Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Chromatogr A ; 1706: 464284, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37572537

RESUMO

A simple and highly efficient ultrasound assisted membrane-assisted solvent extraction (MASE) pre-treatment method for urine has been developed and validated for the simultaneous determination of twenty-two drugs involved in drug-facilitated sexual assaults (DFSAs) by liquid chromatography-tandem mass spectrometry. MASE was performed with 4.0 mL of urine (pH adjusted at 12), 400 µL of hexane as an organic solvent inside the polypropylene membrane, and ultrasonication (45 kHz, 120 W) for 10 min. A pre-concentration factor of 40 was achieved after evaporation (N2 stream) and re-dissolution in 100 µL of methanol. Analytes were separated using a Zorbax Eclipse Plus C18 column under gradient elution with aqueous 10 mM NH4HCO3 (pH 8.0) and methanol as mobile phases. Matrix-matched calibrations allowed the assessment of DFSA drugs of quite different octanol-water partition coefficients (Ko/w), from 1.32 101 for pregabalin to 2.45 105 for clomipramine (Log P values from 1.12 (pregabalin) to 5.39 (clomipramine)). The limit of detection (LOD) was between 0.0075 to 0.37 µg L-1, with analytical recoveries ranging from 73 to 103%, and relative standard deviations (RSDs) within the 2-20% range. The applicability of the method was demonstrated after analysing urine samples under forensic investigation.


Assuntos
Metanol , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Clomipramina , Pregabalina , Cromatografia Líquida , Solventes/química , Extração em Fase Sólida
2.
Anal Methods ; 15(3): 333-342, 2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36594640

RESUMO

The global market for new psychoactive substances (NPSs) continues to expand, and the range of drugs available on the market has probably never been wider. Synthetic cannabinoids (SCRAs) constitute the largest family of NPSs, and they go unnoticed during illicit drug market control and during routine toxicological-forensic analysis. Membrane-assisted solvent extraction (MASE) has been a novelty proposed for the simultaneous extraction of SCRAs, and urine has been selected as a model forensic-clinical sample. Isolated SCRAs were further determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). An optimised sample pre-treatment procedure consists of using 400 µL of n-hexane as an extraction phase placed inside a polypropylene (PP) membrane, adjusting the donor phase (urine) at a pH value of 5.9. Extraction was assisted by mechanical (orbital-horizontal) stirring in a temperature-controlled chamber at room temperature for 20 min. n-Hexane extracts were evaporated to dryness and re-suspended in 100 µL of mobile phase, which leads to a pre-concentration factor of 50. Method validation showed analytical recoveries higher than 80% for most SCRAs and repeatability (inter-day and intra-day assays) with RSD values lower than 20%. The proposed method was found to be selective and sensitive and limits of quantification (LOQs) between 0.10 and 1.0 µg L-1 were achieved.


Assuntos
Agonistas de Receptores de Canabinoides , Canabinoides , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Canabinoides/urina , Solventes
3.
J Anal Toxicol ; 43(3): 196-202, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30395206

RESUMO

A reliable method based on high-performance liquid chromatography-tandem mass spectrometry has been developed for the assessment of coca alkaloids/metabolites [cocaine (COC), benzoylecgonine (BE), cocaethylene (CE), ecgonine methyl ester (EME), anhydroecgonine methyl ester (AEME), tropococaine (TRO), transcinnamoylcocaine (trCIN), cuscohygrine (CUS) and hygrine (HYG)] in oral fluid samples from cocaine abusers and from coca leaves consumers (coca leaves chewers and coca tea drinkers). Oral fluid samples were collected by the passive drool technique (spitting), and after centrifugation the supernatant was treated for protein removal by adding acidified acetonitrile. The developed method was fully validated according to the international criteria and good results have been obtained (intraday and inter-day precisions were lower than ±20%, intraday and inter day accuracy was within the 75-116% range, and LODs/LOQs was lower and close to cut-off values for COC and BE). The proposed method has been successfully applied to oral fluid samples from cocaine abusers, and also from coca leave chewers and coca tea drinkers. CUS and HYG were only found in oral fluid from people who chewed coca leaves and drank coca tea and were not detected in cocaine abusers. Both CUS and HYG could be good markers in oral fluid for distinguishing people who consume coca leaves legally (coca leave chewers and coca tea drinkers) from those who consume illegal cocaine.


