Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Pollut ; 157(12): 3465-70, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19683375

RESUMO

Activated carbon (AC) strongly sorbs organic pollutants and can be used for remediation of soils and sediments. A method for AC quantification is essential to monitor AC (re)distribution. Since AC is black carbon (BC), two methods for BC quantification were tested for AC mixed in different soils and sediments: i) chemothermal oxidation (CTO) at a range of temperatures and ii) wet-chemical oxidation with a potassium dichromate/sulfuric acid solution. For three soils, the amount of AC was accurately determined by CTO at 375 degrees C. For two sediments, however, much of the AC disappeared during combustion at 375 degrees C, which could probably be explained by catalytic effects by sediment constituents. CTO at lower temperatures (325-350 degrees C) was a feasible alternative for one of the sediments. Wet oxidation effectively functioned for AC quantification in sediments, with almost complete AC recovery (81-92%) and low remaining amounts of native organic carbon (5-16%).


Assuntos
Carvão Vegetal/química , Técnicas de Química Analítica/métodos , Recuperação e Remediação Ambiental/instrumentação , Sedimentos Geológicos/química , Solo/química , Adsorção , Temperatura Alta , Oxirredução