLUSIONS: All the cyanoacrylates, despite inducing a significantly increased macrophage response versus sutures, showed optimal host tissue integration and long-term mechanical behavior; thus, they might be good choices for LW-PP mesh hernia repairs.


Assuntos
Cianoacrilatos , Herniorrafia , Polipropilenos , Telas Cirúrgicas , Adesivos , Animais , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Reação a Corpo Estranho/patologia , Macrófagos , Teste de Materiais , Coelhos , Suturas
8.
Ann Surg ; 268(5): 838-844, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30303875

RESUMO

OBJECTIVE: Using clinical outcomes, to validate the comprehensive complication index (CCI) as a measure of postoperative morbidity in all patients undergoing surgery at a general surgery department. BACKGROUND: The Clavien-Dindo classification (CDC) is the most widely used system to assess postoperative morbidity. The CCI is a numerical scale based on the CDC. Once validated, it could be used universally to establish and compare the real postoperative complications of each surgical procedure. METHODS: Observational prospective cohort study. All patients who underwent surgery during the 1-year study period were included. All the complications graded with the CDC and related to the initial admission, or until discharge if the patient was readmitted within 90 days of surgery, were included. Surgical procedures were classified according to the operative severity score (OSS) as minor, moderate, major, or major+. The clinical validation of the CCI was performed by assessing its correlation with 4 different clinical outcomes. RESULTS: A total of 1850 patients were included: 513 (27.7%) presented complications and 101 (5.46%) were readmitted. In the multivariate analysis, the CCI and CDC were associated with postoperative stay, prolongation of postoperative stay, readmission, and disability in all OSS groups (P < 0.001). The CCI was superior to the CDC in all models except for prolongation of stay for OSS moderate and major+. CONCLUSIONS: The CCI can be applied in all the procedures carried out at general surgery departments. It is able to determine the morbidity and allows the comparison of the outcomes at different services.


Assuntos
Complicações Pós-Operatórias/classificação , Adulto , Idoso , Avaliação da Deficiência , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Estudos Prospectivos , Índice de Gravidade de Doença
9.
J Surg Res ; 220: 30-39, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29180195

RESUMO

BACKGROUND: As an alternative to sutures, meshes used for hernia repair can be fixed using cyanoacrylate-based adhesives. Attempts to improve these adhesives include alkyl-chain lengthening to reduce their toxicity. This preclinical study compares the long-term behavior of cyanoacrylates of different chain lengths already used in hernia repair and new ones for this application. MATERIALS AND METHODS: Partial abdominal wall defects were repaired using a Surgipro mesh in 18 New Zealand White rabbits, and groups were established according to the mesh fixation method: sutures (control), Glubran 2 (n-butyl), Ifabond (n-hexyl), and the new adhesives SafetySeal (n-butyl), and Evobond (n-octyl). Six months after surgery, recovered implants were examined to assess adhesive degradation, host tissue reaction, and biomechanical strength. RESULTS: All the cyanoacrylate groups showed good host tissue incorporation in the meshes. Macrophage responses to Glubran and Ifabond were quantitatively greater compared with sutures. Cell damage caused by the adhesives was similar, and only Glubran induced significantly more damage than sutures. Significantly lower collagen 1/3 messenger RNA expression was induced by Ifabond than the remaining fixation materials. No differences were observed in collagen expression except slightly reduced collagen I deposition in Glubran/Ifabond and collagen III deposition in the suture group. Mechanical strengths failed to vary between the suture and cyanoacrylate groups. CONCLUSIONS: All cyanoacrylates showed good long-term behavior and tolerance irrespective of their long or intermediate chain length. Cyanoacrylate residues persisted at 6 mo, indicating their incomplete degradation. Biomechanical strengths were similar both for the adhesives and sutures.


Assuntos
Cianoacrilatos/uso terapêutico , Hérnia Abdominal/cirurgia , Herniorrafia/instrumentação , Suturas , Animais , Fenômenos Biomecânicos , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Cianoacrilatos/efeitos adversos , Cianoacrilatos/química , Modelos Animais de Doenças , Macrófagos/imunologia , Masculino , Coelhos , Telas Cirúrgicas
10.
Tissue Eng Part C Methods ; 23(12): 863-880, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28756748

RESUMO

In this report, we review the use of the New Zealand White rabbit as the experimental animal for several models of abdominal wall repair. For the repair of an abdominal wall defect, such as a hernia in clinical practice, multiple types of prosthetic material exist. Before their marketing, each of these biomaterials needs to be tested in a preclinical setting to confirm its biocompatibility and appropriate behavior at the different tissue interfaces. For preclinical trials, we have always used the New Zealand White rabbit as the model owing to its ease of handling and suitable size. This size allows for laparoscopic studies designed to follow the behavior in real time of a biomaterial implanted at the peritoneal interface, a delicate interface that often gives rise to complications in human practice. The size of the rabbit also offers a sufficiently large number of implant samples to be harvested for a complete battery of tests at several time points postimplant. In this review, we first describe the models established and then provide the results obtained so far using these models to test the different types of biomaterial. We end our review with a discussion of the clinical implications of these results.


Assuntos
Parede Abdominal/patologia , Cicatrização , Animais , Materiais Biocompatíveis , Fenômenos Biomecânicos , Modelos Animais de Doenças , Implantes Experimentais , Coelhos
11.
J Mater Sci Mater Med ; 28(4): 58, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28210969

RESUMO

The less traumatic use of surgical adhesives rather than sutures for mesh fixation in hernia repair has started to gain popularity because they induce less host tissue damage and provoke less postoperative pain. This study examines the host tissue response to a new cyanoacrylate (CA) adhesive (n-octyl, OCA). Partial defects (3 × 5 cm) created in the rabbit anterior abdominal wall were repaired by mesh fixation using OCA, Glubran2®(n-butyl-CA), Ifabond®(n-hexyl-CA) or sutures. Samples were obtained at 14/90 days for morphology, collagens qRT-PCR/immunofluorescence and biomechanical studies. All meshes were successfully fixed. Seroma was detected mainly in the Glubran group at 14 days. Meshes fixed using all methods showed good host tissue incorporation. No signs of degradation of any of the adhesives were observed. At 14 days, collagen 1 and 3 mRNA expression levels were greater in the suture and OCA groups, and lower in Ifabond, with levels varying significantly in the latter group with respect to the others. By 90 days, expression levels had fallen in all groups, except for collagen 3 mRNA in Ifabond. Collagen I and III protein expression was marked in the suture and OCA groups at 90 days, but lower in Ifabond at both time points. Tensile strengths were similar across groups. Our findings indicate the similar behavior of the adhesives to sutures in terms of good tissue incorporation of the meshes and optimal repair zone strength. The lower seroma rate and similar collagenization to controls induced by OCA suggests its improved behavior over the other two glues. This article deals with a preclinical study to examine different aspects of the repair process in the host of three alkyl cyanoacrylates (n-butyl (GLUBRAN 2), n-hexyl (IFABOND), and n-octyl cyanoacrylate (EVOBOND)) compared to sutures (control), in the fixation of surgical meshes for hernia repair. It goes into detail about collagen deposition in the repair zone at short and medium term. The results obtained demonstrate lower seroma rate and similar collagenization to sutures induced by the n-octyl suggesting better behavior than the other two cyanoacrylates.


Assuntos
Colágeno Tipo III/química , Colágeno Tipo I/química , Cianoacrilatos/química , Hérnia Abdominal/cirurgia , Herniorrafia/métodos , Adesivos Teciduais , Animais , Fenômenos Biomecânicos , Masculino , Desenho de Prótese , RNA Mensageiro/metabolismo , Coelhos , Seroma/metabolismo , Resistência à Tração , Cicatrização
12.
J Biomed Mater Res B Appl Biomater ; 105(2): 312-319, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26505126

RESUMO

AIMS: This study examines the intraperitoneal behavior of two cyanoacrylate tissue adhesives: Ifabond® and a new, non-marketed octyl cyanoacrylate adhesive (OCA) used for the intraperitoneal fixation of a laminar expanded polytetrafluoroethylene (ePTFE) mesh. MATERIAL AND METHODS: In 36 New Zealand White rabbits, 3 × 3 cm (n = 24) or 1.5 × 3 cm (n = 12) fragments of ePTFE mesh (Preclude® , Gore, Flagstaff, USA) were fixed to the parietal peritoneum using OCA or Ifabond® . Peritoneal fluid was obtained at the time of implant and at 2 weeks postimplant for determination of the cytokines interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α). At 14 or 90 days postsurgery, the animals were euthanized and the meshes excised to assess host tissue incorporation, the macrophage response, apoptosis and fixation strength (T-peel tensiometry). RESULTS: Peritoneal fluid IL-6 and TNF-α concentrations were similar in the OCA and Ifabond® groups. Both adhesives gave rise to adequate mesothelialization of the laminar ePTFE. Macrophage counts were similar for the two study groups, but a significantly increase in macrophage response was observed from 14 to 90 days for Ifabond® . At 90 days postimplant, apoptotic cell counts was lower for the implants fixed with OCA and a fixation strength was significantly lower for OCA. CONCLUSIONS: Despite similar cytokine levels at 2 weeks and similar host tissue incorporation observed for the meshes fixed with the two adhesives, the use of Ifabond® gave rise to a greater apoptosis rate, although this adhesive provided a stronger fixation bond. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 312-319, 2017.


Assuntos
Cianoacrilatos , Interleucina-6/metabolismo , Macrófagos/metabolismo , Teste de Materiais , Telas Cirúrgicas , Fator de Necrose Tumoral alfa/metabolismo , Animais , Cianoacrilatos/efeitos adversos , Cianoacrilatos/química , Cianoacrilatos/farmacologia , Polímeros de Fluorcarboneto/efeitos adversos , Polímeros de Fluorcarboneto/química , Polímeros de Fluorcarboneto/farmacologia , Macrófagos/patologia , Coelhos , Adesivos Teciduais/efeitos adversos , Adesivos Teciduais/química , Adesivos Teciduais/farmacologia
13.
J Surg Res ; 208: 68-83, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27993219

RESUMO

BACKGROUND: Synthetic tissue adhesives (TA) are sometimes used in hernia repair surgery. This study compares the use of a new, noncommercial, long-chain cyanoacrylate (n-octyl) TA and Ifabond for mesh fixation. MATERIALS AND METHODS: In two implant models in the rabbit, expanded polytetrafluorethylene meshes were fixed to the parietal peritoneum using a TA or tacks (intraperitoneal model), or polypropylene meshes used to repair partial abdominal wall defects were fixed with a TA or sutures (extraperitoneal model). Animals were euthanized 14 or 90 d postsurgery and implant specimens were processed for microscopy (labeling of macrophages and apoptotic cells), peritoneal fluid and biomechanical strength testing. Interleukin 6 (IL-6) and tumor necrosis factor α (TNF-α) were determinated in peritoneal fluid. RESULTS: Mesothelial cell deposition on the intraperitoneal implants fixed using the new TA and Ifabond was adequate and similar IL-6 and TNF-α levels were detected in these implants. Intraperitoneal meshes fixed with tacks showed IL-6 overexpression. Three months after surgery, macrophage and apoptotic cell rates were higher for the intraperitoneal implants fixed with Ifabond versus the new TA or tacks. In the extraperitoneal model, reduced macrophage and cell damage responses were observed in the meshes fixed with sutures versus both TA. Tensile strengths were greater for the tacks versus TA in the intraperitoneal implants and similar for the sutures and TA in the extraperitoneal implants (90 d). CONCLUSIONS: Both TA showed a good cell response in both models. Their use in an intraperitoneal location resulted in reduced tensile strength compared with the tacks. However, strengths were comparable when extraperitoneal implants were fixed with these adhesives or sutures.


