Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Eur Heart J ; 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222018

RESUMO

BACKGROUND AND AIMS: The optimal antithrombotic therapy in patients with device-detected atrial fibrillation (DDAF) is unknown. Concomitant vascular disease can modify the benefits and risks of anticoagulation. METHODS: These pre-specified analyses of the NOAH-AFNET 6 (n=2534 patients) and ARTESiA (n=4012 patients) trials compared anticoagulation to no anticoagulation in patients with DDAF with or without vascular disease, defined as prior stroke/transient ischemic attack, coronary or peripheral artery disease. Efficacy outcomes were the primary outcomes of both trials, a composite of stroke, systemic arterial embolism (SE), myocardial infarction, pulmonary embolism or cardiovascular death, and stroke or SE. Safety outcomes were major bleeding or major bleeding and death. RESULTS: In patients with vascular disease (NOAH-AFNET 6 56%, ARTESiA 46.0%), stroke, myocardial infarction, systemic or pulmonary embolism, or cardiovascular death occurred at 3.9%/patient-year with and 5.0%/patient-year without anticoagulation (NOAH-AFNET 6), and 3.2%/patient-year with and 4.4%/patient-year without anticoagulation (ARTESiA). Without vascular disease, outcomes were equal with and without anticoagulation (NOAH-AFNET 6 2.7%/patient-year, ARTESiA 2.3%/patient-year in both randomised groups). Meta-analysis found consistent results across both trials (I2heterogeneity=6%) with a trend for interaction with randomised therapy (pinteraction=0.08). Stroke/SE behaved similarly. Anticoagulation increased major bleeding in vascular disease patients (edoxaban 2.1%/patient-year, no anticoagulation 1.3%/patient-year; apixaban 1.7%/patient-year; no anticoagulation 1.1%/patient-year; incidence rate ratio 1.55 [1.10-2.20]) and without vascular disease (edoxaban 2.2%/patient-year; no anticoagulation 0.6%/patient-year; apixaban 1.4%/patient-year; no anticoagulation 1.1%/patient-year, incidence rate ratio 1.93 [0.72-5.20]). CONCLUSIONS: Patients with DDAF and vascular disease are at higher risk of stroke and cardiovascular events and may derive a greater benefit from anticoagulation than patients with DDAF without vascular disease.

2.
Med Clin (Barc) ; 2024 Aug 26.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39191551

RESUMO

INTRODUCTION AND OBJECTIVES: Management in recent-onset atrial fibrillation (AF) is to achieve sinus rhythm (SR) by cardioversion (CV). However, frequently SR is spontaneously restored, making scheduled admission unnecessary and causing misutilization of healthcare resources. Emerging medical technology allows accurate heart rhythm monitoring. This study evaluated this technology in these patients, preventing unnecessary admission and providing an earlier management. METHODS: A multicenter study was designed including patients with AF scheduled for elective electrical CV. Patients submitted ECG recordings to a central CoreLab daily, twice a day and whenever they present symptoms, until CV (spontaneous or scheduled) and a week afterwards. Whenever a spontaneous conversion to SR was detected, investigators were contacted to confirm SR and abort admission. Patients' satisfaction was evaluated using a test for perceived utility, convenience, and accessibility. RESULTS: 74 patients were enrolled (age 62±10 years). Twenty-two patients (30%) showed spontaneous conversion to SR. A total of 22 admissions and 16 transesophageal echocardiograms were prevented. Among 52 patients admitted for CV, 45 (88%) were discharged in SR. During follow-up after conversion to SR (spontaneous or electrical), recurrences of AF occurred in 24 patients (34%). At the end of the follow-up 51 patients (69%) remained in SR. The CoreLab received 93% of the expected ECG transmissions. Patient's overall satisfaction score was 9.1 over 10. CONCLUSION: Digital devices for heart rhythm monitoring can optimize the management of AF patients scheduled for elective CV, preventing unnecessary admissions and providing a more rational use of healthcare resources.

3.
J Am Coll Cardiol ; 84(4): 354-364, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39019530

RESUMO

BACKGROUND: ARTESiA (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation) demonstrated that apixaban, compared with aspirin, significantly reduced stroke and systemic embolism (SE) but increased major bleeding in patients with subclinical atrial fibrillation. OBJECTIVES: To help inform decision making, the authors evaluated the efficacy and safety of apixaban according to baseline CHA2DS2-VASc score. METHODS: We performed a subgroup analysis according to baseline CHA2DS2-VASc score and assessed both the relative and absolute differences in stroke/SE and major bleeding. RESULTS: Baseline CHA2DS2-VASc scores were <4 in 1,578 (39.4%) patients, 4 in 1,349 (33.6%), and >4 in 1,085 (27.0%). For patients with CHA2DS2-VASc >4, the rate of stroke was 0.98%/year with apixaban and 2.25%/year with aspirin; compared with aspirin, apixaban prevented 1.28 (95% CI: 0.43-2.12) strokes/SE per 100 patient-years and caused 0.68 (95% CI: -0.23 to 1.57) major bleeds. For CHA2DS2-VASc <4, the stroke/SE rate was 0.85%/year with apixaban and 0.97%/year with aspirin. Apixaban prevented 0.12 (95% CI: -0.38 to 0.62) strokes/SE per 100 patient-years and caused 0.33 (95% CI: -0.27 to 0.92) major bleeds. For patients with CHA2DS2-VASc =4, apixaban prevented 0.32 (95% CI: -0.16 to 0.79) strokes/SE per 100 patient-years and caused 0.28 (95% CI: -0.30 to 0.86) major bleeds. CONCLUSIONS: One in 4 patients in ARTESiA with subclinical atrial fibrillation had a CHA2DS2-VASc score >4 and a stroke/SE risk of 2.2% per year. For these patients, the benefits of treatment with apixaban in preventing stroke/SE are greater than the risks. The opposite is true for patients with CHA2DS2-VASc score <4. A substantial intermediate group (CHA2DS2-VASc =4) exists in which patient preferences will inform treatment decisions. (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation; NCT01938248).


Assuntos
Aspirina , Fibrilação Atrial , Inibidores do Fator Xa , Pirazóis , Piridonas , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Piridonas/efeitos adversos , Piridonas/administração & dosagem , Aspirina/uso terapêutico , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Inibidores do Fator Xa/uso terapêutico , Medição de Risco/métodos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia
4.
Europace ; 26(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39056247

RESUMO

AIMS: Short-term ambulatory electrocardiogram (ECG) monitoring is often used to assess premature atrial complex (PAC) and premature ventricular complex (PVC) frequency, but the diagnostic reliability is unknown. The objective of this study was to study the day-to-day variability of PAC and PVC frequency. METHODS AND RESULTS: We used 14-day full-disclosure mobile cardiac telemetry recordings without atrial fibrillation in 8245 US patients aged 17-103 years to calculate the diagnostic reliability of shorter ambulatory ECG recordings compared with 14-day averages. Over 14 days, 1853 patients had ≥500 PACs/day, 410 patients had ≥5000 PACs/day, and 197 patients had ≥10 000 PACs/day; 1640 patients had ≥500 PVCs/day, 354 patients had ≥5000 PVCs/day, and 175 patients had ≥10 000 PVCs/day. After 3 days, the estimated daily PAC frequency differed by ≥50% from the 14-day mean in 25% of patients; for PVCs, the corresponding duration was 7 days. Ten days of monitoring were needed to estimate PAC and PVC frequency within ±20% of the overall 14-day frequency in 80% of patients. For daily PAC and PVC frequencies ≥10 000, single-day estimation had a specificity of 99.3% [95% confidence interval (CI) 99.1-99.5] at a sensitivity of 76.6 (95% CI 70.1-80.4%) for PACs and a 99.6% (95% CI 99.4-99.7%) specificity at 79.4 (95% CI 72.7-85.2) sensitivity for PVCs. After 7 days, the sensitivity increased to 88.8% (95% CI 83.6-92.9) for PACs and 86.9% (95% CI 80.9-91.5%) for PVCs. CONCLUSION: While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.


Assuntos
Complexos Atriais Prematuros , Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Feminino , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Adulto , Masculino , Adolescente , Idoso de 80 Anos ou mais , Adulto Jovem , Fatores de Tempo , Telemetria , Valor Preditivo dos Testes , Frequência Cardíaca
5.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38511484

RESUMO

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Assuntos
Fibrilação Atrial , Criocirurgia , Desenho de Equipamento , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Cateteres Cardíacos , Duração da Cirurgia , Agulhas , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Frequência Cardíaca , Potenciais de Ação
6.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-37952132

RESUMO

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Assuntos
Anticoagulantes , Aspirina , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Canadá , Embolia/etiologia , Embolia/prevenção & controle , Hemorragia/induzido quimicamente , Piridonas/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Método Duplo-Cego
7.
J Arrhythm ; 39(6): 963-964, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045470

RESUMO

The shoehorn technique is a simple and safe maneuver that can help to solve difficulties in challenging transseptal sheath crossing for atrial fibrillation cryoablation procedures.

9.
J Electrocardiol ; 81: 250-252, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37862914

RESUMO

We present a case of symptomatic intermittent AV block showing during monitorization alternating bundle branch block. Presuming a high need of pacing, conduction system pacing was considered a more physiological alternative in this patient. Left bundle branch pacing restored a stable atrioventricular synchrony with a paced QRS complex similar to the native one and might be a good alternative in these cases.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Eletrocardiografia , Sistema de Condução Cardíaco
12.
J Electrocardiol ; 61: 137-140, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32599292

RESUMO

ECG of patients with Wolf Parkinson White (WPW) syndrome may simulate other entities such as myocardial infarction, ventricular premature complexes, ventricular bigeminy, accelerated idioventricular rhythm, intermittent bundle branch block or electrical alternans. On the other hand, the opposite can also occur where these other conditions may simulate WPW. We present the case of a young patient referred for WPW ablation showing an incessant accelerated idioventricular rhythm mimicking preexcitation.


Assuntos
Ritmo Idioventricular Acelerado , Síndromes de Pré-Excitação , Síndrome de Wolff-Parkinson-White , Bloqueio de Ramo/diagnóstico , Eletrocardiografia , Humanos , Síndromes de Pré-Excitação/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico
15.
Int J Cardiol ; 278: 104-107, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30318293

RESUMO

Ictal asystole can appear in patients with focal epilepsy, even in early phases. We present our experience of 7 cases, remarking the electrocardiographic characteristics, the role of apnea, treatment and long-term evolution. Awareness of this entity and collaboration between neurologists and cardiologists are essential for a correct diagnosis and management.


Assuntos
Eletrocardiografia/métodos , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Epilepsia/fisiopatologia , Parada Cardíaca/diagnóstico , Parada Cardíaca/fisiopatologia , Adulto , Idoso , Cardiologia/métodos , Epilepsia/epidemiologia , Feminino , Parada Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Neurologia/métodos , Estudos Retrospectivos
16.
J Electrocardiol ; 51(6): 941-944, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30497752

RESUMO

We report on a case of a 78-years-old patient with a subcutaneous implantable cardioverter defibrillator (S-ICD) and an episode of a sustained ventricular tachycardia (VT) at a rate slower than the programmed shock zone. Because of T-wave oversensing the device interpreted it as fast VT that triggered the delivery of an "inappropriately appropriate shock" that terminated it. The patient had again more VT episodes but after programming the SMART pass algorithm (previously programmed "OFF") the device showed no longer frequent T-wave oversensing and no additional inappropriate shocks occurred.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Ventricular/fisiopatologia , Idoso , Falha de Equipamento , Humanos , Masculino
18.
Artigo em Inglês | MEDLINE | ID: mdl-29856082

RESUMO

BACKGROUND: Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic, Minneapolis, MN, USA) has been widely studied, CorVue™ algorithm's (St. Jude Medical, St. Paul, MN, USA) long-term efficacy has not been systematically evaluated in a "real-life" cohort. METHODS: CorVue™ was activated in implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) patients to store information about ITI measures. Clinical events (new episodes of HF requiring treatment and hospitalizations) and CorVue™ data were recorded every 3 months. Appropriate CorVue™ detection for HF was considered if it occurred in the 4 prior weeks to the clinical event. RESULTS: Fifty-three ICD/CRT-D (26 ICD and 27 CRT-D) patients (67 ± 1 years old, 79% male) were included. Device position was subcutaneous in 28 patients. At inclusion, mean left ventricular ejection fraction was 25 ± 7% and 27 patients (51%) were in New York Heart Association class I, 18 (34%) in class II, and eight (15%) in class III. After a mean follow-up of 17 ± 9 months, 105 ITI drops alarms were detected in 32 patients (60%). Only six alarms were appropriate (true positive) and required hospitalization. Eighteen patients (34%) presented 25 clinical episodes (12 hospitalizations and 13 emergency room/ambulatory treatment modifications). Nineteen of these clinical episodes (76%) remained undetected by the CorVue™ (false negative). Sensitivity of CorVue™ resulted in 24%, specificity was 70%, positive predictive value of 6%, and negative predictive value of 93%. CONCLUSIONS: CorVue™ showed a low sensitivity to predict HF events. Therefore, routinely activation of this algorithm could generate misleading information.

19.
J Thorac Dis ; 10(3): 2048-2051, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29707362

RESUMO

Today's pacemakers and defibrillators include diagnostic tools for detecting and treating cardiac arrhythmias like silent atrial fibrillation as atrial high rate episodes (AHREs). This diagnostic capability is crucial to prevent the potential embolic complications this AHREs are related to. However, sometimes data retrieved from diagnostic counters may be misleading reflecting limitations of detection algorithms, which must follow mathematical rules to classify events on a beat-to-beat basis. The incorporation of stored electrograms has been an important milestone in improving the diagnostic capabilities of these devices confirming the arrhythmia diagnosis.

20.
J Electrocardiol ; 51(3): 366-369, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29779524

RESUMO

We present a case series of five patients reporting abnormal automatic mode switching (AMS) episodes during routinary cardiac defibrillator (ICD) and pacemaker (PM) follow-up. This non-previously described phenomenon was reported to St. Jude Medical (Abbott) Technical Support that confirmed the inappropriate automatic mode switching.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Síndrome do QT Longo/terapia , Síndrome do Nó Sinusal/terapia , Taquicardia Ventricular/terapia , Adulto , Idoso , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Síndrome do QT Longo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Síndrome do Nó Sinusal/fisiopatologia , Taquicardia Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA