Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(26): 261801, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450797

RESUMO

We conduct the first "light-shining-through-wall" (LSW) search for dark photons using two state-of-the-art high-quality-factor superconducting radio frequency (SRF) cavities -Dark SRF-and report the results of its pathfinder run. Our new experimental setup enables improvements in sensitivity over previous searches and covers new dark photon parameter space. We design delicate calibration and measurement protocols to utilize the high-Q setup at Dark SRF. Using cavities operating at 1.3 GHz, we establish a new exclusion limit for kinetic mixing as small as ε=1.6×10^{-9} and provide the world's best constraints on dark photons in the 2.1×10^{-7}-5.7×10^{-6} eV mass range. Our result is the first proof of concept for the enabling role of SRF cavities in LSW setups, with ample opportunities for further improvements. In addition, our data set a competitive lab-based limit on the standard model photon mass by searching for longitudinal photon polarization.


Assuntos
Fótons , Cinética
2.
Sci Rep ; 11(1): 4477, 2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33627743

RESUMO

High brightness, high charge electron beams are critical for a number of advanced accelerator applications. The initial emittance of the electron beam, which is determined by the mean transverse energy (MTE) and laser spot size, is one of the most important parameters determining the beam quality. The bialkali photocathodes illuminated by a visible laser have the advantages of high quantum efficiency (QE) and low MTE. Furthermore, Superconducting Radio Frequency (SRF) guns can operate in the continuous wave (CW) mode at high accelerating gradients, e.g. with significant reduction of the laser spot size at the photocathode. Combining the bialkali photocathode with the SRF gun enables generation of high charge, high brightness, and possibly high average current electron beams. However, integrating the high QE semiconductor photocathode into the SRF guns has been challenging. In this article, we report on the development of bialkali photocathodes for successful operation in the SRF gun with months-long lifetime while delivering CW beams with nano-coulomb charge per bunch. This achievement opens a new era for high charge, high brightness CW electron beams.

3.
Phys Rev Lett ; 124(24): 244801, 2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32639812

RESUMO

Continuous-wave photoinjectors operating at high accelerating gradients promise to revolutionize many areas of science and applications. They can establish the basis for a new generation of monochromatic x-ray free electron lasers, high-brightness hadron beams, or a new generation of microchip production. In this Letter we report on the record-performing superconducting rf electron gun with CsK_{2}Sb photocathode. The gun is generating high charge electron bunches (up to 10 nC/bunch) and low transverse emittances, while operating for months with a single photocathode. This achievement opens a new era in generating high-power beams with a very high average brightness.

4.
Phys Rev Lett ; 124(8): 084801, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-32167359

RESUMO

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

5.
Rev Sci Instrum ; 84(11): 113304, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24289393

RESUMO

We propose a theoretical model based on network analysis to study the external quality factor (Q factor) of dual-feed coupling for superconducting radio-frequency (SRF) cavities. Specifically, we apply our model to the dual-feed 704 MHz half-cell SRF gun for Brookhaven National Laboratory's prototype Energy Recovery Linac (ERL). The calculations show that the external Q factor of this dual-feed system is adjustable from 10(4) to 10(9) provided that the adjustment range of a phase shifter covers 0°-360°. With a period of 360°, the external Q factor of the coupling system changes periodically with the phase difference between the two coupling arms. When the RF phase of both coupling arms is adjusted simultaneously in the same direction, the external Q factor of the system also changes periodically, but with a period of 180°.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...