Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 46(8): 1015-1022, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37142800

RESUMO

PURPOSE: To assess the safety and efficacy of ultrasound-guided percutaneous radiofrequency ablation (RFA) for the treatment of refractory non-nodular hyperthyroidism. METHODS: This was a single-center retrospective study in 9 patients with refractory non-nodular hyperthyroidism (2 males, 7 females; median age, range, 36 years, 14-55 years) who underwent RFA between August 2018 and September 2020. The incidence of post-procedural complications, changes in thyroid volume, thyroid function and the use and dosages of anti-thyroid drugs, were compared pre- and post-RFA. RESULTS: All patients completed the procedure successfully, and no serious complications occurred. Three months after ablation, thyroid volumes were significantly decreased with the mean volumes of the right and left lobes reduced to 45.6% (10.9 ± 2.2 ml/23.9 ± 7.2 ml, p < 0.001) and 50.2% (10.8 ± 7.4 ml/21.5 ± 11.4 ml, p = 0.001) of the volumes within 1 week after ablation. The thyroid function was gradually improved in all patients. At 3 months post-ablation, the levels of FT3 and FT4 were returned to the normal range (FT3, 4.9 ± 1.6 pmol/L vs. 8.7 ± 4.2 pmol/L, p = 0.009; FT4, 13.1 ± 7.2 pmol/L vs. 25.9 ± 12.6 pmol/L, p = 0.038), the TR-Ab level was significantly lower (4.8 ± 3.9 vs. 16.5 ± 16.4 IU/L, p = 0.027), and the TSH level was significantly higher (0.76 ± 0.88 vs. 0.03 ± 0.06, p = 0.031) than that before-ablation. Additionally, three months after RFA, the anti-thyroid medication dosages were reduced to 31.25% compared to baseline (p < 0.01). CONCLUSION: Ultrasound-guided RFA in the treatment of refractory non-nodular hyperthyroidism was safe and effective in this small group of patients with limited follow-up. Further studies with larger cohorts and longer follow-up are needed to validate this potential new application of thyroid thermal ablation.


Assuntos
Ablação por Cateter , Hipertireoidismo , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Masculino , Feminino , Humanos , Adulto , Nódulo da Glândula Tireoide/complicações , Nódulo da Glândula Tireoide/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Radiofrequência/métodos , Hipertireoidismo/diagnóstico por imagem , Hipertireoidismo/cirurgia , Hipertireoidismo/etiologia , Ablação por Cateter/métodos
2.
J Vasc Interv Radiol ; 31(10): 1675-1681, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32948387

RESUMO

PURPOSE: To explore the safety and efficacy of double-needle lavage (DNL) in the treatment of difficult aspiration thyroid cystic nodules. MATERIALS AND METHODS: This single-center, prospective, randomized controlled trial was conducted using 100 thyroid cysts from 100 patients who were treated in our hospital from January 2018 to August 2019. These patients were placed into 2 groups; group A including 40 patients treated with single-needle aspiration (SNA), and group B including 60 patients treated with DNL. The safety and efficacy of these 2 aspiration methods were compared. RESULTS: Ten patients in group A that did not benefit from SNA were transferred to group B. No complication occurred in either group. Notably, DNL showed significantly higher efficacy than SNA. This was evidenced by the higher extraction rate of materials in the capsule (A vs B, 91 ± 6.51% vs 98.45 ± 1.74%, P < .001) and overall nodule volume reduction rate in group B (A vs B, 87.54 ± 7.84% vs 95.62 ± 3.66%, P < .001). In group B, patients who received DNL treatment with 2 needles pointed at the upper and lower extremes of the cystic nodules (B2) exhibited significantly better aspiration effects compared to patients in which the 2 needles were pointed at the same ultrasound plane (B1) (P < .05), especially for patients with maximum diameter of nodules ≥3 cm (P < .01). CONCLUSIONS: DNL treatment could efficiently and safely replace cystic material from thyroid gland. Moreover, our results indicate that DNL treatment in which 2 needles are pointed at the 2 extremes of cystic nodules yields higher efficacy in patients with maximum diameter of nodules ≥3 cm.


Assuntos
Drenagem/métodos , Cisto Mediastínico/terapia , Nódulo da Glândula Tireoide/terapia , Adulto , Idoso , China , Drenagem/efeitos adversos , Drenagem/instrumentação , Feminino , Humanos , Masculino , Cisto Mediastínico/diagnóstico por imagem , Pessoa de Meia-Idade , Agulhas , Estudos Prospectivos , Sucção , Nódulo da Glândula Tireoide/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA