Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Terahertz Sci Technol ; 5(2): 170-183, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26322247

RESUMO

Terahertz (THz) spectral properties of human cornea are explored as a function of central corneal thickness (CCT) and corneal water content, and the clinical utility of THz-based corneal water content sensing is discussed. Three candidate corneal tissue water content (CTWC) perturbations, based on corneal physiology, are investigated that affect the axial water distribution and total thickness. The THz frequency reflectivity properties of the three CTWC perturbations were simulated and explored with varying system center frequency and bandwidths (Q-factors). The modeling showed that at effective optical path lengths on the order of a wavelength the cornea presents a lossy etalon bordered by air at the anterior and the aqueous humor at the posterior. The simulated standing wave peak-to-valley ratio is pronounced at lower frequencies and its effect on acquired data can be modulated by adjusting the bandwidth of the sensing system. These observations are supported with experimental spectroscopic data. The results suggest that a priori knowledge of corneal thickness can be utilized for accurate assessments of corneal tissue water content. The physiologic variation of corneal thickness with respect to the wavelengths spanned by the THz band is extremely limited compared to all other structures in the body making CTWC sensing unique amongst all proposed applications of THz medical imaging.

2.
IEEE Trans Terahertz Sci Technol ; 5(2): 184-196, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26161292

RESUMO

A pulsed terahertz (THz) imaging system and millimeter-wave reflectometer were used to acquire images and point measurements, respectively, of five rabbit cornea in vivo. These imaging results are the first ever produced of in vivo cornea. A modified version of a standard protocol using a gentle stream of air and a Mylar window was employed to slightly dehydrate healthy cornea. The sensor data and companion central corneal thickness (CCT) measurements were acquired every 10-15 min over the course of two hours using ultrasound pachymmetry.. Statistically significant positive correlations were established between CCT measurements and millimeter wave reflectivity. Local shifts in reflectivity contrast were observed in the THz imagery; however, the THz reflectivity did not display a significant correlation with thickness in the region probed by the 100 GHz and CCT measurements. This is explained in part by a thickness sensitivity at least 10× higher in the mm-wave than the THz systems. Stratified media and effective media modeling suggest that the protocol perturbed the thickness and not the corneal tissue water content (CTWC). To further explore possible etalon effects, an additional rabbit was euthanized and millimeter wave measurements were obtained during death induced edema. These observations represent the first time that the uncoupled sensing of CTWC and CCT have been achieved in vivo.

3.
Ocul Surf ; 13(1): 43-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25557345

RESUMO

A mid-infrared (IR) source at ∼ 3 µm radiation is used as a probe to measure hydration in porcine cornea. Since the Er(3+):YAG emission targets vibrational modes (around 3300 cm(-1)) in the H2O molecule, it is highly sensitive to changes in water content in the first ∼ 10 µm of the corneal tissue.


Assuntos
Água Corporal/metabolismo , Córnea/química , Doenças da Córnea/metabolismo , Raios Infravermelhos , Lasers , Monitorização Fisiológica/métodos , Animais , Doenças da Córnea/diagnóstico , Modelos Animais de Doenças , Suínos
4.
J Biomed Opt ; 17(4): 040503, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559669

RESUMO

A reflective, pulsed terahertz (THz) imaging system was used to acquire high-resolution (d(10-90)/λ~1.925) images of deep, partial thickness burns in a live rat. The rat's abdomen was burned with a brass brand heated to ~220°C and pressed against the skin with contact pressure for ~10 sec. The burn injury was imaged beneath a Mylar window every 15 to 30 min for up to 7 h. Initial images display an increase in local water concentration of the burned skin as evidenced by a marked increase in THz reflectivity, and this likely correlates to the post-injury inflammatory response. After ~1 h the area of increased reflectivity consolidated to the region of skin that had direct contact with the brand. Additionally, a low reflecting ring of tissue could be observed surrounding the highly reflective burned tissue. We hypothesize that these regions of increased and decreased reflectivity correlate to the zones of coagulation and stasis that are the classic foundation of burn wound histopathology. While further investigations are necessary to confirm this hypothesis, if true, it likely represents the first in vivo THz images of these pathologic zones and may represent a significant step forward in clinical application of THz technology.


Assuntos
Queimaduras/patologia , Processamento de Sinais Assistido por Computador , Imagem Terahertz/métodos , Animais , Técnicas Histológicas , Masculino , Ratos , Ratos Sprague-Dawley
5.
J Biomed Opt ; 16(5): 057003, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639581

RESUMO

This work introduces the potential application of terahertz (THz) sensing to the field of ophthalmology, where it is uniquely suited due to its nonionizing photon energy and high sensitivity to water content. Reflective THz imaging and spectrometry data are reported on ex-vivo porcine corneas prepared with uniform water concentrations using polyethylene glycol (PEG) solutions. At 79% water concentration by mass, the measured reflectivity of the cornea was 20.4%, 14.7%, 11.7%, 9.6%, and 7.4% at 0.2, 0.4, 0.6, 0.8, and 1 THz, respectively. Comparison of nine corneas hydrated from 79.1% to 91.5% concentration by mass demonstrated an approximately linear relationship between THz reflectivity and water concentration, with a monotonically decreasing slope as the frequency increases. The THz-corneal tissue interaction is simulated with a Bruggeman model with excellent agreement. THz applications to corneal dystrophy, graft rejection, and refractive surgery are examined from the context of these measurements.


Assuntos
Água Corporal/química , Córnea/química , Técnicas de Diagnóstico Oftalmológico/instrumentação , Espectroscopia Terahertz/instrumentação , Água/análise , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Suínos
6.
IEEE Trans Terahertz Sci Technol ; 1(1): 201-219, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26085958

RESUMO

The application of THz to medical imaging is experiencing a surge in both interest and federal funding. A brief overview of the field is provided along with promising and emerging applications and ongoing research. THz imaging phenomenology is discussed and tradeoffs are identified. A THz medical imaging system, operating at ~525 GHz center frequency with ~125 GHz of response normalized bandwidth is introduced and details regarding principles of operation are provided. Two promising medical applications of THz imaging are presented: skin burns and cornea. For burns, images of second degree, partial thickness burns were obtained in rat models in vivo over an 8 hour period. These images clearly show the formation and progression of edema in and around the burn wound area. For cornea, experimental data measuring the hydration of ex vivo porcine cornea under drying is presented demonstrating utility in ophthalmologic applications.

7.
Artigo em Inglês | MEDLINE | ID: mdl-21095725

RESUMO

An indicator of ocular health is the hydrodyanmics of the cornea. Many corneal disorders deteriorate sight as they upset the normal hydrodynamics of the cornea. The mechanisms include the loss of endothelial pump function of corneal dystophies, swelling and immune response of corneal graft rejection, and inflammation and edema, which accompany trauma, burn, and irritation events. Due to high sensitivity to changes of water content in materials, a reflective terahertz (300 GHz and 3 THz) imaging system could be an ideal tool to measure the hydration level of the cornea. This paper presents the application of THz technology to visualize the hydration content across ex vivo porcine corneas. The corneas, with a thickness variation from 470 - 940 µm, were successfully imaged using a reflective pulsed THz imaging system, with a maximum SNR of 50 dB. To our knowledge, no prior studies have reported on the use of THz in measuring hydration in corneal tissues or other ocular tissues. These preliminary findings indicate that THz can be used to accurately sense hydration levels in the cornea using a pulsed, reflective THz imaging system.


Assuntos
Água Corporal/fisiologia , Doenças da Córnea/diagnóstico , Espectroscopia Terahertz/métodos , Animais , Córnea/patologia , Doenças da Córnea/patologia , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Olho/patologia , Processamento de Imagem Assistida por Computador , Inflamação , Polipropilenos/química , Reprodutibilidade dos Testes , Suínos , Visão Ocular
8.
J Pharm Sci ; 99(9): 3698-710, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19844959

RESUMO

The effect of temperature on the chemical stability of an amorphous spray-dried insulin powder formulation (Exubera) was evaluated in the solid state at constant moisture content. The chemical stability of the powder was assessed using reversed-phase high-performance liquid chromatography (RP-HPLC) and high-performance-size exclusion chromatography (HP-SEC). The major degradants in spray-dried insulin produced during heat stressing were identified as A21-desamidoinsulin (A21) and high molecular weight protein (HMWP). As expected, the rates of formation of A21 and HMWP were observed to increase with temperature. A stretched-time kinetic model (degradation rate is proportional to the square root of time) was applied to the degradant profiles above and below the glass transition temperature (T(g)) and apparent reaction rate constants were determined. Below T(g), isothermal enthalpy of relaxation measurements were used to assess the effect of temperature on molecular mobility. The formation of A21 and HMWP was found to follow an Arrhenius temperature dependence above and below the T(g). Comparison of reaction rate constants to those estimated from structural relaxation experiments suggests that the reaction pathways to form A21 and HMWP below the T(g) may be coupled with the molecular motions involved in structural relaxation.


Assuntos
Insulina/química , Estabilidade de Medicamentos , Cinética , Difração de Pó , Pós , Proteínas Recombinantes/química , Temperatura de Transição , Difração de Raios X
9.
Stud Health Technol Inform ; 129(Pt 1): 545-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17911776

RESUMO

The National Library of Medicine has developed a tool to identify medical concepts from the Unified Medical Language System in free text. This tool - MetaMap (and its java version MMTx) has been used extensively for biomedical text mining applications. We have developed a module for MetaMap which has a high performance in terms of processing speed. We evaluated our module independently against MetaMap for the task of identifying UMLS concepts in free text clinical radiology reports. A set of 1000 sentences from neuro-radiology reports were collected and processed using our technique and the MMTx Program. An evaluation showed that our technique was able to identify 91% of the concepts found by MMTx in 14% of the time taken by MMTx. An error analysis showed that the missing concepts were largely those which were not direct lexical matches but inferential matches of multiple concepts. Our method also identified multi-phrase concepts which MMTx failed to identify. We suggest that this module be implemented as an option in MMTx for real-time text mining applications where single concepts found in the UMLS need to be identified.


Assuntos
Armazenamento e Recuperação da Informação/métodos , Processamento de Linguagem Natural , Unified Medical Language System , Humanos , Sistemas Computadorizados de Registros Médicos , Neurologia , Serviço Hospitalar de Radiologia , Sistemas de Informação em Radiologia
10.
Diabetes Technol Ther ; 9 Suppl 1: S16-27, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17563300

RESUMO

The Exubera system (Pfizer, New York, NY/Nektar Therapeutics, San Carlos, CA) is an integration of five major new technologies: protein formulation, powder processing, powder filling, drug packaging, and delivery device. The product provides a simple interface, where the patient interacts only with the delivery device and powder packaging. These components were designed together to assure repeatable dosing when used by a wide range of patients under real-world life-style and handling conditions. The device design is purely mechanical, using patient-generated compressed air as the energy source. Upon actuation, a sonic discharge of air through the novel release unit reproducibly extracts, de-agglomerates, and disperses the inhalation powder into a respirable aerosol. A clear holding chamber allows for patient feedback via dose visualization and separates aerosol cloud generation from the inspiratory effort. The Exubera product was tested under a wide range of typical use conditions and potential misuse scenarios and following long-term usage in clinical trials. These comprehensive characterization programs demonstrated robust aerosol and mechanical performance, confirming the design intent of the inhaler. These studies provide assurance of consistent and reliable dose delivery in a real-world use of the product.


Assuntos
Administração por Inalação , Insulina/uso terapêutico , Pulmão/fisiologia , Aerossóis , Desenho de Equipamento , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/farmacocinética , Termodinâmica , Resultado do Tratamento
11.
J Pharm Sci ; 94(9): 1861-80, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16052511

RESUMO

Pharmaceutical solids have generally been characterized as either three-dimensional crystals or amorphous solids based on X-ray powder diffraction and modulated temperature differential scanning calorimetry. In contrast, fewer examples of thermotropic and lyotropic liquid crystals, or mesophases, appear in the pharmaceutical literature, and that literature teaches that the aforementioned analytical techniques should be complemented with polarized light microscopy and small-angle X-ray scattering in order to effectively identify potential liquid crystalline states. Lyotropic liquid crystals are induced by the presence of solvent, and have been extensively described elsewhere in the context of emulsion technology; however, other pharmaceutical examples are emerging. Thermotropic liquid crystals are induced by a change in temperature and are essentially free of solvent, where more pharmaceutical applications appear in the literature. In the present review the general structural characteristics that favor the formation of liquid crystalline mesophases are categorized by therapeutic target and molecular size, and the analytical means of their identification are presented.


Assuntos
Cristais Líquidos/química , Substâncias Macromoleculares/química , Soluções Farmacêuticas/química , Transição de Fase , Amiloide/química , Antibacterianos/química , Anti-Inflamatórios não Esteroides/química , Antifúngicos/química , Antineoplásicos/química , Química Farmacêutica , Cristalização , Ciclosporina/química , Fenoprofeno/química , Hipoglicemiantes/química , Imunossupressores , Polipeptídeo Amiloide das Ilhotas Pancreáticas , Itraconazol/química , Metotrexato/química , Nafcilina/química , Solventes , Temperatura de Transição
12.
Diabetes Technol Ther ; 7(6): 896-906, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16386095

RESUMO

Development of a product for pulmonary delivery of insulin presented significant technology challenges for this first-in-class pharmaceutical product. These included developing (a) a chemically stabilized protein, (b) a dry powder formulation exhibiting required aerosol physical characteristics, (c) low-dose powder filling and packaging technology, and (d) a mechanical device for powder dispersal and reliable dosing to the patient. The insulin drug is formulated using a novel excipient combination to create a powder with a high glass transition temperature (Tg). The high Tg minimizes insulin mobility (thus reactivity), enabling ambient storage conditions. The formulation composition results in minimal hygroscopicity, where customized packaging produced product ruggedness to humidity. The formulated insulin powder is manufactured by spray-drying. This technology was further engineered to produce the desired reproducible powder characteristics with tight control over particle size and moisture content. A solution step prior to drying assures homogeneity and minimizes dependence on the physical form of the components. Novel low-dose filling and packaging technology reproducibly meters milligram quantities of microfine powder to meet stringent quality requirements for dose control. The technology for accurate, uniform, high-throughput metering of drug powders allows for automation and is scaleable for commercial operations. Finally, the mechanical device design provides powder deagglomeration and dispersion processes in a reusable dry powder inhaler with unique characteristics. The device was designed to rely on patient-generated compressed air as the energy source. A sonic discharge of air through the novel TransJector reproducibly extracts, deagglomerates, and disperses the inhalation powder. A clear holding (spacer-type) chamber allows for patient feedback via dose visualization, and separates powder dispersal from the inspiratory effort. The EXUBERA [Pfizer (New York, NY) and sanofi-aventis (Paris, France)] product provides insulin into the bloodstream with similar reproducibly and effectiveness as subcutaneous injections.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/administração & dosagem , Insulina/química , Administração por Inalação , Fenômenos Químicos , Química Farmacêutica , Físico-Química , Humanos , Inaladores Dosimetrados , Tamanho da Partícula
13.
J Pharm Sci ; 92(9): 1821-31, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12950000

RESUMO

A new solid-state form of cyclosporine produced by spray-drying exhibited characteristics consistent with a liquid crystal. No sharp diffraction peaks were observed by powder X-ray diffraction; however, analysis by both small-angle X-ray diffraction (SAXR) and microscopic under polarized light (PLM) confirmed the existence of two-dimensional ordered liquid crystal. Hot stage microscopy revealed a solid-to-liquid transition, in the range of 118 to 125 degrees C. Moreover, the solid-to-liquid transition showed frequency dependence by dielectric analysis (DEA), and was coincidental with a stepwise heat capacity change measured by differential scanning Calorimetry (DSC). The two-dimensional order was maintained above the solid-to-liquid transition temperature indicated by low-angle diffraction by SAXR and birefringence by PLM. However, birefringence was lost at temperatures above 170 degrees C, indicating the conversion of the liquid crystal into an isotropic liquid. In situ annealing experiments, by DSC, revealed the presence of an endotherm, unexplained by either a phase transition or solvent loss, and it is believed to be the result of a structural rearrangement that has no impact on the macroscopic properties of the material. Spray-dried cyclosporine at room temperature is therefore a frozen thermotropic liquid crystal due to the presence of two-dimensional order and the lack of substantial residual solvent. This is, to our knowledge, the first report of the existence of a thermotropic liquid crystal of a naturally occurring peptide.


Assuntos
Ciclosporina/química , Imunossupressores/química , Varredura Diferencial de Calorimetria/métodos , Química Farmacêutica , Estabilidade de Medicamentos , Microscopia Eletrônica de Varredura/métodos , Microscopia de Polarização/métodos , Estrutura Molecular , Análise Espectral/métodos , Temperatura , Termogravimetria/métodos , Água , Difração de Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...