Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38542337

RESUMO

Chronic myeloid leukemia (CML) is a type of leukemia whose main genetic marker is the reciprocal translocation that leads to the production of the BCR::ABL1 oncoprotein. The expression of some genes may interfere with the progression and development of leukemias. MicroRNAs are small non-coding RNAs that have the potential to alter the expression of some genes and may be correlated with some types of leukemia and could be used as biomarkers in the diagnosis and prognosis of patients. Therefore, this project carried out an analysis of microRNA-type plasma biomarkers in patients with chronic myeloid leukemia at unique points, including follow-up analysis of patients from the Erasto Gaertner Hospital. 35 microRNAs were analyzed in different cohorts. Inside those groups, 70 samples were analyzed at unique points and 11 patients in a follow-up analysis. Statistically different results were found for microRNA-7-5p, which was found to be upregulated in patients with high expression of the BCR::ABL1 transcript when compared to healthy controls. This microRNA also had evidence of behavior related to BCR::ABL1 when analyzed in follow-up, but strong evidence was not found. In this way, this work obtained results that may lead to manifestations of a relationship between miR-7-5p and chronic myeloid leukemia, and evaluations of possible microRNAs that are not related to this pathology.


Assuntos
Leucemia Mielogênica Crônica BCR-ABL Positiva , MicroRNAs , Humanos , MicroRNAs/genética , Proteínas de Fusão bcr-abl/genética , Proteínas de Fusão bcr-abl/metabolismo , Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Leucemia Mielogênica Crônica BCR-ABL Positiva/patologia , Translocação Genética , Biomarcadores
2.
J Neurovirol ; 29(3): 308-324, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37219809

RESUMO

CD14++CD16+ monocytes are susceptible to HIV-1 infection, and cross the blood-brain barrier. HIV-1 subtype C (HIV-1C) shows reduced Tat protein chemoattractant activity compared to HIV-1B, which might influence monocyte trafficking into the CNS. We hypothesized that the proportion of monocytes in CSF in HIV-1C is lower than HIV-1B group. We sought to assess differences in monocyte proportions in cerebrospinal fluid (CSF) and peripheral blood (PB) between people with HIV (PWH) and without HIV (PWoH), and by HIV-1B and -C subtypes. Immunophenotyping was performed by flow cytometry, monocytes were analyzed within CD45 + and CD64 + gated regions and classified in classical (CD14++CD16-), intermediate (CD14++CD16+), and non-classical (CD14lowCD16+). Among PWH, the median [IQR] CD4 nadir was 219 [32-531] cell/mm3; plasma HIV RNA (log10) was 1.60 [1.60-3.21], and 68% were on antiretroviral therapy (ART). Participants with HIV-1C and -B were comparable in terms of age, duration of infection, CD4 nadir, plasma HIV RNA, and ART. The proportion of CSF CD14++CD16+ monocytes was higher in participants with HIV-1C than those with HIV-1B [2.00(0.00-2.80) vs. 0.00(0.00-0.60) respectively, p = 0.03 after BH correction p = 0.10]. Despite viral suppression, the proportion of total monocytes in PB increased in PWH, due to the increase in CD14++CD16+ and CD14lowCD16+ monocytes. The HIV-1C Tat substitution (C30S31) did not interfere with the migration of CD14++CD16+ monocytes to the CNS. This is the first study to evaluate these monocytes in the CSF and PB and compare their proportions according to HIV subtype.


Assuntos
Infecções por HIV , HIV-1 , Humanos , Monócitos/metabolismo , HIV-1/metabolismo , Receptores de Lipopolissacarídeos/genética , Receptores de IgG/genética , Infecções por HIV/tratamento farmacológico , Infecções por HIV/metabolismo
3.
J Neuroimmunol ; 377: 578067, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36965365

RESUMO

The transactivator of transcription (Tat) is a HIV regulatory protein which promotes viral replication and chemotaxis. HIV-1 shows extensive genetic diversity, HIV-1 subtype C being the most dominant subtype in the world. Our hypothesis is the frequency of CSF CD3+CD56+ and CD3-CD56dim is reduced in HIV-1C compared to HIV-1B due to the Tat C30S31 substitution in HIV-1C. 34 CSF and paired blood samples (PWH, n = 20; PWoH, n = 14) were studied. In PWH, the percentage of CD3+CD56+ was higher in CSF than in blood (p < 0.001), comparable in both compartments in PWoH (p = 0.20). The proportion of CD3-CD56dim in CSF in PWH was higher than PWoH (p = 0.008). There was no subtype differences. These results showed CNS compartmentalization of NKT cell response in PWH.


Assuntos
Infecções por HIV , HIV-1 , Células T Matadoras Naturais , Humanos , HIV-1/metabolismo , Células Matadoras Naturais/metabolismo , Antígeno CD56/metabolismo , Células T Matadoras Naturais/metabolismo , Infecções por HIV/metabolismo , Complexo CD3 , Citometria de Fluxo
4.
J Neurovirol ; 28(2): 291-304, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35190973

RESUMO

HIV-1 subtype C (HIV-1C) shows reduced Tat protein chemoattractant activity compared with HIV-1B. The impact of HIV-1C Tat on the chemotaxis of the main lymphocyte subpopulations in the cerebrospinal fluid (CSF) and the peripheral blood (PB) is unclear. We hypothesized that there would be a lower frequency of specific lymphocyte subpopulations CD3+ or CD19+ in CSF in HIV-1C than in HIV-1B. The objectives were to detect the differences in the proportions of main lymphocyte subpopulations in CSF and PB, between people with HIV (PWH) and HIV-1-uninfected volunteers (PWoH) and in HIV-1B and HIV-1C. Lymphocyte immunophenotyping was studied in CSF and paired PB samples of PWH (n = 22) and PWoH (n = 14). Lymphocytes were analyzed within the CD45+ gated region. The proportions of CSF CD3+CD4+, CD3+CD8+, and CD3-CD19+ lymphocytes in CSF were comparable in HIV-1B and C. There was an increase in the proportion of CD3+CD8+ cells and a decrease in CD3+CD4+ T cells (ps = 0.016) in the CSF samples of the PWH compared with the PWoH group. In the PWH group, both CD3+CD4+ and CD3+CD8+ lymphocytes were significantly higher in the CSF than in the PB (p = 0.047 and 0.005). The proportion of CD3+CD4+ was lower and that of CD3+CD8+ was higher in the CSF samples of the aviremic group than that of HIV-negative control (p = 0.0008 and < 0.0001, respectively). HIV-1C Tat substitution (C30S) did not interfere with the CNS migration of the main lymphocyte subpopulations. This is the first study to evaluate these lymphocytes in CSF and PB of HIV-1C compared with HIV-1B.


Assuntos
Infecções por HIV , HIV-1 , Citometria de Fluxo , Humanos , Imunofenotipagem , Subpopulações de Linfócitos
5.
Rev Bras Hematol Hemoter ; 37(6): 406-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26670404

RESUMO

Minimal residual disease is the most powerful predictor of outcome in acute leukemia and is useful in therapeutic stratification for acute lymphoblastic leukemia protocols. Nowadays, the most reliable methods for studying minimal residual disease in acute lymphoblastic leukemia are multiparametric flow cytometry and polymerase chain reaction. Both provide similar results at a minimal residual disease level of 0.01% of normal cells, that is, detection of one leukemic cell in up to 10,000 normal nucleated cells. Currently, therapeutic protocols establish the minimal residual disease threshold value at the most informative time points according to the appropriate methodology employed. The expertise of the laboratory in a cancer center or a cooperative group could be the most important factor in determining which method should be used. In Brazil, multiparametric flow cytometry laboratories are available in most leukemia treatment centers, but multiparametric flow cytometry processes must be standardized for minimal residual disease investigations in order to offer reliable and reproducible results that ensure quality in the clinical application of the method. The Minimal Residual Disease Working Group of the Brazilian Society of Bone Marrow Transplantation (SBTMO) was created with that aim. This paper presents recommendations for the detection of minimal residual disease in acute lymphoblastic leukemia based on the literature and expertise of the laboratories who participated in this consensus, including pre-analytical and analytical methods. This paper also recommends that both multiparametric flow cytometry and polymerase chain reaction are complementary methods, and so more laboratories with expertise in immunoglobulin/T cell receptor (Ig/TCR) gene assays are necessary in Brazil.

