Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Am J Vet Res ; 83(5): 412-418, 2022 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-35239505

RESUMO

OBJECTIVE: The objectives of this study were to investigate scattered radiation doses to the hands of equine workers holding the cassette and the x-ray tube by hand, for both limb and vertebral column studies, and to compare the scattered radiation attenuation of lead with radiation protection lead-free gloves. Radiation doses to the hands of the cassette holder in the primary beam were also investigated. SAMPLE: A whole-body horse cadaver. PROCEDURES: A portable x-ray unit was used to simulate 6 radiographic study types in the horse cadaver. Doses were measured with no shielding and, for cassette holders, with the ion chamber enclosed in a lead glove and a lead-free glove. Thirty exposures were performed for each study view and condition (n = 1,920). RESULTS: Mean scattered doses to x-ray unit operators were higher than doses to cassette holders for ungula (hoof), thoracic vertebrae, and lumbar vertebrae studies, whereas doses to cassette holders were higher than doses to x-ray tube operators for studies of the metacarpophalangeal joint (fetlock) and tarsus (hock). Doses did not differ for the stifle joint. Mean percentage decrease in scattered radiation dose was 99.58% with lead gloves and 98.9% with lead-free gloves. CLINICAL RELEVANCE: X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders. Lead-free hand shielding should only be considered as an alternative to lead gloves if their lighter weight increases frequency of use by workers.


Assuntos
Doenças dos Cavalos , Exposição Ocupacional , Animais , Cadáver , Cavalos , Exposição Ocupacional/análise , Doses de Radiação , Coluna Vertebral/diagnóstico por imagem , Raios X
2.
Can J Vet Res ; 86(1): 27-34, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34975219

RESUMO

Computed tomographic (CT) features of lymph nodes are used for diagnosis, staging, and response evaluation in veterinary patients. The objectives of this study were to describe maximum short- and long-axis transverse diameters (SATD and LATD, respectively), volume, and attenuation of presumed normal canine mandibular lymph nodes (MLNs) and medial retropharyngeal lymph nodes (MRLNs), to investigate the effect of variables on these features, and to describe inter-observer reliability of transverse diameter and attenuation measurement. Computed tomography studies of 161 dogs were retrospectively reviewed. Median values for SATD were 5.2 and 5.4 mm, median values for volume were 0.26 and 0.54 cm3, and median values for attenuation were 32.3 and 31.8 Hounsfield units (HU) for MLN and MRLN, respectively. Median LATD was 11 mm for MLNs. Height of the first cervical vertebra (HCV1) and weight were positively associated with transverse diameters of both MLNs and MRLNs (P < 0.001). Grade of dental disease was negatively associated with transverse diameters of both MLNs (P = 0.001) and MRLNs (P < 0.03). The intraclass correlation coefficient (ICC) was 0.94 [95% confidence interval (CI): 0.94 to 0.95] for transverse diameter measurement. This study provides descriptive data on the CT characteristics of presumed normal MLNs and MRLNs in dogs and describes a highly reliable method of measuring transverse diameter.


Les caractéristiques tomodensitométriques (CT) des ganglions lymphatiques sont utilisées pour le diagnostic, la stadification et l'évaluation de la réponse chez les patients vétérinaires. Les objectifs de cette étude étaient de décrire les diamètres transversaux maximaux à axe court et long (SATD et LATD, respectivement), le volume et l'atténuation des ganglions lymphatiques mandibulaires canins (MLN) et des ganglions lymphatiques rétropharyngés médians (MRLN) présumés normaux, afin d'étudier l'effet de variables sur ces caractéristiques, et pour décrire la fiabilité inter-observateur de la mesure du diamètre transversal et de l'atténuation. Des études de tomodensitométrie de 161 chiens ont été examinées rétrospectivement. Les valeurs médianes pour la SATD étaient de 5,2 et 5,4 mm, les valeurs médianes pour le volume étaient de 0,26 et 0,54 cm3, et les valeurs médianes pour l'atténuation étaient de 32,3 et 31,8 unités Hounsfield (HU) pour MLN et MRLN, respectivement. Le LATD médian était de 11 mm pour les MLN. La hauteur de la première vertèbre cervicale (VHC1) et le poids étaient positivement associés aux diamètres transversaux des MLN et des MRLN (P < 0,001). Le grade de maladie dentaire était négativement associé aux diamètres transversaux des MLN (P = 0,001) et des MRLN (P < 0,03). Le coefficient de corrélation intraclasse (ICC) était de 0,94 [intervalle de confiance (IC) à 95 % : 0,94 à 0,95] pour la mesure du diamètre transversal. Cette étude fournit des données descriptives sur les caractéristiques CT des MLN et MRLN présumés normaux chez le chien et décrit une méthode très fiable de mesure du diamètre transversal.(Traduit par Docteur Serge Messier).


Assuntos
Linfonodos , Tomografia Computadorizada por Raios X , Animais , Cães , Linfonodos/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/veterinária
3.
Vet Radiol Ultrasound ; 63(1): 23-29, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34637582

RESUMO

Veterinary workers use lead shielding for protection against harm from ionizing radiation during diagnostic imaging. Surface lead on shielding has been reported as a potential exposure hazard. The purpose of this prospective, analytical, descriptive study was to measure surface lead on lead-containing shielding in the field service and small animal radiology areas of a veterinary teaching hospital, and to examine potential risk factors for surface lead. Surface lead on a convenience sample of 54 lead shielding items was measured in a commercial laboratory using inductively coupled plasma mass spectrometry. The median and range of surface lead for aprons, thyroid collars, and gloves were 3.6 µg/dm2 (range, 1.3-22.4 µg/dm2 ), 23.1 µg/dm2 (range, 2.6-116 µg/dm2 ), and 134 µg/dm2 (range, 1.5-155 µg/dm2 ), respectively. In the final multivariable analysis, the mean surface lead on thyroid collars and gloves was higher than on aprons (relative differences 4.8, 95% confidence interval [CI] 2.2, 10.5, P < 0.001; and 9.5, 95% CI 4.4, 20.6, P < 0.001, respectively). The mean surface lead on shielding in the worst condition was higher than on shielding in the intermediate and best conditions (P < 0.001). Lead shielding provides effective protection against the harmful effects of ionizing radiation, and shielding should always be worn during radiation exposure. Based on our findings and the common use of lead shielding in veterinary workplaces, we recommend that employers inform workers of this hazard and provide training on steps to mitigate exposure, including the use of disposable gloves when wearing lead shielding and handwashing after use.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Animais , Hospitais Veterinários , Hospitais de Ensino , Chumbo , Equipamento de Proteção Individual , Estudos Prospectivos , Doses de Radiação
4.
J Am Vet Med Assoc ; 259(S1): 1-4, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34910668

RESUMO

In collaboration with the American College of Veterinary Radiology.


Assuntos
Radiologia , Animais , Humanos , Radiografia , Estados Unidos
5.
J Am Vet Med Assoc ; 259(8): 919-926, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34609178

RESUMO

OBJECTIVES: To describe self-reported radiation safety practices by equine veterinary technicians in North America and identify factors associated with these practices. SAMPLE: 154 equine technicians. PROCEDURES: An electronic questionnaire regarding radiation safety practices during the use of portable x-ray equipment was sent to 884 members of the American Association of Equine Veterinary Technicians and Assistants. Data were summarized, and various factors were evaluated for associations with reported safety practices. RESULTS: 221 of 884 (25.0%) questionnaires were completed, including 154 by equine technicians who had been involved in equine radiography as x-ray tube operators, cassette holders, or both in the previous year. Lead apron use was suboptimal, reported as "always" for 80.0% (104/130) of tube operators and 83.1% (123/148) of cassette holders. Approximately 20% of participants never wore thyroid shields, and approximately 90% never wore lead eyeglasses. Almost 50% of participants did not have lead eyeglasses available. Although > 55% of participants always held the x-ray equipment by hand, 58.4% (73/125) of tube operators and 25.0% (35/140) of cassette holders never wore gloves. Cassette holders wore lead gloves and personal radiation dose-monitoring devices significantly more frequently than did tube operators. CONCLUSIONS AND CLINICAL RELEVANCE: Compliance of North American equine technicians with radiation safety recommendations by the National Council on Radiation Protection and Measurements was suboptimal. Improvements in radiation safety training and education, strengthening the connection between academic institutions and private practices, and greater availability and requirement of personal protective equipment use by senior clinicians and employers might aid in improving safety practices.