Assuntos
Alcaloides/análise , Coca/química , Transtornos Relacionados ao Uso de Cocaína/diagnóstico , Toxicologia Forense/métodos , Saliva/química , Detecção do Abuso de Substâncias/métodos , Cromatografia Líquida de Alta Pressão , Toxicologia Forense/instrumentação , Humanos , Limite de Detecção , Folhas de Planta/química , Padrões de Referência , Detecção do Abuso de Substâncias/instrumentação , Espectrometria de Massas em Tandem
4.
Drug Test Anal ; 11(1): 33-44, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29962002

RESUMO

Synthetic cathinones are a type of drug belonging to group of new psychoactive substances (NPSs). The illicit market for these substances is characterized by the continuous introduction to the market of new analogs to evade legislation and to avoid detection. New screening and confirmation assays are therefore needed, mainly in forensic/clinical samples. In the current development, a porous membrane-protected, micro-solid-phase extraction (µ-SPE) has been developed for the assessment of several cathinones in urine. The µ-SPE device consisted of a cone-shaped polypropylene (PP) porous membrane containing the adsorbent (molecularly imprinted polymers, MIPs, synthesized for the first time for this class of drugs). MIPs were prepared using ethylone and 3-methylmethcathinone (3-MMC) as templates, ethylene glycol dimethacrylate (EGDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2´-azobisisobutyronitrile (AIBN) as an initiator. The prepared ethylone-based MIP and 3-MMC-based MIP have been fully characterized and evaluated as new selective adsorbents for µ-SPE. Cathinones separation/determination was performed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Optimum loading conditions (pH 5.0, loading for 4.0 minutes under orbital-horizontal shaking at 200 rpm) and elution conditions [2.0 mL of 75:20:5 heptane/2-propanol/ammonium hydroxide and ultrasounds assistance (37 kHz, 325 W) for 4.0 minutes] were found for ethylone-based MIP. Validation (intra-day and inter-day precision and analytical recovery) showed RSD values lower than 9 and 10% for intra-day and inter-day precision, and within the 88%-101% range for intra-day and inter-day analytical recovery.


Assuntos
Alcaloides/urina , Impressão Molecular/métodos , Polímeros/análise , Psicotrópicos/urina , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Humanos , Impressão Molecular/normas , Microextração em Fase Sólida/normas , Espectrometria de Massas em Tandem/normas
5.
J Chromatogr A ; 1550: 8-20, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29605179

RESUMO

Several molecularly imprinted polymers (MIPs) have been synthesized for the first time using various synthetic cannabinoids (JWH007, JWH015 and JWH098) as template molecules. Ethylene dimethacrylate (EDMA) was used as a functional monomer for all cases. Similarly, divinylbenzene (DVB) and 2,2'-azobisisobutyronitrile (AIBN) were used as cross-linker and initiator, respectively. The prepared MIPs have been fully characterized and evaluated as new selective adsorbents for micro-solid phase extraction (µ-SPE) of synthetic cannabinoids in urine. The developed MIP-µ-SPE devices consisted of a polypropylene (PP) porous membrane containing the adsorbent (novel porous membrane protected micro-solid phase extraction based on a cone-shaped device) for operating in batch mode, which allowed a fast and integrated extraction-cleanup procedure. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used for quantifying the analytes after MIP-µ-SPE. The best performances were obtained for MIPs prepared from JWH015 as a template. Optimum loading conditions were found to be urine pH of 5.0 and adsorption time of 8.0 min under mechanical (orbital-horizontal) stirring at 100 rpm. The composition of the eluting solution consisted of 75:20:5 heptane/2-propanol/ammonium hydroxide. The elution was assisted by ultrasounds (37 kHz, 325 W) for 8.0 min. In addition, studies regarding selectivity have also been addressed for several drugs of abuse under optimized loading/adsorption conditions. Validation of the method showed good precision and analytical recovery by intra-day and inter-day assays (RSD values lower than 7 and 10% for intra-day and inter-day precision, and within the 83-100% range for intra-day and inter-day analytical recovery).


