Biomed Microdevices ; 7(3): 197-204, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16133807

RESUMO

A measurement concept has been realized for the detection of carbon dioxide, where the CO(2) induced pressure generation by an enclosed pH-sensitive hydrogel is measured with a micro pressure sensor. The application of the sensor is the quantification of the partial pressure of CO(2) (Pco(2)) in the stomach as diagnosis for gastrointestinal ischemia. The principle is put to the proof by examining the sensor response to changes in Pco(2). Furthermore, the response time, temperature-sensitivity and resolution are determined. The sensor responds well to changes in Pco(2) with a maximum pressure generation of 0.29 x 10(5) Pa at 20 kPa CO(2). The 90% response time varies between 1.5 and 4.5 minutes at 37( composite function)C. The sensor shows a linear temperature-sensitivity which can easily be compensated for, and enables detection of Pco(2) changes as small as 0.5 kPa CO(2).


Assuntos
Bioensaio/instrumentação , Dióxido de Carbono/análise , Dióxido de Carbono/química , Hidrogéis/química , Eletrodos Seletivos de Íons , Microeletrodos , Transdutores de Pressão , Bioensaio/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Concentração de Íons de Hidrogênio , Miniaturização/métodos , Pressão Osmótica
2.
J Chem Phys ; 121(6): 2746-51, 2004 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-15281877

RESUMO

A method is proposed to study the behavior of stimulus-sensitive hydrogels under isochoric conditions. Freedom of swell movement of such a hydrogel was restricted in all directions by enclosing the hydrogel between a micropressure sensor and a porous cover. Water and external stimuli can be applied to the hydrogel through the pores of the cover to provoke swelling, which results in pressure generation measured by the pressure sensor. The method was put to the proof by examining the response of a pH-sensitive hydrogel to changes in pH, ionic strength, and buffer concentrations of the surrounding solution. Both equilibrium and dynamic pressure generation were observed. The results show that higher pressures are obtained by incorporating more ionizable groups into the hydrogel network or by lowering the ionic strength of the external solution. Furthermore it was proven that pressures reach equilibrium faster when less titratable groups are incorporated or at the presence of higher buffer concentrations in the surrounding solution. By using microfabrication techniques the dimensions of the hydrogel could be kept small with the advantage that responses are fast. A DMAEMA-co-HEMA hydrogel with 2.5% protonable groups and a thickness of 15 microm generated a Delta pressure of 0.67 x 10(5) Pa in 12 min when a pH step from 9 to 6 was applied. The presented method is a simple and fast manner to characterize the static and dynamic stimulus-dependent behavior of hydrogels.


Assuntos
Físico-Química/instrumentação , Cristalização/instrumentação , Hidrogéis/química , Micromanipulação/métodos , Modelos Químicos , Modelos Moleculares , Transdutores , Físico-Química/métodos , Simulação por Computador , Cristalização/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Hidrogéis/análise , Hidrogéis/síntese química , Miniaturização , Peso Molecular , Pressão
3.
Analyst ; 128(8): 1062-6, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12964608

RESUMO

In this paper, glucose is potentiometrically measured by using a specific field effect transistor, the EMOSFET. In this device, glucose oxidase is immobilized within a bovine serum albumin matrix, using glutaraldehyde. This layer is deposited on the top of an electroactive Os-polyvinylpyridine layer containing horseradish peroxidase, which is used as the gate material of the FET. The basic principle of the sensor is to measure the glucose concentration by means of measuring the change in the work function of the electroactive gate due to its redox reaction with the H2O2, generated by the reaction between glucose and glucose oxidase. The change in the work function can be detected as a change in the threshold voltage of the FET. Moreover, a measuring mode called "constant current potentiometry" has been applied to improve the sensitivity of the sensor. The sensitivity of the sensor working in this mode is found to be much higher than the Nernstian value. The experimental results show that the detection limit of the sensor can be tuned depending on the value of the applied current and the glucose oxidase concentration in the gate.


Assuntos
Técnicas Biossensoriais , Glucose/análise , Glucose Oxidase/química , Potenciometria/métodos , Sensibilidade e Especificidade
4.
Biosens Bioelectron ; 18(9): 1109-14, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12788553

RESUMO

The so-called ion-step method is a novel potentiometric approach that can detect protein adsorbed onto the gate area of modified ion-sensitive field-effect transistors (ISFETs). In this report, a generic technology is described for immobilization of peptides and proteins to the ISFET gate in order to confer specific binding properties to the ISFET. For this, the surface of the ISFET was covered with a monolayer of Amino beads (diameter, 0.9 microm) followed by immobilization of protein ligands onto these beads. Amino beads are latex spheres that contain primary amino groups at the outer surface. Preactivation of the latex-bound amino groups with glutaraldehyde, and consecutive incubation with polylysine resulted in covalent immobilization of this polyamine, as revealed by ion stepping measurements. For ImmunoFET applications, human serum albumin (HSA) was immobilized onto the Amino bead-covered ISFETs, by passive adsorption but also by covalent coupling. Resulting devices were used for qualitative detection of alpha-HSA antibodies by means of the ion step method. The binding of antibody was very specific and fast (most of the binding was accomplished in 15 min) with signal yields up to 17 mV. Efforts to increase the antibody-binding capacity of the solid phase on the ISFET exploiting amino group activation (with glutaraldehyde or other homobifunctional cross linkers) before HSA coupling, did not improve signal yield. The bead technology described in this report is an easy, generic method for coating the ISFET with a solid phase that, using the ion-step method, can be applied to immunosensing.


Assuntos
Anticorpos/análise , Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/química , Eletroquímica/instrumentação , Imunoensaio/métodos , Microesferas , Albumina Sérica/análise , Albumina Sérica/química , Animais , Anticorpos/imunologia , Complexo Antígeno-Anticorpo/análise , Complexo Antígeno-Anticorpo/imunologia , Técnicas Biossensoriais/instrumentação , Eletroquímica/métodos , Imunoensaio/instrumentação , Proteínas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Albumina Sérica/imunologia , Transistores Eletrônicos
5.
Arch Physiol Biochem ; 111(4): 369-76, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15764077

RESUMO

Human living skin generates an increase in the skin potential when compressed. This was measured on eight subjects with a matrix of nine Ag/AgCl electrodes. The potential increased with the pressure until it reached a maximum. When the pressure was increased stepwise, the response showed an overshoot at each step. Human cadaver skin did not show these potential increments. Neither did pads of collagen, paper tissue soaked in a KCl solution, nor layers of cultured keratinocytes. Three theories are described that may explain the origin of the measured skin potentials. The first is based on the piezoelectric characteristics of proteins in the skin. The second theory assumes that the skin is a charged membrane which generates a streaming potential when deformed. A third theory is proposed in which deformation of absorbed charged protein layers on structures in the skin change the alignment of Donnan potentials in the surrounding tissue.


Assuntos
Colágeno/fisiologia , Queratinócitos/fisiologia , Potenciais da Membrana/fisiologia , Fenômenos Fisiológicos da Pele , Eletrodos , Humanos , Fatores de Tempo
6.
Biol Cybern ; 85(4): 281-91, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11592625

RESUMO

The influence of subthreshold depolarizing prepulses on the threshold current-to-distance and the threshold current-to-diameter relationship of myelinated nerve fibers has been investigated. A nerve fiber model was used in combination with both a simple, homogeneous volume conductor model with a point source and a realistic, inhomogeneous volume conductor model of a monofascicular nerve trunk surrounded by a cuff electrode. The models predict that a subthreshold depolarizing prepulse will desensitize Ranvier nodes of fibers in the vicinity of the cathode and thus cause an increase in the threshold current of a subsequent pulse to activate these fibers. If the increase in threshold current of the excited node is large enough, the excitation will be accompanied by a strong hyperpolarization of adjacent nodes, preventing the propagation of action potentials in these fibers. As fibers close to the electrode are more desensitized by prepulses than more distant ones, it is possible to stimulate distant fibers without stimulating such fibers close to the electrode. Moreover, as larger fibers are more desensitized than smaller ones, smaller fibers have lower threshold currents than larger fibers up to a certain distance from the electrode. The realistic model has provided an additional condition for the application of this method to invert nerve fiber recruitment, i.e., real or virtual anodes should be close to the cathode. When using a cuff electrode for this purpose, in the case of monopolar stimulation the cuff length (determining the position of the virtual anodes) should not exceed twice the internodal length of the fibers to be blocked. Similarly, the distance between cathode and anodes should not exceed the internodal length of these fibers when stimulation is to be applied tripolarly.


