IEEE Trans Med Imaging ; 26(3): 283-97, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17354635

RESUMO

A family of alternating minimization algorithms for finding maximum-likelihood estimates of attenuation functions in transmission X-ray tomography is described. The model from which the algorithms are derived includes polyenergetic photon spectra, background events, and nonideal point spread functions. The maximum-likelihood image reconstruction problem is reformulated as a double minimization of the I-divergence. A novel application of the convex decomposition lemma results in an alternating minimization algorithm that monotonically decreases the objective function. Each step of the minimization is in closed form. The family of algorithms includes variations that use ordered subset techniques for increasing the speed of convergence. Simulations demonstrate the ability to correct the cupping artifact due to beam hardening and the ability to reduce streaking artifacts that arise from beam hardening and background events.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia por Raios X/métodos , Funções Verossimilhança , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia por Raios X/instrumentação
2.
Med Phys ; 29(10): 2404-18, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12408315

RESUMO

X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Metais , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Braquiterapia/métodos , Simulação por Computador , Humanos , Modelos Estatísticos , Imagens de Fantasmas , Fótons , Espalhamento de Radiação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA