Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 164: 789-807, 2019 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-30503802

RESUMO

Sitagliptin was stored at high temperature/high humidity, dry hot air, UV/VIS light and different pH. Then, a selective LC-UV method was developed for determination of sitagliptin in the presence of degradation products and for estimation of degradation kinetics. Because parent drugs can react with excipients in final pharmaceutical formulations, stability of sitagliptin was also examined in the presence of excipients of different reactivity, using FT-IR and LC-UV methods. Finally, LC-MS method was used for identification of degradation products of sitagliptin. High degradation of sitagliptin, following the first order kinetics, was observed in strongly acidic, alkaline and oxidative media. The quickest degradation was found in 2 M HCl and 2 M NaOH. In addition, all excipients used in the present study, i.e. fumaric acid, lactose, mannitol and magnesium stearate showed potent interactions with sitagliptin. Some of these interactions were shown without any stress while others were accelerated by high temperature/high humidity and dry hot air, and less by UV/VIS light. Some mechanisms for the observed changes were proposed, i.e. the Michael addition in the presence of fumaric acid and the Maillard reaction in the presence of lactose. In addition, degradation of sitagliptin together with the occurrence of its impurities was stated in a broad range of stress conditions.


Assuntos
Inibidores da Dipeptidil Peptidase IV/análise , Contaminação de Medicamentos/prevenção & controle , Estabilidade de Medicamentos , Fosfato de Sitagliptina/análise , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Inibidores da Dipeptidil Peptidase IV/química , Excipientes/química , Umidade , Fosfato de Sitagliptina/química , Espectroscopia de Infravermelho com Transformada de Fourier/instrumentação , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Raios Ultravioleta
2.
Chem Biol Drug Des ; 91(4): 915-923, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29220872

RESUMO

This study describes the synthesis, lipophilicity and in vitro antimicrobial assays of 15 new hydrazide-hydrazones of isonicotinic acid. New derivatives were obtained on the basis of the condensation reaction of isonicotinic acid hydrazide with different aromatic aldehydes. The chemical structure of synthesized compounds was confirmed by spectral methods. Experimental lipophilicity of new isonicotinic acid derivatives was determined using reversed-phase thin-layer chromatography. All synthesized compounds were subjected to in vitro antimicrobial assays against reference strains of Gram-positive bacteria, Gram-negative bacteria and fungi belonging to Candida spp. Some of the synthesized hydrazide-hydrazones proved to be significant antibacterial compounds and more potent than commonly used chemotherapeutic agents.


Assuntos
Anti-Infecciosos/síntese química , Hidrazonas/química , Ácidos Isonicotínicos/química , Anti-Infecciosos/química , Anti-Infecciosos/farmacologia , Candida/efeitos dos fármacos , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Ácidos Isonicotínicos/síntese química , Ácidos Isonicotínicos/farmacologia , Testes de Sensibilidade Microbiana , Relação Estrutura-Atividade
3.
RSC Adv ; 8(63): 36076-36089, 2018 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-35558458

RESUMO

Indapamide and dihydralazine can be combined in fixed-dose formulations because of their complementary actions against hypertension. On the other hand, combined formulations present the problem of chemical interactions between the active ingredients, e.g. accelerated degradation of constituents or generation of quite new degradation products. Therefore, the main goal of the present study was to examine the chemical stability of indapamide and dihydralazine, as individuals and as a mixture, to detect potent interactions between both constituents, using FT-IR, HPLC and LC-MS methods. It was clearly shown that both drugs degraded more when they were in the mixture, i.e. indapamide was degraded more under high temperature/high humidity while dihydralazine was more sensitive to UV/VIS light. In solutions, indapamide was sensitive to strong acidic and strong alkaline conditions while dihydralazine degraded at pH ≥ 7. Generally, the process of degradation of indapamide and dihydralazine followed first order kinetics. The fastest degradation of both indapamide and dihydralazine was found at pH ≥ 10. Several degradation products of indapamide and dihydralazine were detected and identified by our LC-MS method. Interactions between both drugs were confirmed by detection of new degradation products of indapamide, i.e. 4-chloro-3-sulfamoylbenzamide and 4-chloro-3-(formylsulfamoyl)-N-(2-methyl-2,3-dihydro-1H-indol-1-yl)benzamide, only in the presence of dihydralazine.

5.
J AOAC Int ; 93(4): 1086-92, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20922938

RESUMO

For type 2 diabetes treatment, combinations of drugs from the thiazolidinedione and sulfonylurea groups are now available in the same tablet or capsule. Therefore, a stability-indicating and validated HPLC method was developed for simultaneous determination of pioglitazone, rosiglitazone, and glipizide in combined dosage forms. The examined drugs were subjected to different conditions such as acid and base, temperature, and UV light, and degradation of pioglitazone and glipizide was observed under thermal and acidic stress. However, selectivity of the presented method for pioglitazone, rosiglitazone, and glipizide assay against their degradation products was confirmed. It was also demonstrated to be robust, resisting small deliberate changes in pH of the buffer, flow rate, and percentage of acetonitrile in the mobile phase. The presented method utilizes a LiChrospher RP18 column (125 x 4.0 mm), acetonitrile in phosphate buffer at pH 4.3 (40 + 60, v/v) as the mobile phase, and UV detection at 225 nm for pioglitazonel glipizide or 245 nm for rosiglitazone/glipizide. The method was validated with respect to linearity, precision, and accuracy. Finally, the elaborated procedure was applied for the QC of pioglitazone/glipizide and rosiglitazone/glipizide mixtures.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hipoglicemiantes/análise , Compostos de Sulfonilureia/análise , Tiazolidinedionas/análise , Calibragem , Combinação de Medicamentos , Estabilidade de Medicamentos , Hipoglicemiantes/química , Compostos de Sulfonilureia/química , Tiazolidinedionas/química
6.
J Pharm Biomed Anal ; 53(4): 911-8, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20655160

RESUMO

The lipophilicity of a compound is a fundamental property related to pharmaceutical and biomedical activity. As many approaches are mixed together in every-day published studies, the subject needs some standardization. The paper presents a comparative study on several approaches of TLC lipophilicity determination: a single TLC run, extrapolation of a retention, principal component analysis of a retention matrix, PARAFAC on a three-way array and a PLS regression. All techniques were applied to 35 model solutes with simple molecules, using nine concentrations of six modifiers: acetonitrile, acetone, dioxane, propan-2-ol, methanol and tetrahydrofurane. The elaborated comparative analysis formed several general recommendations. Methanol and dioxane were the best modifiers, while acetonitrile gave the worst and inacceptable correlation of retention with lipophilicity. Surprisingly, good correlations were obtained for the single TLC runs and this method is underestimated in the literature. The advanced chemometric processing proposed recently, such as PCA, PARAFAC and PLS did not show a visible advantage comparing to classical methods. A need to use a robust regression and robust correlation measures, due to presence of significant outliers, was also noticed and studied.


Assuntos
Cromatografia em Camada Fina/métodos , Solubilidade , Análise dos Mínimos Quadrados , Análise de Componente Principal
7.
J AOAC Int ; 89(2): 319-25, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16640279

RESUMO

A new high-performance liquid chromatography method was developed and validated for the quantitation of gliclazide and repaglinide in pharmaceutical formulations. Determination was performed using a LiChroCART RP-18 column, a mobile phase containing acetonitrile-phosphate buffer (pH 2.1; 60 + 40, v/v), and ultraviolet (UV) detection at 225 nm. Repaglinide was used as an internal standard for gliclazide determination and gliclazide for repaglinide assay. The method was validated with respect to linearity, precision, robustness, ruggedness, accuracy, and specificity. The calibration graphs ranged from 0.015 to 0.09 mg/mL for gliclazide and 0.06 to 0.36 mg/mL for repaglinide. Intra- and interday relative standard deviation values for the standard solutions were 0.70 and 1.01% for gliclazide and 0.78 and 0.93% for repaglinide, respectively. Total recoveries of gliclazide and repaglinide from the laboratory-prepared mixtures were 99.82 +/- 0.58 and 101.50 +/- 0.46% for gliclazide and repaglinide, respectively [mean +/- standard deviation (SD)]. In forced degradation studies, the effect of acid, base, oxidation, UV light, and temperature on both drugs was also investigated. Finally, the method was applied for the quality control of commercial gliclazide and repaglinide tablets. Total recovery was 100.40 +/- 0.35 and 104.46 +/- 0.23% for gliclazide and repaglinide, respectively (mean +/- SD).


Assuntos
Carbamatos/análise , Gliclazida/análise , Hipoglicemiantes/análise , Piperidinas/análise , Calibragem , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...