Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Technol Int ; 26: 261-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26055018

RESUMO

The eLibra® Dynamic Knee Balancing System (Synvasive Technology, Zimmer, Warsaw, IN) is an instrument designed to address the flexion stability during a TKA. It provides an objective measurement of the soft-tissue forces in the two compartments before the final cuts are made, allowing to obtain patient-specific rotational orientation of the femoral component. Between March 2010 and March 2012, the eLibra® system was used during the implantation of 75 TKAs in 75 patients at the author's institution. Preoperative and postoperative clinical assessment were evaluated using the Knee Society Score (KSS) and the Visual Analogical Scale (VAS). Radiographic evaluation was performed with weight-bearing radiographs in antero-posterior and lateral views in order to study the presence of radiolucencies. In a sample of 20 patients, representative of the population studied, the rotation of the femoral component was measured by two independent observers using the C-arm Cone Beam CT scan (XperCT/Allura FD20 angiography system; Philips, Best, Netherlands). At a mean follow-up of 42.3 months (29-54 months), three patients died from causes not related to the surgery. We had one case of aseptic loosening three years after surgery. None of the patients reported complications peri- or postoperatively. Clinical evaluation showed an improvement in KSS scoring, from preoperative means of 48.35 and 47.53 points for clinical and functional aspects, respectively, to postoperative means of 88.03 and 91.2 points, respectively (p<0.001 for both aspects). The current study demonstrates that the use of the eLibra® device is simple and reproducible. It could help surgeons objectively quantify ligament balance and perform soft tissue-guided resection in a reproducible way, resulting in better post-operative stability and reduced complications. The use of the postoperative cone beam computed tomography (CBCT), in a representative sample of patients, revealed a specific and optimal orientation of the femoral component with a mean of 2.18° of external rotation.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia
2.
Orthopedics ; 36(11): 856-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24200429

RESUMO

Accurate soft tissue balancing during total knee arthroplasty has a direct effect on patellofemoral tracking and knee range of motion. Numerous instruments and methods are available to balance knee prostheses. The eLIBRA Dynamic Knee Balancing System (Synvasive Technology, Inc, Reno, Nevada) is an electronic device that establishes femoral component rotation using ligamentous tone. The eLIBRA is an articulating spacer that emulates implant trials before anteroposterior femoral cuts are made to obtain a dynamic gap symmetry.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Aging Clin Exp Res ; 23(2 Suppl): 76-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21970932

RESUMO

The number of elderly people is steadily increasing: in the United States it will increase from 12.9% to 20% in 2030 with respect to the total population. Italy, with UK, Denmark and Sweden are the countries with the largest number of octogenarians (about 4% of the population) and it is estimated that this rate will increase by 300% over the next 50 years. The number of people affected by osteoarthritis will increase significantly and therefore the number of total hip arthroplasties will progressively increase. The success of an implant depends firstly by a flawless surgical technique, a correct and stable implant fixation and an optimal preoperative planning that should consider the bone quality of the patient, in order to choose a proper implant design. Different approaches could be followed to achieve adequate fixation: northern Europe surgeons prefer the cemented implant, instead American orthopedics generally use systems that allow a direct biological osteointegration. Elderly patients often present with multiple local and general problems that could affect significantly the normal course of a prosthetic surgery procedure and its results: they have bone tissue changes that lead to increased bone fragility and, consequently, difficulties to obtain primary stability. Osteoporotic bone is characterized by reduction of bone mass, decrease of cancellous bone trabeculae and by increased porosity of cortical bone. The bone fragility implies a greater risk of iatrogenic intraoperative fractures. Furthermore, difficulties linked to bone stock deficiencies become even more significant in revision surgery, where cortical bone thinning is associated with enlargement of the isthmus thus making more difficult to obtain distal fixation of prosthetic stems. At the moment, the role played by the drugs used for the treatment of osteoporosis during implant osteointegration is still not clearly understood and is still under investigation.


Assuntos
Artroplastia de Quadril , Osso e Ossos/patologia , Prótese de Quadril , Osteoporose/patologia , Fraturas por Osteoporose/prevenção & controle , Idoso , Envelhecimento , Artroplastia de Quadril/métodos , Remodelação Óssea , Substitutos Ósseos , Cimentação , Difosfonatos/uso terapêutico , Humanos , Osseointegração , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...