Assuntos
Canabinoides/urina , Cromatografia Líquida/métodos , Impressão Molecular/métodos , Polímeros/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Adsorção , Hidróxido de Amônia/química , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Nitrilas/química , Reprodutibilidade dos Testes , Fatores de Tempo , Compostos de Vinila/química
6.
Talanta ; 181: 232-238, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29426506

RESUMO

A molecularly imprinted polymer - Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL-1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL-1and 0.117mgL-1, respectively; whereas, 0.015mgL-1 (LOD) and 0.050mgL-1 (LOQ) were obtained for serum.


Assuntos
Cocaína/análise , Impressão Molecular , Polímeros/química , Pontos Quânticos/química , Saliva/química , Espectrometria de Fluorescência/métodos , Cocaína/sangue , Cocaína/isolamento & purificação , Transtornos Relacionados ao Uso de Cocaína/sangue , Transtornos Relacionados ao Uso de Cocaína/diagnóstico , Manganês/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sulfetos/química , Compostos de Zinco/química
7.
Anal Bioanal Chem ; 409(5): 1207-1220, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27815614

RESUMO

A molecularly imprinted polymer (MIP) selective for cannabinoids [Δ9-tetrahydrocannabinol (Δ9-THC), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (Δ9-THC-COOH), and 11-hydroxy-Δ9-tetrahydrocannabinol (Δ9-THC-OH)] has been synthesized, fully characterized, and applied to the assessment of plasma and urine analysis of marijuana abuse by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Δ9-THC-COOH was used as a template molecule, whereas ethylene glycol dimethacrylate (EGDMA) was used as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The prepared MIP was found to be highly selective for cannabinoids typically found in blood and urine, and also for cannabinol (CBN) and cannabidiol (CBD). MIP beads (50 mg) were loaded inside a cone-shaped device made of a polypropylene (PP) membrane for microsolid-phase extraction (µ-SPE) in batch mode. Optimum retention of analytes (0.1 to 1.0 mL of plasma/urine) was achieved by fixing plasma/urine pH at 6.5 and assisting the procedure by mechanical shaking (150 rpm, 40 °C, 12 min). Optimum elution conditions implied 2 mL of a 90:10 methanol/acetic acid and ultrasound extraction (35 kHz, 325 W) for 6 min. Good precision was assessed by intra-day and inter-day assays. In addition, the method was found to be accurate after intra-day and inter-day analytical recovery assays and after analyzing control serum and urine control samples. The limits of quantification were in the range of 0.36-0.49 ng L-1 (plasma analysis) and 0.47-0.57 ng L-1 (urine analysis). These values are low enough for confirmative conclusions regarding marijuana abuse through blood and urine analysis. Graphical Abstract ᅟ.


Assuntos
Canabinoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Impressão Molecular , Polímeros/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Canabinoides/sangue , Canabinoides/urina , Limite de Detecção , Reprodutibilidade dos Testes
8.
Sci Justice ; 56(6): 453-463, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27914552

RESUMO

During the excavation of the Spanish Civil War mass grave at La Pedraja (Burgos, Spain), 104 individuals were found interred within it, 45 of which displayed brains that were preserved but dehydrated and reduced in size. This exceptional finding has resulted in the formation of a multidisciplinary team, with the aim of obtaining as much information as possible and to primarily understand the taphonomic phenomena that has led to the preservation of these brains. The following types of analyses were undertaken on three of these brains: macroscopy, histology, radiology, chemical-toxicology, genetics, chemical analysis of the soil and 3D modelling for stereolithography. The historical context was considered, plus all archaeological and other forensic data provided by the investigation of the mass grave. The results of the analyses on these morphologically identifiable human brains confirmed the presence of nerve structures, fatty acids, and in one case ante-mortem evidence for an intracranial haemorrhage. The fatty acid profile corresponds to the process of saponification. Therefore, the interpretation is that the preservation of these brains at the mass grave of La Pedraja was due to the saponification process, which was influenced by the manner and cause of death, the chemical composition of the brain, the physicochemical properties of the soil and the meteorological conditions at the time.


Assuntos
Encéfalo/patologia , Sepultamento , Múmias , Diagnóstico por Imagem , Exumação , Antropologia Forense , Patologia Legal , História do Século XX , Humanos , Modelos Anatômicos , Impressão Tridimensional , Espanha
9.
Anal Bioanal Chem ; 408(23): 6393-402, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27405875

RESUMO

A simple sample pre-treatment method based on solid phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized and validated for the assessment of 15 residual solvents (2-propanol, 2-methylpentane, 3-methylpentane, acetone, ethyl acetate, benzene, hexane, methylcyclohexane, methylcyclopentane, m-xylene, propyl acetate, toluene, 1,2,4-trimethylbenzene, dichloromethane, and ethylbenzene) in seized illicit cocaine and heroin. DMSO and DMF as sample diluents were found to offer the best residual solvent transference to the head space for further adsorption onto the SPME fiber, and the developed method therefore showed high sensitivity and analytical recovery. Variables affecting SPME were fully evaluated by applying an experimental design approach. Best conditions were found when using an equilibration time of 5 min at 70 °C and headspace sampling of residual solvents at the same temperature for 15 min. Method validation, performed within the requirements of international guidelines, showed excellent sensitivity, as well as intra- and inter-day precision and accuracy. The proposed methodology was applied to 96 cocaine samples and 14 heroin samples seized in Galicia (northwestern Spain) within 2013 and 2014.


Assuntos
Anestésicos Locais/análise , Cocaína/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Heroína/análise , Drogas Ilícitas/análise , Entorpecentes/análise , Microextração em Fase Sólida/métodos , Limite de Detecção , Solventes/análise , Detecção do Abuso de Substâncias/métodos
10.
Anal Chem ; 88(5): 2734-41, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26857857

RESUMO

A new molecularly imprinted polymer (MIP)-based fluorescent artificial receptor has been prepared by anchoring a selective MIP for cocaine (COC) on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). The prepared material combines the high selectivity attributed to MIPs and the sensitive fluorescent property of the Mn-doped ZnS QDs. Simple and low cost methods have therefore been optimized for assessing cocaine abuse in urine by monitoring the fluorescence quenching when the template (COC) and also metabolites from COC [benzoylecgonine (BZE) and ecgonine methyl ester (EME)] are present. Fluorescence quenching was not observed when performing experiments with other drugs of abuse (and their metabolites) or when using nonimprinted polymer (NIP)-coated QDs. Under optimized operating conditions (1.5 mL of 200 mg L(-1) MIP-coated QDs solution, pH 5.5, and 15 min before fluorescence scanning) two analytical methods were developed/validated. One of the procedures (direct method) consisted of urine sample 1:20 dilution before fluorescence measurements. The method has been found to be fast, precise, and accurate, but the standard addition technique for performing the analysis was required because of the existence of matrix effect. The second procedure performed a solid phase extraction (SPE) first, avoiding matrix effect and allowing external calibration. The limits of detection of the methods were 0.076 mg L(-1) (direct method) and 0.0042 mg L(-1) (SPE based method), which are lower than the cutoff values for confirmative conclusions regarding cocaine abuse.


Assuntos
Cocaína/análogos & derivados , Cocaína/urina , Corantes Fluorescentes/química , Manganês/química , Impressão Molecular/métodos , Polímeros/química , Pontos Quânticos , Sulfetos/química , Compostos de Zinco/química , Calibragem , Humanos , Limite de Detecção , Espectrometria de Fluorescência , Detecção do Abuso de Substâncias/métodos
11.
Talanta ; 147: 641-9, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26592657

RESUMO

A magnetic molecularly imprinted polymer (MMIP) has been synthesized and applied for cocaine (COC) and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) recognition/pre-concentration in urine samples. The MMIP has been prepared using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, Fe3O4 magnetite as a magnetic component, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The best results (MIP layer on the surface of the magnetic nanoparticles) and physical properties of the prepared MMIP were obtained when assisting the synthesis procedure with ultrasounds (325W, 37kHz, 30°C, 4h). After solid phase extraction (SPE) with the prepared adsorbent material, analytes were determined by high performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS). Variables affecting the SPE process (batch mode) were fully evaluated. Optimum retention of analytes (1.8mL of urine and 50mg of MMIP) was achieved by fixing the urine pH at 5.5 (use of a KH2PO4/NaOH, pH 5.5 buffer solution), and magnetic stirring (25°C, 700rpm) for 10min. Elution was performed by using 2mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasounds (325W, 35kHz, room temperature) for 5min. The method was validated according to the guidance for bioanalytical method validation of the US Department of Health and Human Services, Food and Drug Administration. The detection limits were in the range of 0.39-1.4ngL(-1). The relative standard deviations of intra- and inter-day tests ranged from 5 to 11% and from 3 to 11%, respectively. Analytical recoveries were in the range of 79-106% when spiking drug-free urine samples at three concentration levels. Good results were also obtained after analyzing an FDT +25% control material. The applicability of the method was proved for screening/quantifying COC, BZE, CE and EME in several samples from poly-drug abusers.


Assuntos
Cocaína/análogos & derivados , Cromatografia Líquida de Alta Pressão , Cocaína/urina , Óxido Ferroso-Férrico/química , Humanos , Limite de Detecção , Fenômenos Magnéticos , Metacrilatos/química , Impressão Molecular , Nitrilas/química , Polietilenoglicóis/química , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem , Ondas Ultrassônicas , Compostos de Vinila/química
12.
Biosens Bioelectron ; 75: 213-21, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26319164

RESUMO

Mn-doped ZnS quantum dots (QDs) coated with a molecularly imprinted polymer (MIP) material selective toward cocaine and its metabolites have been prepared and applied to cocaine (COC) and metabolites assessment by spectrofluorimetry. Ultrasound irradiation (37kHz) was novelty used for performing the Mn-doped ZnS QDs synthesis as well as for preparing the QD based MIP-coated composite by precipitation polymerization (imprinting process). This fact allowed the synthesis to be accomplished in four hours. In addition, the use of ultrasound irradiation during MIP-QDs synthesis increased the homogeneity of the QDs size, and reduced nanoparticles agglomeration. MIP was synthesized using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. The fluorescence of MIP-coated QDs was quenched by the template (COC) and also by metabolites from COC such as benzoylecgonine (BZE), and ecgonine methyl ester (EME). Quenching was not observed when performing experiments with non-imprinted polymer (NIP)-coated QDs; and also, fluorescence quenching of MIP-coated QDs was not observed by other drugs of abuse and metabolites (heroin and cannabis abuse). This fact indicates that the prepared material recognize only COC (template) and metabolites.