Assuntos
Técnicos em Manejo de Animais , Exposição Ocupacional , Animais , Cavalos , Humanos , Doses de Radiação , Radiografia , Autorrelato , Inquéritos e Questionários , Raios X
6.
J Am Vet Med Assoc ; 259(5): 518-527, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34388017

RESUMO

OBJECTIVE: To describe the radiation safety behaviors of veterinary specialists performing small animal fluoroscopic procedures and examine potential risk factors for these behaviors, including knowledge of radiation risk and training regarding machine operating parameters. SAMPLE: 197 veterinary specialists and residents in training. PROCEDURES: An electronic questionnaire was distributed to members of the American Colleges of Veterinary Internal Medicine (subspecialties of cardiology and small animal internal medicine), Veterinary Radiology, and Veterinary Surgery. RESULTS: The overall survey response rate was 6% (240/4,274 email recipients). Of the 240 respondents, 197 (82%) had operated an x-ray unit for a small animal fluoroscopic procedure in the preceding year and fully completed the questionnaire. More than 95% of respondents believed that radiation causes cancer, yet approximately 60% of respondents never wore hand or eye protection during fluoroscopic procedures, and 28% never adjusted the fluoroscopy machine operating parameters for the purpose of reducing their radiation dose. The most common reasons for not wearing eye shielding included no requirement to wear eyeglasses, poor fit, discomfort, and interference of eyeglasses with task performance. Respondents who had received training regarding machine operating parameters adjusted those parameters to reduce their radiation dose during procedures significantly more frequently than did respondents who had not received training. CONCLUSIONS AND CLINICAL RELEVANCE: On the basis of the self-reported suboptimal radiation safety practices among veterinary fluoroscopy users, we recommend formal incorporation of radiation safety education into residency training programs. All fluoroscopy machine operators should be trained regarding the machine operating parameters that can be adjusted to reduce occupational radiation exposure.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Animais , Fluoroscopia/veterinária , Doses de Radiação , Autorrelato , Especialização
7.
Can Vet J ; 62(4): 349-356, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33867546

RESUMO

The objective of this study was to report observed radiation safety practices among equine workers using portable X-ray units at 3 veterinary practices in Canada. Practice 1 was comprised of equine field service workers from an academic institution, whereas Practices 2 and 3 were comprised of workers from private equine referral practices. Out of 2969 exposure-worker observations, protective aprons were worn for > 99% (2968/2969), thyroid shields for 87% (2584/2969), and eyeglasses for 10% (310/2969). The cassette was held by hand for 97% (1078/1114) of observations, and the X-ray unit was held by hand for 100% (1293/1293) of observations. Gloves were used for 54% (606/1114) and < 1% (5/1293) of observations involving cassette holders and X-ray tube operators, respectively. Use of gloves was more frequent among technologists than DVMs (P = 0.004), and among workers in Practices 1 and 3 than in Practice 2 (P < 0.001). In conclusion, given that workers commonly hold cassettes and X-ray tubes by hand, improvement in shielding use is needed. Consideration should be given to specific behavior recommendations in radiation regulations.


Pratiques de radioprotection chez les travailleurs vétérinaires équins canadiens pendant les procédures de diagnostic avec un équipement de radiographie portable. L'objectif de la présente étude était de rapporter les pratiques de radioprotection observées chez les travailleurs équins utilisant des appareils de radiographie portatifs dans trois pratiques vétérinaires au Canada. La pratique 1 était composée de travailleurs équins sur le terrain d'une institution universitaire, tandis que les pratiques 2 et 3 étaient composées de travailleurs sur le terrain issus de pratiques de référence équines privées. Sur 2969 observations de travailleurs exposés, des tabliers de protection ont été portés pour > 99 % (2968/2969), des écrans thyroïdiens pour 87 % (2584/2969) et des lunettes pour 10 % (310/2969). La cassette a été tenue à la main pour 97 % (1078/1114) des observations et l'unité de radiographie a été tenue à la main pour 100 % (1293/1293) des observations. Des gants ont été utilisés pour 54 % (606/1114) et < 1 % (5/1293) des observations impliquant des porteurs de cassette et des opérateurs de tubes à rayons X, respectivement. L'utilisation de gants était plus fréquente chez les technologues que chez les vétérinaires (P = 0,004) et chez les travailleurs des Pratiques 1 et 3 que ceux de la Pratique 2 (P < 0,001). En conclusion, étant donné que les travailleurs tiennent généralement des cassettes et des tubes à rayons X à la main, une amélioration de l'utilisation du blindage est nécessaire. Il faudrait tenir compte des recommandations de comportement spécifiques dans les réglementations relatives aux rayonnements.(Traduit par Dr Serge Messier).


Assuntos
Exposição Ocupacional , Animais , Canadá , Fluoroscopia , Cavalos , Radiografia , Raios X
8.
J Vet Intern Med ; 33(3): 1403-1413, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30883935

RESUMO

BACKGROUND: The clinical applicability of sonography and sonoelastography (SOE) in the detection of lymph node malignancy in dogs has not been established. OBJECTIVES: To compare sonographic and sonoelastographic findings between malignant and benign superficial lymph nodes and to evaluate the diagnostic performance of those methods. ANIMALS: One-hundred sixteen lymph nodes of 54 dogs. METHODS: A prospective observational study was used to investigate sonographic features and elasticity scores of malignant and benign superficial lymph nodes. Lymph nodes were categorized as malignant or benign according to cytology or histopathology. Quantitative variables were compared using Student's unpaired t test. Prevalence of categorical variables was compared using nonparametric Mann-Whitney U test. Diagnostic performance was calculated by receiver-operating characteristic analysis. RESULTS: Forty-nine malignant and 67 benign lymph nodes were included. Malignant nodes had larger long axis (LA; P = .0002), short axis (SA; P < .0001) and short-to-long axis ratio (P < .0001) in comparison with benign nodes. Malignant nodes had a higher prevalence of mixed vascular distribution on Doppler color flow mapping (P < .005) and on power Doppler (P < .0001) and higher resistivity index (RI; P < .0001), pulsatility index (P < .0001), and elasticity score (P < .0001) in comparison with benign nodes. Short axis, elasticity score, and RI offered the best accuracies, 80.2%, 78.1%, and 77.7% (P < .05), respectively, for malignancy detection. CONCLUSIONS AND CLINICAL IMPORTANCE: Results support the use of Doppler sonography and SOE as auxiliary methods to brightness mode sonography to detect nodal malignancy.


Assuntos
Doenças do Cão/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/veterinária , Linfonodos/diagnóstico por imagem , Linfoma/veterinária , Ultrassonografia/veterinária , Animais , Diagnóstico Diferencial , Cães , Metástase Linfática/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Estudos Prospectivos
9.
Vet Radiol Ultrasound ; 59(2): 137-146, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29230889

RESUMO

The use of personal protective equipment by veterinary workers during radiographic imaging is inconsistent. While the self-reported use of leaded aprons and thyroid shields approaches 100% in some studies, the use of leaded gloves and eyeglasses is much lower. Previous studies describing personal protective equipment use are based on self-reporting. Objectives of this prospective, observational study were to describe use of leaded personal protective equipment during radiographic imaging by veterinary workers, and to compare observed use with self-reported use. Use of leaded personal protective equipment during radiographic imaging by veterinary workers was observed over a 10 week period using two motion-triggered video cameras, and a questionnaire was then completed by workers on their use of personal protective equipment. Workers restrained the animal during 91.8% (753/820) of exposures. An apron and a securely closed thyroid shield were worn for >99% of studies. Gloves were used correctly for 43.6% (156/358) of radiographic studies. Leaded eyeglasses were worn for 1.7% (6/358) of studies. Correct glove use was more frequent during regular working hours than after-hours for both veterinarians (odds ratio 32.7, P = 0.001) and veterinary students (odds ratio 75.1, P < 0.001). The number of workers in the room was lower when animals were sedated (P = 0.002) or anesthetized (P = 0.017). Workers overestimated their frequency of glove use (P <0.001). In conclusion, workers use personal protective equipment less frequently in an unsupervised environment, and overestimate their use of personal protective equipment. Use of sedation or anesthesia decreases worker exposure to ionizing radiation.


Assuntos
Hospitais Veterinários/estatística & dados numéricos , Hospitais de Ensino/estatística & dados numéricos , Equipamento de Proteção Individual/veterinária , Proteção Radiológica/estatística & dados numéricos , Radiografia/veterinária , Animais , Exposição Ocupacional/prevenção & controle , Equipamento de Proteção Individual/estatística & dados numéricos , Estudos Prospectivos , Exposição à Radiação/prevenção & controle
10.
Pesqui. vet. bras ; 37(10): 1172-1176, out. 2017. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-895347

RESUMO

Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes), according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05). Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01). Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.(AU)


A ultrassonografia com Doppler pulsado foi utilizado para avaliar o fluxo sanguíneo portal, velocidade portal e índice de congestão portal em 24 ovinos saudáveis divididos em grupos (cordeiros, borregos e ovelhas), de acordo com a idade. As medições foram realizadas no 11o espaço intercostal direito utilizando ângulo de insonação ideal e método de inclusão uniforme. Os valores médios obtidos em cada grupo foram comparados com ANOVA, seguido pelo teste post-hoc de Tukey. A velocidade portal e o fluxo de sangue portal foram estatisticamente semelhantes entre os grupos (P>0,05). A velocidade portal média foram 17,75; 17,13 e 16,75; enquanto o fluxo de sangue portal médios foram 26,65; 31,04 e 24,32 para cordeiros, borregos e ovelhas, respectivamente. O índice de congestão portal foi estatisticamente diferente entre os grupos e os valores para cordeiros, novilhos e ovelhas foram 0,009; 0,058 e 0,09, respectivamente (P<0.01). Observaram-se diferenças estatísticas nos diâmetros da veia porta, na área da veia porta e nos índices de congestão portal entre os grupos, provavelmente devido à influência do peso e não pela idade.(AU)


Assuntos
Animais , Ovinos/fisiologia , Pressão na Veia Porta/fisiologia , Ultrassonografia Doppler de Pulso/veterinária , Circulação Hepática/fisiologia , Fígado/lesões
11.
Pesqui. vet. bras ; 36(6): 545-550, jun. 2016. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: lil-792609

RESUMO

There is no standardization in the literature of kidney length in sheep at different ages, as there are few studies about the access with the Doppler triplex ultrasound for the renal vascularization in this species. Eighty healthy sheep of three age groups of Ile de France and White Dorper breed were used: 20 lambs, 30 yearlings and 30 adults (8 rams and 22 ewes). Renal healthiness of the animals was confirmed by serum biochemical tests of urea and creatinine, and by observation of renal architecture with conventional ultrasound, besides measurement of vital parameters. A portable ultrasound (My LabTM30 Vet Gold Esaote®, Esaote Healthcare) device was used, with a convex transducer with 3.5MHz frequency. After identification of the kidneys in two-dimensional mode, the measurement of length in the sagittal section was performed in all sheep (n=80). Then color Doppler was activated for visualization of renal and interlobar arteries of the right kidney, and the resistivity index (RI) of the yearlings (n=30) and ewes (n=22) was measured. Biochemical tests remained within normal limits and renal architecture was preserved. The values ​​of the right and left renal length were different between the groups, increasing with age (4.34cm and 4.31cm in lambs; 6.08cm and 6.23cm in yearlings; 7.57cm and 7.37cm in adults, respectively). Median values of RI of the renal artery were statistically different (p<0.05) between the groups of yearlings (0.57) and ewes (0.52). The median RI of the interlobar artery was similar in yearlings (0.58) and ewes (0.54).(AU)


Não há na literatura padronização do comprimento renal de ovinos, em diferentes idades, assim como existem poucos trabalhos sobre a vascularização renal nesta espécie. Utilizaram-se no total 80 ovinos hígidos de três faixas etárias, das raças Ile de France e White Dorper: 20 cordeiros, 30 borregos e 30 adultos (8 carneiros e 22 ovelhas). A higidez renal dos animais foi comprovada por exames bioquímicos séricos de ureia e creatinina e pela observação da arquitetura renal. Utilizou-se aparelho de Ultrassom portátil (My LabTM30 Vet Gold Esaote®, Esaote Healthcare), com transdutor convexo de frequência de 3,5MHz. Após identificação dos rins no modo bidimensional, foi realizada a mensuração do comprimento no corte sagital em todos os ovinos. Em seguida, Doppler colorido foi ativado para visualização das artérias renal e interlobar do rim direito, e mensurou-se o índice de resistividade dos borregos (n=30) e ovelhas (n=22). Os exames bioquímicos permaneceram dentro da normalidade e a arquitetura renal estava preservada. Os valores do comprimento renal direito e esquerdo foram diferentes entre os grupos, sendo crescente conforme a idade (4,34 e 4,31 em cordeiros, 6,08 e 6,23 em borregos, 7,57 e 7,37 em adultos). As medianas do IR da artéria renal foi estatisticamente diferente (p<0,05) entre os grupos dos borregos (0,57) e ovelhas (0,52). A mediana do IR da artéria interlobar não apresentou diferença entre borregos (0,58) e ovelhas (0,54).(AU)


Assuntos
Animais , Creatinina/sangue , Rim/anatomia & histologia , Rim/irrigação sanguínea , Ovinos/anatomia & histologia , Ureia/sangue , Ultrassonografia Doppler em Cores/veterinária
12.
Pesqui. vet. bras ; 34(supl.1): 99-106, dez. 2014. tab, ilus
Artigo em Português | LILACS, VETINDEX | ID: lil-778345

RESUMO

A incidência da urolitíase obstrutiva em ovinos é elevada, principalmente em machos confinados, tanto para produção de carne, quanto reprodutores de alto valor genético. A acidificação urinária é um dos métodos para prevenção desta enfermidade e pode ser realizada de forma eficaz com a suplementação de cloreto de amônio (CA) na dieta. Utilizaram-se 100 ovinos, machos não castrados, mestiços (Ile de France X White Dorper), confinados, com idade aproximada de três meses. Constituíram-se três grupos experimentais: Grupo 21CA (n=40) que recebeu 400mg/kg/PV de cloreto de amônio/animal/dia, por 21 dias consecutivos; Grupo 42CA (n=40) que foi suplementado com 400mg/kg/PV de cloreto de amônio/animal/dia, por 42 dias consecutivos; Grupo controle (n=20), que não recebeu CA. A alimentação consistiu de ração total, composta por 15% de feno triturado e 85% de concentrado, água e sal mineral ad libitum. Após 14 dias de adaptação à alimentação e ao ambiente, os Momentos (M) de avaliação clínica, colheita de sangue e exame ultrassonográfico foram realizados com intervalo de sete dias, sendo M0 (imediatamente antes do início do tratamento com cloreto de amônio), M1 (sete dias após), M2 (14 dias após), M3 (21 dias após o início do tratamento e suspensão do cloreto de amônio em Grupo 21CA), M4 (28 dias após), M5 (35 dias após) e M6 (42 dias após), totalizando 56 dias de confinamento. As dosagens de ureia e creatinina não evidenciaram alteração na função renal, embora a ureia estivesse acima dos valores de referência para espécie ovina. Observaram-se imagens ultrassonográficas compatíveis com cálculos vesicais e dilatação de pelve renal. No Grupo 21CA, 15% (6/40) dos animais apresentaram cálculos vesicais; no Grupo 42CA, 5% (2/40); e no Grupo controle, 20% (4/20) dos cordeiros. Visibilizaram-se também imagens sugestivas de sedimentos e cristais em 31% (31/100) dos animais examinados. A ultrassonografia permitiu a visibilização de alterações renais e vesicais, porém não relacionados ao quadro clínico de urolitíase obstrutiva, revelando-se como um exame complementar de grande relevância para o diagnóstico precoce de alterações no sistema urinário de ovinos.(AU)


The incidence of obstructive urolithiasis in sheep is high, especially in feedlot males, both for meat production, or the breeder of high genetic value. The urinary acidification is one of the methods for preventing this disease and can be performed efficiently with supplementation of ammonium chloride (AC) in the diet. It was used 100 male lambs, in a feedlot, crossbred (Ile de France X White Dorper), aged approximately three months. It was constituted three groups: Group 21AC (n=40) that received 400mg/kg/PV of ammonium chloride/animal/day for 21 consecutive days, the time of discontinuation of the urinary acidifiers (M3) and continued clinical follow until the end of the experiment (M6); Group 42AC (n=40), that received 400mg/kg/PV of ammonium chloride/animal/day for 42 consecutive days, Group control (n=20), that did not receive ammonium chloride throughout the experimental period. The feed consisted of total dry matter, composed of 15% ground hay and 85% concentrate, water and mineral salts ad libitum. After 14 days of adaptation to food and the environment, the moments (M) for clinical evaluation, and blood collection ultrasound examinations were performed with an interval of seven days, and M0 (immediately before the beginning of the treatment with ammonium chloride), M1 (seven days), M2 (14 days after), M3 (21 days after initiation of treatment and suspension of ammonium chloride in Group 21CA), M4 (28 days), M5 (35 days), and M6 (42 days), amounting to 56 days of feedlot. The serum urea and creatinine showed no change in renal function, although the urea was above the reference values for sheep. There were compatible ultrasound images with bladder stones and dilatation of the renal pelvis. In Group 21AC, 15% (6/40) of the animals had bladder stones; in Group 42AC 5% (2/40); and in Group control, 20% (4/20) of the lambs. It was visualized suggestive images of sediment and crystals in 31% (31/100) of examined animals. Ultrasonography allowed visualization of kidney and bladder abnormalities, which were not related to clinical symptoms of obstructive urolithiasis, appearing as an examination complement of great importance for the early detection of changes in the urinary system of sheep.(AU)


Assuntos
Animais , Ovinos , Vesícula/diagnóstico por imagem , Cloreto de Amônio/administração & dosagem , Rim/diagnóstico por imagem , Dieta/veterinária
13.
Pesqui. vet. bras ; 31(10): 839-843, out. 2011. tab
Artigo em Português | LILACS | ID: lil-606657

RESUMO

O presente estudo investigou o uso da cito-(73,0 por cento), Arcanobacterium pyogenes (6,0 por cento), Streptococlogia aspirativa com agulha fina no diagnóstico da lin-cus spp. β hemolítico (5,0 por cento) e Escherichia coli (4,0 por cento) fadenite em ovinos e a ocorrência de microrganismos foram os microrganismos mais frequentes nos animais nos linfonodos com lesões, com ênfase no isolamento de com linfadenite. Streptococcus spp. (21,0 por cento) e Staphylo-Corynebacterium pseudotuberculosis. Foram utilizados coccus spp. (7,0 por cento) foram as bactérias isoladas com 100 linfonodos de ovinos com aumento de volume su-maior frequência nos linfonodos sem lesões colhidos em gestivos de linfadenite e 100 linfonodos de ovinos sem abatedouro. A punção aspirativa com agulha fina perlesões, colhidos em abatedouro. C. pseudotuberculosis mitiu identificar microrganismos "corineformes" em 79 (79,0 por cento) animais com linfadenite e, destes, 73 (73,0 por cento) foram identificados como C. pseudotuberculosis. Nenhuma linhagem de C. pseudotuberculosis foi isolada dos linfonodos dos animais sem lesões. Concluiu-se que C. pseudotuberculosis foi o microrganismo mais freqüente nos ovinos com linfadenite, e que a citologia aspirativa pode ser utilizada como método de triagem no diagnóstico da linfadenite caseosa ovina.


The fine needle aspiration in diagnosis of lymphadenitis in sheep, and occurrence of microorganisms in the lymph nodes, with emphasis to identification of Corynebacterium pseudotuberculosis were investigated. One hundred sheep with lymphadenitis and 100 lymph nodes without lesions collected from sheep in slaughterhouses were evaluated. C. pseudotuberculosis (73.0 percent), Arcanobacterium pyogenes (6.0 percent), Streptococcus spp. β hemolytic (5.0) and Escherichia coli (4.0 percent) were the more frequent causal agents in sheep with lymphadenitis. Streptococcus spp. (21.0 percent) and Staphylococcus spp. (7.0 percent) were the more common microorganisms identified in lymph nodes without lesions sampled in slaughterhouse. Fine needle aspiration enable identify 79 (79.0 percent) microorganisms with "corynebacteria" aspect in sheep with lymphadenitis. From these, 73 (73.0 percent) were identified as C. pseudotuberculosis. None strain of C. pseudotuberculosis was isolated from lymph nodes of animals without lesions. The results showed the high frequency of C. pseudotuberculosis in sheep with lymphadenitis, and possibility the use of fine needle aspiration in initial diagnosis of lymphadenitis in sheep.


Assuntos
Animais , Corynebacterium pseudotuberculosis/citologia , Linfadenite/veterinária , Ovinos/lesões , Biópsia por Agulha/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...