RESUMO
ABSTRACT Purpose: This study aimed to evaluate the perception and degree of satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic interface. Methods: Two scenarios with different obstacles were created to conduct tests with the canes (the user's cane and the prototype one). The perception and satisfaction of participants regarding the electronic cane were assessed using a questionnaire, the number of collisions during the tests, and the time each individual took to complete the course in each scenario. Results: Ten blind individuals who used the white cane participated in this study. Eight were males, and two were females. Their age ranged from 23 to 43 (average 32.3 ± 7.13 years and median 32 years). There was a tendency for fewer collisions with ground obstacles when the electronic cane was used than when the white cane was used. However, there was no statistically significant difference between the number of collisions and the course completion time in each scenario with either canes tested. Conclusion: Overall, the perception and satisfaction of individuals regarding the prototype used were positive.
RESUMO
PURPOSE: This study aimed to evaluate the perception and degree of satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic interface. METHODS: Two scenarios with different obstacles were created to conduct tests with the canes (the user's cane and the prototype one). The perception and satisfaction of participants regarding the electronic cane were assessed using a questionnaire, the number of collisions during the tests, and the time each individual took to complete the course in each scenario. RESULTS: Ten blind individuals who used the white cane participated in this study. Eight were males, and two were females. Their age ranged from 23 to 43 (average 32.3 ± 7.13 years and median 32 years). There was a tendency for fewer collisions with ground obstacles when the electronic cane was used than when the white cane was used. However, there was no statistically significant difference between the number of collisions and the course completion time in each scenario with either canes tested. CONCLUSION: Overall, the perception and satisfaction of individuals regarding the prototype used were positive.
Assuntos
Bengala , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Adulto , Adulto Jovem , Inquéritos e Questionários , Desenho de Equipamento , Cegueira/psicologia , Pessoas com Deficiência Visual/psicologia , Percepção , Satisfação Pessoal , Fatores de Tempo , Tato , Estatísticas não ParamétricasRESUMO
PURPOSE: To investigate disparities in the prevalence and causes of visual impairment and blindness, cataract surgical coverage, and ocular findings in older adults from two Brazilian geo-socio-demographic areas, São Paulo and Parintins cities. METHODS: Data from two population-based studies including participants 50 years and older from the cities of São Paulo (São Paulo Eye Study - SPES, 2004) and Parintins (Brazilian Amazon Region Eye Survey - BARES, 2014) were aggregated. RESULTS: A total of 5318 participants (3677 from SPES;1641 from BARES) were included. The prevalence of severe visual impairment (SVI) and blindness were, respectively, 0.74% (0.46-1.02) and 0.77% (0.48-1.05) in SPES and 1.72% (1.09-2.35) and 3.44% (2.55-4.33) in BARES. SVI and blindness were associated with BARES study [OR = 2.27 (1.30-3.95); p = .004 - SVI] [OR:4.07 (2.51-6.60); p < .001- blindness]; and older age [OR = 10.93 (4.20-28.45); p < .001 - SPES; OR = 17.96 (8.75-36.83); p < .001 - BARES] while higher education level was a protective factor [OR = 0.21 (0.05-0.95) - SPES; p = .042; OR = 0.21 (0.05-0.91); p = .037 - BARES]. Cataract was the main cause of bilateral severe visual impairment (25.93% in SPES and 64.29% in BARES) and bilateral blindness (21.43% in SPES and 35.71% in BARES). Cataract surgical coverage was significantly lower in BARES (36.32%) compared to SPES (57.75%). CONCLUSION: The prevalence of SVI and blindness was three times higher in older adults from the Brazilian Amazon compared to those living in São Paulo city, despite a 10-year interval between the two studies. These disparities should be mitigated by initiatives to promote access to eye care services targeting underprivileged and remote Brazilian areas.
Assuntos
Extração de Catarata , Catarata , Baixa Visão , Humanos , Idoso , Estudos Transversais , Brasil/epidemiologia , Prevalência , Acuidade Visual , Cegueira/epidemiologia , Cegueira/etiologia , Baixa Visão/epidemiologia , Baixa Visão/etiologia , Transtornos da Visão/epidemiologia , Catarata/complicações , Catarata/epidemiologia , Extração de Catarata/efeitos adversosRESUMO
PURPOSE: To measure the central corneal thickness (CCT) using anterior segment optical coherence tomography (AS-OCT) in older adults with and without pterygium from the Brazilian Amazon Region Eye Survey (BARES). METHODS: BARES is a population-based epidemiological cross-sectional study conducted in Parintins city. Participants were residents ≥45 years of age identified through a door-to-door interview. Eligible participants were invited for a comprehensive eye exam. Pterygium occurrence and severity were assessed by ophthalmologists through slit-lamp examination considering its location (nasal or/and temporal) and severity (lesion with extension <3â mm, ≥3â mm not reaching the pupillary margin or ≥3â mm reaching the pupillary margin). CCTs were obtained and measurements from the more severely affected eye were included. Images were analyzed offline by masked observers. RESULTS: A total of 671 subjects, 533 (79.4%) with pterygium in at least one eye and 138 (20.6%) without pterygium in either eye, were examined. The mean CCT evaluated by multiple linear regression and adjusted for demographic variables and pterygium severity was 521 ± 34â µm (median = 521; range = 304-665). Decreased CCT was significantly associated with age and pterygium severity. Individuals aged 65-74 years had CCT 7â µm thinner than those aged 45-54 years (p = 0.044), individuals aged 75 years and older had CCT 15â µm thinner than those aged 45-54 years (p = 0.001), and eyes with severe pterygium had CCT 33â µm thinner than eyes without pterygium (p < 0.001). CONCLUSIONS: The CCT analysis in this population-based sample shows that a thinner cornea is associated with pterygium severity and older age.
Assuntos
Pterígio , Humanos , Idoso , Pessoa de Meia-Idade , Pterígio/diagnóstico , Pterígio/patologia , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Córnea/patologia , Reprodutibilidade dos Testes , Paquimetria Corneana/métodosRESUMO
PURPOSE: To investigate the impact of Boston Type I Keratoprosthesis (BI-Kpro) implantation on retinal and visual pathway function, respectively, assessed by full-field electroretinography (ERG) and visually evoked potentials (VEPs). METHODS: This is a prospective interventional longitudinal study, and patients with BI-Kpro implantation were assessed preoperatively and at 3 and 12 months after surgery. ERG, flash, and pattern-reversal VEPs (15' and 60' checks) along with visual acuity (VA) were performed. RESULTS: A total of 13 patients (24 to 88 years of age) were included. Mean baseline VA (logMAR) improved from 2.30 to 1.04 at 3 months and to 1.00 at 12 months. Flash VEPs were normal in 6 (46%) patients and in 10 (77%) patients at the 12-month follow-up. PVEP was non-detectable in all patients preoperatively for both check sizes. For 15' check size, 6 (46%) patients showed responses after 3 and 12 months except for 1 patient with normal responses at 12 months with the remaining non-detectable. For 60' checks, 11 (85%) patients had responses 3 months after surgery with only 9 (70%) showing responses at 12 months. Abnormal full-field ERGs were found in all patients preoperatively. Amplitude improvement was found in 10 (77%) patients from baseline to 3 months and in 8 (62%) patients from the 3- to the 12-month follow-up. CONCLUSIONS: In this small cohort of patients with BI-Kpro implantation, a remarkable improvement on visual function quantitatively assessed by electrophysiological testing was found in the majority of cases. Visual electrophysiological testing can contribute to objectively assess functional outcomes in this population.
Assuntos
Córnea , Doenças da Córnea , Humanos , Córnea/cirurgia , Vias Visuais , Estudos Prospectivos , Estudos Longitudinais , Próteses e Implantes , Doenças da Córnea/cirurgia , Potenciais Evocados VisuaisRESUMO
PURPOSE: To investigate the diagnostic contribution of grating visual acuity (GVA) measured by sweep pattern-reversal visually evoked potentials (SPRVEP) in unexplained visual loss (UVL). METHODS: This case-control study included adult patients under suspicion of UVL referred to SPRVEP and transient pattern-reversal visually evoked potentials (TPRVEP) testing. Optotype visual acuity (OVA) was measured by ETDRS 4-meter chart and GVA by SPRVEP. UVL patients were assigned into three distinctive categories, according to the presence of ocular disease, motivation, and electrophysiological evaluation, as follows: exaggerators, malingerers, and psychogenic. Healthy controls and patients with organic visual loss were also tested. Receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of GVA and TPRVEP parameters. RESULTS: A total of 76 patients with UVL were analyzed: 60 (79.0%) exaggerators, 11 (14.4%) malingerers, and 5 (6.6%) psychogenic. Controls were 49 subjects evaluated for TPRVEP and 28 subjects for SPRVEP. There were 13 patients with organic visual loss enrolled. Mean difference between OVA and GVA was 1.19±0.67 (median=0.84; 95% CI: 1.04 to 1.34) in UVL and 0.14 ±0.09 (median= 0.14; 95% CI: 0.08 to 0.20) in organic visual loss. The area under the ROC curve (AUC) of GVA to distinguish UVL from healthy controls was 0.998 with a cutoff of 0.09 logMAR showing specificity of 100% and sensitivity of 96.0%. CONCLUSIONS: GVA measured by SPRVEP had good diagnostic validity to discriminate patients with unexplained visual loss from healthy controls and patients with organic visual loss, demonstrating its contribution to the diagnosis of this condition.
Assuntos
Potenciais Evocados Visuais , Transtornos da Visão , Adulto , Cegueira , Estudos de Casos e Controles , Potenciais Evocados , Humanos , Transtornos da Visão/diagnóstico , Acuidade VisualRESUMO
Cataract is a highly prevalent, treatable, and sight threatening condition considered one of the main focuses of public health policies addressing visual impairment and blindness towards Universal Eye Health. We aimed to investigate the trends on number of cataract surgical procedures performed through the Brazilian national health system (SUS) from 2000 to 2019 while also evaluating costs associated with it. The Brazilian Public Health System Information Database (DATASUS) was used as the primary data source for procedures including extracapsular cataract extraction (ECCE) and phacoemulsification. Trends along the years were evaluated through generalized linear models. A total of 8,424,521 cataract procedures were performed from 2000 to 2019, with a significant increase along the years from 228,145 in 2000 to 663,186 in 2019 (p<0.001), a cataract surgical procedure rate change from 13.15 to 32.28 procedures per 10,000 people. It was observed a significant increase on the number of phacoemulsification (p<0.001) and a significant decrease on the number of ECCE (p<0.001). A shift on the predominant technique has occurred between 2007 and 2008 with phacoemulsification increasing its percentual representativity from 34.3% to 69.7% of all procedures, reaching 96.1% in 2019. Phacoemulsification costs per procedure increased 30.5% from from USD$119.00 to USD$155.33 (p = 0.007) and the ECCE costs per procedure increased 29.1% from USD$78.57 to USD$101.43 (p = 0.001). There is an increasing trend of procedures related to cataract treatment performed through SUS along the 20-years period and a switch on the technique predominance from ECCE to phacoemulsification was observed after 2007. The costs associated with both techniques have increased but have not followed the country's overall inflation. Data derived from DATASUS is important to understand the overall panorama of ocular health offered by the national health system and to provide information to guide healthcare leaders on management and planning of public health policies within the system.
RESUMO
BACKGROUND/AIMS: We analysed the ability of B-scan ultrasound, ocular electrophysiology testing and videoendoscopic examination for predicting visual prognosis in Boston Type 1 keratoprosthesis (KPro-1) candidates. Indirect anatomical and electrophysiological findings and results from direct endoscopic evaluations were correlated with postoperative functional data. METHODS: In this prospective and interventional study, we included 13 individuals who had previously been indicated for Kpro-1 surgery. All subjects underwent preoperative screening, including ophthalmic evaluation, B-scan ultrasound, electrophysiological testing, and perioperative intraocular videoendoscopic evaluation (VE). B-scan ultrasound, electrophysiological testing, and VE evaluation results were categorised as favourable or unfavourable predictors of postoperative functional results according to predefined criteria. The predictability values of B-scan ultrasound, electrophysiological testing, and VE prognostication were calculated based on the visual acuity level achieved. RESULTS: All surgeries and perioperative VEs were uneventful. Preoperative best-corrected visual acuity (BCVA) ranged from light perception to counting fingers. The 1-year postoperative BCVA was better than 20/200 (satisfactory visual acuity result) in 10 eyes (76.9%) and 20/40 or better in 5 eyes (38.5%). B-scan ultrasound presented a positive predictive value (PPV) of 85.7% for satisfactory postoperative visual acuity, electroretinography showed a PPV of 66.7%, and visual evoked potential presented a PPV of 66.7%. The perioperative VE PPV of a negative finding for satisfactory visual acuity was 100%. CONCLUSIONS: Fundoscopic visualisation by intraocular VE is a minimally invasive procedure that can be used to predict functional outcomes in keratoprosthesis candidates. This technique demonstrated better prognostication in keratoprosthesis candidates than B-scan ultrasound and electrophysiological testing.
Assuntos
Órgãos Artificiais , Doenças da Córnea , Córnea/diagnóstico por imagem , Córnea/cirurgia , Doenças da Córnea/diagnóstico , Doenças da Córnea/cirurgia , Eletrofisiologia , Potenciais Evocados Visuais , Humanos , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Próteses e Implantes , Implantação de Prótese/métodos , Estudos RetrospectivosRESUMO
Recently, it has been recommended that population-based studies report not only frequencies of vision impairment and blindness but also any ocular abnormalities that might lead an individual to seek for eyecare services. The current study aimed to determine prevalence of ocular findings regardless of visual acuity (VA) status in older adults from the Brazilian Amazon Region. Disturbances were grouped into: Eyelids; Anterior Segment; Posterior Segment; Increased intraocular pressure; and Overall Globe. The presence of an ocular finding was considered positive when any abnormality was noted, regardless of VA. Refractive errors were not considered. A total 2384 eligible persons were enumerated and 2041 (85.6%) examined. The prevalence of ocular disturbances in either eye was 87.0% and was associated with male gender, older age, lower education, and rural residence. Overall, main findings were pterygium, cataract, and pinguecula, occurring in 58.8%, 45.4% and 17.4%, respectively. Among individuals with 20/20 VA in both eyes, the most frequent findings were pterygium, pinguecula, and glaucoma cupping, occurring in 47.4%, 31.2% and 6.5%, respectively. The high prevalence of ocular findings observed in this population reinforces that different conditions might not immediately decrease VA but can indicate risk and/or discomfort symptoms and should be considered when planning public health ophthalmic services.