6.
Rev. bras. hematol. hemoter ; 37(6): 406-413, Oct.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-769968

RESUMO

Minimal residual disease is the most powerful predictor of outcome in acute leukemia and is useful in therapeutic stratification for acute lymphoblastic leukemia protocols. Nowadays, the most reliable methods for studying minimal residual disease in acute lymphoblastic leukemia are multiparametric flow cytometry and polymerase chain reaction. Both provide similar results at a minimal residual disease level of 0.01% of normal cells, that is, detection of one leukemic cell in up to 10,000 normal nucleated cells. Currently, therapeutic protocols establish the minimal residual disease threshold value at the most informative time points according to the appropriate methodology employed. The expertise of the laboratory in a cancer center or a cooperative group could be the most important factor in determining which method should be used. In Brazil, multiparametric flow cytometry laboratories are available in most leukemia treatment centers, but multiparametric flow cytometry processes must be standardized for minimal residual disease investigations in order to offer reliable and reproducible results that ensure quality in the clinical application of the method. The Minimal Residual Disease Working Group of the Brazilian Society of Bone Marrow Transplantation (SBTMO) was created with that aim. This paper presents recommendations for the detection of minimal residual disease in acute lymphoblastic leukemia based on the literature and expertise of the laboratories who participated in this consensus, including pre-analytical and analytical methods. This paper also recommends that both multiparametric flow cytometry and polymerase chain reaction are complementary methods, and so more laboratories with expertise in immunoglobulin/T cell receptor (Ig/TCR) gene assays are necessary in Brazil.


Assuntos
Humanos , Citometria de Fluxo , Imunofenotipagem , Neoplasia Residual , Leucemia-Linfoma Linfoblástico de Células Precursoras
7.
J. bras. patol. med. lab ; 50(1): 26-35, 02/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-704695

RESUMO

Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA). Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI), intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples) were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples), based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data...


Introdução: O Sysmex® XE-2100D é um analisador hematológico multiparamétrico destinado à realização de testes hematológicos em sangue anticoagulado com ácido etilenodiamino tetra-acético (EDTA). Objetivos: Considerando a sua importância na prática clínica e laboratorial, o objetivo deste estudo foi avaliar seu desempenho analítico, comparando os resultados obtidos com especificações de qualidade descritas na literatura. Material e método: Na avaliação de desempenho analítico, conforme recomendações do documento H26-A2 do Clinical and Laboratory Standards Institute (CLSI), foram incluídos ensaios de verificação da imprecisão intraensaio ou repetitividade, imprecisão entre ensaios ou reprodutibilidade, linearidade, carryover (arraste), avaliação do mecanismo homogeneizador de amostras, sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos (n = 400 amostras) e a comparação entre a contagem diferencial de leucócitos automatizada e a manual (n = 400 amostras), baseada em uma adaptação do documento H20-A2 do CLSI. Resultados: Os ensaios de verificação da repetitividade, reprodutibilidade, linearidade, carryover (arraste) foram satisfatórios conforme especificações do fabricante. O ensaio de sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos mostrou eficiência, sensibilidade e especificidade de 92,5%; 65,2% e 94,1% respectivamente. Os coeficientes de correlação entre as contagens diferenciais automatizadas e manuais de neutrófilos, linfócitos, monócitos, eosinófilos e basófilos foram de 0,991; 0,99; 0,872; 0,974 e 0,557 respectivamente...


Assuntos
Humanos , Automação Laboratorial/métodos , Automação Laboratorial/normas , Controle de Qualidade , Testes Hematológicos/métodos , Testes Hematológicos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...