Assuntos
Cianoacrilatos/uso terapêutico , Herniorrafia/instrumentação , Telas Cirúrgicas , Adesivos Teciduais/uso terapêutico , Animais , Líquido Ascítico/metabolismo , Marcação In Situ das Extremidades Cortadas , Interleucina-6/metabolismo , Macrófagos/fisiologia , Masculino , Microscopia Eletrônica de Varredura , Coelhos , Fator de Necrose Tumoral alfa/metabolismo
14.
Eur Surg Res ; 56(1-2): 32-48, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26610044

RESUMO

BACKGROUND: Bioprostheses represent a significant advance in the abdominal wall reconstruction since they become degraded until their complete elimination in the recipient organism. This study examines remodeling in the host of three noncrosslinked porcine dermal collagen biomeshes: Strattice™ (St; LifeCell Corp.), XCM Biologic® Tissue Matrix (XCM; Synthes CMF) and Protexa® (Pr; Deco Med S.R.L.). METHODS: Partial ventral hernia defects created in New Zealand White rabbits were repaired using the biomeshes that were placed in an inlay, preperitoneal position. At 14 and 90 days after implantation, explants were assessed in terms of their host tissue incorporation by morphological studies, collagen gene/protein expression (quantitative real-time PCR/immunofluorescence), macrophage response (immunohistochemistry) and biomechanical strength. RESULTS: There were no cases of mortality or infection. Among our macroscopic findings, the mesh detachment detected in one third of the Pr implants at 90 days was of note. The host tissue response to all the biomeshes was similar at both time points, with a tendency observed for their encapsulation. There were no appreciable signs of mesh degradation. The extent of host tissue infiltration and collagenization was greater for St and Pr than for XCM. Macrophages were observed in zones of inflammation and tissue infiltration inside the mesh. XCM showed a greater macrophage response at 90 days (p < 0.05). Improved tensile strength was observed for St (p < 0.05) over Pr and unrepaired defects. CONCLUSIONS: St showed the best behavior, featuring good collagenization and tensile strength while also inducing a minimal foreign body reaction.


Assuntos
Derme Acelular , Bioprótese , Hérnia Ventral/cirurgia , Telas Cirúrgicas , Animais , Colágeno/genética , Modelos Animais de Doenças , RNA Mensageiro/análise , Coelhos , Resistência à Tração
15.
J Surg Res ; 193(1): 470-82, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25150083

RESUMO

BACKGROUND: The use of a prosthetic material is the best treatment option for ventral hernia repair; one of the most frequently performed abdominal surgery procedures. This preclinical study compares the behavior of a new mesh (Parietex composite ventral patch [Ptx]) with that of two existing meshes used for ventral hernia repair. MATERIALS AND METHODS: Fifty-four New Zealand White rabbits (3000 g) were used in an experimental model of umbilical hernia repair (diameter 1.5 cm). The materials tested were: Ventralex ST hernia patch (Vent) (Bard Davol Inc, Warwick, RI) (n = 18); Proceed ventral patch (Ethicon, Somerville, NJ) (PVP) (n = 18) and Ptx (Covidien, Sofradim, Trevoux, France) (n = 18). At 3, 7, 14 d, and 6 wk after implant, peritoneal behavior and adhesion formation were assessed by sequential laparoscopy. Mesh mesothelial cover was determined by scanning electron microscopy. Host tissue ingrowth (collagens I and III) and the macrophage response were assessed by immunohistochemical labeling. Animals were euthanized at 2, 6 wk, and 6 mo after surgery. Data were compared using the Mann-Whitney U test. RESULTS: Adhesion formation from 3 d-6 wk was significantly greater (P < 0.05) for PVP compared with Vent or Ptx. Three encapsulated PVP implants showed "tissue-integrated" adhesions affecting the intestinal loops. All three implant types showed similar patterns of collagen l and III deposition. The PVP mesh elicited the greater macrophage response both at 2 wk and 6 mo. CONCLUSIONS: Ptx and Vent showed excellent mesothelialization, which led to minimum adhesion formation. The appropriate tissue integration of Ptx in the parietal neoperitoneum is likely attributable to its deployment system.


Assuntos
Colágeno/farmacologia , Hérnia Umbilical/cirurgia , Herniorrafia/instrumentação , Herniorrafia/métodos , Peritônio/cirurgia , Poliésteres/farmacologia , Telas Cirúrgicas , Parede Abdominal/patologia , Parede Abdominal/cirurgia , Animais , Hérnia Umbilical/patologia , Masculino , Teste de Materiais , Microscopia Eletrônica de Varredura , Modelos Animais , Peritônio/patologia , Peritônio/ultraestrutura , Polipropilenos/farmacologia , Próteses e Implantes , Coelhos , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle , Cicatrização
16.
BMC Surg ; 14: 70, 2014 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-25231161

RESUMO

BACKGROUND: Midline laparotomy closure carries a significant risk of incisional hernia. This study examines the behavior of two new suture materials, an elastic material, polyurethane (PUe), and a barbed polydioxanone (PDXb) suture thread in a rabbit model of midline incision closure. METHODS: Three 2-cm midline incisions were made in 68 New Zealand White rabbits. The incisions were closed by running suture using four 3/0 threads: polypropylene (PP) (Surgipro®, Covidien), PUe (Assuplus®, Assut Europe), PDX (Assufil®, Assut Europe) or PDXb (Filbloc®, Assut Europe). Animals in each suture group were euthanized 3 weeks and 6 months after surgery. Histological sections of the tissue-embedded sutures were subjected to morphological, collagen expression, macrophage response and uniaxial tensiometry studies. RESULTS: No signs of wound dehiscence or complications were observed. At 3 weeks, all sutures were surrounded by connective tissue composed mainly of collagen III. PUe showed greater collagen I expression than the other sutures. All sutures elicited a macrophage response that diminished from 3 weeks to 6 months (p < 0.001). This response was similar for the non-reabsorbable sutures (PP and PUe) yet PDXb showed a significantly greater response than the other reabsorbable suture (PDX) at 3 weeks (p < 0.01). At this early time point, the tensile strength of PUe was similar to that of control intact tissue (p > 0.05). CONCLUSION: Three weeks after surgery, PUe revealed more collagen I deposition than the remaining materials and this translated to a similar biomechanical behavior to linea alba, that could avoid the appearance of short term dehiscences and thus reduce the incidence of incisional hernia. PDXb provides no additional advantages in their behavior regarding PDX suture.


Assuntos
Parede Abdominal/cirurgia , Hérnia Abdominal/prevenção & controle , Laparotomia/métodos , Técnicas de Sutura/instrumentação , Suturas , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Teste de Materiais , Coelhos , Resistência à Tração , Cicatrização
17.
J Surg Res ; 187(2): 699-711, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24332552

RESUMO

BACKGROUND: Adhesions commonly appear in patients after abdominal surgery, with considerable individual variation in adhesion composition and severity of the repair process. Here, we address the influence of transforming growth factor (TGF)-ß3 and betaglycan in this response, in relation to TGF-ß1, in an adhesiogenic rabbit model. MATERIALS AND METHODS: Omental adhesions were recovered 3, 7, 14, and 90 d after the implantation of a polypropylene mesh on the parietal peritoneum in New Zealand White rabbits. Omentum from nonoperated animals served as control. Tissue specimens were examined for TGF-ß3 and TGF-ß1 (Western blotting, reverse transcription-polymerase chain reaction), and TGF-ß1:TGF-ß3 messenger RNA and protein expression ratios were analyzed. Immunohistochemical detection of TGF-ß3 and betaglycan was performed. RESULTS: Injury to the omentum led to mobilization of TGF-ß3 and betaglycan-expressing cells from milky spots. Fibrous zones in adhesions were simultaneous to the presence of TGF-ß1 and the membrane-bound form of betaglycan (7-d adhesions), whereas soluble betaglycan appeared in TGF-ß1-positive areas showing limited fibrosis (3-d adhesions). The elevated expression of TGF-ß3 concurrent with the presence of membrane-bound form of betaglycan was observed in zones of adipose regeneration (14-d adhesions), whereas zones of fibrous consistency were negative for TGF-ß3. CONCLUSIONS: Milky spots on the omentum contain inflammatory/immune cells positive for TGF-ß3, TGF-ß1, and betaglycan, playing a role in the damaged omentum repair. Our observations support the contribution of TGF-ß3 to tissue repair through adipose tissue regeneration and the profibrotic role of TGF-ß1 and suggest that these effects on the local wound repair response could be driven by the expression of betaglycan in its soluble or membrane-bound form.


Assuntos
Omento/lesões , Omento/metabolismo , Proteoglicanas/metabolismo , Receptores de Fatores de Crescimento Transformadores beta/metabolismo , Aderências Teciduais/metabolismo , Fator de Crescimento Transformador beta3/metabolismo , Cicatrização/fisiologia , Tecido Adiposo Branco/metabolismo , Tecido Adiposo Branco/patologia , Tecido Adiposo Branco/ultraestrutura , Animais , Modelos Animais de Doenças , Masculino , Microscopia Eletrônica de Transmissão , Omento/patologia , Omento/cirurgia , Peritônio/lesões , Peritônio/metabolismo , Peritônio/cirurgia , Polipropilenos/efeitos adversos , Proteoglicanas/genética , RNA Mensageiro/metabolismo , Coelhos , Receptores de Fatores de Crescimento Transformadores beta/genética , Transdução de Sinais/fisiologia , Telas Cirúrgicas/efeitos adversos , Aderências Teciduais/patologia , Fator de Crescimento Transformador beta1/genética , Fator de Crescimento Transformador beta1/metabolismo , Fator de Crescimento Transformador beta3/genética
18.
Surg Endosc ; 28(2): 559-69, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24045862

RESUMO

BACKGROUND: This study compared the in vitro and in vivo behaviors at the peritoneal interface of a new polymer material (Bio-A) and of two biologic non-cross-linked materials (Tutomesh [Tuto] and Strattice [St]), all biodegradable. METHODS: Omentum mesothelial cells from rabbits were seeded onto the three prosthetic materials tested. At 1, 4, 8, 16, and 24 h after implantation, mesothelial cover was performed using a scanning electron microscope (SEM). In the in vivo study, 3 × 3 cm mesh fragments were placed on the parietal peritoneum of the same rabbits and fixed at the four corners with individual stitches. The implants were randomized such that six fragments of each material were implanted in nine animals (2 per animal). Adhesion formation was quantified by sequential laparoscopy and image analysis 3, 7, and 14 days after implantation. The animals were killed at 90 days, and the meshes were subjected to microscopy and immunohistochemistry. RESULTS: The in vitro mesothelial cover was significantly greater for St than for Bio-A at each time point. The percentage of cover for St was also higher than for Tuto 16 and 24 h after seeding and higher for Tuto than for Bio-A at all time points. Compared with the biologic meshes, significantly higher adhesion percentages were recorded for Bio-A. At 90 days after implantation, differences in absorption measured as percentage of reduction in mesh thickness were detected among all the meshes. The least absorbed was St. The neoperitoneum thickness was significantly greater for the biologic meshes than for the polymer mesh, although this variable also differed significantly between St and Tuto. Macrophage counts were higher for Bio-A than for the biologic meshes. CONCLUSIONS: Greater mesothelial cover was observed in vitro for St. In vivo, adhesion formation and the macrophage response induced by Bio-A were greater than those elicited by the biologic materials. Bio-A and Tuto showed substantial biodegradation compared with St.


Assuntos
Materiais Biocompatíveis , Laparoscopia/métodos , Peritônio/cirurgia , Polímeros , Próteses e Implantes , Telas Cirúrgicas , Técnicas de Fechamento de Ferimentos/instrumentação , Animais , Modelos Animais de Doenças , Epitélio/ultraestrutura , Microscopia Eletrônica de Varredura , Peritônio/ultraestrutura , Coelhos , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle , Cicatrização
19.
PLoS One ; 8(11): e80647, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24236192

RESUMO

INTRODUCTION: Composite biomaterials designed for the repair of abdominal wall defects are composed of a mesh component and a laminar barrier in contact with the visceral peritoneum. This study assesses the behaviour of a new composite mesh by comparing it with two latest-generation composites currently used in clinical practice. METHODS: Defects (7x5cm) created in the anterior abdominal wall of New Zealand White rabbits were repaired using a polypropylene mesh and the composites: Physiomesh(TM); Ventralight(TM) and a new composite mesh with a three-dimensional macroporous polyester structure and an oxidized collagen/chitosan barrier. Animals were sacrificed on days 14 and 90 postimplant. Specimens were processed to determine host tissue incorporation, gene/protein expression of neo-collagens (RT-PCR/immunofluorescence), macrophage response (RAM-11-immunolabelling) and biomechanical resistance. On postoperative days 7/14, each animal was examined laparoscopically to quantify adhesions between the visceral peritoneum and implant. RESULTS: The new composite mesh showed the lowest incidence of seroma in the short term. At each time point, the mesh surface covered with adhesions was greater in controls than composites. By day 14, the implants were fully infiltrated by a loose connective tissue that became denser over time. At 90 days, the peritoneal mesh surface was lined with a stable mesothelium. The new composite mesh induced more rapid tissue maturation than Physiomesh(TM), giving rise to a neoformed tissue containing more type I collagen. In Ventralight(TM) the macrophage reaction was intense and significantly greater than the other composites at both follow-up times. Tensile strengths were similar for each biomaterial. CONCLUSIONS: All composites showed optimal peritoneal behaviour, inducing good peritoneal regeneration and scarce postoperative adhesion formation. A greater foreign body reaction was observed for Ventralight(TM). All composites induced good collagen deposition accompanied by optimal tensile strength. The three-dimensional macroporous structure of the new composite mesh may promote rapid tissue regeneration within the mesh.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Materiais Biocompatíveis , Telas Cirúrgicas , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/uso terapêutico , Colágeno Tipo I/genética , Colágeno Tipo I/metabolismo , Tecido de Granulação/metabolismo , Laparoscopia , Macrófagos/metabolismo , Macrófagos/patologia , Masculino , Teste de Materiais , Modelos Animais , Peritônio/metabolismo , Poliésteres/química , Poliésteres/uso terapêutico , Próteses e Implantes , Coelhos , Cicatrização
20.
J Biomech Eng ; 135(5): 51004, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24231960

RESUMO

This paper describes a method designed to model the repaired herniated human abdomen just after surgery and examine its static mechanical response to the maximum intra-abdominal pressure provoked by a physiological movement (standing cough). The model is based on the real geometry of the human abdomen bearing a large incisional hernia with several anatomical structures differentiated by MRI. To analyze the outcome of hernia repair, the surgical procedure was simulated by modeling a prosthesis placed over the hernia. Three surgical meshes with different mechanical properties were considered: an isotropic heavy-weight mesh (Surgipro®), a slightly anisotropic light-weight mesh (Optilene®), and a highly anisotropic medium-weight mesh (Infinit®). Our findings confirm that anisotropic implants need to be positioned such that the most compliant axis of the mesh coincides with the craneo-caudal direction of the body.


Assuntos
Análise de Elementos Finitos , Hérnia Abdominal , Fenômenos Mecânicos , Próteses e Implantes , Anisotropia , Fenômenos Biomecânicos , Hérnia Abdominal/cirurgia , Humanos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...