Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aviat Space Environ Med ; 73(9): 925-30, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12234046

RESUMO

BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. HYPOTHESIS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.


Assuntos
Drenagem , Peritonite/cirurgia , Voo Espacial , Animais , Estudos de Viabilidade , Feminino , Suínos , Ultrassonografia , Ausência de Peso , Simulação de Ausência de Peso
2.
Stud Health Technol Inform ; 81: 106-12, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11317721

RESUMO

The NASA Space Medicine program is now developing plans for more extensive use of high-fidelity medical simulation systems. The use of simulation is seen as means to more effectively use the limited time available for astronaut medical training. Training systems should be adaptable for use in a variety of training environments, including classrooms or laboratories, space vehicle mockups, analog environments, and in microgravity. Modeling and simulation can also provide the space medicine development program a mechanism for evaluation of other medical technologies under operationally realistic conditions. Systems and procedures need preflight verification with ground-based testing. Traditionally, component testing has been accomplished, but practical means for "human in the loop" verification of patient care systems have been lacking. Medical modeling and simulation technology offer potential means to accomplish such validation work. Initial considerations in the development of functional requirements and design standards for simulation systems for space medicine are discussed.


Assuntos
Medicina Aeroespacial/educação , Simulação por Computador , Instrução por Computador , Interface Usuário-Computador , Currículo , Humanos , Estados Unidos , United States National Aeronautics and Space Administration
3.
Am Surg ; 67(3): 232-5; discussion 235-6, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11270880

RESUMO

Pneumothorax is commonly seen in trauma patients; the diagnosis is confirmed by radiography. The use of ultrasound where radiographic capabilities are absent, is being investigated by the National Aeronautics and Space Administration. We investigated the ability of ultrasound to assess the magnitude of pneumothorax in a porcine model. Sonography was performed on anesthetized pigs in both ground-based laboratory (n = 5) and microgravity conditions (0 x g) aboard the KC-135 aircraft during parabolic flight (n = 4). Aliquots of air (50-100 cm3) were introduced into the chest to simulate pneumothorax. Results were videorecorded and digitized for later interpretation. Several distinct sonographic patterns of partial lung sliding were noted including the combination of a sliding zone with a still zone and a "segmented" sliding zone. These "partial lung sliding" patterns exclude massive pneumothorax manifested by a complete separation of the lung from the parietal pleura. In 0 x g, the sonographic picture is more diverse; one x g differences between posterior and anterior aspects are diminished. Modest pneumothorax can be inferred by the ultrasound sign of "partial lung sliding." This finding, which increases the negative predictive value of thoracic ultrasound, may be attributed to intermittent pleural contact, small air spaces, or alterations in pleural lubricant. Further studies of these phenomena are warranted.


Assuntos
Modelos Animais de Doenças , Pneumotórax/classificação , Pneumotórax/diagnóstico por imagem , Índice de Gravidade de Doença , Ausência de Peso , Animais , Artefatos , Feminino , Pneumotórax/patologia , Pneumotórax Artificial/instrumentação , Pneumotórax Artificial/métodos , Valor Preditivo dos Testes , Suínos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/normas , Gravação de Videoteipe , Ausência de Peso/efeitos adversos
4.
J Trauma ; 50(2): 201-5, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11242282

RESUMO

BACKGROUND: Thoracic ultrasound may rapidly diagnose pneumothorax when radiographs are unobtainable; the accuracy is not known. METHODS: We prospectively evaluated thoracic ultrasound detection of pneumothorax in patients at high suspicion of pneumothorax. The presence of "lung sliding" or "comet tail" artifacts were determined in patients by ultrasound before radiologic verification of pneumothorax by residents instructed in thoracic ultrasound. Results were compared with standard radiography. RESULTS: There were 382 patients enrolled; the cause of injury was blunt (281 of 382), gunshot wound (22 of 382), stab wound (61 of 382), and spontaneous (18 of 382). Pneumothorax was demonstrated on chest radiograph in 39 patients and confirmed by ultrasound in 37 of 39 patients (95% sensitivity); two pneumothoraces could not be diagnosed because of subcutaneous air; the true-negative rate was 100%. CONCLUSION: Thoracic ultrasound reliably diagnoses pneumothorax. Expansion of the focused abdominal sonography for trauma (FAST) examination to include the thorax should be investigated for terrestrial and space medical applications.


Assuntos
Pneumotórax/diagnóstico por imagem , Traumatismos Torácicos/diagnóstico por imagem , Ferimentos não Penetrantes/diagnóstico por imagem , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia , Ferimentos por Arma de Fogo/diagnóstico por imagem , Ferimentos Perfurantes/diagnóstico por imagem
5.
Surg Endosc ; 15(12): 1413-8, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11965456

RESUMO

BACKGROUND: Performing a surgical procedure in weightlessness, also called 0-gravity (0-g), has been shown to be no more difficult than in a 1-g environment if the requirements for the restraint of the patient, operator, surgical hardware, are observed. The performance of laparoscopic and thorascopic procedures in weightlessness, if feasible, would offer several advantages over the performance of an open operation. Concerns about the feasibility of performing minimally invasive procedures in weightlessness have included impaired visualization from the absence of gravitational retraction of the bowel (laparoscopy) or thoracic organs (thoracoscopy) as well as obstruction and interference from floating debris such as blood, pus, and irrigation fluid. The purpose of this study was to determine the feasibility of performing laparoscopic and thorascopic procedures and the degree of impaired surgical endoscopic visualization in weightlessness. METHODS: From 1993 to 2000, laparoscopic and thorascopic procedures were performed on 10 anesthetized adult pigs weighing approximately 50 kg in the National Aeronautics and Space Administration (NASA) Microgravity Program using a modified KC-135 airplane. The parabolic simulation system for advanced life support was used in this project, and 20 to 40 parabolas were used for laparoscopic or thorascopic investigation, each containing approximately 30 s of 0-g alternating with 2-g pullouts. The animal model was restrained in the supine position on a floor-level Crew Medical Restraint System, and the abdominal cavity was insufflated with carbon dioxide. The intraabdominal and intrathoracic anatomy was visualized in the 1-g, 0-g, and 2-g periods of parabolic flight. Bleeding was created in the animals, and the behavior of the blood in the abdominal and thoracic cavities was observed. In the thoracic cavity, gas insufflation and mechanical retraction was used at times unilaterally to decrease pulmonary ventilation enough to increase the thoracic domain. RESULTS: Visualization was improved in laparoscopy, from tethering of the bowel by the elastic mesentery, and from the strong tendency for debris and blood to adhere to the abdominal wall because of surface tension forces. The lack of adequate thoracic domain made thorascopy more difficult. Fluid in the thoracic cavity did not impair visualization because the fluid at 0-g does not loculate posteriorly, but disperses along the thoracic wall and mediastinal reflections. CONCLUSIONS: Performing minimally invasive procedures instead of open surgical procedures in a weightless environment has theoretical advantages, especially in the ability to prevent cabin atmosphere contamination from surgical fluids (blood, pus, irrigation). Visualization will become more important and practical as the endoscopic hardware is miniaturized from its current form, as endoscopic technology becomes more advanced, and as more surgically capable medical crew officers are present in future long-duration space exploration missions.


Assuntos
Endoscopia/métodos , Animais , Laparoscópios , Laparoscopia/métodos , Voo Espacial , Suínos/cirurgia , Procedimentos Cirúrgicos Torácicos/métodos , Toracoscopia/métodos , Ausência de Peso/efeitos adversos , Simulação de Ausência de Peso/métodos
6.
Aviat Space Environ Med ; 71(11): 1120-5, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11086666

RESUMO

BACKGROUND: The National Aeronautics and Space Administration (NASA) has used iodination as a method of microbial disinfection of potable water systems in U.S. spacecraft and long-duration habitability modules. A review of thyroid function tests of NASA astronauts who had consumed iodinated water during spaceflight was conducted. METHODS: Thyroid function tests of all past and present astronauts were reviewed. Medical records of astronauts with a diagnosis of thyroid disease were reviewed. Iodine consumption by space crews from water and food was determined. Serum thyroid-stimulating hormone (TSH) and urinary iodine excretion from space crews were measured following modification of the Space Shuttle potable water system to remove most of the iodine. RESULTS: Mean TSH significantly increased in 134 astronauts who had consumed iodinated water during spaceflight. Serum TSH, and urine iodine levels of Space Shuttle crewmembers who flew following modification of the potable water supply system to remove iodine did not show a statistically significant change. There was no evidence supporting association between clinical thyroid disease and the number of spaceflights, amount of iodine consumed, or duration of iodine exposure. CONCLUSIONS: It is suggested that pharmacological doses of iodine consumed by astronauts transiently decrease thyroid function, as reflected by elevated serum TSH values. Although adverse effects of excess iodine consumption in susceptible individuals are well documented, exposure to high doses of iodine during spaceflight did not result in a statistically significant increase in long-term thyroid disease in the astronaut population.


Assuntos
Astronautas , Iodetos/efeitos adversos , Iodo/efeitos adversos , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Voo Espacial , Astronave , Doenças da Glândula Tireoide/induzido quimicamente , Tireotropina/sangue , Tireotropina/efeitos dos fármacos , Purificação da Água/métodos , Feminino , Humanos , Iodetos/análise , Iodo/análise , Iodo/urina , Masculino , Doenças Profissionais/sangue , Doenças Profissionais/classificação , Doenças Profissionais/urina , Exposição Ocupacional/análise , Estudos Prospectivos , Estudos Retrospectivos , Doenças da Glândula Tireoide/sangue , Doenças da Glândula Tireoide/classificação , Doenças da Glândula Tireoide/urina , Testes de Função Tireóidea , Fatores de Tempo , Estados Unidos , United States National Aeronautics and Space Administration
7.
Aviat Space Environ Med ; 71(6): 564-70, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10870814

RESUMO

BACKGROUND: Information has been collected regarding the immediate physiological effects of spaceflight on humans. However, little is yet known regarding long-term effects. The purpose of this paper is to describe the Longitudinal Study of Astronaut Health (LSAH) and report current mortality data. METHODS: All astronauts selected for the United States Space Program are followed from selection throughout their lifetime or until the end of the study. Comparisons are ground-based Johnson Space Center (JSC) employees matched to the astronauts at a 3:1 ratio by sex-specific age and body mass index. They are followed in the same manner as astronauts. Morbidity and mortality data are obtained from medical records supplemented with study questionnaires. Checks for death certificates are made to ascertain death of participants who miss routine examinations. RESULTS: Current cause-specific mortality rates for astronauts selected from 1959 through 1991 are not statistically different from rates for comparison participants for cardiovascular (p = 0.8112), cancer (p = 0.2382), or other disease (p = 0.5040) mortality. Astronauts have a significantly higher mortality rate due to accidents and injuries (p < 0.0001). CONCLUSIONS: Astronauts have a similar risk of death due to chronic diseases as ground-based participants, but are at greater risk for occupational-related accidental death.


Assuntos
Astronautas , Nível de Saúde , Projetos de Pesquisa , Voo Espacial , Doença Aguda , Adulto , Medicina Aeroespacial , Astronautas/estatística & dados numéricos , Causas de Morte , Doença Crônica , Feminino , Humanos , Estudos Longitudinais , Masculino , Análise por Pareamento , Morbidade , Mortalidade , Inquéritos e Questionários , Fatores de Tempo , Estados Unidos/epidemiologia
9.
Aviat Space Environ Med ; 70(7): 705-8, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10417009

RESUMO

We evaluated in-flight use of medications from astronaut debriefings after 79 U.S. Space Shuttle missions. From the 219 records obtained (each representing one person-flight), 94% included some medication being taken during flight; of that number, 47% were for space motion sickness, 45% for sleep disturbances, and smaller percentages for headache, backache, and sinus congestion. Drugs were taken most often orally, followed in decreasing order of frequency by intranasal, intramuscular, and rectal routes. Drugs for space motion sickness were taken mostly during the first 2 d of flight, drugs for pain during the first 4 d, and drugs for sleeplessness and sinus congestion were taken consistently for 9 flight days. About 85% of all doses had no reported side effects, and most of the side effects that were reported happened during the first mission day. About 80% of the drug-dose events were perceived effective by the recipients; most of the reports of ineffectiveness occurred during the first mission day. Promethazine, the only drug given by three different routes (orally, intramuscularly, and rectally), was most effective and had minimal side effects when taken intramuscularly. This information, although useful, should be expanded to include objective measures of effectiveness so that therapeutic efficacy can be assessed during flight.