Assuntos
Técnicas Biossensoriais , Cocaína/isolamento & purificação , Impressão Molecular , Espectrometria de Fluorescência , Humanos , Manganês/química , Polímeros/química , Pontos Quânticos/química , Sulfetos/química , Telúrio/química , Compostos de Zinco/química
13.
Anal Chim Acta ; 898: 50-9, 2015 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-26526910

RESUMO

Porous membrane-protected micro-solid phase extraction (µ-SPE) using a molecularly imprinted polymer (MIP) as an adsorbent has been proposed as an integrated extraction-cleanup procedure for isolating cocaine (COC) and its metabolites [benzoylecgonine (BZE), ecgonine methyl ester (EME), and cocaethylene (CE)] from human urine. MIP beads have been synthesized using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2'-azobisisobutyronitrile (AIBN) as an initiator. High performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS) has been used for quantifying the analytes after MIP-µ-SPE. Variables such as urine pH, adsorption temperature and time, mechanical (orbital-horizontal) stirring; and composition of the eluting solution and eluting time, were evaluated. The proposed method was shown to be precise and accurate [relative standard deviations (RSDs) of intra- and inter-day tests ranging from 3 to 8% and from 2 to 10%, respectively]; and analytical recoveries in the range of 89-100%). In addition, excellent accuracy was also verified after analyzing a FDT +25% control material for BZE. The detection limits were in the range of 0.16-1.7 ng L(-1), low enough for confirmative conclusions regarding cocaine abuse. The method was finally applied for screening/quantifying cocaine and metabolites in urine samples from poly-drug abusers.


Assuntos
Cromatografia Líquida/métodos , Cocaína/urina , Impressão Molecular , Polímeros/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Microscopia Eletrônica de Varredura , Porosidade , Reprodutibilidade dos Testes
14.
Anal Bioanal Chem ; 407(17): 4907-25, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25935676

RESUMO

Alcohol is the most popular legal drug used in our society today, and its consumption by pregnant women remains an important public health problem. Gestational alcohol consumption can result in a continuum of adverse fetal outcomes known as fetal alcohol spectrum disorder (FASD). Effective strategies are needed to prevent the increasing adoption of risky drinking behaviors. Because ethanol itself is only measurable for a few hours after ethanol intake in conventional matrices including blood, urine, and sweat, these matrices are only useful to detect recent ethanol exposure. Since approximately early 2000, the non-oxidative ethanol metabolites have received increasing attention because of their specificity and, in some cases, wide time window of detection in non-conventional matrices including hair and meconium. In the attempt to update analytical methods for the determination of non-oxidative markers of alcohol, the objective of this study is to review published studies that measure fatty-acid ethyl esters (FAEE), ethyl glucuronide (EtG), and phosphatidylethanol (PEth) in alternative biological matrices, focusing on the extraction and detection methods and full analytical conditions used.


Assuntos
Consumo de Bebidas Alcoólicas/sangue , Consumo de Bebidas Alcoólicas/urina , Alcoolismo/diagnóstico , Transtornos do Espectro Alcoólico Fetal/diagnóstico , Alcoolismo/sangue , Alcoolismo/urina , Biomarcadores/análise , Biomarcadores/sangue , Biomarcadores/urina , Cromatografia Líquida/métodos , Ésteres/análise , Ésteres/sangue , Ésteres/urina , Ácidos Graxos/análise , Ácidos Graxos/sangue , Ácidos Graxos/urina , Feminino , Transtornos do Espectro Alcoólico Fetal/sangue , Transtornos do Espectro Alcoólico Fetal/urina , Glucuronatos/análise , Glucuronatos/sangue , Glucuronatos/urina , Glicerofosfolipídeos/análise , Glicerofosfolipídeos/sangue , Glicerofosfolipídeos/urina , Cabelo/química , Humanos , Recém-Nascido , Microextração em Fase Líquida/métodos , Espectrometria de Massas/métodos , Mecônio/química , Gravidez
15.
J Pharm Biomed Anal ; 100: 74-78, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25137651

RESUMO

This article presents results from 47 meconium samples, which were analyzed for fatty acid ethyl esters (FAEE) and ethyl glucuronide (EtG) for detection of gestational alcohol consumption. A validated microwave assisted extraction (MAE) method in combination with GC-MS developed in the Institute of Forensic Science (Santiago de Compostela) was used for FAEE and the cumulative concentration of ethyl myristate, ethyl palmitate and ethyl stearate with a cut-off of 600ng/g was applied for interpretation. A simple method for identification and quantification of EtG has been evaluated by ultrasonication followed solid phase extraction (SPE). Successful validation parameters were obtained for both biochemical markers of alcohol intake. FAEE and EtG concentrations in meconium ranged between values lower than LOD and 32,892ng/g or 218ng/g respectively. We have analyzed FAEE and EtG in the same meconium aliquot, enabling comparison of the efficiency of gestational ethanol exposure detection. Certain agreement between the two biomarkers was found as they are both a very specific alcohol markers, making it a useful analysis for confirmation.


Assuntos
Alcoolismo/diagnóstico , Ésteres/análise , Ácidos Graxos/análise , Glucuronatos/análise , Mecônio/química , Complicações na Gravidez/diagnóstico , Detecção do Abuso de Substâncias/métodos , Adulto , Alcoolismo/metabolismo , Biomarcadores/análise , Calibragem , Cromatografia Líquida , Esterificação , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Recém-Nascido , Micro-Ondas , Miristatos/análise , Ácidos Palmíticos/análise , Valor Preditivo dos Testes , Gravidez , Complicações na Gravidez/metabolismo , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Estearatos/análise , Detecção do Abuso de Substâncias/normas , Espectrometria de Massas em Tandem
16.
Talanta ; 117: 235-41, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24209335

RESUMO

A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry.


Assuntos
Analgésicos Opioides/sangue , Cocaína/sangue , Codeína/sangue , Teste em Amostras de Sangue Seco/métodos , Morfina/sangue , Transtornos Relacionados ao Uso de Substâncias/sangue , Humanos , Limite de Detecção , Metanol/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem
17.
J Chromatogr A ; 1316: 15-22, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24112826

RESUMO

The possibility of assisting enzymatic hydrolysis (EH) procedures by sample disruption mechanisms inherent to matrix solid phase dispersion (MSPD) has been explored in the current study. EH of hair specimens from poly-drug abusers was assisted by dispersing/blending the sample (0.05 g) with alumina (2.25 g) before loading the dissolved enzyme (6 mL of 1 mg mL(-1) Pronase E in 1.4 M/1.4 M Tris/HCl, pH 7.3) through the hair-alumina solid phase packaged inside a disposable MSPD syringe. The MSPD-EH method was developed, and it proved to offer quantitative results when isolating cocaine, benzoylecgonine (BZE), codeine, morphine and 6-monoacethylmorphine (6-MAM) from human hair samples. The procedure allows an on column clean-up/pre-concentration procedure of the isolated targets by attaching a previously conditioned Oasis HLB cartridge to the end of the MSPD syringe. The EH procedure of human hair with Pronase E can therefore be shortened to approximately 30 min. Within this time, sample blending/dispersion, MSPD syringe package, elution (EH when dissolved Pronase E is passing through the sample-dispersant bed), and extract clean-up and target pre-concentration stages are achieved. Gas chromatography-mass spectrometry (GC-MS) was used for determining each target after elution from the Oasis HLB cartridges with 2 mL of 2% (v/v) acetic acid in methanol, concentration by N2 stream evaporation, and dried extract derivatization with N-methyl-tert-butylsilyltrifluoroacetamide (BSTFA) and chlorotrimethylsilane (TMCS). The method was validated according to the guidance for bioanalytical method validation of the US Department of Health and Human Services, Food and Drug Administration. The simplicity of the proposed approach makes it a useful procedure for screening/quantifying drugs of abuse in hair specimens from poly-drug abusers.


Assuntos
Cocaína/isolamento & purificação , Cabelo/química , Drogas Ilícitas/análise , Derivados da Morfina/isolamento & purificação , Extração em Fase Sólida/métodos , Cocaína/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Hidrólise , Derivados da Morfina/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Anal Chim Acta ; 784: 25-32, 2013 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-23746404

RESUMO

A micro-analytical method based on spotting urine samples (20µL) onto blood/urine spot collection cards followed by air-drying and extraction (dried urine spot, DUS) was developed and validated for the screening/confirmation assay of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE). Acetonitrile (3 mL) was found to be a useful solvent for target extraction from DUSs under an orbital-horizontal stirring at 180 rpm for 10 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions, and by using multiple reaction monitoring (MRM) with one precursor ion/product ion transition for the identification and quantification (deuterated analogs of each target as internal standards) of each analyte. The limits of detection of the method were 0.26, 0.94, 1.5, 1.1, and 2.0 ng mL(-1), for cocaine, BZE, codeine, morphine and 6-MAM, respectively; whereas, relative standard deviations of intra- and inter-day precision were lower than 8 and 11%, respectively, and intra- and inter-day analytical recoveries ranged from 94±4 to 105±3%. The small volume of urine required (20 µL), combined with the simplicity of the analytical technique makes it a useful procedure for screening/quantifying drugs of abuse. The method was successfully applied to the analysis of urine from polydrug abusers.


Assuntos
Analgésicos Opioides/urina , Cocaína/urina , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Urinálise/métodos , Analgésicos Opioides/metabolismo , Calibragem , Cocaína/metabolismo , Humanos , Limite de Detecção , Padrões de Referência , Espectrofotometria Atômica , Detecção do Abuso de Substâncias/instrumentação , Transtornos Relacionados ao Uso de Substâncias/urina , Espectrometria de Massas em Tandem/instrumentação , Urinálise/instrumentação
20.
Anal Bioanal Chem ; 404(1): 147-55, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22669306

RESUMO

Ethanol is a legal and widely available substance. There are health and social consequences associated with its abuse. One of the most important problems is related to alcohol consumption during pregnancy. In fact, prenatal ethanol exposure can be associated with fetal alcohol spectrum disorder (FASD), a term used to describe a wide range of potentially lifelong effects that include physical, mental, behavioral, and learning disabilities. Fatty acid ethyl esters (FAEEs), which are non-oxidative metabolites of ethanol, are currently used as biomarkers of direct ethanol consumption in different matrices, including hair, blood, skin surface, and meconium. Analysis of these compounds in meconium reveals exposure to alcohol during the second and third trimesters of pregnancy. An important finding for evaluation of gestational ethanol exposure is the fact that FAEEs do not cross the placenta. Because they accumulate in the fetal gut from approximately the 20th week of gestation until birth, this provides a wide window of detection of chronic exposure to alcohol. The sum of the concentrations of all the FAEEs, with a cutoff of 2 nmol g(-1) or 600 ng g(-1) meconium, has been recommended as evidence of maternal alcohol use. We introduce a novel technique to quantify ethyl myristate, ethyl palmitate, ethyl stearate, and their deuterated analogues (as internal standards, IS) in meconium using microwave-assisted extraction (MAE) coupled with gas chromatography-mass spectrometry (GC-MS). Limits of detection and quantification were 50 and 100 ng g(-1) for all analytes except ethyl stearate (LOD 100 ng g(-1) and LOQ 500 ng g(-1)). Calibration curves were linear from the LOQ to 5000 ng g(-1). The validated method was applied to the analysis of 81 meconium samples.


Assuntos
Etanol/análise , Transtornos do Espectro Alcoólico Fetal/diagnóstico , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mecônio/química , Efeitos Tardios da Exposição Pré-Natal/diagnóstico , Etanol/isolamento & purificação , Etanol/metabolismo , Etanol/toxicidade , Feminino , Transtornos do Espectro Alcoólico Fetal/metabolismo , Humanos , Lactente , Recém-Nascido , Masculino , Micro-Ondas , Gravidez , Efeitos Tardios da Exposição Pré-Natal/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...