Assuntos
Oftalmopatias/epidemiologia , Avaliação Geriátrica/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Oftalmopatias/diagnóstico , Oftalmopatias/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância da População , Prevalência , Fatores de Risco , Acuidade VisualRESUMO
ABSTRACT Purpose: The Bayley Scales of Infant and Toddler Development-Third Edition (Bayley-III) is a tool for measuring the developmental status of children, including cognitive and motor functioning, in the first three years of life. This study aims to evaluate the correlation between grating visual acuity and visual functionality in healthy children using the Bayley-III. Methods: Binocular grating visual acuity was measured using Teller Acuity Cards followed by the Bayley-III in healthy children aged 1-42 months. Visual acuity (logMAR) and Bayley-III scores for both cognitive and motor (gross and fine) skills were compared. Results: Forty children (20 boys) aged 1.2-42.1 months were tested. Their mean visual acuity was 0.39 ± 0.27 logMAR, which was within the normal age limits for all children. There was a strong and significant negative correlation between visual acuity and age (r=-0.83, p<0.001). The mean cognitive raw data score was 49.92 ± 18.93 points, with a strong and significant positive correlation between cognitive score and age (r=0.81, p<0.001). The mean gross motor score was 41.72 ± 16.23 points, with a strong and significant positive correlation between gross motor score and age (r=0.75, p<0.001). The mean fine motor score was 39.75 ± 14.63 points, with a strong and significant positive correlation between fine motor score and age (r=0.77, p<0.001). Multiple linear regression demonstrated that older age and better visual acuity were significantly associated with higher Bayley-III scores. Conclusions: This study found a high correlation between grating visual acuity measured using Teller Acuity Cards and cognitive and motor scores measured using the Bayley-III in healthy children, demonstrating that the Bayley-III might be a useful tool for assessing the repercussions of visual impairment on the cognitive and motor development of young children.
RESUMO Objetivo: A Escala Bayley de Desenvolvimento Infantil (Bayley-III) é uma ferramenta que avalia o desenvolvimento de crianças nos 3 primeiros anos de vida, incluindo os domínios cognitivo e motor. Este estudo tem como objetivo correlacionar a acuidade visual de grades e a funcionalidade visual em crianças saudáveis usando a Bayley-III. Métodos: A acuidade visual binocular de grades foi medida usando o teste dos Cartões de Acuidade de Teller seguido pela Bayley-III em crianças saudáveis com idade entre 1-42 meses. Os escores da acuidade visual (logMAR) e da Bayley-III para habilidades cognitivas e motoras (grossa e fina) foram comparados. Resultados: Um grupo de 40 crianças (20 meninos) com idades entre 1,2-42,1 meses foi testado e a média da acuidade visual foi de 0,39 ± 0,27 logMAR, sendo que todas estavam dentro dos limites normais para a idade. Houve uma forte correlação negativa e significante entre acuidade visual e idade (r=-0,83; p<0,001). A média do escore cognitivo foi de 49,92 ± 18,93 pontos, com forte correlação positiva e significante entre o escore cognitivo e a idade (r=0,81; p<0,001). A média do escore motor grosso foi de 41,72 ± 16,23 pontos, com forte correlação positiva e significante entre o escore motor grosso e a idade (r=0,75; p<0,001). A média do escore motor fino foi de 39,75 ± 14,63 pontos, com uma forte correlação positiva e significante entre o escore motor fino e a idade (r=0,77; p<0,001). A regressão linear múltipla mostrou que maior idade e melhor acuidade visual foram significantemente associadas à escores cognitivo e motor mais altos. Conclusões: Neste estudo foi encontrada alta correlação entre a acuidade visual de grades medida pelos cartões de acuidade de Teller e os escores cogninitivo e motor medidos pela Bayley-III em crianças saudáveis. A Bayley-III pode ser uma ferramenta útil para avaliar a repercussão da deficiência visual no desenvolvimento cognitivo e motor de crianças.
RESUMO
PURPOSE: The Bayley Scales of Infant and Toddler Development-Third Edition (Bayley-III) is a tool for measuring the developmental status of children, including cognitive and motor functioning, in the first three years of life. This study aims to evaluate the correlation between grating visual acuity and visual functionality in healthy children using the Bayley-III. METHODS: Binocular grating visual acuity was measured using Teller Acuity Cards followed by the Bayley-III in healthy children aged 1-42 months. Visual acuity (logMAR) and Bayley-III scores for both cognitive and motor (gross and fine) skills were compared. RESULTS: Forty children (20 boys) aged 1.2-42.1 months were tested. Their mean visual acuity was 0.39 ± 0.27 logMAR, which was within the normal age limits for all children. There was a strong and significant negative correlation between visual acuity and age (r=-0.83, p<0.001). The mean cognitive raw data score was 49.92 ± 18.93 points, with a strong and significant positive correlation between cognitive score and age (r=0.81, p<0.001). The mean gross motor score was 41.72 ± 16.23 points, with a strong and significant positive correlation between gross motor score and age (r=0.75, p<0.001). The mean fine motor score was 39.75 ± 14.63 points, with a strong and significant positive correlation between fine motor score and age (r=0.77, p<0.001). Multiple linear regression demonstrated that older age and better visual acuity were significantly associated with higher Bayley-III scores. CONCLUSIONS: This study found a high correlation between grating visual acuity measured using Teller Acuity Cards and cognitive and motor scores measured using the Bayley-III in healthy children, demonstrating that the Bayley-III might be a useful tool for assessing the repercussions of visual impairment on the cognitive and motor development of young children.
Assuntos
Desenvolvimento Infantil , Destreza Motora , Idoso , Pré-Escolar , Cognição , Humanos , Lactente , Masculino , Acuidade VisualRESUMO
ABSTRACT Purpose: To determine visual impairment due to optic pathway tumors in children unable to perform recognition acuity tests. Methods: Grating visual acuity scores, in logMAR, were obtained by sweep visually evoked potentials (SVEP) in children with optic pathway tumors. The binocular grating visual acuity deficit was calculated by comparison with age-based norms and then assigned to categories of visual impairment as mild (from 0.10 to 0.39 logMAR), moderate (from 0.40 to 0.79 logMAR), or severe (≥0.80 logMAR). Interocular differences were calculated by subtraction and considered increased if >0.10 logMAR. Results: The participants were 25 children (13 boys; mean ± SD age, 35.1 ± 25.9 months; median age, 32.0 months) with optic pathway tumors (24 gliomas and 1 embryonal tumor), mostly located at the hypothalamic-chiasmatic transition (n=21; 84.0%) with visual abnormalities reported by parents (n=17; 68.0%). The mean grating acuity deficit was 0.60 ± 0.36 logMAR (median, 0.56 logMAR). Visual impairment was detected in all cases and was classified as mild in 10 (40.0%), moderate in 8 (32.0%), and severe in 7 (28.0%) children, along with increased interocular differences (>0.1 logMAR) (n=16; 64.0%). The remarkable ophthalmological abnormalities were nystagmus (n=17; 68.0%), optic disc cupping and/or pallor (n=13; 52.0%), strabismus (n=12; 48.0%), and poor visual behavior (n=9; 36.0%). Conclusion: In children with optic pathway tumors who were unable to perform recognition acuity tests, it was possible to quantify visual impairment by sweep-visually evoked potentials and to evaluate interocular differences in acuity. The severity of age-based grating visual acuity deficit and interocular differences was in accordance with ophthalmological abnormalities and neuroimaging results. Grating visual acuity deficit is useful for characterizing visual status in children with optic pathway tumors and for supporting neuro-oncologic management.(AU)
RESUMO Objetivo: Determinar o grau de deficiência visual em crianças com tumores da via óptica incapazes de informar a acuidade visual de reconhecimento. Método: A acuidade visual de grades, em logMAR, foi estimada por potenciais visuais evocados de varredura em crianças com tumores das vias ópticas. O déficit da acuidade visual de grades binocular foi calculado em relação ao valor mediano normativo esperado para a idade e a deficiência visual, classificada como leve (0,10 a 0,39 logMAR), moderada (0,40 a 0,79 logMAR) ou grave (≥0,80 logMAR). Diferenças inter-oculares foram calculadas por subtração e consideradas aumentadas se >0,10 logMAR. Resultados: Foram avaliadas 25 crianças (13 meninos; média de idade ± DP=35,1± 25,9 meses; mediana=32,0 meses) com tumores da via óptica (24 gliomas e 1 tumor embrionário) localizados particularmente na transição hipotalâmico-quiasmática (n=21; 84,0%) e com anormalidades visuais detectadas pelos pais (n=17; 68,0%). A média do déficit da acuidade de grades foi 0,60 ± 0,36 logMAR (mediana=0,56 logMAR). Observou-se deficiência visual leve em 10 (40,0%), moderada em 8 (32,0%) e grave em 7 (28,0%), além de aumento da diferença interocular da acuidade visual (n=16; 64,0%). As principais alterações oftalmológicas encontradas foram: nistagmo (n=17; 68,0%), aumento da escavação do disco óptico e/ou palidez (n=13; 52,0%), estrabismo (n=12; 48,0%) e comportamento visual pobre (n=9; 36,0%). Conclusão: Em crianças com tumor da via óptica e incapazes de responder aos testes de acuidade visual de reconhecimento, foi possível quantificar deficiência visual por meio dos potenciais visuais evocados de varredura e avaliar a diferença interocular da acuidade visual de grades. A gravidade do déficit da acuidade visual de grades relacionado à idade e a diferença interocular da acuidade visual de grades foram congruentes com alterações oftalmológicas e neuroimagem. O déficit da acuidade visual de grades foi útil à caracterização do estado visual em crianças com tumores da via óptica e ao embasamento da assistência neuro-oncológica.(AU)
Assuntos
Humanos , Criança , Vias Visuais/patologia , Acuidade Visual , Glioma do Nervo Óptico/patologia , Transtornos da Visão/etiologia , Potenciais Evocados VisuaisRESUMO
PURPOSE: To determine visual impairment due to optic pathway tumors in children unable to perform recognition acuity tests. METHODS: Grating visual acuity scores, in logMAR, were obtained by sweep visually evoked potentials (SVEP) in children with optic pathway tumors. The binocular grating visual acuity deficit was calculated by comparison with age-based norms and then assigned to categories of visual impairment as mild (from 0.10 to 0.39 logMAR), moderate (from 0.40 to 0.79 logMAR), or severe (≥0.80 logMAR). Interocular differences were calculated by subtraction and considered increased if >0.10 logMAR. RESULTS: The participants were 25 children (13 boys; mean ± SD age, 35.1 ± 25.9 months; median age, 32.0 months) with optic pathway tumors (24 gliomas and 1 embryonal tumor), mostly located at the hypothalamic-chiasmatic transition (n=21; 84.0%) with visual abnormalities reported by parents (n=17; 68.0%). The mean grating acuity deficit was 0.60 ± 0.36 logMAR (median, 0.56 logMAR). Visual impairment was detected in all cases and was classified as mild in 10 (40.0%), moderate in 8 (32.0%), and severe in 7 (28.0%) children, along with increased interocular differences (>0.1 logMAR) (n=16; 64.0%). The remarkable ophthalmological abnormalities were nystagmus (n=17; 68.0%), optic disc cupping and/or pallor (n=13; 52.0%), strabismus (n=12; 48.0%), and poor visual behavior (n=9; 36.0%). CONCLUSION: In children with optic pathway tumors who were unable to perform recognition acuity tests, it was possible to quantify visual impairment by sweep-visually evoked potentials and to evaluate interocular differences in acuity. The severity of age-based grating visual acuity deficit and interocular differences was in accordance with ophthalmological abnormalities and neuroimaging results. Grating visual acuity deficit is useful for characterizing visual status in children with optic pathway tumors and for supporting neuro-oncologic management.
Assuntos
Neoplasias , Baixa Visão , Adolescente , Adulto , Criança , Potenciais Evocados , Potenciais Evocados Visuais , Humanos , Masculino , Pessoa de Meia-Idade , Acuidade Visual , Adulto JovemRESUMO
PURPOSE: To determine normative values, intra- and inter-session variability for a range of parameters derived from the photopic negative response (PhNR) using a handheld mini-Ganzfeld stimulator in healthy normal adults. METHODS: Light-adapted flash full-field electroretinograms (ERGs) were recorded from healthy individuals with no visual complaints, visual acuity equal to or better than 0.0 logMAR (20/20 Snellen), and negative family history for visual diseases. ERGs were recorded from both eyes using a DTL® type fiber electrode after dilation of the pupils with instillation of 1 drop of tropicamide eye drops (1%). The full-field PhNR stimulus conditions were produced by a LED-based ColorBurst™ (Diagnosys LLC, Lowell, MA, USA) handheld stimulator. Red flashes of 1, 5 and 7 cd.s/m2 on a blue background of 10 cd/m2 were presented. A-wave, b-wave and PhNR amplitude (determined by both baseline to trough-BT and peak to trough-PT) and peak times were analyzed. Normal limits were determined as 5% percentile for amplitudes and 95% percentile for latencies. Intra- and inter-session variability were assessed with Wilcoxon signed-rank test, intraclass correlation coefficient (ICC) and the coefficient of variability (COV). RESULTS: Normative limits for PhNR amplitude (µV) using 1, 5 and 7 cd.s./m2 stimuli were, respectively: 20.81; 18.06 and 19.60 for BT and 69.11; 77.98; 76.51 for PT. Peak times (ms) normative limits for 1, 5 and 7 cd.s/m2 intensities were, respectively, 65.98; 78.20 and 77.96. Overall, intra-session variability assessed by coefficients of variation ranged from 1.35 to 10.28%. Inter-session variability disclosed significant intraclass correlation values for all PhNR parameters only for 1 cd.s/m2 stimuli. CONCLUSIONS: The normative values provided by this study are clinically helpful in the diagnosis of inner retinal disorders, especially those affecting retinal ganglion cells such as glaucoma and other optic neuropathies. Further studies, including a larger sample with variable age range would extend the validity of the current results.
Assuntos
Visão de Cores/fisiologia , Eletrorretinografia/métodos , Retina/fisiologia , Adolescente , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estimulação Luminosa , Valores de Referência , Células Ganglionares da Retina/fisiologia , Adulto JovemRESUMO
PURPOSE: The purpose of this study was to assess visual function by visually evoked potentials in adults with orbital and other primary brain tumors affecting the optic pathway. METHODS: In this retrospective case-control series, patients with orbital (intraconal and extraconal) or midline/chiasmatic tumors were included. Visually evoked potentials using pattern-reversal visually evoked potential and flash visually evoked potential stimuli were performed according to the international standards. Outcome measures were visually evoked potential parameters of amplitude (µV) and peak times (ms) measured both for the P100 component (pattern-reversal visually evoked potentials) and the N2P2 complex (flash visually evoked potential). Individual results were also compared with gender-based normative values. RESULTS: A group of 21 adult patients (17 females) and age- and sex-matched controls were evaluated. Tumor location was intraconal (6 meningiomas, 3 hemangiomas, 1 glioma), extraconal (6 meningiomas), and midline (3 pituitary adenomas, 2 hypothalamic/chiasmatic low-grade gliomas). Abnormal fundus (76%), abnormal pupillary reflexes (71%), reduced visual acuity (62%), strabismus (48%), and proptosis (38%) were present. Visually evoked potential abnormalities were found in at least one eye of all cases. Affected eyes had significantly reduced amplitudes and prolonged peak times for pattern-reversal visually evoked potentials (p < .001) and significantly reduced amplitudes for flash visually evoked potential (p < .001). In unilateral orbital tumors, abnormally prolonged pattern-reversal visually evoked potential peak times were also detected in some contralateral eyes (n = 6/16). CONCLUSION: Visually evoked potential abnormalities were found in all adult patients with orbital and other intracranial primary tumors, even in eyes with normal exam and good visual acuity. Visually evoked potential can be used as a non-invasive ancillary test to characterize and monitor visual function in subjects with these neoplastic lesions.
Assuntos
Neoplasias Encefálicas , Potenciais Evocados Visuais , Adulto , Potenciais Evocados , Feminino , Humanos , Estudos Retrospectivos , Visão OcularRESUMO
AIMS: To determine prevalence of pterygium, its role as main cause of unilateral and bilateral visual impairment and blindness and its impact on refractive errors from adults living in a high ultraviolet exposure area in the Brazilian Amazon Region. METHODS: Cluster sampling was used in randomly selecting subjects ≥45 years of age from urban and rural areas of Parintins city. Eligible subjects were enumerated through a door-to-door household survey and invited for an eye exam including refraction. Pterygium was assessed considering location (nasal, temporal or both) and size (<3 mm or ≥3 mm reaching or not pupillary margin). RESULTS: A total of 2384 persons were enumerated and 2041 (85.6%) were examined. Prevalence of pterygium was 58.8% (95% CI 53.8% to 63.7%) and associated with male gender (OR=1.63; 95% CI 1.37 to 1.94; p=0.001), while higher education was a protective factor (OR=0.63; 95% CI 0.44 to 0.92; p=0.018). Older age and rural residence were associated with pterygium ≥3 mm reaching or not pupillary margin, while higher education was a protective factor for pterygium ≥3 mm reaching pupillary margin. Prevalence of pterygium as cause of visual impairment and blindness was 14.3% and 3.9%, respectively. Significantly higher hyperopic refractive errors were found in eyes with pterygium ≥3 mm reaching or not pupillary margin. CONCLUSIONS: Pterygium was highly prevalent and the second cause of visual impairment and blindness after provision of refractive correction. Risk factors for pterygium were male gender, advanced age, lower education and rural residency. Strategies to provide pterygium early detection and proper management should be considered by healthcare authorities in this population.
Assuntos
Vigilância da População , Pterígio/epidemiologia , Erros de Refração/epidemiologia , População Rural , Acuidade Visual , Distribuição por Idade , Idoso , Brasil/epidemiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Pterígio/complicações , Erros de Refração/etiologia , Erros de Refração/fisiopatologiaRESUMO
Purpose: The photopic negative response (PhNR) is an electrophysiological method that provides retinal ganglion cell function assessment using full-field stimulation that does not require clear optics or refractive correction. The purpose of this study was to assess ganglion cell function by PhNR in affected and asymptomatic carriers from Brazilian families with LHON. Methods: Individuals either under suspicion or previously diagnosed with LHON and their family members were invited to participate in this cross-sectional study. Screening for the most frequent LHON mtDNA mutations was performed. Visual acuity, color discrimination, visual fields, pattern-reversal visual evoked potentials (PRVEP), full-field electroretinography and PhNR were tested. A control group of healthy subjects was included. Full-field ERG PhNR were recorded using red (640 nm) flashes at 1 cd.s/m2, on blue (470 nm) rod saturating background. PhNR amplitude (µV) was measured using baseline-to-trough (BT). Optical coherence tomography scans of both the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were measured. PhNR amplitudes among affected, carriers and controls were compared by Kruskal-Wallis test followed by post-hoc Dunn test. The associations between PhNR amplitude and OCT parameters were analyzed by Spearman rank correlation. Results: Participants were 24 LHON affected patients (23 males, mean age=30.5 ± 11.4 yrs) from 19 families with the following genotype: m.11778G>A [N = 15 (62%), 14 males]; m.14484T>C [N = 5 (21%), all males] and m.3460G>A [N = 4 (17%), all males] and 14 carriers [13 females, mean age: 43.2 ± 13.3 yrs; m.11778G>A (N = 11); m.3460G>A (N = 2) and m.14484T>C (N = 1)]. Controls were eight females and seven males (mean age: 32.6 ± 11.5 yrs). PhNR amplitudes were significantly reduced (p = 0.0001) in LHON affected (-5.96 ± 3.37 µV) compared to carriers (-16.53 ± 3.40 µV) and controls (-23.91 ± 4.83; p < 0.0001) and in carriers compared to controls (p = 0.01). A significant negative correlation was found between PhNR amplitude and total macular ganglion cell thickness (r = -0.62, p < 0.05). Severe abnormalities in color discrimination, visual fields and PRVEPs were found in affected and subclinical abnormalities in carriers. Conclusions: In this cohort of Brazilian families with LHON the photopic negative response was severely reduced in affected patients and mildly reduced in asymptomatic carriers suggesting possible subclinical abnormalities in the latter. These findings were similar among pathogenic mutations.
RESUMO
PURPOSE: To investigate cataract surgery prevalence, complications, visual outcomes, and coverage in a population of older adults from the Brazilian Amazon region. DESIGN: Population-based cross-sectional study. METHODS: Individuals ≥45 years of age from urban and rural areas of Parintins City, Brazil, were identified by cluster random sampling. Participants underwent ophthalmic examination, including uncorrected visual acuity, acuity with presenting correction (APC), and best-corrected visual acuity (BCVA) from each eye. In those with previous cataract surgery, surgical technique and complications including its contribution to vision impairment were noted. The association of surgical complications and surgical coverage with sociodemographic variables was assessed by multiple logistic regression. RESULTS: A total of 2,384 persons were determined to be eligible, and 2,041 (85.6%) were examined. Overall, prevalence of cataract surgery was 8.6%, with 11.3% urban and 5.0% rural. Surgical complications were associated with males, older age, and urban residency and were found in 60.4%, with posterior capsule opacification in 29.6% and posterior capsule rupture in 16.3%. Among the 270 eyes having cataract surgery, APC ≥20/32 was found in 44.4%, APC 20/40 to 20/63 in 20.8%, APC <20/63 to 20/200 in 14.4%, APC <20/200 to 20/400 in 2.6%, and APC <20/400 in 17.8%. Low surgical coverage was found with 57.9% of those with visual impairment due to cataract not being treated surgically. CONCLUSIONS: Although a reasonable prevalence of cataract surgery was found, a high complication rate, poor visual outcomes, and low cataract surgery coverage indicated that actions to improve quality and appropriate postsurgical management should be planned and implemented by public health authorities.
Assuntos
Extração de Catarata/estatística & dados numéricos , Complicações Pós-Operatórias , Transtornos da Visão/epidemiologia , Acuidade Visual/fisiologia , Idoso , Brasil/epidemiologia , Estudos Transversais , Feminino , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , População Rural/estatística & dados numéricos , População Urbana/estatística & dados numéricos , Transtornos da Visão/fisiopatologiaRESUMO
PURPOSE: To report a case of a child with strabismus and delayed discovery of a metallic intraocular foreign body with good recovery of visual acuity and stereopsis with 36-month follow-up. METHODS: A 4-year-old girl was evaluated due to exotropia of right eye initiated 9 months before with progressive worsening. Visual acuity was 1.00 logMAR (20/200) in the right eye and 0.00 logMAR (20/20) in the left eye. Anterior segment evidenced a small paracentral corneal leukoma, posterior synechia and mild lens opacity in the temporal quadrant only in the right eye. Fundus examination in the right eye identified the presence of an intraocular foreign body, with appearance of metallic components surrounded by retinal pigmented endothelial cells atrophy. Full-field electroretinography (ERG) showed reduced amplitudes and delayed implicit times for both rods and cones in the affected eye. All tests were normal in the fellow eye. RESULTS: Pars plana vitrectomy was promptly performed in the right eye, followed by phacoemulsification with intraocular lens implantation 4 months later due to worsening of the lens opacification. The full-field ERG was repeated after the surgical procedures. The ERG showed mild worsening of all responses in the right eye. After 36 months of follow-up, visual acuity was 0.20 logMAR (20/32) with improvement of the ocular misalignment and with 60 s of arc stereopsis with ERG responses unchanged. CONCLUSION: In this young girl perforating ocular trauma with metallic material was lately diagnosed with strabismus as a sign of alert. Prompt surgical intervention and proper management were essential to provide reasonable visual function including some degree of stereopsis, even though retinal dysfunction characterized by ERG was persistent.
Assuntos
Corpos Estranhos no Olho/diagnóstico , Ferimentos Oculares Penetrantes/diagnóstico , Metais , Retina/lesões , Atrofia , Pré-Escolar , Diagnóstico Tardio , Percepção de Profundidade/fisiologia , Eletrorretinografia , Exotropia/diagnóstico , Corpos Estranhos no Olho/fisiopatologia , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/fisiopatologia , Ferimentos Oculares Penetrantes/cirurgia , Feminino , Humanos , Implante de Lente Intraocular , Facoemulsificação , Refração Ocular/fisiologia , Retina/fisiopatologia , Epitélio Pigmentado da Retina/patologia , Acuidade Visual/fisiologia , VitrectomiaRESUMO
Purpose: To determine the prevalence and causes of visual impairment and blindness in adults aged 45 years and older from Parintins, Brazilian Amazon Region. Methods: A random cluster sampling method was used to identify subjects 45 years of age and older from urban and rural census sectors of Parintins city, Amazonas State, from March 2014 to May 2015. Participants underwent a detailed ocular examination, including presenting (PVA) and best corrected visual acuity (BCVA). The main cause of PVA<20/32 per eye was determined. Results: A total of 2384 subjects were enumerated and 2041 (85.6%) examined. The prevalence of presenting mild visual impairment - MiVI (<20/32 - ≥20/63) in the better-seeing eye was 17.0% [95% CI: 15.3-18.7%], and 8.5% [95% CI: 7.3-9.7%] with best correction. The prevalence of presenting moderate visual impairment - MVI (<20/63 - ≥20/200) was 18.4% [95% CI: 16.2-20.6%], and 6.9% [95% CI: 5.8-8.0%] with best correction. The prevalence of presenting bilateral VA <20/200 was 4.3% [95% CI: 3.6-5.0%], and 3.3% [95% CI: 2.5-4.0%] with best correction and increased with older age. Cataract (47.8%) and glaucoma (7.5%) were its main causes. In less severely affected eyes, uncorrected refractive errors (MVI: 42.6%; MiVI: 79.0%), cataract (MVI: 40.6%; MiVI: 13.7%) and pterygium (MVI: 7.6%; MiVI: 2.7%) were the main causes. Conclusions: Most cases of visual impairment in Parintins are either preventable or treatable, and public health initiatives should target cataract surgical services and refraction with spectacle provision.