Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 1727-1734, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38887510

RESUMO

Corneal transplantation, when used in the correct setting, can significantly improve visual acuity and therefore quality of life. One of the barriers to good vision following keratoplasty is residual post operative surgical astigmatism. Following a thorough literature search, we present the different options available to readers, with regards to how post-operative astigmatism can be approached and managed in order to improve vision. We present available data from the literature, which in some areas are scarce, with a view to collating all of this information in one place, allowing comparison between different modalities of treatment.

2.
Eye (Lond) ; 37(4): 644-649, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35277663

RESUMO

BACKGROUND/AIMS: To evaluate 1-year success rates and safety profile of Preserflo™ Microshunt in glaucoma patients. METHODS: Retrospective multicentre cohort study of 100 consecutive eyes (91 patients) from four tertiary-referral glaucoma centres. Four intraocular pressure (IOP) criteria were defined: A: IOP ≤ 21 mmHg+IOP reduction ≥20% from baseline; B: IOP ≤ 18 mmHg+IOP reduction ≥20%; C: IOP ≤ 15 mmHg+IOP reduction ≥25%; D: IOP≤12 mmHg+IOP reduction ≥30%. Success was defined as qualified or complete based on whether reached with or without medication. Primary outcome was success according to the above criteria. Secondary outcomes included: IOP, best-corrected visual acuity (BCVA), medication use, complications, postoperative interventions, and failure-associated factors. RESULTS: Qualified and complete success rates (95% CI) at 12 months were 74%(66-83%) and 58%(49-69%) for criterion A, 72%(63-82%) and 57%(48-68%) for B, 52%(43-63%) and 47%(38-58%) for C, 29%(21-40%) and 26%(19-36%) for D. Overall median (interquartile range (IQR)) preoperative IOP decreased from 21.5(19-28) mmHg to 13(11-16) mmHg at 12 months. BCVA was not significantly different up to 12 months (p = 0.79). Preoperative median (IQR) number of medications decreased from 3 (2-3) to 0 (0-1) at 12 months. Twelve eyes underwent needling, five surgical revision and one device removal due to corneal oedema. There were no hypotony-related complications. Non-Caucasian ethnicity was the only risk factor consistently associated with increased failure. CONCLUSIONS: Preserflo™ Microshunt is a viable surgical option in glaucoma patients, with reasonable short-term success rates, decreased medications use, excellent safety profile, smooth postoperative care, and rapid learning curve. Success rates for the most stringent IOP cutoffs were modest, indicating that it may not be the optimal surgery when very low target IOP is required.


Assuntos
Glaucoma , Hipotensão Ocular , Trabeculectomia , Humanos , Estudos de Coortes , Estudos Retrospectivos , Resultado do Tratamento , Glaucoma/cirurgia , Pressão Intraocular , Seguimentos
4.
Transl Vis Sci Technol ; 4(2): 16, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25938004

RESUMO

PURPOSE: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. METHODS: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). RESULTS: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). CONCLUSIONS: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. TRANSLATIONAL RELEVANCE: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...