Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech Eng ; 114(3): 377-84, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1522733

RESUMO

Solutions are presented for the surface strain fields on inflated elastomeric circular diaphragms used for in vitro cell stressing experiments. It is shown, by using the method developed by Way (1934) to solve the nonlinear von Karman plate equations, that the surface strains due to bending are not negligible and that large negative radial strains arise near the clamped edge for center deflection-to-thickness ratios (w/h) less than 10. The method of Hart-Smith and Crisp (1967) was used for w/h greater than 10 to solve the nonlinear equations for symmetrical deformation of axially symmetrical rubber-like membranes. In the membrane solutions the circumferential strains drop parabolically to zero at the clamped edge of the diaphragm, while the radial strains increase slightly with the radius. The solutions for w/h greater than 10 are compared to optical measurements of in-plane displacements used to calculate the circumferential strains on the diaphragm, yielding excellent agreement with the theory.


Assuntos
Membrana Celular/fisiologia , Desenho de Equipamento/normas , Equipamentos e Provisões/normas , Borracha/normas , Estresse Mecânico , Propriedades de Superfície , Fenômenos Biomecânicos , Elasticidade , Estudos de Avaliação como Assunto
2.
Proc Inst Mech Eng H ; 204(2): 97-109, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2095150

RESUMO

The purpose of this study was to investigate if experimental strain analysis is predictive of femoral adaptation after total hip replacement (THR). Ten large adult dogs underwent unilateral THR with identical implants. Five implants were press fit for porous ingrowth fixation, and five were cemented. Four months after surgery femora were harvested. Strain gauge rosettes were applied to the femora at eight proximal locations. Femora were compressively loaded on the head of the femur or femoral component. Strain data represented three conditions: preoperative, acutely postoperative, and four-month postoperative. The unoperated femur of each dog was used to simulate preoperative and acutely postoperative behavior of the contralateral implanted femur. Strains from each condition were compared. Transverse femoral sections were obtained through the levels of the strain gauges. Fine detailed radiographs were used to quantify morphological changes. Results showed cemented and uncemented implantations produce similar trends but different amounts of bone adaptation. Adaptations were generally consistent in direction with strain perturbations caused by implantation, but the extent of adaptation did not strongly correlate with the magnitude of perturbations. Also, there was no consistent trend towards normalization of altered strains. Results suggest that strain perturbations after THR may be mechanical triggers for morphological changes, but caution is required when predicting the extent of these changes or the autoregulatory role of strain.


Assuntos
Adaptação Fisiológica/fisiologia , Cimentos Ósseos , Fêmur/fisiopatologia , Prótese de Quadril , Animais , Fenômenos Biomecânicos , Cães , Fêmur/diagnóstico por imagem , Radiografia , Estresse Mecânico
3.
J Am Vet Med Assoc ; 187(4): 389-91, 1985 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-4030473

RESUMO

The comparative ability of loop-knotted and twist-knotted cerclage to withstand tensile forces was tested. Two twist-knot devices and one loop-knot device were used to apply cerclage wires to a 5-cm diameter split circular jaw mounted on a tensile testing machine. Twist-knot devices were tested with 0.8-, 1.0-, or 1.2-mm wire, and the loop-knot device was tested with 0.8-, 1.0-, or 1.25-mm wire. For all wire sizes, the twisted knot provided greater resistance to knot failure than did the loop-knot. Of the 2 twist-knot devices, the Rhinelander wire tightener-twister produced the greatest resistance to knot failure. Knot resistance increased with increase in wire size for all devices tested.


Assuntos
Fixação Interna de Fraturas/métodos , Animais , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/veterinária , Aço Inoxidável , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA