Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39297889

RESUMO

PURPOSE: Over the past two decades, lamellar keratoplasty procedures, such as Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) and Descemet's Membrane Endothelial Keratoplasty (DMEK) as well as Deep Anterior Lamellar Keratoplasty (DALK), have become an integral part of clinical practice. With advances in contact lens fitting for keratoconus management and the implementation of UVA-Riboflavin Crosslinking (CXL), the landscape of keratoplasty indications is undergoing changes. Procedures and indications in a single tertiary care center over the past two decades are reviewed in this retrospective analysis. METHODS: Retrospective analysis utilized anonymized electronic data from the LIONS cornea bank Baden-Württemberg, Eye Center Freiburg, spanning from beginning of 2004 to end of 2023. The primary focus was on surgical procedures and indications for keratoplasty. RESULTS: The study encompassed a comprehensive analysis of 7130 corneal transplants. Penetrating keratoplasty (PK) exhibited a significant decline from 95% (n = 206, 2004) to 11% (n = 46, 2023), while DMEK increased from 48% (n = 157, 2012) to 82% (n = 347, 2023). Fuchs endothelial dystrophy (FED) emerged as the dominant indication, witnessing a significant increase from 24% (2004, n = 39) to 72% (2023, n = 288). Conversely, keratoconus (KC) showed a reciprocal change from 25% (2004, n = 40) to 4% (2023, n = 17). PK demonstrated a noteworthy indication shift in descending order from Bullous Keratopathy (BK), FED, and KC in 2004 to KC, graft failure, corneal scars, and ulcers in 2023. Repeat keratoplasty following DMEK remained rare, but a discernible upward trend was observed for PK. CONCLUSION: This retrospective analysis highlights significant changes in both keratoplasty indications and techniques over the past two decades. DMEK has emerged as a successful intervention for treating endothelial diseases, while PK retains its qualitative indispensability for a wide range of indications. Modern corneal banks are urged to maintain a robust supply of grafts for all surgical techniques in anticipation of potential increased demand in the future, particularly for repeat keratoplasties. KEY MESSAGES: What is known • Over the past two decades, lamellar keratoplasty procedures such as DSAEK and DMEK have increasingly replaced penetrating keratoplasty (PK) in clinical practice due to their improved outcomes and reduced complications for certain indications. New Findings • Our study reveals a significant shift in keratoplasty indications, with Fuchs endothelial dystrophy (FED) emerging as the predominant indication, increasing from 24% in 2004 to 72% in 2023, while keratoconus (KC) declined from 25 to 4% during the same period. • Penetrating keratoplasty (PK) has shown a marked decline in use, dropping from 95% of keratoplasties in 2004 to 11% in 2023, whereas DMEK has grown to represent 82% of procedures in 2023. • Despite the rise of DMEK, PK remains vital for a broad spectrum of indications, highlighting the necessity for corneal banks to maintain a versatile supply of grafts to meet diverse clinical needs, particularly in cases of repeat keratoplasties.

2.
Klin Monbl Augenheilkd ; 241(6): 734-740, 2024 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38574759

RESUMO

Endothelial cell density (ECD) is a crucial parameter for the release of corneal grafts for transplantation. The Lions Eye Bank of Baden-Württemberg uses the "Rhine-Tec Endothelial Analysis System" for ECD quantification, which is based on a fixed counting frame method considering only a small sample of 15 to 40 endothelial cells. The measurement result therefore depends on the frame placement and manual correction of the cells counted within the frame. To increase the sample size and create higher objectivity, we developed a new method based on "deep learning" that automatically detects all visible endothelial cells in the image. This study aims to compare this new method with the conventional Rhine-Tec system. 9375 archived phase-contrast microscopic images of consecutive grafts from the Lions Eye Bank were evaluated with the deep learning method and compared with the corresponding archived analyses of the Rhine-Tec system. Means, Bland-Altman and correlation analyses were compared. Comparable results were obtained for both methods. The mean difference between the Rhine-Tec system and the deep learning method was only - 23 cells/mm2 (95% confidence interval - 29 to - 17). There was a statistically significant positive correlation between the two methods, with a correlation coefficient of 0.748. What was striking in the Bland-Altman analysis were clustered deviations in the cell density range between 2000 and 2500 cells/mm2 - with higher values in the Rhine-Tec system. The comparable results for cell density measurement values underline the validity of the deep learning-based method. The deviations around the formal threshold for graft release of 2000 cells/mm2 are most likely explained by the higher objectivity of the deep learning method and the fact that measurement frames and manual corrections were specifically selected to reach the formal threshold of 2000 cells/mm2 when the full area endothelial quality was good. This full area assessment of the graft endothelium cannot currently be replaced by deep learning methods and remains the most important basis for graft release for keratoplasty.


Assuntos
Inteligência Artificial , Aprendizado Profundo , Endotélio Corneano , Bancos de Olhos , Bancos de Olhos/métodos , Contagem de Células/métodos , Humanos , Endotélio Corneano/citologia , Controle de Qualidade , Transplante de Córnea/métodos , Microscopia de Contraste de Fase/métodos
3.
Dtsch Arztebl Int ; 119(40): 669-674, 2022 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-35912449

RESUMO

BACKGROUND: Millions of people in Germany wear contact lenses every day. Deficient contact lens hygiene can lead to corneal infection. Contact lens-associated keratitis usually has a highly acute presentation and can cause long-term visual loss. METHODS: This review is based on pertinent publications retrieved by a selective search in PubMed, as well as on relevant metaanalyses, Cochrane reviews, and reports by national and international health care authorities. RESULTS: 23-94% of contact lens wearers report associated discomfort and eye problems. The annual incidence of contact lens-associated keratitis is 2-4/10 000. It is due to bacteria in 90% of cases, and much less commonly to acanthamoebae and fungi. The pathogens generally arrive with the contact lens on the surface of the eye and can penetrate into the corneal tissue because the tear film under the lens is not swept away from the ocular surface by the eyelids, and corneal epithelial changes are often present as well. Corneal infiltration that is diagnosed early is often self-limited, but advanced bacterial infection usually requires intense topical antibiotic treatment. Some severe infections can only be eradicated by emergency corneal transplantation; this is the case in 20-30 % of fungal and acanthamoebic infections. CONCLUSION: The wearing of contact lenses, particularly soft ones, is associated with a risk of microbial keratitis if proper contact lens hygiene is not exercised. Contact lens-associated keratitis very rarely causes permanent damage to eyesight (0.6 cases per 10 000 contact lens wearers per year). The use of contact lenses always calls for meticulous care.


Assuntos
Lentes de Contato , Doenças da Córnea , Úlcera da Córnea , Ceratite , Humanos , Úlcera da Córnea/etiologia , Úlcera da Córnea/microbiologia , Ceratite/epidemiologia , Ceratite/etiologia , Ceratite/terapia , Lentes de Contato/efeitos adversos , Córnea
4.
Klin Monbl Augenheilkd ; 237(11): 1326-1333, 2020 Nov.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-32869245

RESUMO

BACKGROUND: The demographic change in Germany will lead to an increase in irreversible age-related eye diseases. This will increase the need for specialised care facilities for visually impaired people. Due to reduced mobility, residents in such facilities often do not receive adequate ophthalmological care. New concepts must therefore be considered for this group of patients. One approach is to set up an ophthalmological examination unit within the facility combined with regular visits by an ophthalmologist. We now present the experience with such a model in a home for the blind. PATIENTS AND METHODS: The project was initiated in 2009. Since then there have been visits by medical staff of the Eye Center at Medical Center, University of Freiburg, every two weeks. All patient records (2010 - 2017) were reviewed systematically. The following data were extracted in a structured and anonymous way: Age at first presentation, gender, ophthalmological diagnoses and if a therapy was initiated. This data set was finally analysed descriptively. RESULTS: Out of 130 residents aged between 48 and 100 years, half were between 78 and 90 years old. The youngest resident was 48, the oldest 100 years old. The median visual acuity was 0.2. Sixty percent of the residents had at least mild visual impairment according to the WHO (visual acuity < 0.5; category 1 - 6). In one of 6 - 7 residents, visual acuity could not be determined using Snellen charts. The most frequent ophthalmological diagnoses included cataract (44%), age-related macular degeneration (36%) and glaucoma (29%). In 67 residents (52%), the ophthalmological examination lead to treatment, such as application of local therapy or planning an operation. CONCLUSION: In every second resident, the ophthalmologist's visit lead to treatment during the observation period. This underlines the difficulty of providing ophthalmological care even in specialised institutions for the blind and visually impaired, which is possibly due to the residents' mobility problems. The concept presented here has established a low-threshold, sustainable and high-quality ophthalmological service on site. These positive experiences indicate that corresponding measures may also be useful for other locations. However, in order to implement such a project on a larger scale, suitable financing and accounting modalities for the construction measures, the nursing staff and the ophthalmological procedure still need to be developed.


Assuntos
Instituição de Longa Permanência para Idosos , Casas de Saúde , Idoso , Idoso de 80 Anos ou mais , Cegueira/diagnóstico , Cegueira/epidemiologia , Cegueira/terapia , Alemanha/epidemiologia , Humanos , Pessoa de Meia-Idade , Transtornos da Visão/diagnóstico , Transtornos da Visão/epidemiologia , Transtornos da Visão/terapia
5.
Mol Vis ; 22: 1248-1255, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27777504

RESUMO

PURPOSE: To evaluate the feasibility of anterior segment spectral domain optic coherence tomography (ASOCT) as rejection readout in a keratoplasty mouse model and to compare ASOCT against the current standard (i.e., a clinical score system). Furthermore, to compare both approaches with respect to intra- and inter-individual observer variability and to calculate a critical point that distinguishes between rejection and non-rejection in ASOCT analysis. METHODS: Allogeneic penetrating keratoplasties (PKs) were performed using C3H/He donor mice and BALB/c recipient mice; syngeneic transplantations served as controls using BALB/c donors and recipients. Corneal graft rejection was determined with a clinical score. ASOCT was used to determine the central thickness of the corneal grafts in the same animals. The rejection status was corroborated with histopathological examination. RESULTS: The median survival time (MST) of the corneal allografts in the wild-type BALB/c mice was 12 days. Allogeneic transplantation led to a 100% rejection rate, whereas signs of rejection after syngeneic transplantation appeared in up to 20% of the mice. Central corneal thickness (CCT) determination via customized software revealed a direct correlation with the clinical score. Receiver operating curve (ROC) analysis confirmed CCT as a valid surrogate for rejection. Calculation of the area under the curve (AUC) revealed a value of 0.88 with an optimal cut-off at 267 pixels. CONCLUSIONS: An increase in the CCT during acute allogeneic corneal graft rejection significantly correlated with the clinical surrogate parameter "corneal opacity." ASOCT not only generates source data, but also analysis of the ASOCT data shows lower readout variability and fewer interpreter variations than the clinical score commonly used to define the time point of graft rejection in mice.


Assuntos
Segmento Anterior do Olho/patologia , Modelos Animais de Doenças , Rejeição de Enxerto/diagnóstico , Ceratoplastia Penetrante , Tomografia de Coerência Óptica , Animais , Área Sob a Curva , Opacidade da Córnea/patologia , Paquimetria Corneana , Feminino , Rejeição de Enxerto/classificação , Sobrevivência de Enxerto/fisiologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C3H , Variações Dependentes do Observador , Curva ROC , Fatores de Tempo , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA