Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Z Med Phys ; 30(2): 155-165, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31980303

RESUMO

PURPOSE: This multi-institutional study investigates whether computational verification of fluence-modulated treatment plans using independent software with its own Strahlerkopfmodel is an appropriate method for patient-related quality assurance (PRQA) in the context of various combinations of linear accelerators (linacs), treatment techniques and treatment planning systems (TPS). MATERIALS AND METHODS: The PRQA-software's (Mobius3D) recalculations of 9 institutions' treatment plans were analyzed for a horseshoe-shaped planning target volume (PTV) inside a phantom. The recomputed dose distributions were compared to a) the dose distributions as calculated by all TPS's and b) the measured dose distributions, which were acquired using the same independent measuring system for all institutions. Furthermore, dose volume histograms were examined. The penumbra deviations and mean gamma values were quantified using Verisoft (PTW). Additionally, workflow requirements for computational verification were discussed. RESULTS: Mobius3D is compatible with all examined TPSs, treatment techniques and linacs. The mean PTV dose differences (Mobius3D-TPS, <3.0%) and 3D gamma passing rates (>95.0%) led to a positive plan acceptance result in all cases. These results are similar to the outcome of the dosimetric measurements with one exception. The mean gamma values (<0.5) show a good agreement between Mobius3D and the TPS dose distributions. CONCLUSION: Using Mobius3D was proven to be an appropriate computational PRQA method for the tested combinations of linacs, treatment techniques and TPS's. The clinical use of Mobius3D has to be complemented with regular dosimetric measurements and thorough linac and TPS QA. Mobius3D's computational verification reduced measurement effort and personnel needs in comparison to dosimetric verifications.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica
2.
Int Health ; 11(2): 93-100, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30388277

RESUMO

BACKGROUND: Acute HIV infection (AHI) is the phase of HIV infection immediately after acquisition, during which many patients develop symptoms and often seek healthcare. However, clinicians in sub-Saharan Africa are not currently taught about AHI. METHODS: This study pilot-tested a self-directed AHI training module among clinical officers (COs) in coastal Kenya and assessed knowledge gained and challenges to instituting screening. The training module included four domains: AHI definition and importance of AHI recognition; symptoms and screening algorithms; diagnostic strategies; and management. AHI knowledge was assessed before and immediately after training. Participants' ability to utilize an AHI screening algorithm was evaluated with a case-based exercise. RESULTS: Self-directed training was completed by 45 COs. Pre-test scores were low (median score 35% IQR 30-45%), but improved significantly after training (median post-test score 75%, IQR 70-85%, Wilcoxon signed-rank test p<0.0001). Participants had challenges in understanding the utility and application of a screening algorithm to identify patients for whom AHI testing would be indicated. Knowledge of AHI was poor at baseline, but improved with self-directed learning. Based on these findings, we revised and improved the AHI training module and pre- and post-assessments, which are now freely available online at www.marps-africa.org. CONCLUSIONS: Guidelines on AHI screening and diagnosis are urgently needed in high HIV transmission areas.


Assuntos
Educação a Distância , Infecções por HIV/diagnóstico , Programas de Rastreamento , Médicos de Atenção Primária/educação , Doença Aguda , Adolescente , Adulto , Algoritmos , Assistência Ambulatorial/estatística & dados numéricos , Competência Clínica/estatística & dados numéricos , Feminino , Humanos , Quênia , Masculino , Aceitação pelo Paciente de Cuidados de Saúde , Médicos de Atenção Primária/estatística & dados numéricos , Projetos Piloto , Adulto Jovem
3.
Strahlenther Onkol ; 193(1): 46-54, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27812732

RESUMO

PURPOSE: This project compares the different patient-related quality assurance systems for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques currently used in the central Germany area with an independent measuring system. MATERIALS AND METHODS: The participating institutions generated 21 treatment plans with different combinations of treatment planning systems (TPS) and linear accelerators (LINAC) for the QUASIMODO (Quality ASsurance of Intensity MODulated radiation Oncology) patient model. The plans were exposed to the ArcCHECK measuring system (Sun Nuclear Corporation, Melbourne, FL, USA). The dose distributions were analyzed using the corresponding software and a point dose measured at the isocenter with an ionization chamber. RESULTS: According to the generally used criteria of a 10 % threshold, 3 % difference, and 3 mm distance, the majority of plans investigated showed a gamma index exceeding 95 %. Only one plan did not fulfill the criteria and three of the plans did not comply with the commonly accepted tolerance level of ±3 % in point dose measurement. CONCLUSION: Using only one of the two examined methods for patient-related quality assurance is not sufficiently significant in all cases.


Assuntos
Neoplasias/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/normas , Análise de Falha de Equipamento , Alemanha , Fidelidade a Diretrizes/normas , Humanos , Assistência Centrada no Paciente/normas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Org Biomol Chem ; 11(22): 3674-91, 2013 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-23615777

RESUMO

4-Phenol diazonium salts undergo Pd-catalyzed Heck reactions with various styrenes to 4'-hydroxy stilbenes. In almost all cases higher yields and fewer side products were observed, compared to the analogous 4-methoxy benzene diazonium salts. In contrast, the reaction fails completely with 2- and 3-phenol diazonium salts. For these substitution patterns the methoxy-substituted derivatives are superior.


Assuntos
Compostos de Diazônio/química , Fenóis/síntese química , Sais/química , Estilbenos/síntese química , Estirenos/química , Catálise , Paládio/química , Fenóis/química , Estilbenos/química
5.
Chemistry ; 17(25): 7032-40, 2011 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-21557361

RESUMO

Alkynes and phenol diazonium salts undergo a Pd-catalyzed [2+2+1] cyclization reaction to spiro[4,5]decatetraene-7-ones. This structure was confirmed for one example by X-ray single-crystal structure analysis. The reaction is believed to proceed through oxidative addition of the phenol diazonium cation to Pd(0), subsequent insertion of two alkynes, followed by irreversible spirocyclization.

6.
Org Biomol Chem ; 8(6): 1406-14, 2010 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-20204215

RESUMO

Arene diazonium tetrafluoroborates can be synthesized from aromatic acetamides via a sequence of deacetylation, diazotation and precipitation, induced by anion exchange. The reaction is conducted as a convenient one-flask transformation with consecutive addition of the appropriate reagents. Exchange of solvents or removal of byproducts prior to isolation of the product is not required. The arene diazonium salts are isolated from the reaction mixture by simple filtration. Two complementary protocols are presented, and the utility of the reaction is exemplified for a synthesis of the diarylheptanoid natural product de-O-methyl centrolobine.


Assuntos
Acetaminofen/química , Boratos/química , Compostos de Diazônio/síntese química , Acetilação , Produtos Biológicos/síntese química , Produtos Biológicos/química , Compostos de Diazônio/química , Piranos/síntese química , Piranos/química , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...