Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
3.
J Indian Assoc Pediatr Surg ; 24(1): 4-14, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30686881

RESUMO

The need for successful management of posterior urethral valves always captivates the minds of pediatric surgeons. Its success, however, depends on several factors ranging from prenatal preservation of upper tracts to postoperative pharmacological compliance. Regardless of measures available, some cases do not respond and progress to end stage. The management depends on several issues ranging from age and severity at presentation to long-term follow-up and prevention of secondary renal damage and managing valve bladder syndrome. This article is based on a consensus to the set of questionnaires, prepared by research section of Indian Association of Paediatric Surgeons and discussed by experienced pediatric surgeons based in different institutions in the country. Standard operating procedures for conducting a voiding cystourethrogram and cystoscopy were formulated. Age-wise contrast dosage was calculated for ready reference. Current evidence from literature was also reviewed and included to complete the topic.

4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-822787

RESUMO

@#The object of this study was to identify patients with diagnosed dengue infection, who were positive for both dengue-specific NS1 antigen and IgM antibody.

5.
Rev Sci Instrum ; 88(5): 053113, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28571414

RESUMO

Absorption spectroscopy on CO2 for the determination of gas temperature is reported. Direct absorption of a frequency comb laser through a gas cell at atmospheric conditions is analysed with a virtually imaged phased array spectrometer. Several measurement and analysis techniques are investigated to find the parameters most sensitive to changes in the temperature. Some of these show qualitative agreement with theoretical predictions where the trend is similar to the calculated values.

6.
Rev Sci Instrum ; 87(9): 093107, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782597

RESUMO

In this work we present a design of an external optical cavity based on Fabry-Perot etalons applied to a 100 MHz Er-doped fiber optical frequency comb working at 1560 nm to increase its repetition frequency. A Fabry-Perot cavity is constructed based on a transportable cage system with two silver mirrors in plano-concave geometry including the mode-matching lenses, fiber coupled collimation package and detection unit. The system enables full 3D angle mirror tilting and x-y off axis movement as well as distance between the mirrors. We demonstrate the increase of repetition frequency by direct measurement of the beat frequency and spectrally by using the virtually imaged phased array images.

7.
J Breath Res ; 10(2): 026003, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27058305

RESUMO

Exhaled breath analysis is a potential non-invasive tool for diagnosing and monitoring airway diseases. Gas chromatography-mass spectrometry and electrochemical sensor arrays are the main techniques to detect volatile organic compounds (VOC) in exhaled breath. We developed a broadband quantum cascade laser spectroscopy technique for VOC detection and identification. The objective of this study was to assess the repeatability of exhaled breath profiling with broadband quantum cascade laser-based spectroscopy and to explore the clinical applicability by comparing exhaled breath samples from healthy children with those from children with asthma or cystic fibrosis (CF). Healthy children and children with stable asthma or stable CF, aged 6-18 years, were included. Two to four exhaled breath samples were collected in Tedlar bags and analyzed by quantum cascade laser spectroscopy to detect VOCs with an absorption profile in the wavenumber region between 832 and 1262.55 cm(-1). We included 35 healthy children, 39 children with asthma and 15 with CF. Exhaled breath VOC profiles showed poor repeatability (Spearman's rho = 0.36 to 0.46) and agreement of the complete profiles. However, we were able to discriminate healthy children from children with stable asthma or stable CF and identified VOCs that were responsible for this discrimination. Broadband quantum cascade laser-based spectroscopy detected differences in VOC profiles in exhaled breath samples between healthy children and children with asthma or CF. The combination of a relatively easy and fast method and the possibility of molecule identification makes broadband quantum cascade laser-based spectroscopy attractive to investigate the diagnostic and prognostic potential of volatiles in exhaled breath.


Assuntos
Asma/diagnóstico , Testes Respiratórios/métodos , Fibrose Cística/diagnóstico , Análise Espectral/métodos , Adolescente , Criança , Expiração , Feminino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Lasers Semicondutores , Masculino , Compostos Orgânicos Voláteis/análise
8.
Indian J Med Microbiol ; 34(2): 213-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27080776

RESUMO

BACKGROUND: Chikungunya virus has recently re-emerged in India. OBJECTIVES: Assess prevalence of Chikungunya. MATERIALS AND METHODS: Study conducted from April 2011 to September 2011. Two hundred and six patients (206) of both sexes (100 males and 106 females) of all age groups studied. Serum separated and CHIKV MAC IgM ELISA and Hemagglutination inhibition assay done. RESULTS: 76 cases (36.89%) sero-positive by both the methods. CONCLUSION: Re-emergence and resurgence of the Chikungunya virus requires continuous monitoring.


Assuntos
Febre de Chikungunya/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/sangue , Criança , Pré-Escolar , Estudos Transversais , Ensaio de Imunoadsorção Enzimática , Feminino , Testes de Inibição da Hemaglutinação , Humanos , Imunoglobulina M/sangue , Índia/epidemiologia , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Prevalência , Soro/imunologia , Adulto Jovem
9.
Biomed Opt Express ; 6(10): 4037-50, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26504652

RESUMO

A preliminary comparative measurement between particle imaging velocimetry (PIV) and laser speckle contrast analysis (LASCA) to study pulsatile flow using ventricular assist device in a patient-specific carotid artery phantom is reported. These full-field optical techniques have both been used to study flow and extract complementary parameters. We use the high spatial resolution of PIV to generate a full velocity map of the flow field and the high temporal resolution of LASCA to extract the detailed frequency spectrum of the fluid pulses. Using this combination of techniques a complete study of complex pulsatile flow in an intricate flow network can be studied.

11.
Opt Express ; 22(15): 18299-309, 2014 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-25089450

RESUMO

We present a broadband quantum cascade laser-based spectroscopic system covering the region between 850 and 1250 cm(-1). Its robust multipass cavity ensures a constant interaction length over the entire spectral region. The device enables the detection and identification of numerous molecules present in a complex gas mixture without any pre-treatment in two minutes. We demonstrate that we can detect sub-ppmv concentration of acetone in presence of 2% of water at the same wavenumber region.

12.
Biomed Opt Express ; 5(7): 2145-56, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25071955

RESUMO

Continuous health monitoring has become a major theme of our aging society. Portable devices play an important role here. Many optical portable devices are susceptible to motion induced artifacts. We have performed an experimental study for detection of fluid pulsation based on multi-exposure speckle images, in presence of motion induced artifacts. Induced motion of a wide range of frequencies and amplitudes were generated to resemble sensor motion with respect to skin. The data was analyzed using speckle contrast and correlation. We concluded that both techniques have their own advantages, depending on the measurement configuration. A study of angles between illumination and detection revealed that larger angles yields better signal. Shorter exposure time was more successful in extracting the signal. We also performed in-vivo measurements that agree with the in-vitro case. We also show that a minimum collection of two pixels from the speckle image is sufficient to extract relevant results.

13.
Indian J Med Microbiol ; 32(3): 277-80, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25008820

RESUMO

PURPOSE: To find out the most suitable serological investigative procedures to diagnose dengue cases effectively in the laboratory practice identifying primary and secondary cases as well as period of suffering. MATERIALS AND METHODS: Dengue suspected cases sent to the laboratory in 2012 in central Kolkata by the local physicians were categorised into seven panels according to the investigations asked for such as (1) only dengue-specific NS1 antigen (2) only IgM antibodies, (3) NS1+IgM+IgG antibodies, (4) only IgM and IgG, (5) NS1+IgM, (6) NS1+IgG and (7) only IgG. RESULTS: Out of 1892 suspected cases, dengue was diagnosed in 725 (38.3%). Through panels I, II, III, IV, V, VI and VII, it was possible to diagnose dengue in (I) 35.98% (435/1209), (II) 37.5% (24/60), (III) 49% (173/354), (IV) 30.8% (68/221), (V) 60.5% (23/38), (VI) 40% (2/5) and (VII) 0 of cases respectively. Detail information such as confirmed diagnosis, duration of the disease (whether early or prolonged) and classification of primary and secondary dengue in such early or prolonged stages would only be possible in panel III, which information would be helpful for effective monitoring and treatment of dengue patients. In all other panels, merely fragmentary information would be obtained. CONCLUSIONS: Serodiagnostic tests dengue-specific NS1 antigen and IgM and IgG antibodies when conducted simultaneously would be able to diagnose confirmed dengue cases categorising primary and secondary dengue along with the duration of the disease, whether early or prolonged.


