Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Cureus ; 14(4): e24299, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35602817

RESUMO

Background Antimicrobial resistance by bacteria poses a substantial threat to the success in the treatment of acute bacterial skin and skin structure infections (ABSSSI). Levonadifloxacin is a novel benzoquinolizine subclass of quinolone which has a broad spectrum of activity, available in both oral and intravenous formulations for the treatment of skin structure infections caused by Gram-positive pathogens including methicillin-resistant Staphylococcus aureus (MRSA). Patients and methods This prescription event monitoring study captured data of 227 patients receiving levonadifloxacin (oral and/or IV) in a real-world setting to assess the safety and efficacy in the treatment of ABSSSI. Study outcomes were a clinical and microbial success at the end of therapy and safety was assessed based on adverse events reported. Results One hundred and forty patients received IV levonadifloxacin therapy, 76 patients received oral alalevonadifloxacin, and 11 received IV followed by oral therapy. The mean duration of therapy was 7.3 days. Out of 227 patients, MRSA isolates were identified in 79 patients. Clinical success rates with oral, IV, and IV followed by oral levonadifloxacin therapy were 97.3%, 97.8%, and 100% respectively. The overall microbial success rate was 99.2% and only two patients reported two adverse events. Conclusions The excellent safety and efficacy profile of levonadifloxacin on oral and/or intravenous therapy, makes it a desirable treatment modality for management of ABSSSI. Unique features of levonadifloxacin such as availability of both IV and oral form, minimal drug-drug interactions, exemption from dosage adjustment in renal and hepatic impaired patients and a broad spectrum of coverage, makes it a suitable agent meeting several unmet clinical needs in contemporary patients.

2.
J Matern Fetal Neonatal Med ; 35(25): 9078-9085, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35099350

RESUMO

OBJECTIVES: To calculate the accuracy (A) and establish the best cutoff value for ophthalmic artery (OA) Doppler velocimetry indexes in patients diagnosed with preeclampsia (PE), compared with healthy pregnant women. METHODS: This prospective experimental study enrolled 268 women: 133 with PE and 135 healthy pregnant women. All patients were evaluated by OA Doppler sonography, bilaterally, to assess their pulsatility index (PI), resistance index (RI), peak systolic velocity (PVS), second peak systolic velocity (P2), end-diastolic velocity (EDV), and peak ratio (PR). Means were compared using Student's T-test. Receiver Operating Characteristics (ROC) curve was used to establish the cutoff value and estimate the sensitivity (S), specificity (Sp), accuracy (A) of all variables, and a significance of 95% was adopted. RESULTS: ROC curve analysis showed that P2 and PR were superior to the other parameters for PE diagnosis. We tested two cutoff values: (1) using PR ≥0.70, obtained A: 88.72%, S: 81.95%, and Sp: 95.48% and (2) using PR ≥0.75, and A: 86.24%, S: 74.43%, and Sp: 99.24%. By adopting P2 ≥ 21.5 cm/s, we obtained A: 87.59%, S: 84.96%, and Sp: 90.22% and when the cutoff point was P2 ≥ 22 cm/s, there was a slight decrease in A to 86.46% and S to 81.20%, with Sp: 91.89.3%. CONCLUSION: Ophthalmic artery Doppler demonstrated to be an effective and high-performance imaging method for the diagnosis of PE and the indexes P2 and PR demonstrated superior accuracy to the other Doppler parameters assessed. Higher performance occurred when the cutoff values with greater specificity were adopted, PR ≥ 0.75 and P2 ≥ 22 cm/s, considering that the proposed OA Doppler is to be a complementary method for preeclampsia.


Assuntos
Artéria Oftálmica , Pré-Eclâmpsia , Feminino , Humanos , Gravidez , Artéria Oftálmica/diagnóstico por imagem , Pré-Eclâmpsia/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia Doppler/métodos , Reologia/métodos , Velocidade do Fluxo Sanguíneo
3.
Vet J ; 267: 105577, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33375961

RESUMO

Left atrial (LA) speckle tracking echocardiography (STE) provides indices of LA deformation such as strain and strain rate. These variables offer useful clinical information in human and canine patients with cardiac disease. At present, reference ranges for LA STE variables in dogs are scarcely established and, due to variability among centers, they cannot be accepted worldwide. The present study aimed to provide normal ranges for LA strain and strain rate variables in clinically healthy dogs, and to evaluate the effect of clinical parameters such as bodyweight. Eighty clinically healthy dogs served as the study population. Left atrial STE was feasible in all dogs and agreement within and between observers was clinically acceptable for most of the variables, in particular strain variables. Age, sex, and heart rate did not affect LA STE. Bodyweight was negatively correlated with strain variables and positively correlated with diastolic strain rate variables and the relationship was allometric. Bodyweight-based vendor-dependent prediction intervals for LA STE variables in clinically healthy dogs could aid the evaluation of LA function in clinical practice.


Assuntos
Função do Átrio Esquerdo , Cães/fisiologia , Ecocardiografia/veterinária , Átrios do Coração/diagnóstico por imagem , Animais , Ecocardiografia/métodos , Feminino , Masculino , Valores de Referência
4.
Sci Rep ; 8(1): 11625, 2018 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-30139960

RESUMO

The ancient harbour of Pisa, Portus Pisanus, was one of Italy's most influential seaports for many centuries. Nonetheless, very little is known about its oldest harbour and the relationships between environmental evolution and the main stages of harbour history. The port complex that ensured Pisa's position as an economic and maritime power progressively shifted westwards by coastal progradation, before the maritime port of Livorno was built in the late 16th century AD. The lost port is, however, described in the early 5th century AD as being "a large, naturally sheltered embayment" that hosted merchant vessels, suggesting an important maritime structure with significant artificial infrastructure to reach the city. Despite its importance, the geographical location of the harbour complex remains controversial and its environmental evolution is unclear. To fill this knowledge gap and furnish accurate palaeoenvironmental information on Portus Pisanus, we used bio- and geosciences. Based on stratigraphic data, the area's relative sea-level history, and long-term environmental dynamics, we established that at ~200 BC, a naturally protected lagoon developed and hosted Portus Pisanus until the 5th century AD. The decline of the protected lagoon started at ~1350 AD and culminated ~1500 AD, after which time the basin was a coastal lake.


Assuntos
Arqueologia/história , Geologia/história , Modelos Biológicos , Paleontologia/história , Ecossistema , Sedimentos Geológicos , História do Século XV , História do Século XVI , História do Século XVII , História Antiga , História Medieval , Itália , Lagos , Biologia Marinha , Região do Mediterrâneo , Mar Mediterrâneo , Dinâmica Populacional
5.
Nucleus (La Habana) ; (63): 19-24, Jan.-June 2018. graf
Artigo em Inglês | LILACS | ID: biblio-990202

RESUMO

Abstract The attention to nuclear clustering has been renewed due to the study of weakly bound nuclei at the drip lines. In particular, clustering structural properties in medium-mass systems have been studied by looking at the competition between the evaporation and pre-equilibrium particle emission in central collisions. Although for light nuclei at an excitation energy close to the particle separation value there are experimental evidence of such structure effects, this is still not the case for heavier systems since the determination of pre-formed clusters within nuclear matter is less obvious. Two systems, leading to the same 81Rb* compound nucleus, have been studied at the same beam velocity 16 AMeV: 16O + 65Cu and 19F + 62Ni. The experiment has been performed using the GARFIELD + RCo detection system installed at the Legnaro National Laboratories.Light charged particles energy distributions and multiplicities have been compared with different statistical and dynamical model calculations. From the first comparison between the two systems a difference in the fast α-decay channel has been evidenced, which can be related to the difference in the projectile structure. Recent data analysis results and comparisons with model calculations are presented in this contribution.


Resumen La atención a la agrupación nuclear se ha renovado debido al estudio de núcleos débilmente unidos en las líneas de goteo. En particular, se han estudiado las propiedades estructurales del agrupamiento en sistemas de masa media al observar la competencia entre la evaporación y la emisión de partículas de preequilibrio en colisiones centrales. Aunque para núcleos ligeros a una energía de excitación cercana al valor de separación de la partícula hay evidencia experimental de tales efectos de estructura, este no es el caso para sistemas más pesados ya que la determinación de agrupamientos preformados dentro de la materia nuclear es menos obvia. Se han estudiado dos sistemas, que conducen al mismo núcleo compuesto 81Rb *, a la misma velocidad de haz 16 AMeV: 16O + 65Cu y 19F + 62Ni. El experimento se ha realizado utilizando el sistema de detección GARFIELD + RCo instalado en los Laboratorios Nacionales Legnaro. Las distribuciones de energía y las multiplicidades de partículas de carga ligera se han comparado con diferentes cálculos de modelos estadísticos y dinámicos. Desde la primera comparación entre los dos sistemas, se ha evidenciado una diferencia en el canal de desintegración α rápida, que se puede relacionar con la diferencia en la estructura del proyectil. En esta contribución se presentan los resultados del análisis de datos recientes y las comparaciones con los cálculos del modelo.

6.
G Ital Med Lav Ergon ; 34(3 Suppl): 595-8, 2012.
Artigo em Italiano | MEDLINE | ID: mdl-23405726

RESUMO

In sanitary field and especially in a hospital, multiple sources of non ionizing radiation are used for diagnostic and therapeutic aims. In sanitary sector both workers and users are present at the same time, and in some cases general population could need higher protection than workers in relationship to the exposition to electromagnetic fields. In order to protect health and safety of patients, general population and workers of hospitals and with the aim to identify, analyze, evaluate and study its level of significance, electrical, magnetic and electromagnetic sources Research Italian project Si.C.E.O. (Safety And Electromagnetic Compatibility In Sanitary Field) was instituted. Target of our research project was to deepen risk of exposition elements with analysis of outdoor (e.g. power lines, transmission cabinets) and indoor (e.g. equipment for physical therapy) sources, located in sanitary structures and to verify the level exposition of workers and common population end the respect of specific regulation, and finally to define technical and organizational measures really useful for protection and reduction of risk.


Assuntos
Fenômenos Eletromagnéticos , Setor de Assistência à Saúde , Exposição Ocupacional , Saúde Ocupacional , Humanos
7.
Pediatr Med Chir ; 29(5): 270-2, 2007.
Artigo em Italiano | MEDLINE | ID: mdl-18402397
8.
J Phys Chem B ; 110(36): 17798-805, 2006 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-16956265

RESUMO

Pure and doped Ba(6)Ti(2)Nb(8)O(30) (BTN), obtained by substituting M = Cr, Mn, or Fe on the Ti site (Ba(6)Ti(2-x) M(x)Nb(8)O(30), x = 0.06 and 0.18) and Y and Fe on the Ba and Ti sites, respectively (Ba(6-x)Y(x)Ti(2-x)Fe(x)Nb(8)O(30), x= 0.18), are synthesized. The influence of cation doping on the local structure, the cation oxidation state, and the possible defect formation able to maintain the charge neutrality are investigated by spectroscopic (electron paramagnetic resonance (EPR) and micro-Raman), structural (X-ray powder diffraction) and transport (impedance spectroscopy, thermoelectric power) measurements, in the temperature range of 300-1200 K in air and N(2) flow. Starting from the valence state of the doping ions (Fe(3+), Cr(3+), and Mn(2+)), determined by EPR, and from thermoelectric power measurements, evidencing a negative charge transport, different charge-compensating defect equilibria, based on the creation of positive electron holes or oxygen vacancies and electrons, are discussed to interpret the conductivity results.

9.
J Phys Chem B ; 110(11): 5409-15, 2006 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-16539476

RESUMO

The room temperature cation occupancy in LiMgVO(4) and LiZnVO(4) crystallographic sites is obtained by means of the combined use of X-ray powder diffraction (XRPD), (7)Li and (51)V magic angle spinning nuclear magnetic resonance (MAS NMR), and micro-Raman measurements. In the LiMgVO(4) Cmcm orthorhombic structure, the 4c (C(2)(v) symmetry) tetrahedral vanadium site is fully ordered; on the contrary, the Li 4c tetrahedral site and the 4b (C(2)(h) symmetry) Mg octahedral site display about 22% of reciprocal cationic exchange. Higher cationic disorder is observed in LiZnVO(4): the three cations can distribute on the three tetrahedral and distinct sites of the R-3 structure. XRPD and MAS NMR analysis results highly agree for what concerns vanadium ion distribution on the three cationic sites (about 25, 26, and 47%). From the full profile fitting of XRPD patterns with the Rietveld method, it is also obtained that Li(+) displays a slightly preferred occupation of the T1 position (approximately 55%) and Zn(2+) of the T2 position (approximately 46%). The vibrational spectra of the two compounds are characterized by different peak positions and broadening of the Raman modes, reflecting the cation distribution and the local vibrational unit distortion. A comparison is also made with recent Raman results on Li(3)VO(4). High temperature XRPD measurements rule out possible structural transitions up to 673 K for both compounds.

10.
Pediatr Cardiol ; 26(4): 467-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16374700

RESUMO

We report a rare case of tetralogy of Fallot with total anomalous pulmonary venous return, left heart hypoplasia, right lung hypoplasia, and left ocular-mandibular synchinesia (Marcus-Gunn phenomenon), correctly diagnosed by cardiovascular magnetic resonance imaging and successfully operated by modified Glenn anastomosis.


Assuntos
Anormalidades Múltiplas/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Pneumopatias/diagnóstico , Pulmão/anormalidades , Imageamento por Ressonância Magnética , Veias Pulmonares/anormalidades , Tetralogia de Fallot/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Recém-Nascido , Pneumopatias/congênito
11.
J Phys Chem B ; 109(31): 14845-51, 2005 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-16852879

RESUMO

This study deals with the effects of 5 and 10% chromium additions on the transport and structural properties of Li3VO4. The Cr substitution is easily obtained without impurity phases and does not affect the room- and high-temperature host crystal structure, as evidenced by X-ray powder diffraction and micro-Raman analysis. The EPR signals are interpreted in terms of quantified amounts of Cr ions in 5+ and 3+ valence states. Suitable 7Li and 51V MAS NMR spectra simulations agree with the EPR results about the relative amount of Cr5+ and Cr3+ ions substituted in V5+ and Li+ sites, respectively. The Cr3+ presence on Li site, also suggested by Raman results and Rietveld refinements, requires Li vacancies to maintain the charge neutrality. The p-type conductivity, suggested by the positive thermoelectric power coefficients, significantly increases by the cation doping up to an order of magnitude.

12.
Phys Rev Lett ; 93(23): 232701, 2004 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-15601152

RESUMO

Peripheral and semiperipheral collisions have been studied in the system 93Nb+93Nb at 38A MeV. The evaporative and midvelocity components of the light charged particle and intermediate mass fragment emissions have been carefully disentangled. In this way it was possible to obtain the average amount not only of charge and mass, but also of energy, pertaining to the midvelocity emission, as a function of an impact parameter estimator. This emission has a very important role in the overall balance of the reaction, as it accounts for a large fraction of the emitted mass and for more than half of the dissipated energy. As such, it may give precious clues on the microscopic mechanism of energy transport from the interaction zone toward the target and projectile remnants.

13.
Clin Cardiol ; 27(11): 611-4, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15562930

RESUMO

BACKGROUND: The Senning operation for transposition of the great arteries (TGA) was first introduced by Senning in 1959 and was revived by Quaegebeur et al. in the late 1970s, thus becoming the intervention of choice for the correction of TGA in many centers. HYPOTHESIS: The purpose of this study was to evaluate the long-term follow-up of a group of patients undergoing surgery with the Senning procedure for TGA. METHODS: From November 1978 to November 1987, 73 consecutive patients underwent the Senning operation. The 70 survivors had an average follow-up of 19 years (16-25 years). RESULTS: (1) Cardiac rhythm: with time there was a progressive decrease in stable sinus rhythm (60% after 20 years) and a progressive increase of supraventricular tachyarrhythmias requiring therapy (10% after 20 years). (2) Right ventricular function: 20% of the patients had reduced ejection fraction. (3) Late mortality: in the last 12 years of follow-up years there were two sudden deaths (2.8%). (4) Functional status: 80% of patients were in NYHA class I, 17% in class II, and 3% in class III. CONCLUSIONS: Our results confirm that the patients who undergo the Senning procedure have a progressive loss of sinus rhythm, an increase in active arrhythmias, and other important adverse outcomes such as late sudden death and a decrease in right ventricular function; however, most patients (93% in our series) are alive and in good functional status.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Transposição dos Grandes Vasos/cirurgia , Resultado do Tratamento , Adolescente , Adulto , Arritmias Cardíacas/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Morte Súbita Cardíaca , Progressão da Doença , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo
14.
Pediatr Surg Int ; 19(1-2): 40-3, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12721721

RESUMO

Dysphagia, gastroesophageal reflux (GER) and esophageal metaplasia are reported with various incidence in the long term follow-up of patients treated at birth for esophageal atresia (EA). To evaluate the long term outcomes 26 patients treated at birth for EA with Tracheo Esophageal Fistula (TEF) were examined 8-28 (mean 15.8) years later by clinical evaluation, including barium meal, fiberoptic upper GI endoscopy, 24 hour ambulatory two-channel pH-monitoring and stationary esophageal manometry. 50% of patients complained of dysphagia. Mild esophagitis was found in 20% of patients but GER was detected in only 16.7% of the cases. By morphological X-ray, esophageal anomalies were detected in 31% of cases without significant functional relevance. Hundred percent of patients had a disorganized peristaltic esophageal activity and a low amplitude of the esophageal contractions was observed in 58% of them. In our series, esophageal dismotilty seems to be the main consequence of EA without any relevant disturbance of normal nutritional habit.


Assuntos
Atresia Esofágica/fisiopatologia , Atresia Esofágica/cirurgia , Adolescente , Adulto , Criança , Transtornos de Deglutição/epidemiologia , Transtornos de Deglutição/fisiopatologia , Dispepsia/epidemiologia , Dispepsia/fisiopatologia , Esofagite/epidemiologia , Esofagite/fisiopatologia , Feminino , Refluxo Gastroesofágico/epidemiologia , Refluxo Gastroesofágico/fisiopatologia , Humanos , Estudos Longitudinais , Masculino , Manometria , Prevalência , Fístula Traqueoesofágica/epidemiologia , Fístula Traqueoesofágica/fisiopatologia
16.
Phys Rev Lett ; 88(5): 052701, 2002 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-11863718

RESUMO

The emission pattern in the v(perp)-v(par) plane of intermediate mass fragments with Z = 3--7 (IMF) has been studied in the collision 116Sn+ 93Nb at 29.5A MeV as a function of the total kinetic energy loss of the reaction. This pattern shows that for peripheral reactions most IMF's are emitted at velocities intermediate between those of the projectile- and target-like products. Coulomb trajectory calculations show that these IMF's are produced in the interaction zone in a short time interval at the end of the target-projectile interaction.

17.
J Pharm Sci ; 90(8): 1154-63, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11536220

RESUMO

The polymorphism of rac-5,6-diisobutyryloxy-2-methylamino-1,2,3,4-tetrahydro-naphthalene hydrochloride (CHF 1035) was investigated. Three different crystal forms (Form I, Form II, and Form III) were obtained by recrystallization procedures from common organic solvents. The polymorphs were characterized by Raman and carbon-13 nuclear magnetic resonance ((13)C NMR) spectroscopy, in solution and in solid state (cross polarization-magic angle spinning), powder X-ray diffractometry, and thermal methods (differential scanning calorimetry, hot stage microscopy, and thermogravimetry). Moreover, the diffraction patterns of Form I, collected at controlled temperatures, gave evidence of the presence of two reversible structural rearrangements at approximately 60 and approximately 75 degrees C. These structural variations were confirmed by the results obtained by differential scanning calorimetry and hot stage microscopy techniques. The analysis of the Raman spectra allowed the identification of peculiar absorption bands for each polymorph. Form III was the stable crystal form at room temperature as determined by the basis of slurry conversion method.


Assuntos
Ésteres , Naftalenos/química , Tetra-Hidronaftalenos , Varredura Diferencial de Calorimetria , Cristalização , Espectroscopia de Ressonância Magnética , Análise Espectral Raman , Difração de Raios X
18.
Minerva Chir ; 56(1): 93-5, 2001 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-11283485

RESUMO

The authors report the case of a female patient suffering from colic neoplasm and a vast peristomal laparocele, the long-term outcome of a rectal amputation that the patient underwent at a young age. After colic resection, a vast area of surgical mesh in dacron was modelled and positioned in a retromuscular scat, thus allowing the hernia pathology to be resolved relatively simply, owing to its particular location-in correspondence with a preternatural anus-until not long ago this would have represented an absolute contraindication to the use of prosthetic materials. A precise surgical approach, marked by a scrupulous respect for aseptic conditions, is essential in these circumstances owing to the persistent risk of septic complications.


Assuntos
Colostomia/efeitos adversos , Hérnia Ventral/etiologia , Hérnia Ventral/cirurgia , Telas Cirúrgicas , Idoso , Feminino , Humanos
19.
Ital Heart J ; 2(2): 115-8, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11256538

RESUMO

BACKGROUND: About 50% of patients with cryptogenic stroke have a patent foramen ovale (PFO). The recurrence rate of paradoxical embolism is higher if a PFO is detected. METHODS: Thirty-five patients with PFO and > or = 1 thromboembolic event due to paradoxical embolism were included in the study (23 males, 12 females, mean age 47.8 +/- 14 years, mean weight 75 +/- 15 kg). Twenty-three patients had a transient ischemic attack whereas 12 experienced an ischemic stroke. Twenty-nine patients had one thromboembolic event, 4 patients had two thromboembolic events, and 2 patients had three thromboembolic events. The implantation procedure was performed, as previously reported, under general anesthesia, fluoroscopic guidance and during transesophageal echocardiography. RESULTS: The implantation procedure was successful in all patients. There were no complications related to the procedure. Four different devices were implanted (Amplatzer 3 patients; Cardioseal 12 patients; Starflex 12 patients, PFO Star 8 patients). The procedure time and fluoroscopic time were 50 +/- 21.8 and 12.2 +/- 8.3 min respectively. At transesophageal echocardiography performed after the procedure, 11 patients had a trivial shunt. None of the patients had a residual shunt at 1 month of follow-up. The mean follow-up was 12.3 +/- 8 months (median 11.0 months, range 3-37 months). In no patient did recurrence of a thromboembolic event occur during follow-up. CONCLUSIONS: Percutaneous PFO closure is a feasible and safe technique for the prevention of recurrent paradoxical embolism.


Assuntos
Embolia Paradoxal/prevenção & controle , Comunicação Interatrial/cirurgia , Próteses e Implantes , Adulto , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Embolia Paradoxal/etiologia , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
20.
Radiat Prot Dosimetry ; 97(4): 395-400, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11878427

RESUMO

The development of EMF monitoring and control systems unquestionably represents one of the major innovations in the range of methodologies for evaluating, through measurement, the so-called environmental electromagnetic pollution. The interest recently shown by ARPA and municipal and provincial councils for setting up electromagnetic field monitoring and control systems has created significant developments in the field under examination. This paper attempts to provide a complete overview of the technical possibilities provided by electromagnetic field monitoring and control systems in the environment and their possible applications. Equipment currently available and under development is described, as well as the most significant work-in-progress in this sector. In the near future, several monitoring systems will be proposed and set up by municipalities and provinces, or directly by telecommunications companies. For this reason, it is more than ever necessary that agreement be reached at a national level to define a unified methodological and operating approach to enable monitoring data from different sources to be compared.


Assuntos
Campos Eletromagnéticos , Monitoramento Ambiental/métodos , Exposição Ambiental/análise , Poluição Ambiental , Humanos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...