1.
Am J Nephrol ; 53(1): 41-49, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35021175

RESUMO

INTRODUCTION: Although arterial hypertension is a major concern in patients with chronic kidney disease (CKD), obtaining accurate systolic blood pressure (SBP) measurement is challenging in this population for whom automatic oscillometric devices may yield erroneous results. METHODS: This cross-sectional study was conducted in 89 patients with stages 4, 5, and 5D CKD, for whom we compared SBP values obtained by the recently described systolic foot-to-apex time interval (SFATI) technique which provides direct SBP determination, the standard technique (Korotkoff sounds), and oscillometry. We investigated the effects of age, sex, diabetes, CKD stage, and pulse pressure to explain measurement errors defined as biases or misclassification relative to the SBP thresholds of 110-130-mm Hg. RESULTS: All 3 techniques showed satisfactory reproducibility for SBP measurement (CCC > 0.84 and >0.91, respectively, in dialyzed and nondialyzed patients). The mean ± SD from SBP as determined via Korotkoff sounds was 1.7 ± 4.6 mm Hg for SFATI (CCC = 0.98) and 5.9 ± 9.3 mm Hg for oscillometry (CCC = 0.88). Referring to the 110-130-mm Hg SBP range outside which treatment prescription or adaptation is recommended for CKD patients, SFATI underestimated SBP in 3 patients and overestimated it in 1, whereas oscillometry underestimated SBP in 12 patients and overestimated it in 3. Higher pulse pressure was the main explanatory factor for measurement and classification errors. DISCUSSION/CONCLUSION: SFATI provides accurate SBP measurements in patients with severe CKD and paves the way for the standardization of automated noninvasive blood pressure measurement devices. Before prescribing or adjusting antihypertensive therapy, physicians should be aware of the risk of misclassification when using oscillometry.


Assuntos
Insuficiência Renal Crônica , Pressão Sanguínea , Estudos Transversais , Feminino , Humanos , Masculino , Oscilometria/métodos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Reprodutibilidade dos Testes
2.
J Hypertens ; 35(5): 1002-1010, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28099195

RESUMO

BACKGROUND: Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of the oscillometric signal, which reaches a maximum concomitant with the first Korotkoff sound. METHOD: In 145 study participants and patients (group 1), we measured the systolic brachial artery blood pressure by Korotkoff sound recording, conventional oscillometry, and our fully automated systolic peak foot-to-apex time interval (SFATI) technique. In 35 other patients (group 2), we compared SFATI with intra-arterial measurement. RESULTS: In group 1, the concordance correlation coefficient was 0.989 and 0.984 between SFATI and Korotkoff sounds, 0.884 and 0.917 between oscillometry and Korotkoff sounds, and 0.882 and 0.919 between SFATI and oscillometry, respectively, on the left and right arm. In group 2, it was 0.72 between SFATI and intra-arterial measurement, 0.67 between oscillometry and intra-arterial measurement, and 0.92 between SFATI and Korotkoff sounds. In 40 study participants, the reproducibility study yielded a concordance coefficient of 0.95 for SFATI and 0.94 for Korotkoff sounds. CONCLUSION: SFATI BP measurement shows an excellent concordance with the auscultatory technique, offering a major improvement over current oscillometric techniques and allowing standardization.


Assuntos
Determinação da Pressão Arterial/métodos , Pressão Sanguínea , Oscilometria , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artéria Braquial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Reprodutibilidade dos Testes , Sístole , Adulto Jovem