Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cataract Refract Surg ; 50(6): 550-557, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305328

RESUMO

PURPOSE: To compare corrected distance visual acuity (CDVA) outcomes of hyperopic laser in situ keratomileusis (LASIK) with a postoperative corneal steepness above vs below 49 diopters (D). SETTING: Care-Vision Laser Centers, Tel-Aviv, Israel. DESIGN: Retrospective study. METHODS: This study included consecutive patients who underwent hyperopic LASIK between January 2013 and December 2019. Hyperopic patients were divided into 2 groups based on postoperative corneal steepness with steep corneas defined >49.0 D and the control group ≤49.0 D. Adjustments were performed to account for differences in baseline and intraoperative parameters. RESULTS: Overall, 1703 eyes of 1703 patients were included. Mean age was 48.3 ± 10.0 years, and 45.3% were male. Preoperatively, the steep group (2.4%, n = 41/1703) had steeper mean (44.6 D vs 43.1 D, P < .001) and steep (45.1 D vs 43.5 D, P < .001) keratometry, worse logMAR CDVA (0.07 vs 0.04, P = .02), and higher sphere (4.9 D vs 2.9 D, P < .001). Intraoperatively, they had a higher spherical treatment (4.6 D vs 2.8 D, P < .001). After hyperopic LASIK, the steep group had worse logMAR CDVA (0.10 vs 0.06, P = .01). However, after accounting for differences in baseline and spherical treatment, no significant differences were found in postoperative logMAR CDVA (0.06 vs 0.06, P = .99). The factors that remained associated with worse postoperative CDVA were higher spherical treatment (0.01 logMAR per 1 D, P < .001) and preoperative CDVA (0.60 logMAR per 1.00 logMAR, P < .001). CONCLUSIONS: Postoperative corneal steepness greater than 49 D is not associated with worse visual outcomes after hyperopic LASIK. However, lower preoperative visual potential and higher spherical treatment applied are associated with worse outcomes. The 49 D cutoff should be revisited.


Assuntos
Córnea , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Hiperopia/cirurgia , Hiperopia/fisiopatologia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Pessoa de Meia-Idade , Masculino , Feminino , Córnea/fisiopatologia , Lasers de Excimer/uso terapêutico , Refração Ocular/fisiologia , Adulto , Período Pós-Operatório , Topografia da Córnea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...