Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 6): 1149-1155, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37850561

RESUMO

The unique diffraction geometry of ESRF beamline ID06-LVP offers continuous static 2D or azimuthally resolving data collections over all accessible solid angles available to the tooling geometry. The system is built around a rotating custom-built Pilatus3 CdTe 900k-W detector from Dectris, in a configuration equivalent to three butted 300k devices. As a non-standard geometry, here the method of alignment, correction and subsequent integration for any data collected over all solid angles accessible, or over any azimuthal range contained therein, are provided and illustrated by parameterizing and extending existing pyFAI routines. At 1° integrated intervals, and typical distances (2.0 m), the system covers an area of near 2.5 m2 (100 Mpx square equivalent), to 0.65 Šresolution, at 53 keV from a total dataset of some 312 Mpx. Standard FWHMs of SRM660a LaB6 vary from 0.005° to 0.01°, depending on beam size, energy and sample dimensions, and are sampled at an elevated rate. The azimuthal range per static frame ranges from <20° to ∼1° over the full range of the detector surface. A full 2θ-intensity data collection at static azimuth takes 1-3 s typically, and can be reduced to ms-1 rates for measurements requiring time-rate determination. A full solid-angle collection can be completed in a minute. Sample detector distances are accessible from 1.6 m to 4.0 m.

2.
Int J Radiat Oncol Biol Phys ; 113(5): 967-973, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35483539

RESUMO

PURPOSE: The high potential of microbeam radiation therapy (MRT) in improving tumor control while reducing side effects has been shown by numerous preclinical studies. MRT offers a widened therapeutic window by using the periodical spatial fractionation of synchrotron generated x-rays into an array of intense parallel microbeams. MRT now enters a clinical transfer phase. As proof of principle and cornerstone for the safe clinical transfer of MRT, we conducted a "first in dog" trial under clinical conditions. In this report, we evaluated whether a 3-dimensional conformal MRT can be safely delivered as exclusive radiosurgical treatment in animal patients METHODS AND MATERIALS: We irradiated a 17.5-kg French bulldog for a spontaneous brain tumor (glioma suspected on magnetic resonance imaging) with conformal high-dose-rate microbeam arrays (50-µm-wide microbeams, replicated with a pitch of 400 µm) of synchrotron-generated x-rays. The dose prescription adjusted a minimal cumulated valley dose of 2.8 Gy to the plnning target volume (PTV) (cinical target volume (CTV)+ 1 mm). Thus, each beam delivered 20 to 25 Gy to the target as peak doses, and ∼1 Gy as valley doses RESULTS: The treatment was successfully delivered. Clinical follow-up over 3 months showed a significant improvement of the dog's quality of life: the symptoms disappeared. Magnetic resonance imaging, performed 3 months after irradiation, revealed reduction in tumor size (-87.4%) and mass effect with normalization of the left lateral ventricle. CONCLUSIONS: To our knowledge, this neuro-oncologic veterinary trial is the first 3-dimensional conformal synchrotron x-ray MRT treatment of a spontaneous intracranial tumor in a large animal. It is an essential last step toward the clinical transfer of MRT in the near future to demonstrate the feasibility and safety of treating deep-seated tumors using synchrotron-generated microbeams.


Assuntos
Neoplasias Encefálicas , Glioma , Radiocirurgia , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/veterinária , Cães , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/radioterapia , Qualidade de Vida , Radiocirurgia/métodos , Síncrotrons
3.
J Synchrotron Radiat ; 29(Pt 1): 167-179, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34985434

RESUMO

Results of the 2018 commissioning and experimental campaigns of the new High Power Laser Facility on the Energy-dispersive X-ray Absorption Spectroscopy (ED-XAS) beamline ID24 at the ESRF are presented. The front-end of the future laser, delivering 15 J in 10 ns, was interfaced to the beamline. Laser-driven dynamic compression experiments were performed on iron oxides, iron alloys and bismuth probed by online time-resolved XAS.

4.
J Synchrotron Radiat ; 23(1): 339-43, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698083

RESUMO

A fast positioning method for brain tumor microbeam irradiations for preclinical studies at third-generation X-ray sources is described. The three-dimensional alignment of the animals relative to the X-ray beam was based on the X-ray tomography multi-slices after iodine infusion. This method used pink-beam imaging produced by the ID17 wiggler. A graphical user interface has been developed in order to define the irradiation parameters: field width, height, number of angles and X-ray dose. This study is the first reporting an image guided method for soft tissue synchrotron radiotherapy. It allowed microbeam radiation therapy irradiation fields to be reduced by a factor of ∼20 compared with previous studies. It permitted more targeted, more efficient brain tumor microbeam treatments and reduces normal brain toxicity of the radiation treatment.


Assuntos
Neoplasias Encefálicas/radioterapia , Animais , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética , Ratos , Ratos Endogâmicos F344
5.
J Synchrotron Radiat ; 17(3): 325-31, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20400830

RESUMO

A fast 50 microm-accuracy alignment procedure has been developed for the radiosurgery of brain lesions in rats, using microbeam radiation therapy. In vivo imaging was performed using the pink beam (35-60 keV) produced by the ID17 wiggler at the ESRF opened at 120 mm and filtered. A graphical user interface has been developed in order to define the irradiation field size and to position the target with respect to the skull structures observed in X-ray images. The method proposed here allows tremendous time saving by skipping the swap from white beam to monochromatic beam and vice versa. To validate the concept, the somatosensory cortex or thalamus of GAERS rats were irradiated under several ports using this alignment procedure. The magnetic resonance images acquired after contrast agent injection showed that the irradiations were selectively performed in these two expected brain regions. Image-guided microbeam irradiations have therefore been realised for the first time ever, and, thanks to this new development, the ID17 biomedical beamline provides a major tool allowing brain radiosurgery trials on animal patients.


Assuntos
Encéfalo/efeitos da radiação , Animais , Encéfalo/anatomia & histologia , Calibragem , Imageamento por Ressonância Magnética , Radiocirurgia , Ratos , Interface Usuário-Computador
6.
PLoS One ; 5(2): e9028, 2010 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-20140254

RESUMO

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy). Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range), targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3) in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing surrounding tissues. The use of synchrotron-generated X-rays enables delivery of high doses for destruction of small focal regions in human brains, with sharper dose fall-offs than those described in any other conventional radiation therapy.


Assuntos
Doses de Radiação , Radiocirurgia/métodos , Síncrotrons , Animais , Comportamento Animal/efeitos da radiação , Encéfalo/metabolismo , Encéfalo/patologia , Encéfalo/efeitos da radiação , Proteína Glial Fibrilar Ácida/metabolismo , Humanos , Imuno-Histoquímica , Imageamento por Ressonância Magnética , Método de Monte Carlo , Ratos , Fatores de Tempo , Raios X
7.
Eur Heart J ; 26(13): 1284-91, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15734769

RESUMO

AIMS: Synchrotron radiation angiography (SRA) is a novel tool for minimally invasive coronary artery imaging. The method uses subtraction of two images produced at energies bracketing the iodine K-edge after intravenous infusion of iodinated contrast agent. We investigated the accuracy of SRA for detecting in-stent restenosis (ISR). METHODS AND RESULTS: We recruited 57 men, 4-6 months after successful PTCA. We visualized the right coronary artery (RCA) in 27 patients with 36 stented segments [12 segments with ISR>50% by quantitative coronary angiography (QCA)], and the left anterior descending artery (LAD) in 30 patients with 37 stented segments (10 ISR). SRA and QCA were performed within 2 days of each other. Two experienced observers unaware of QCA data evaluated the SRA results. Image quality was good or excellent in most patients. Global sensitivity was 64%, specificity was 95%, and positive and negative predictive values were approximately 85%. Inter-observer kappa concordance coefficient was 0.86. False negatives involved short eccentric lesions and superimposed segments, most frequently of the LAD. False positives occurred in intermediate stenoses slightly overestimated by SRA. CONCLUSION: In men, this minimally invasive approach, using small radiation doses, detects significant ISR in the RCA, but the LAD poses difficulties because of superimposition with others structures.


Assuntos
Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Stents , Síncrotrons/normas , Adulto , Idoso , Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
8.
Phys Med Biol ; 50(1): 1-11, 2005 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-15715418

RESUMO

The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O2 gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.


Assuntos
Pulmão/patologia , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Gases , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Modelos Estatísticos , Oxigênio/metabolismo , Imagens de Fantasmas , Troca Gasosa Pulmonar , Coelhos , Testes de Função Respiratória , Software , Xenônio
9.
J Cereb Blood Flow Metab ; 25(2): 145-53, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15678122

RESUMO

The authors previously provided evidence of synchrotron radiation computed tomography (SRCT) efficacy for quantitative in vivo brain perfusion measurements using monochromatic X-ray beams. However, this technique was limited for small-animal studies by partial volume effects. In this paper, high-resolution absolute cerebral blood volume and blood-brain barrier permeability coefficient measurements were obtained on a rat glioma model using SRCT and a CCD camera (47x47 microm2 pixel size). This is the first report of in vivo high-resolution brain vasculature parameter assessment. The work gives interesting perspectives to quantify brain hemodynamic changes accurately in healthy and pathological small animals.


Assuntos
Barreira Hematoencefálica/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Permeabilidade , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Animais , Encéfalo/irrigação sanguínea , Linhagem Celular Tumoral , Circulação Cerebrovascular/fisiologia , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...