1.
Phys Med ; 120: 103334, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520889

RESUMO

PURPOSE: Contrast-enhanced digital mammography (CEDM) is a relatively new imaging technique recombining low- and high-energy mammograms to emphasise iodine contrast. This work aims to perform a multicentric physical and dosimetric characterisation of four state-of-the-art CEDM systems. METHODS: We evaluated tube output, half-value-layer (HVL) for low- and high-energy and average glandular dose (AGD) in a wide range of equivalent breast thicknesses. CIRS phantom 022 was used to estimate the overall performance of a CEDM examination in the subtracted image in terms of the iodine difference signal (S). To calculate dosimetric impact of CEDM examination, we collected 4542 acquisitions on patients. RESULTS: Even if CEDM acquisition strategies differ, all the systems presented a linear behaviour between S and iodine concentration. The curve fit slopes expressed in PV/mg/cm2 were in the range [92-97] for Fujifilm, [31-32] for GE Healthcare, [35-36] for Hologic, and [114-130] for IMS. Dosimetric data from patients were matched with AGD values calculated using equivalent PMMA thicknesses. Fujifilm exhibited the lowest values, while GE Healthcare showed the highest. CONCLUSION: The subtracted image showed the ability of all the systems to give important information about the linearity of the signal with the iodine concentrations. All the patient-collected doses were under the AGD EUREF 2D Acceptable limit, except for patients with thicknesses ≤35 mm belonging to GE Healthcare and Hologic, which were slightly over. This work demonstrates the importance of testing each CEDM system to know how it performs regarding dose and the relationship between PV and iodine concentration.


Assuntos
Neoplasias da Mama , Iodo , Humanos , Feminino , Intensificação de Imagem Radiográfica/métodos , Meios de Contraste , Mamografia/métodos , Mama , Imagens de Fantasmas
2.
Inflamm Res ; 73(4): 515-530, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38308760

RESUMO

OBJECTIVE AND DESIGN: We aimed to identify cytokines whose concentrations are related to lung damage, radiomic features, and clinical outcomes in COVID-19 patients. MATERIAL OR SUBJECTS: Two hundred twenty-six patients with SARS-CoV-2 infection and chest computed tomography (CT) images were enrolled. METHODS: CCL18, CHI3L1/YKL-40, GAL3, ANG2, IP-10, IL-10, TNFα, IL-6, soluble gp130, soluble IL-6R were quantified in plasma samples using Luminex assays. The Mann-Whitney U test, the Kruskal-Wallis test, correlation and regression analyses were performed. Mediation analyses were used to investigate the possible causal relationships between cytokines, lung damage, and outcomes. AVIEW lung cancer screening software, pyradiomics, and XGBoost classifier were used for radiomic feature analyses. RESULTS: CCL18, CHI3L1, and ANG2 systemic levels mainly reflected the extent of lung injury. Increased levels of every cytokine, but particularly of IL-6, were associated with the three outcomes: hospitalization, mechanical ventilation, and death. Soluble IL-6R showed a slight protective effect on death. The effect of age on COVID-19 outcomes was partially mediated by cytokine levels, while CT scores considerably mediated the effect of cytokine levels on outcomes. Radiomic-feature-based models confirmed the association between lung imaging characteristics and CCL18 and CHI3L1. CONCLUSION: Data suggest a causal link between cytokines (risk factor), lung damage (mediator), and COVID-19 outcomes.


Assuntos
COVID-19 , Neoplasias Pulmonares , Humanos , Interleucina-6 , SARS-CoV-2 , Proteína 1 Semelhante à Quitinase-3 , Detecção Precoce de Câncer , Radiômica , Pulmão/diagnóstico por imagem , Citocinas , Quimiocinas CC
3.
Eur J Cancer ; 199: 113553, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262307

RESUMO

AIM: The analyses here reported aim to compare the screening performance of digital tomosynthesis (DBT) versus mammography (DM). METHODS: MAITA is a consortium of four Italian trials, REtomo, Proteus, Impeto, and MAITA trial. The trials adopted a two-arm randomised design comparing DBT plus DM (REtomo and Proteus) or synthetic-2D (Impeto and MAITA trial) versus DM; multiple vendors were included. Women aged 45 to 69 years were individually randomised to one round of DBT or DM. FINDINGS: From March 2014 to February 2022, 50,856 and 63,295 women were randomised to the DBT and DM arm, respectively. In the DBT arm, 6656 women were screened with DBT plus synthetic-2D. Recall was higher in the DBT arm (5·84% versus 4·96%), with differences between centres. With DBT, 0·8/1000 (95% CI 0·3 to 1·3) more women received surgical treatment for a benign lesion. The detection rate was 51% higher with DBT, ie. 2·6/1000 (95% CI 1·7 to 3·6) more cancers detected, with a similar relative increase for invasive cancers and ductal carcinoma in situ. The results were similar below and over the age of 50, at first and subsequent rounds, and with DBT plus DM and DBT plus synthetic-2D. No learning curve was appreciable. Detection of cancers >= 20 mm, with 2 or more positive lymph nodes, grade III, HER2-positive, or triple-negative was similar in the two arms. INTERPRETATION: Results from MAITA confirm that DBT is superior to DM for the detection of cancers, with a possible increase in recall rate. DBT performance in screening should be assessed locally while waiting for long-term follow-up results on the impact of advanced cancer incidence.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Incidência , Mamografia/métodos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Idoso , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Diagnostics (Basel) ; 13(14)2023 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-37510195

RESUMO

Anterior segment optical coherence tomography (AS-OCT) allows the explore not only the anterior chamber but also the front part of the vitreous cavity. Our cross-sectional single-centre study investigated whether AS-OCT can distinguish between vitreous involvement due to vitreoretinal lymphoma (VRL) and vitritis in uveitis. We studied AS-OCT images from 28 patients (11 with biopsy-proven VRL and 17 with differential diagnosis uveitis) using publicly available radiomics software written in MATLAB. Patients were divided into two balanced groups: training and testing. Overall, 3260/3705 (88%) AS-OCT images met our defined quality criteria, making them eligible for analysis. We studied five different sets of grey-level samplings (16, 32, 64, 128, and 256 levels), finding that 128 grey levels performed the best. We selected the five most effective radiomic features ranked by the ability to predict the class (VRL or uveitis). We built a classification model using the xgboost python function; through our model, 87% of eyes were correctly diagnosed as VRL or uveitis, regardless of exam technique or lens status. Areas under the receiver operating characteristic curves (AUC) in the 128 grey-level model were 0.95 [CI 0.94, 0.96] and 0.84 for training and testing datasets, respectively. This preliminary retrospective study highlights how AS-OCT can support ophthalmologists when there is clinical suspicion of VRL.

5.
Bioconjug Chem ; 34(8): 1374-1379, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37462264

RESUMO

The targeted delivery of bioactive proteins, such as cytokines, for cancer immunotherapy approaches mostly relies on antibodies or antibody fragments. However, fusion proteins may display low tissue penetration due to a large molecular size. Small molecule ligands with high affinity toward tumor-associated antigens provide a promising alternative for the selective delivery of cytokines to tumor lesions. We developed a one-pot procedure for the site-specific thiazolidine formation between an aldehyde bearing small molecule and the in situ generated N-terminal cysteine of a bioactive protein. Thereby, neoleukin-2/15 (Neo-2/15), a computationally engineered interleukin-2 and -15 mimic, was chemically conjugated to acetazolamide plus, a potent carbonic anhydrase IX (CAIX) ligand. The conjugate retained the biological activity of Neo-2/15 and revealed its ability to accumulate in renal cell carcinoma (SK-RC-52) xenografts upon systemic intravenous administration. The results highlight the potential of small molecule targeting moieties to drive the accumulation of a protein cargo to the respective disease site while conserving the small construct size.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Citocinas , Antígenos de Neoplasias/metabolismo , Carcinoma de Células Renais/patologia , Acetazolamida/química , Acetazolamida/metabolismo , Linhagem Celular Tumoral
6.
Chem Soc Rev ; 52(16): 5352-5372, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37376918

RESUMO

T cells are an essential part of the immune system with crucial roles in adaptive response and the maintenance of tissue homeostasis. Depending on their microenvironment, T cells can be differentiated into multiple states with distinct functions. This myriad of cellular activities have prompted the development of numerous smart probes, ranging from small molecule fluorophores to nanoconstructs with variable molecular architectures and fluorescence emission mechanisms. In this Tutorial Review, we summarize recent efforts in the design, synthesis and application of smart probes for imaging T cells in tumors and inflammation sites by targeting metabolic and enzymatic biomarkers as well as specific surface receptors. Finally, we briefly review current strategies for how smart probes are employed to monitor the response of T cells to anti-cancer immunotherapies. We hope that this Review may help chemists, biologists and immunologists to design the next generation of molecular imaging probes for T cells and anti-cancer immunotherapies.


Assuntos
Sondas Moleculares , Linfócitos T , Linfócitos T/metabolismo , Corantes Fluorescentes , Imunoterapia , Imagem Óptica
7.
Eur J Radiol ; 163: 110812, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37068414

RESUMO

PURPOSE: To evaluated the accuracy of spectral parameters quantification of four different CT scanners in dual energy examinations of the lung using a dedicated phantom. METHOD: Measurements were made with different technologies of the same vendor: one dual source CT scanner (DSCT), one TwinBeam (i.e. split filter) and two sequential acquisition single source scanners (SSCT). Angular separation of Calcium and Iodine signals were calculated from scatter plots of low-kVp versus high-kVp HUs. Electron density (ρe), effective atomic number (Zeff) and Iodine concentration (Iconc) were measured using Syngo.via software. Accuracy (A) of ρe, Zeff and Iconc was evaluated as the absolute percentage difference (D%) between reference values and measured ones, while precision (P) was evaluated as the variability σ obtained by repeating the measurement with different acquisition/reconstruction settings. RESULTS: Angular separation was significantly larger for DSCT (α = 9.7°) and for sequential SSCT (α = 9.9°) systems. TwinBeam was less performing in material separation (α = 5.0°). The lowest average A was observed for TwinBeam (Aρe = [4.7 ± 1.0], AZ = [9.1 ± 3.1], AIconc = [19.4 ± 4.4]), while the best average A was obtained for Flash (Aρe = [1.8 ± 0.4], AZ = [3.5 ± 0.7], AIconc = [7.3 ± 1.8]). TwinBeam presented inferior average P (Pρe = [0.6 ± 0.1], PZ = [1.1 ± 0.2], PIconc = [10.9 ± 4.9]), while other technologies demonstrate a comparable average. CONCLUSIONS: Different technologies performed material separation and spectral parameter quantification with different degrees of accuracy and precision. DSCT performed better while TwinBeam demonstrated not excellent performance. Iodine concentration measurements exhibited high variability due to low Iodine absolute content in lung nodules, thus limiting its clinical usefulness in pulmonary applications.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomógrafos Computadorizados , Pulmão/diagnóstico por imagem , Software , Imagens de Fantasmas
8.
Angew Chem Int Ed Engl ; 61(41): e202207508, 2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-35993914

RESUMO

Increased levels of tumor-associated macrophages (TAMs) are indicators of poor prognosis in most cancers. Although antibodies and small molecules blocking the recruitment of macrophages to tumors are under evaluation as anticancer therapies, these strategies are not specific for macrophage subpopulations. Herein we report the first enzyme-activatable chemokine conjugates for effective targeting of defined macrophage subsets in live tumors. Our constructs exploit the high expression of chemokine receptors (e.g., CCR2) and the activity of cysteine cathepsins in TAMs to target these cells selectively over other macrophages and immune cells (e.g., neutrophils, T cells, B cells). Furthermore, we demonstrate that cathepsin-activatable chemokines are compatible with both fluorescent and therapeutic cargos, opening new avenues in the design of targeted theranostic probes for immune cells in the tumor microenvironment.


Assuntos
Cisteína , Macrófagos Associados a Tumor , Catepsinas , Quimiocinas , Receptores de Quimiocinas , Microambiente Tumoral
9.
Curr Oncol ; 29(8): 5179-5194, 2022 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-35892979

RESUMO

The purpose of this multi-centric work was to investigate the relationship between radiomic features extracted from pre-treatment computed tomography (CT), positron emission tomography (PET) imaging, and clinical outcomes for stereotactic body radiation therapy (SBRT) in early-stage non-small cell lung cancer (NSCLC). One-hundred and seventeen patients who received SBRT for early-stage NSCLC were retrospectively identified from seven Italian centers. The tumor was identified on pre-treatment free-breathing CT and PET images, from which we extracted 3004 quantitative radiomic features. The primary outcome was 24-month progression-free-survival (PFS) based on cancer recurrence (local/non-local) following SBRT. A harmonization technique was proposed for CT features considering lesion and contralateral healthy lung tissues using the LASSO algorithm as a feature selector. Models with harmonized CT features (B models) demonstrated better performances compared to the ones using only original CT features (C models). A linear support vector machine (SVM) with harmonized CT and PET features (A1 model) showed an area under the curve (AUC) of 0.77 (0.63-0.85) for predicting the primary outcome in an external validation cohort. The addition of clinical features did not enhance the model performance. This study provided the basis for validating our novel CT data harmonization strategy, involving delta radiomics. The harmonized radiomic models demonstrated the capability to properly predict patient prognosis.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Neoplasias Pulmonares/patologia , Recidiva Local de Neoplasia , Radiocirurgia/métodos , Estudos Retrospectivos
10.
J Chem Theory Comput ; 18(8): 5068-5078, 2022 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-35837736

RESUMO

Existing computational methods for estimating pKa values in proteins rely on theoretical approximations and lengthy computations. In this work, we use a data set of 6 million theoretically determined pKa shifts to train deep learning models, which are shown to rival the physics-based predictors. These neural networks managed to infer the electrostatic contributions of different chemical groups and learned the importance of solvent exposure and close interactions, including hydrogen bonds. Although trained only using theoretical data, our pKAI+ model displayed the best accuracy in a test set of ∼750 experimental values. Inference times allow speedups of more than 1000× compared to physics-based methods. By combining speed, accuracy, and a reasonable understanding of the underlying physics, our models provide a game-changing solution for fast estimations of macroscopic pKa values from ensembles of microscopic values as well as for many downstream applications such as molecular docking and constant-pH molecular dynamics simulations.


Assuntos
Aprendizado Profundo , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Proteínas/química , Eletricidade Estática
11.
Angew Chem Weinheim Bergstr Ger ; 134(41): e202207508, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-38505293

RESUMO

Increased levels of tumor-associated macrophages (TAMs) are indicators of poor prognosis in most cancers. Although antibodies and small molecules blocking the recruitment of macrophages to tumors are under evaluation as anticancer therapies, these strategies are not specific for macrophage subpopulations. Herein we report the first enzyme-activatable chemokine conjugates for effective targeting of defined macrophage subsets in live tumors. Our constructs exploit the high expression of chemokine receptors (e.g., CCR2) and the activity of cysteine cathepsins in TAMs to target these cells selectively over other macrophages and immune cells (e.g., neutrophils, T cells, B cells). Furthermore, we demonstrate that cathepsin-activatable chemokines are compatible with both fluorescent and therapeutic cargos, opening new avenues in the design of targeted theranostic probes for immune cells in the tumor microenvironment.

12.
BMC Pulm Med ; 21(1): 327, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34670551

RESUMO

BACKGROUND: Detection of small peripheral lung nodules is constantly increasing with the development of low dose computed tomography lung cancer screening programs. A tissue diagnosis is often required to confirm malignity, with endobronchial biopsies being associated with a lower pneumothorax rate than percutaneous approaches. Endoscopic diagnosis of peripheral small size lung nodules is however often challenging using traditional bronchoscopy and endobronchial ultrasound alone. New virtual bronchoscopic navigation techniques such as electromagnetic navigational bronchoscopy (ENB) have developed to improve peripheral navigation, with diagnostic yield however remaining in the 30-50% range for small lesions. Recent studies have shown the benefits of combining Cone beam computed tomography (CBCT) with ENB to improve diagnostic yield to up to 83%. The use of ENB however remains limited by disposable cost, bronchus sign dependency and inaccuracies due to CT to body divergence. CASE PRESENTATION: This case report highlights the feasibility and usefulness of CBCT-guided bronchoscopy for the sampling of lung nodules difficult to reach through traditional bronchoscopy because of nodule size and peripheral position. Procedure was scheduled in a mobile robotic hybrid operating room with patient under general anaesthesia. CBCT acquisition was performed to localize the target lesion and plan the best path to reach it into bronchial tree. A dedicated software was used to segment the lesion and the bronchial path which 3D outlines were automatically fused in real time on the fluoroscopic images to augment live guidance. Navigation to the lesion was guided with bronchoscopy and augmented fluoroscopy alone. Before the sampling, CBCT imaging was repeated to confirm the proper position of the instrument into the lesion. Four transbronchial needle aspirations (TBNA) were performed and the tissue analysis showed a primary lung adenocarcinoma. CONCLUSIONS: CBCT and augmented fluoroscopy technique is a safe and effective and has potential to improve early stage peripheral lesions endobronchial diagnostic yield without ENB. Additional studies are warranted to confirm its safety, efficacy and technical benefits, both for diagnosis of oncological and non-oncological disease and for endobronchial treatment of inoperable patients.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/patologia , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/patologia , Masculino
13.
J Radiol Prot ; 41(4)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-33827064

RESUMO

The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10-150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1-10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.


Assuntos
Cristalino , Exposição Ocupacional , Humanos , Método de Monte Carlo , Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação , Radiologia Intervencionista
14.
Sci Rep ; 10(1): 21693, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33303795

RESUMO

The current framework of radiological protection of occupational exposed medical workers reduced the eye-lens equivalent dose limit from 150 to 20 mSv per year requiring an accurate dosimetric evaluation and an increase understanding of radiation induced effects on Lens cells considering the typical scenario of occupational exposed medical operators. Indeed, it is widely accepted that genomic damage of Lens epithelial cells (LEC) is a key mechanism of cataractogenesis. However, the relationship between apoptosis and cataractogenesis is still controversial. In this study biological and physical data are combined to improve the understanding of radiation induced effects on LEC. To characterize the occupational exposure of medical workers during angiographic procedures an INNOVA 4100 (General Electric Healthcare) equipment was used (scenario A). Additional experiments were conducted using a research tube (scenario B). For both scenarios, the frequencies of binucleated cells, micronuclei, p21-positive cells were assessed with different doses and dose rates. A Monte-Carlo study was conducted using a model for the photon generation with the X-ray tubes and with the Petri dishes considering the two different scenarios (A and B) to reproduce the experimental conditions and validate the irradiation setups to the cells. The simulation results have been tallied using the Monte Carlo code MCNP6. The spectral characteristics of the different X-ray beams have been estimated. All irradiated samples showed frequencies of micronuclei and p21-positive cells higher than the unirradiated controls. Differences in frequencies increased with the delivered dose measured with Gafchromic films XR-RV3. The spectrum incident on eye lens and Petri, as estimated with MCNP6, was in good agreement in the scenario A (confirming the experimental setup), while the mean energy spectrum was higher in the scenario B. Nevertheless, the response of LEC seemed mainly related to the measured absorbed dose. No effects on viability were detected. Our results support the hypothesis that apoptosis is not responsible for cataract induced by low doses of X-ray (i.e. 25 mGy) while the induction of transient p21 may interfere with the disassembly of the nuclear envelop in differentiating LEC, leading to cataract formation. Further studies are needed to better clarify the relationship we suggested between DNA damage, transient p21 induction and the inability of LEC enucleation.


Assuntos
Catarata/etiologia , Dano ao DNA/efeitos da radiação , Células Epiteliais/patologia , Células Epiteliais/efeitos da radiação , Cristalino/citologia , Cristalino/efeitos da radiação , Exposição Ocupacional/efeitos adversos , Doses de Radiação , Raios X/efeitos adversos , Células Cultivadas , Humanos , Método de Monte Carlo
15.
Oncotarget ; 11(44): 3972-3983, 2020 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-33216834

RESUMO

There is a growing interest in the antibody-based delivery of cytokines to the tumor environment as a means to boost the anti-cancer activity of tumor-resident T cells and NK cells. Here, we describe the expression and characterization of fusion proteins, featuring the L19 antibody (specific to the alternatively-spliced EDB domain of fibronectin) and an engineered cytokine with interleukin-2 and interleukin-15 properties. The cytokine moiety was fused either at the N-terminal or at the C-terminal extremity and both fusion proteins showed a selective tumor accumulation in a quantitative biodistribution experiment. The N-terminal fusion inhibited tumor growth in immunocompetent mice bearing F9 carcinomas or WEHI-164 sarcomas when used as single agent. The anticancer activity was compared to the one of the same cytokine payload used as recombinant protein or fused to an anti-hen egg lysozyme antibody, serving as negative control of irrelevant specificity in the mouse. These results indicate that the antibody-based delivery of engineered cytokines to the tumor neovasculature may mediate a potent anticancer activity.

16.
Comput Methods Programs Biomed ; 185: 105153, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31678792

RESUMO

BACKGROUND AND OBJECTIVES: Malignant lymphomas are cancers of the immune system and are characterized by enlarged lymph nodes that typically spread across many different sites. Many different histological subtypes exist, whose diagnosis is typically based on sampling (biopsy) of a single tumor site, whereas total body examinations with computed tomography and positron emission tomography, though not diagnostic, are able to provide a comprehensive picture of the patient. In this work, we exploit a data-driven approach based on multiple-instance learning algorithms and texture analysis features extracted from positron emission tomography, to predict differential diagnosis of the main malignant lymphomas subtypes. METHODS: We exploit a multiple-instance learning setting where support vector machines and random forests are used as classifiers both at the level of single VOIs (instances) and at the level of patients (bags). We present results on two datasets comprising patients that suffer from four different types of malignant lymphomas, namely diffuse large B cell lymphoma, follicular lymphoma, Hodgkin's lymphoma, and mantle cell lymphoma. RESULTS: Despite the complexity of the task, experimental results show that, with sufficient data samples, some cancer subtypes, such as the Hodgkin's lymphoma, can be identified from texture information: in particular, we achieve a 97.0% of sensitivity (recall) and a 94.1% of predictive positive value (precision) on a dataset that consists in 60 patients. CONCLUSIONS: The presented study indicates that texture analysis features extracted from positron emission tomography, combined with multiple-instance machine learning algorithms, can be discriminating for different malignant lymphomas subtypes.


Assuntos
Linfoma/classificação , Aprendizado de Máquina , Algoritmos , Conjuntos de Dados como Assunto , Humanos , Linfoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Sensibilidade e Especificidade , Máquina de Vetores de Suporte , Tomografia Computadorizada por Raios X/métodos
17.
N Biotechnol ; 56: 38-45, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-31731038

RESUMO

Wheat bran could be utilised as feedstock for innovative and sustainable biorefinery processes. Here, an enzymatic hydrolysis process for ferulic acid (FA) extraction was optimised step by step for total wheat bran (Tritello) and then also applied to the outer bran layer (Bran 1). Proteins, reducing sugars, total phenols and FA were quantified. The highest FA yields (0.82-1.05 g/kg bran) were obtained either by rehydrating the bran by autoclaving (Tritello) or by steam explosion (Bran 1) using a bran/water ratio of 1:20, followed by enzymatic pre-treatment with Alcalase and Termamyl, to remove protein and sugars, and a final enzymatic hydrolysis with Pentopan and feruloyl esterase to solubilise phenol. FA was recovered from the final digestate via solid phase extraction. A 40-fold scale-up was also performed and the release of compounds along all the process steps and at increasing incubation times was monitored. Results showed that FA was initially present at a minimum level while it was specifically released during the enzymatic treatment. In the final optimized process, the FA extraction yield was higher than that obtained with NaOH control hydrolysis while, in comparison with other FA enzymatic extraction methods, fewer process steps were required and no buffers, strong acid/alkali nor toxic compounds were used. Furthermore, the proposed process may be easily scaled-up, confirming the feasibility of wheat bran valorisation by biorefinery processes to obtain valuable compounds having several areas of potential industrial exploitation.


Assuntos
Ácidos Cumáricos/isolamento & purificação , Fibras na Dieta/metabolismo , Subtilisinas/metabolismo , alfa-Amilases/metabolismo , Ácidos Cumáricos/química , Ácidos Cumáricos/metabolismo , Hidrólise
18.
Phys Med Biol ; 64(9): 095002, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30921779

RESUMO

The aim of the study is to use the well-known channelized Hotelling observer model (CHO) to characterize a recently installed angiography system (GE Discovery IGS 740) using sets of images of a contrast-detail phantom acquired with clinical protocols. A Leeds TO10 phantom was used. The phantom has 108 details: 12 diameters (size range: 0.25 mm-11 mm), each with nine contrasts (declared range: 0.012-0.930 at 70 kVp 1.00 with 1 mm Cu filtration). TO10 has been imaged between two 10 cm thick homogeneous solid water slabs. Two FOVs (32 cm and 20 cm) were used. Fluoroscopy images were taken using an abdominal protocol at two different frame rates (15 fps and 7.5 fps) and at two dose levels (low and normal); cineangiography images were acquired using an abdominal protocol at 15 fps at two dose levels (low and normal). A 40 Gabor channels CHO with internal noise was used. Human observers' studies were carried out to tune the internal noise parameter and to validate the model observer. Contrast-detail curves were obtained from the CHO output using a visibility threshold of 75% and fitted with Rose's model theory in order to characterize the angiography system. Wilcoxon rank-sum tests were performed to investigate possible differences among the different sets of images. The CHO can distinguish between the two dose levels (p -values < 0.002), while FOV and frame rate do not affect the contrast-detail curves significantly. It is important to note that the CHO does not find statistically significant differences between a fluoroscopy with FOV = 20 cm at normal dose level (17.6 mGy min-1) and a cineangiography with FOV = 32 cm low dose level (42.1 mGy min-1). This result can lead to a dose reduction of about 70% for our specific task (i.e. a static, disc shaped object at known location in homogeneous field). Given their stability in comparison to human observers, model observers provide an effective tool for image quality evaluation.


Assuntos
Angiografia/instrumentação , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Humanos , Variações Dependentes do Observador
19.
Eur Radiol ; 29(7): 3802-3811, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30737568

RESUMO

OBJECTIVES: Tomosynthesis (DBT) has proven to be more sensitive than digital mammography, but it requires longer reading time. We retrospectively compared accuracy and reading times of a simplified protocol with 1-cm-thick slabs versus a standard protocol of slabs + 1-mm-spaced planes, both integrated with synthetic 2D. METHODS: We randomly selected 894 DBTs (including 12 cancers) from the experimental arm of the RETomo trial. DBTs were read by two radiologists to estimate specificity. A second set of 24 cancers (8 also present in the first set) mixed within 276 negative DBTs was read by two radiologists. In total, 28 cancers with 64 readings were used to estimate sensitivity. Radiologists read with both protocols separated by a 3-month washout. Only women that were positive at the screening reading were assessed. Variance was estimated taking into account repeated measures. RESULTS: Sensitivity was 82.8% (53/64, 95% confidence interval (95% CI) 67.2-92.2) and 90.6% (95% CI 80.2-95.8) with simplified and standard protocols, respectively. In the random screening setting, specificity was 97.9% (1727/1764, 95% CI 97.1-98.5) and 96.3% (95% CI 95.3-97.1), respectively. Inter-reader agreement was 0.68 and 0.54 with simplified and standard protocols, respectively. Median reading times with simplified protocol were 20% to 30% shorter than with standard protocol. CONCLUSIONS: A simplified protocol reduced reading time and false positives but may have a negative impact on sensitivity. KEY POINTS: • The adoption of digital breast tomosynthesis (DBT) in screening, more sensitive than mammography, could be limited by its potential effect on the radiologists' workload, i.e., increased reading time and fatigue. • A DBT simplified protocol with slab only, compared to a standard protocol (slab plus planes) both integrated with synthetic 2D, reduced time and false positives but had a negative impact on sensitivity.


Assuntos
Neoplasias da Mama/diagnóstico , Carcinoma Intraductal não Infiltrante/diagnóstico , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/métodos , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Phys Med Biol ; 63(16): 165020, 2018 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-29972144

RESUMO

We present a comparison between full field digital mammography and synthetic mammography, performed on several mammography systems from four different manufacturers. The analysis is carried out on both the digital and synthetic images of two commercially available mammography phantoms, and focuses on a set of objective metrics that encode the geometrical appearance of imaging features of diagnostic interest. In particular, we measured sizes and contrasts of several clusters of microcalcification specks, shapes and contrasts of circular masses, and the power spectrum of background regions mimicking the heterogeneous texture of the breast parenchyma. Despite the potential issues of tomosynthesis in terms of image blurring, the synthetic images do not highlight any globally significant differences in the rendering of the details of interest, when compared to the original digital mammograms: relative contrasts are generally preserved, as well as the geometry of broad structures. We conclude that, as far as the considered objective metrics are concerned, the image quality of synthetic mammography does not exhibit significant differences with respect to the one of full field digital mammography, for all the considered systems.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Mamografia/normas , Imagens de Fantasmas , Controle de Qualidade , Feminino , Humanos , Intensificação de Imagem Radiográfica/métodos