Assuntos
Astronautas , Azia/tratamento farmacológico , Enjoo devido ao Movimento/tratamento farmacológico , Doenças Profissionais/tratamento farmacológico , Dor/tratamento farmacológico , Sinusite/tratamento farmacológico , Distúrbios do Início e da Manutenção do Sono/tratamento farmacológico , Voo Espacial , Relação Dose-Resposta a Droga , Uso de Medicamentos , Azia/etiologia , Humanos , Enjoo devido ao Movimento/etiologia , Doenças Profissionais/etiologia , Dor/etiologia , Sinusite/etiologia , Distúrbios do Início e da Manutenção do Sono/etiologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
Aviat Space Environ Med ; 69(2): 142-4, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9491253

RESUMO

BACKGROUND: The potential for occupational radiation exposures in the U.S. Space Program makes cancer risk a major health concern. METHODS: The NASA Medical Operations Branch and KRUG Life Sciences Epidemiology Section at the Johnson Space Center (JSC) investigated the rate of cancer mortality among the astronauts and the comparison participants of the Longitudinal Study of Astronaut Health (LSAH). Medical records are maintained by the JSC Flight Medicine Clinic, JSC Occupational Medicine Clinic, and LSAH. Cause of death data from death certificates were reviewed for cancer mortality. These data were compared with cancer mortality data for the general population residing in the Texas Gulf Coast area. RESULTS: The astronauts had a higher age-specific risk of cancer mortality than the comparison group (SMR = 345; 95% CI = 69.5-756.2), but the difference did not reach statistical significance. Both the astronauts and the comparison group had lower age-specific rates than the general population (SMR = 47, 95% CI = 9.6-105.1; SMR = 17, 95% CI = 3.5-37.9, respectively).


Assuntos
Neoplasias/mortalidade , Exposição Ocupacional , Radiação Ionizante , Voo Espacial , Adulto , Fatores Etários , Causas de Morte , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fatores de Risco
11.
Mayo Clin Proc ; 72(4): 301-8, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9121174

RESUMO

OBJECTIVE: To develop techniques for conducting a physical examination in microgravity and to describe and document the physiologic changes noted with use of a modified basic physical examination. DESIGN: On the basis of data gathered from physical examinations on KC-135 flights, three physical variables were assessed serially in astronauts during two shuttle missions (of 8- and 10-day duration, respectively). Preflight, in-flight, and postflight examinations were conducted by trained physician-astronauts or flight surgeons, who used this modified examination. MATERIAL AND METHODS: Five male and two female crewmembers participated in the "hands-on" physical examination of all physiologic systems except the genitourinary system. Level of edema, intensity of bowel sounds, and peripheral reflexes were assessed and graded. RESULTS: This investigation identified unique elements of a physical examination performed during space flight that will assist in the development of standard methods for conducting examinations of astronauts in weightlessness. In addition, demonstrable changes induced by microgravity were noted in most physiologic systems examined. CONCLUSION: The data support the hypothesis that the microgravity examination differs from that conducted on earth or in a 1g environment. In addition, alterations in the physiologic response can be detected with use of hands-on technique. These data are invaluable in the development of optimal medical care for humans in space.


Assuntos
Exame Físico , Voo Espacial , Ausência de Peso , Auscultação , Edema , Feminino , Humanos , Masculino , Palpação , Percussão , Exame Físico/métodos , Reflexo , Fatores de Tempo
12.
Aviat Space Environ Med ; 68(2): 151-8, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9125093

RESUMO

BACKGROUND: Doppler-detectable microbubbles (DMB) are frequently used to evaluate altitude decompression stress. However, the role of DMB in the therapy of decompression sickness (DCS) has not been examined. HYPOTHESIS: The ability of Doppler to detect microbubbles during decompression (Doppler test) may be used in the diagnosis of DCS, and to aid clinical decisions about treatment options for DCS. METHODS: We examined the data on DMB and symptoms from NASA Database on DCS (n = 516). The accuracy of Doppler test was obtained from the Receiver Operating Characteristic (ROC) for DMB (grades I through IV), and efficacy was obtained by calculating predictive or post-test probabilities. Threshold analysis was used to obtain the probabilities for testing and/or treatment decisions. RESULTS: The Doppler test was useful for both screening and confirming DCS, when different criteria (grade I for screening; grade IV for confirming) were used for a positive test. Calculation of predictive values and threshold analysis showed that: 1) early recompression was the therapy of choice when post-test probability of disease was > 0.25 in individuals with non-specific pain at altitude, and early recompression with 100% oxygen for 2 h at site level was optimal therapy when this probability was > 0.33; 2) hyperbaric therapy was optimal when post-test probability was > 0.04 in individuals with uncertain symptoms post-flight. CONCLUSIONS: The Doppler test was of greater utility in excluding DCS than confirming its presence, and was useful in making therapeutic decisions on DCS when confronted with non-specific symptoms at altitude.


Assuntos
Doença da Descompressão/diagnóstico , Fluxometria por Laser-Doppler/normas , Medicina Aeroespacial , Técnicas de Apoio para a Decisão , Doença da Descompressão/terapia , Humanos , Oxigenoterapia Hiperbárica , Funções Verossimilhança , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença
13.
Aviat Space Environ Med ; 67(11): 1080-5, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8908347

RESUMO

BACKGROUND: Previous studies of telemedicine applications have demonstrated that the technology is effective but inefficient. Little attention has been directed to the primary care portion of the connection, especially the use of the medical peripheral devices. This study used a telemedicine testbed that simulates a rural practice environment to describe the effectiveness and efficiency of the NASA Telemedicine Instrument Pack, a small self-contained system of medical peripheral devices. METHOD: This study was an 8-week field trial of a suitcase-sized pack containing a fundus camera, flexible nasopharyngoscope, dermatology macrolens, light source, and video monitor. The pack was first studied in specialty clinics and then was used in a family practice office connected to the consultant node by digital lines. Evaluations were obtained from technicians, patients, and consultants. RESULTS: During 20 video clinic sessions, 59 patients with 38 different diagnoses were examined. The ear, nose, and throat portion of the exam was effective, with some decrement in color and clarity with compression of the signal. The eye portion was marginally effective, limited by a field of view that was too narrow and also by rigorous technician requirements. The skin exam was largely unacceptable primarily because the macrolens did not meet the requirements for color or clarity prior to compression of the signal. CONCLUSIONS: Subsequent design efforts for medical peripheral devices for telemedicine use will require significant modifications to "off the shelf" equipment to be effective and efficient. A family practice telemedicine testbed provides the appropriate environment for such field trials.


Assuntos
Periféricos de Computador/normas , Medicina de Família e Comunidade/instrumentação , Exame Físico/instrumentação , Consulta Remota/instrumentação , Gravação em Vídeo/instrumentação , Atitude do Pessoal de Saúde , Dermatologia/instrumentação , Dermatologia/normas , Falha de Equipamento , Estudos de Avaliação como Assunto , Medicina de Família e Comunidade/normas , Humanos , Oftalmologia/instrumentação , Oftalmologia/normas , Otolaringologia/instrumentação , Otolaringologia/normas , Aceitação pelo Paciente de Cuidados de Saúde , Exame Físico/normas , Consulta Remota/normas , Serviços de Saúde Rural , Gravação em Vídeo/normas
14.
Aviat Space Environ Med ; 67(5): 467-73, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8725475

RESUMO

We conducted an opinion survey to improve the characterization of medical risk during spaceflight, using a questionnaire designed to elicit space medicine experts' perceptions of the probability, health effect, and mission impact of selected medical events occurring during spaceflight missions of 30-90 d. This questionnaire was directed toward those events about which little data currently exist, therefore medical events that have occurred during spaceflights with some frequency, such as space motion sickness, were excluded from the questionnaire. The questionnaire was mailed to 99 clinical and research professionals involved with NASA medical programs; 65 responses were returned, of which 60 could be analyzed. The experts rated skin disorders as the most likely to occur, but which would have little effect on mission completion or astronaut health. Circulatory diseases were rated as having the lowest probability of occurrence, but the highest effect on the mission or on a crewmember's health. The results of this survey will be combined with data from analogous populations and existing astronaut health data to establish a data set to support decisions about allocation of health care resources.


Assuntos
Doenças Profissionais/epidemiologia , Voo Espacial , Humanos , Medição de Risco , Inquéritos e Questionários
15.
Surg Endosc ; 10(2): 111-7, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8932610

RESUMO

BACKGROUND: Performing a surgical procedure in weightlessness has been shown not to be any more difficult than in a 1g environment if the requirements for the restraint of the patient, operator, and surgical hardware are observed. The feasibility of performing a laparoscopic surgical procedure in weightlessness, however, has been questionable. Concerns have included the impaired visualization from the lack of gravitational retraction of the bowel and from floating debris such as blood. METHODS: In this project, laparoscopic surgery was performed on a porcine animal model in the weightlessness of parabolic flight. RESULTS: Visualization was unaffected due to the tethering of the bowel by the elastic mesentery and the strong tendency for debris and blood to adhere to the abdominal wall due to surface tension forces. CONCLUSIONS: There are advantages to performing a laparoscopic instead of an open surgical procedure in a weightless environment. These will become important as the laparoscopic support hardware is miniaturized from its present form, as laparoscopic technology becomes more advanced, and as more surgically capable crew medical officers are present in future long-duration space-exploration missions.


Assuntos
Medicina Aeroespacial/métodos , Laparoscopia , Ausência de Peso , Abdome/anatomia & histologia , Medicina Aeroespacial/instrumentação , Animais , Modelos Animais de Doenças , Laparoscopia/métodos , Pelve/anatomia & histologia , Voo Espacial , Suínos
17.
Surg Gynecol Obstet ; 177(2): 121-5, 1993 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8342090

RESUMO

A surgical procedure performed during space flight would occur in a unique microgravity environment. Several experiments performed during weightlessness in parabolic flight were reviewed to ascertain the behavior of surgical bleeding in microgravity. Simulations of bleeding using dyed fluid and citrated bovine blood, as well as actual arterial and venous bleeding in rabbits, were examined. The high surface tension property of blood promotes the formation of large fluid domes, which have a tendency to adhere to the wound. The use of sponges and suction will be adequate to prevent cabin atmosphere contamination with all bleeding, with the exception of temporary arterial droplet streams. The control of the bleeding with standard surgical techniques should not be difficult.


Assuntos
Perda Sanguínea Cirúrgica , Voo Espacial , Ausência de Peso , Animais , Bovinos , Modelos Estruturais , Coelhos
18.
Aviat Space Environ Med ; 64(1): 58-62, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8424742

RESUMO

The first surgical procedure in microgravity using an animal model is described. The investigation resulted in a realistic evaluation of prototype hardware and procedures that could be applied to a surgical support system on Space Station Freedom. This was especially true for the issue of the management of surgical bleeding, which was observed and studied in microgravity for the first time.


Assuntos
Ambiente Controlado , Gravitação , Voo Espacial , Procedimentos Cirúrgicos Operatórios , Animais , Perda Sanguínea Cirúrgica , Modelos Biológicos , Coelhos , Equipamentos Cirúrgicos , Instrumentos Cirúrgicos
19.
Aviat Space Environ Med ; 63(6): 524-8, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1520223

RESUMO

The likelihood of performing a surgical procedure in space will increase as the Soviet Mir space station is expanded and the Space Station Freedom becomes operational. A review of previous research and hardware development, performed mostly in parabolic flight both in the Soviet Union and the U.S., reveals an interest in surgical chambers to prevent cabin atmosphere contamination. Surgical techniques appear to be no more difficult than in a 1-G environment if a restraint system is used. Minimizing the chances of wound infection from the high particle count spacecraft atmosphere is an additional concern. Additional research is necessary to delineate the clinical significance of these problems and to further develop surgical techniques in microgravity.


Assuntos
Medicina Aeroespacial , Voo Espacial , Procedimentos Cirúrgicos Operatórios , Ausência de Peso , Equipamentos Cirúrgicos , Procedimentos Cirúrgicos Operatórios/métodos
20.
Cutis ; 48(4): 315-8, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1743067

RESUMO

We describe a health care facility to be built and used on an orbiting space station in low Earth orbit. This facility, called the health maintenance facility, is based on and modeled after isolated terrestrial medical facilities. It will provide a phased approach to health care for the crews of Space Station Freedom. This paper presents the capabilities of the health maintenance facility. As Freedom is constructed over the next decade there will be an increase in activities, both construction and scientific. The health maintenance facility will evolve with this process until it is a mature, complete, stand-alone health care facility that establishes a foundation to support interplanetary travel. As our experience in space continues to grow so will the commitment to providing health care.


Assuntos
Instituições de Assistência Ambulatorial/organização & administração , Promoção da Saúde/organização & administração , Voo Espacial , Instituições de Assistência Ambulatorial/normas , Equipamentos e Provisões Hospitalares , Promoção da Saúde/normas , Humanos , Decoração de Interiores e Mobiliário , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...