Assuntos
Modelos Neurológicos , Terminações Nervosas/fisiologia , Animais , Eletrodos , Potenciais da Membrana
7.
Biosens Bioelectron ; 16(6): 391-7, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11672653

RESUMO

A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 microm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few microl of an appropriate enzyme solution, an amperometric enzyme sensor results. As the dialysis tubing is impermeable for large molecular species such as enzymes, this approach does not require any immobilization chemistry, and as a consequence the enzyme is present in its natural free form. Based on this principle, amperometric sensors for lactate, glucose, and glutamate were formed by filling cavities, precision machined in Perspex, with buffered solutions containing respectively, lactate-, glucose-, and glutamate-oxidase. All sensors showed a large linear range (0-35 mM for glucose, 0-3 mM for lactate, and 0-5 mM for glutamate) covering the complete physiological range. The lower detection limit was in the order of 15-50 microM. Applicability in flow injection analysis systems is demonstrated.


Assuntos
Técnicas Biossensoriais/métodos , Soluções para Diálise/química , Glucose Oxidase/química , Glucose/análise , Ácido Láctico/análise , Eletroquímica , Eletrodos , Enzimas/química , Análise de Injeção de Fluxo/métodos , Ácido Glutâmico/análise , Oxigenases de Função Mista/química
8.
Arch Physiol Biochem ; 108(4): 349-59, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11094386

RESUMO

The recruitment characteristics of muscle selective nerve stimulation by a multi-contact nerve cuff electrode, as predicted by computer modeling, have been investigated in acute experiments on rabbits. A nerve cuff containing five or six dot electrodes was placed around the sciatic nerve in five rabbits. M-waves were recorded with wire electrodes from the lateral gastrocnemius, soleus, tibialis anterior, and extensor digitorum longus muscles. The muscle recruitment performances of three contact configurations (monopole, transverse bipole, transverse tripole) were compared. The selectivity was quantified by the recruitment of two muscles (one extensor and one flexor) in response to a particular stimulus. The results showed that only in a few cases, transverse bi- and tripolar stimulation provided a better selectivity than monopolar stimulation. Neither of the two extensors, nor of the two flexors could be stimulated separately. In accordance with the results of the modeling studies, bi- and tripolar stimulation required higher stimulus currents than monopolar stimulation, whereas maximum recruitment and slopes of recruitment curves were lower. The rabbit sciatic nerve appears to be a less suitable preparation for reproducible selectivity experiments, due to the variability in the number and size of the fascicles and their position in this nerve.


Assuntos
Estimulação Elétrica/instrumentação , Eletrodos , Neurofisiologia/instrumentação , Nervo Isquiático/fisiologia , Animais , Desenho de Equipamento , Masculino , Modelos Neurológicos , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Coelhos , Reprodutibilidade dos Testes , Nervo Isquiático/ultraestrutura
9.
Biomed Microdevices ; 1(2): 121-30, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-16281112

RESUMO

In this paper a micromachined electrochemically driven pump capable of dosing precise nanoliter amounts of liquid is presented. The pump consists of a micromachined channel structure realized in silicon by reactive ion etching. On top of this structure a Pyrex((R)) cover piece with noble metal electrodes was bonded. The fluid to be dispensed is stored in a meander shaped reservoir which is part of the channel structure. This meander starts in an electrolyte solution containing reservoir, on top of which two noble metal electrodes are positioned. By the electrochemical production of gas bubbles by electrolysis of water at these electrodes, liquid can be driven out of the meander. The measured volume displacements were in close agreement with theory. Pump rates as low as a few nl/s could accurately be controlled via the actuation current through the electrodes. By applying current pulses rather than a continuous current, preset amounts of fluid in the nanoliter range could be dosed successfully. Because the resulting device consists of simple channel structures and metal electrodes it can easily be integrated in miniaturized chemical analysis systems to dose reagents or calibration solutions.