Assuntos
Anticorpos Antivirais/sangue , Antígenos Virais/sangue , Vírus da Dengue/imunologia , Dengue/diagnóstico , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Índia , Testes Sorológicos/métodos
14.
Opt Lett ; 38(24): 5334-7, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24322251

RESUMO

We have performed an in vitro and in vivo study, based on laser speckle contrast analysis, to detect fluid pulsation in the presence of artifacts caused by the relative motion between the sample and the illumination source. We observe that the pulsation signal is clearly detectable for a range of motion amplitudes and oscillation frequencies; however, for higher amplitudes and oscillation frequencies of motion, the signal, due to pulsation, becomes increasingly difficult to detect.


Assuntos
Artefatos , Hidrodinâmica , Lasers , Movimento (Física) , Dedos , Humanos
15.
Phys Rev Lett ; 108(18): 183901, 2012 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-22681076

RESUMO

We demonstrate a new technique for absolute distance measurement with a femtosecond frequency comb laser, based on unraveling the output of an interferometer to distinct comb modes with 1 GHz spacing. From the fringe patterns that are captured with a camera, a distance is derived by combining spectral and homodyne interferometry, exploiting about 9000 continuous wave lasers. This results in a measurement accuracy far within an optical fringe (λ/30), combined with a large range of nonambiguity (15 cm). Our technique merges multiwavelength interferometry and spectral interferometry, within a single scheme.

16.
Opt Express ; 19(7): 6549-62, 2011 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-21451683

RESUMO

We experimentally demonstrate long distance measurements with a femtosecond frequency comb laser using dispersive interferometry. The distance is derived from the unwrapped spectral phase of the dispersed interferometer output and the repetition frequency of the laser. For an interferometer length of 50 m this approach has been compared to an independent phase counting laser interferometer. The obtained mutual agreement is better than 1.5 µm (3×10(-8)), with a statistical averaging of less than 200 nm. Our experiments demonstrate that dispersive interferometry with a frequency comb laser is a powerful method for accurate and non-incremental measurement of long distances.


Assuntos
Algoritmos , Interferometria/instrumentação , Lasers , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
17.
Opt Express ; 19(4): 3406-17, 2011 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-21369163

RESUMO

We investigate general properties of the interferograms from a frequency comb laser in a non-linear dispersive medium. The focus is on interferograms at large delay distances and in particular on their broadening, the fringe formation and shape. It is observed that at large delay distances the interferograms spread linearly and that its shape is determined by the source spectral profile. It is also shown that each intensity point of the interferogram is formed by the contribution of one dominant stationary frequency. This stationary frequency is seen to vary as a function of the path length difference even within the interferogram. We also show that the contributing stationary frequency remains constant if the evolution of a particular fringe is followed in the successive interferograms found periodically at different path length differences. This can be used to measure very large distances in dispersive media.

20.
Indian J Physiol Pharmacol ; 53(1): 55-60, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19810577

RESUMO

A reliable and cost-effective animal model for human obesity with its manifested disorders is yet to be established in the context of increased morbidity and mortality due to obesity and its related problems. Therefore, an attempt was made to produce obesity in locally available British Angora Rabbits (BAR) and examine the effect on metabolic and cardiovascular parameters. Adult male BARs weighing nearly 2 kg were randomly divided into two groups, one of the groups was fed with high fat diet (HFD) ad libitum for 10 weeks and the control group received standard normal rabbit chow for same period. Body weight, skinfold thickness, serum cholesterol, serum glucose and resting heart rate were measured before and after the dietary regimens. After 10 weeks, HFD group of rabbits demonstrated significant (P < 0.05) increase in body weight (+24%) and skinfold thickness (+37%). The gain in body weight was positively correlated to skinfold thickness (r = 0.61). Serum cholesterol, serum glucose and resting heart rate were also increased by 46%, 52% and 15%, respectively. Whereas no such increases in any of these parameters were observed in control group of rabbits. Our results suggest that obesity can be produced in BARs by feeding HFD. The obesity manifests with cardiovascular and metabolic changes. It is proposed that this may serve as a valid and reliable model of experimental obesity.


Assuntos
Gorduras na Dieta/efeitos adversos , Modelos Animais de Doenças , Obesidade/etiologia , Animais , Glicemia/metabolismo , Peso Corporal/fisiologia , Colesterol/sangue , Frequência Cardíaca/fisiologia , Masculino , Obesidade/metabolismo , Obesidade/fisiopatologia , Coelhos , Dobras Cutâneas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...