RESUMO
Perioperative pulmonary embolism can go undetected until the sudden onset of cardiopulmonary collapse. Point of care echocardiography in such setting can narrow the differential diagnosis of precipitous instability and facilitate tailored, rather than empiric, therapy in the event of a massive pulmonary embolism. We describe the diagnosis and successful multidisciplinary management of intraoperative massive pulmonary embolism aided by both transthoracic and transesophageal echocardiography. Key aspects regarding the classification and treatment of pulmonary embolism are subsequently reviewed.
Assuntos
Ponte Cardiopulmonar/métodos , Gerenciamento Clínico , Transplante de Coração , Heparina/efeitos adversos , Hirudinas/administração & dosagem , Transplante de Rim , Fragmentos de Peptídeos/administração & dosagem , Trombocitopenia/induzido quimicamente , Anticoagulantes/administração & dosagem , Antitrombinas/administração & dosagem , Testes de Coagulação Sanguínea , Cardiomiopatias/complicações , Cardiomiopatias/cirurgia , Feminino , Fibrinolíticos/efeitos adversos , Humanos , Pessoa de Meia-Idade , Proteínas Recombinantes/administração & dosagem , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/cirurgia , Trombocitopenia/diagnóstico , Trombocitopenia/terapia , Trombose/prevenção & controleAssuntos
Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Pericárdio , Tampões de Gaze Cirúrgicos/efeitos adversos , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Feminino , Corpos Estranhos/cirurgia , Comunicação Interventricular/cirurgia , Ventrículos do Coração , Humanos , Imageamento por Ressonância Magnética , Toracotomia/métodos , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
Oscillations from cardiac pulsations are normally transmitted to mediastinal structures without any consequence. Autotriggering (AT) of mechanical ventilation occurs when an inspiratory trigger, typically negative inspiratory flow in anesthesia ventilators, is met in the absence of patient effort. AT can lead to respiratory alkalosis, opioid overdose, prolonged mechanical ventilation, and lung hyperinflation. This entity has been reported in both critical care and operating room environments. Increasing the flow trigger usually resolves AT in all cases. We report a case of AT that failed to respond to increasing the flow trigger threshold to its maximal value on the GE Datex-Ohmeda Avance S5® anesthesia station.