10.
J Colloid Interface Sci ; 187(1): 148-58, 1997 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-9245324

RESUMO

A new measuring method is described for obtaining a proton titration curve. The curve is obtained from a microporous composite membrane, consisting of polystyrene beads in an agarose matrix, with lysozyme molecules adsorbed to the bead surface. The membrane is incorporated into a sensor system by deposition on a silicon chip with a pH-sensitive ion-sensitive field effect transistor (ISFET) located in the middle of a Ag/AgCl electrode. The actual measurement is performed by creating a stepwise change in the salt concentration of the bathing electrolyte (the ion step) and measuring the ISFET potential versus the Ag/AgCl electrode. This potential shows a transient change in the ion step, which indicates a transient pH change in the membrane. This procedure is repeated at a series of pH values. Equations are presented to calculate the proton titration curve of the membrane from the amplitude and duration of the measured transients. Measurements show qualitative agreement between the curves obtained and equilibrium titration experiments on the same system.

11.
Biosens Bioelectron ; 10(3-4): 269-82, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7755959

RESUMO

The ion-step measuring method was used to determine absolute heparin concentrations in PBS and blood plasma with a Ta2O5 ISFET on to which a monolayer of protamine had been immobilized. Heparin is a highly negatively charged polysaccharide, which is used clinically to delay the clotting of blood. Protamine acts as an affinity ligand for heparin. The response of the ISFET system on a step-wise increase in the electrolyte concentration (a so-called ion-step) is a transient change of the output voltage, which is related to the surface charge density of the ISFET gate oxide. After 2 mins of incubation in a plasma sample containing heparin, the amplitude of the transient ISFET response to an ion-step showed a linear relation to the heparin concentration. In blood plasma, heparin concentrations between 0.3 and 2.0 Units/ml could be determined with an accuracy of +/- 0.08 Units/ml. Heparin concentrations in different plasma samples of heparinized patients were determined and compared with the APTT. No direct relation was found between the APTT and the heparin concentration, but this result was not surprising.


Assuntos
Técnicas Biossensoriais , Heparina/análise , Protaminas/química
12.
J Acoust Soc Am ; 91(4 Pt 1): 2261-9, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1597614

RESUMO

A theoretical noise analysis of the combination of a capacitive microphone and a preamplifier containing a metal-oxide-semiconductor field-effect transistor (MOSFET) and a high-value resistive bias element is given. It is found that the output signal-to-noise ratio for a source follower and for a common-source circuit is almost the same. It is also shown that the output noise can be reduced by making the microphone capacitance as well as the bias resistor as large as possible, and furthermore by keeping the parasitic gate capacitances as low as possible and finally by using an optimum value for the gate area of the MOSFET. The main noise source is the thermal noise of the gate leakage resistance of the MOSFET. It is also shown that short-channel MOSFETs produce more thermal channel noise than longer channel devices.


Assuntos
Amplificadores Eletrônicos , Auxiliares de Audição , Semicondutores , Transistores Eletrônicos , Desenho de Equipamento , Humanos , Modelos Teóricos , Espectrografia do Som
13.
IEEE Trans Biomed Eng ; 39(2): 122-34, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1612615

RESUMO

A realistic, quantitative model is presented for the excitation of myelinated nerve fibers by intrafascicular electrodes. It predicts the stimulatory regions of any configuration of any number of electrodes, positioned anywhere inside the fascicle. The model has two parts. First, the nerve fiber is represented by a lumped electrical network and its response to an arbitrary extracellular potential field is calculated. Second, assuming a cylindrical geometry of the nerve bundle and its surroundings, an analytical expression for this field is derived. With realistic parameters, the model is applied to two cases: monopolar stimulation by a single cathode and stimulation by a specific tripolar configuration. It is shown that tripolar stimulation has the better spatial selectivity. Also tripolar stimulation is less sensitive to the conductivity of the medium surrounding the nerve and yields a more natural recruitment order.


Assuntos
Estimulação Elétrica , Eletrodos Implantados , Modelos Neurológicos , Fibras Nervosas Mielinizadas/fisiologia , Condutividade Elétrica , Desenho de Equipamento , Potenciais Evocados/fisiologia , Humanos , Potenciais da Membrana/fisiologia , Condução Nervosa/fisiologia , Propriedades de Superfície
14.
IEEE Trans Biomed Eng ; 38(4): 353-6, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1855797

RESUMO

A transistor pH electrode (ion sensitive field effect transistor), placed in the upper dentures of eleven xerostomia patients and five healthy volunteers, was used to register pH changes in five-, six- and seven-day-old dental plaque. A mouth rinse with a 10% sucrose solution caused a pH fall of about three decades. A significant difference in duration of critical plaque pH was observed: in xerostomia patients, a 10% longer period of pH less than 5.7 was registered during 60 min following a sucrose rinse. Normal oral functions were not influenced by the denture with an integrated electrode. This method is usable for plaque pH registration in xerostomia patients.


Assuntos
Placa Dentária/metabolismo , Xerostomia/metabolismo , Calibragem , Dentaduras , Eletrodos , Humanos , Concentração de Íons de Hidrogênio
15.
Biosens Bioelectron ; 6(1): 55-72, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-2049171

RESUMO

During the last decennia many protein-related electrical phenomena have been studied and applied in a variety of measuring systems, from simple metal electrodes with adsorbed proteins to sophisticated systems with lipid bilayers. Many of the investigations concern the monitoring of immuno reactions. The basic underlying electrical effects of the observed phenomena are the protein modulated dielectric constant, conductivity, electrical potential, ion permeability and ion mobility. In this paper special attention is paid to the capacitive measurements with EIS systems as well as impedance and potential measurements with FET devices. The Donnan theory is treated and applied to the static ImmunoFET operation, explaining the relatively small effects which have been reported. Finally, an alternative approach is described in which the ImmunoFET is applied in a dynamic way, to circumvent the drawbacks of the static measurements.


Assuntos
Eletroquímica/métodos , Proteínas/análise , Sequência de Aminoácidos , Condutividade Elétrica , Eletrodos , Bicamadas Lipídicas , Potenciais da Membrana/fisiologia , Dados de Sequência Molecular
16.
Biosens Bioelectron ; 5(2): 103-24, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2331349

RESUMO

A new method is presented for the detection of an immunological reaction taking place in a membrane, which covers the gate area of an ISFET. By stepwise changing the electrolyte concentration of the sample solution, a transient diffusion of ions through the membrane-protein layer occurs, resulting in a transient membrane potential, which is measured by the ISFET. The diffusion rate is determined by the immobile charge density in the amphoteric protein layer, which changes upon formation of antibody-antigen complexes. No membrane potential is induced at zero fixed charge density as occurs at a protein characteristic pH. Isoelectric points of embedded proteins can be determined by detecting the zero potential response. Up to now, the authors have studied the membrane adsorption of lysozyme, human serum albumin (HSA) and the immune reaction of HSA with the antibody anti-human serum albumin (alpha HSA). The influence of protein parameters on the amplitude of the transient can be described with an empirical equation. Assuming Langmuir behaviour, the protein concentration in the solution can well be correlated with the concentration in the membrane. This new detection method is unique concerning direct measurements of charge densities and isoelectric points of amphoteric macromolecules adsorbed in the membrane. The simple procedure of one incubation stage followed by one detection stage, without separate washing and labelling techniques, gives direct information about specific charge properties of the macromolecules to be studied.


Assuntos
Técnicas Biossensoriais , Imunoensaio/métodos , Proteínas/análise , Reações Antígeno-Anticorpo , Concentração de Íons de Hidrogênio , Potenciais da Membrana , Modelos Teóricos , Muramidase , Proteínas/imunologia , Albumina Sérica
17.
Biosensors ; 3(3): 161-86, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3447596

RESUMO

This paper reviews the results that have been reported on ISFET based enzyme sensors. The most important improvement that results from the application of ISFETs instead of glass membrane electrodes is in the method of fabrication. Problems with regard to the pH dependence of the response and the dynamic range as well as the influence of the sample buffer capacity have not been solved. As a possible solution we introduce a coulometric system that compensates for the analyte buffer capacity. If the pH in the immobilized enzyme layer is thus controlled, the resulting pH-static enzyme sensor has an output that is independent of the sample pH and buffer capacity and has an expanded linear range.


Assuntos
Eletrodos , Enzimas Imobilizadas , Biotecnologia , Concentração de Íons de Hidrogênio
19.
Biosensors ; 2(1): 15-33, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3790175

RESUMO

After having considered the general definition of biosensors, the specifications of one type are discussed here in more detail, namely the pH-sensitive ISFET, which is at present being clinically investigated for intravascular blood pH recording. Results, advantages and possible improvements will be discussed, as well as a prediction with respect to future developments of FET-based biosensors.


Assuntos
Produtos Biológicos , Sangue , Cateterismo , Humanos , Concentração de Íons de Hidrogênio , Cinética , Métodos