Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Med Biol ; 68(21)2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37625437

RESUMO

This topical review focuses on Patient-Specific Quality Assurance (PSQA) approaches to stereotactic body radiation therapy (SBRT). SBRT requires stricter accuracy than standard radiation therapy due to the high dose per fraction and the limited number of fractions. The review considered various PSQA methods reported in 36 articles between 01/2010 and 07/2022 for SBRT treatment. In particular comparison among devices and devices designed for SBRT, sensitivity and resolution, verification methodology, gamma analysis were specifically considered. The review identified a list of essential data needed to reproduce the results in other clinics, highlighted the partial miss of data reported in scientific papers, and formulated recommendations for successful implementation of a PSQA protocol.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada/métodos
2.
Phys Med ; 83: 221-241, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33951590

RESUMO

PURPOSE: To perform a systematic review on the research on the application of artificial intelligence (AI) to imaging published in Italy and identify its fields of application, methods and results. MATERIALS AND METHODS: A Pubmed search was conducted using terms Artificial Intelligence, Machine Learning, Deep learning, imaging, and Italy as affiliation, excluding reviews and papers outside time interval 2015-2020. In a second phase, participants of the working group AI4MP on Artificial Intelligence of the Italian Association of Physics in Medicine (AIFM) searched for papers on AI in imaging. RESULTS: The Pubmed search produced 794 results. 168 studies were selected, of which 122 were from Pubmed search and 46 from the working group. The most used imaging modality was MRI (44%) followed by CT(12%) ad radiography/mammography (11%). The most common clinical indication were neurological diseases (29%) and diagnosis of cancer (25%). Classification was the most common task for AI (57%) followed by segmentation (16%). 65% of studies used machine learning and 35% used deep learning. We observed a rapid increase of research in Italy on artificial intelligence in the last 5 years, peaking at 155% from 2018 to 2019. CONCLUSIONS: We are witnessing an unprecedented interest in AI applied to imaging in Italy, in a diversity of fields and imaging techniques. Further initiatives are needed to build common frameworks and databases, collaborations among different types of institutions, and guidelines for research on AI.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Humanos , Itália , Imageamento por Ressonância Magnética , Física
3.
J Magn Reson Imaging ; 43(1): 213-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26013043

RESUMO

PURPOSE: To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Twenty-six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b-value ranges 0-1000 and 0-3000 s/mm(2) , respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short-term repeatability of ADC measurement was evaluated for 26 MR scanners. RESULTS: A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short-term repeatability of ADC measurement was found <2.5% for all MR scanners. CONCLUSION: A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI-derived indices before tackling single- as well as multicenter studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Imagem de Difusão por Ressonância Magnética/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Itália , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Med Phys ; 38(6): 3205-11, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21815395

RESUMO

PURPOSE: Diffusion tensor imaging (DTI) is highly sensitive to noise and improvement of radiofrequency coil technology represents a straightforward way for augmenting signal-to-noise ratio (SNR) performance in magnetic resonance imaging (MRI) scanners. The aim of this study was to characterize the dependence of DTI measurements of fractional anisotropy (FA) and mean diffusivity (MD) on the choice of head coil, comparing two head coils with different functional designs and sensitivities. METHODS: Fourteen healthy subjects underwent DTI acquisitions at 1.5 T. Every subject was scanned twice, using a standard quadrature birdcage head coil (coil-A) and an eight-channel array head coil (coil-B). FA and MD maps, estimated using both the linear least squares (LLS) and nonlinear least squares (NLLS) methods, were nonlinearly normalized into a standard space. Then, volumetric regions of interest encompassing typical white and gray matter structures [splenium of the corpus callosum (SCC), internal capsule (IC), cerebral peduncles (CP), middle cerebellar peduncles (MCP), globus pallidus (GP), thalamus (TH), caudate (CA), and putamen (PU)] were analyzed. Significant differences and trends of variation in DTI measurements were assessed by the Wilcoxon test for paired samples with and without Bonferroni correction for multiple comparisons, respectively. RESULTS: The overall SNR of coil-B was 30% higher than that of coil-A. When comparing DTI measurements (coil-B versus coil-A), mean FA values (SCC, IC, and TH), mean MD values (IC, CP, GP, and TH), FA standard deviation (CP, MCP, GP, and CA), and MD standard deviation (IC, CP, TH, and PU) resulted decreased (significant difference, p(cor) < 0.05, or trend of variation, P(uncor) < 0.05) in several gray and white matter regions of the human brain. With the exception of CP, the results in terms of revealed significant difference or trend of variation were independent of the method (LLS and NLLS) used for estimating the diffusion tensor. CONCLUSIONS: In various gray and white matter structures, the eight-channel array head coil yielded more precise and accurate measurements of DTI derived indices compared to the standard quadrature birdcage head coil.


Assuntos
Imagem de Tensor de Difusão/instrumentação , Ondas de Rádio , Adulto , Anisotropia , Encéfalo , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Adulto Jovem
5.
MAGMA ; 24(5): 285-96, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21710328

RESUMO

OBJECT: Simultaneous EEG-fMRI recordings allow the identification of haemodynamic changes induced by neuronal activity during ictal or interictal epileptiform events (IEDs). We evaluated the reproducibility of continuous EEG-fMRI (cEEG-fMRI) in patients with focal epilepsy. MATERIALS AND METHODS: We studied 15 patients with focal epilepsy (8 cryptogenic and 7 symptomatic) and frequent interictal abnormalities. Each patient underwent two cEEG-fMRI acquisitions (runs) in the same day (session) and 8 patients repeated the examination after one month. cEEG-fMRI reproducibility was defined by the existence of partially overlapping clusters between activation maps obtained from different runs. RESULTS: We detected IEDs in 40 out of 46 EEG-fMRI runs and a related significant BOLD-response in all 40 runs. A prevalent positive BOLD response was detected in 12 patients and a prevalent negative response in 3 subjects. Statistical maps included a mean of 10 significant clusters. Nearly 30% of clusters were reproducible in both intrasession and intersession comparisons, with a mean overlap of 30%. Reproducibility did not differ between positive and negative BOLD-responses. DISCUSSION: Among the reproducible clusters, those with the highest percentage of overlap were concordant with the EEG electric field in all patients and they were localized in the same lobe as the brain lesion in patients with symptomatic epilepsy. We hypothesize that reproducible clusters could be more consistently related to the irritative zone than non-reproducible ones. CONCLUSION: The evaluation of cluster reproducibility could improve our knowledge of IED-related BOLD response. Moreover, it could enhance the reliability of cEEG-fMRI to identify the irritative zone in focal epileptic patients.


Assuntos
Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Oxigênio/metabolismo , Adulto , Encéfalo/fisiopatologia , Mapeamento Encefálico/métodos , Epilepsias Parciais/sangue , Epilepsias Parciais/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
6.
Mov Disord ; 25(14): 2449-53, 2010 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-20976739

RESUMO

Seven patients with a diagnosis of Parkinson's disease (PD) and pathological gambling (PG) and 7 PD patients without PG were investigated by functional MRI and a block-design experiment with gambling-related visual cues alternating with neutral stimuli and rest periods. Compared with PD/non-PG, in PD/PG patients, several areas of increased cue-related blood oxygen level dependent (BOLD)-response were observed including bilateral anterior cingulate cortex, medial and superior frontal gyri, and precuneus, right inferior parietal lobule, and ventral striatum. The over activation of cingulate cortex and ventral striatum in PD/PG patients after the craving task is similar to that reported in addicted patients, whereas the activation of the parietal structures is probably related to the attentional network.


Assuntos
Mapeamento Encefálico , Encéfalo/irrigação sanguínea , Jogo de Azar/diagnóstico , Imageamento por Ressonância Magnética , Doença de Parkinson/diagnóstico , Idoso , Encéfalo/patologia , Sinais (Psicologia) , Feminino , Jogo de Azar/complicações , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Oxigênio/sangue , Doença de Parkinson/complicações , Estimulação Luminosa
7.
J Comput Assist Tomogr ; 34(5): 746-50, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20861779

RESUMO

Amyotrophic lateral sclerosis is characterized by degeneration of upper and lower motor neurons. Diffusion tensor imaging (DTI) indexes obtained along the corticospinal tracts distinguish ALS patients and control subjects. Diffusion tensor imaging can be estimated from at least 6 diffusion-weighted images; however an acquisition scheme with a higher number of diffusion directions allows a more robust estimation of DTI indexes. The aim of the study was to establish if a higher number of diffusion encoding gradients increases the diagnostic accuracy of DTI in ALS. We studied 18 patients and 16 control subjects acquiring 2 DTI data sets with 6 and 31 gradient orientations. The mean diffusivity and fractional anisotropy values were measured along the corticospinal tract. Mean diffusivity in ALS was significantly increased (P = 0.026) with respect to control subjects in acquisition scheme with 31 but not (P = 0.214) with 6 diffusion-weighting directions. Fractional anisotropy was significantly lower in patients both with 6 (P = 0.0036) and with 31 (P = 0.0004) diffusion-weighting directions (0.538 vs 0.588 and 0.530 vs 0.594). Fractional anisotropy receiver operating characteristic curve analysis showed a higher diagnostic accuracy by using 31 diffusion-weighting direction (85.76%) with respect to 6 directions (79.86%). Diffusion tensor imaging confirms its potentials in diagnosing ALS with a good accuracy; the acquisition scheme with a higher diffusion-weighting directions seems to better discriminate between ALS patients and control subjects.


Assuntos
Esclerose Lateral Amiotrófica/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Tratos Piramidais/patologia , Idoso , Anisotropia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatísticas não Paramétricas
8.
Magn Reson Imaging ; 28(3): 388-93, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20071117

RESUMO

Blood oxygenation level dependent (BOLD) response related to interictal activity was evaluated in a patient with post-traumatic focal epilepsy at repeated continuous electroencephalogram (EEG)-functional magnetic resonance imaging examinations. Lateralized interictal EEG activity induced a main cluster of activation co-localized with the anatomical lesion. Spreading of EEG interictal activity to both frontal lobes evoked bilateral clusters of activation indicating that topography of BOLD response might depend on the spatial distribution of epileptiform activity.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiopatologia , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Masculino
9.
J Appl Clin Med Phys ; 11(1): 2927, 2009 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-20160677

RESUMO

The rotational variance dependence of diffusion tensor imaging (DTI) derived parameters on the number of diffusion weighting directions (N) has been investigated by several Monte Carlo simulation studies. However, the dependence of fractional anisotropy (FA) and mean diffusivity (MD) maps on N, in terms of accuracy and contrast between different anatomical structures, has not been assessed in detail. This experimental study further investigated in vivo the effect of the number of diffusion weighting directions on DTI maps of FA and MD. Human brain FA and MD maps of six healthy subjects were acquired at 1.5T with varying N (6, 11, 19, 27, 55). Then, FA and MD mean values in high (FAH, MDH) and low (FAL, MDL) anisotropy segmented brain regions were measured. Moreover, the contrast-to-signal variance ratio (CVRFA, CVRMD) between the main white matter and the surrounding regions was calculated. Analysis of variance showed that FAL, FAH and CVRFA significantly (p < 0.05) depend on N. In particular, FAL decreased (6%-11%) with N, whereas FAH (1.6%-2.5%) and CVRFA (4%-6.5%) increased with N. MDL, MDH and CVRMD did not significantly (p>0.05) depend on N. Unlike MD values, FA values significantly vary with N. It is noteworthy that the observed variation is opposite in low and high anisotropic regions. In clinical studies, the effect of N may represent a confounding variable for anisotropy measurements and the employment of DTI acquisition schemes with high N (> 20) allows an increased CVR and a better visualization of white matter structures in FA maps.


Assuntos
Mapeamento Encefálico , Encéfalo/anatomia & histologia , Imagem de Tensor de Difusão , Algoritmos , Anisotropia , Difusão , Humanos , Imagens de Fantasmas , Rotação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...