1.
Oper Neurosurg (Hagerstown) ; 25(3): 242-250, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37441801

RESUMO

BACKGROUND: Chronic entrapment neuropathy results in a clinical syndrome ranging from mild pain to debilitating atrophy. There remains a lack of objective metrics that quantify nerve dysfunction and guide surgical decision-making. Mechanomyography (MMG) reflects mechanical motor activity after stimulation of neuromuscular tissue and may indicate underlying nerve dysfunction. OBJECTIVE: To evaluate the role of MMG as a surgical adjunct in treating chronic entrapment neuropathies. METHODS: Patients 18 years or older with cubital tunnel syndrome (n = 8) and common peroneal neuropathy (n = 15) were enrolled. Surgical decompression of entrapped nerves was performed with intraoperative MMG of the hypothenar and tibialis anterior muscles. MMG stimulus thresholds (MMG-st) were correlated with compound muscle action potential (CMAP), motor nerve conduction velocity, baseline functional status, and clinical outcomes. RESULTS: After nerve decompression, MMG-st significantly reduced, the mean reduction of 0.5 mA (95% CI: 0.3-0.7, P < .001). On bivariate analysis, MMG-st exhibited significant negative correlation with common peroneal nerve CMAP ( P < .05), but no association with ulnar nerve CMAP and motor nerve conduction velocity. On preoperative electrodiagnosis, 60% of nerves had axonal loss and 40% had conduction block. The MMG-st was higher in the nerves with axonal loss as compared with the nerves with conduction block. MMG-st was negatively correlated with preoperative hand strength (grip/pinch) and foot-dorsiflexion/toe-extension strength ( P < .05). At the final visit, MMG-st significantly correlated with pain, PROMIS-10 physical function, and Oswestry Disability Index ( P < .05). CONCLUSION: MMG-st may serve as a surgical adjunct indicating axonal integrity in chronic entrapment neuropathies which may aid in clinical decision-making and prognostication of functional outcomes.


Assuntos
Síndrome do Túnel Ulnar , Condução Nervosa , Humanos , Condução Nervosa/fisiologia , Nervo Ulnar/cirurgia , Síndrome do Túnel Ulnar/diagnóstico , Síndrome do Túnel Ulnar/cirurgia , Músculo Esquelético , Dor
2.
Muscle Nerve ; 67(3): 244-251, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36533970

RESUMO

INTRODUCTION/AIMS: Although therapeutic electrical stimulation (TES) of injured peripheral nerve promotes axon regeneration and functional recovery, clinical applications of this therapy are limited to the intraoperative timeframe. Implantable, thin-film wireless nerve stimulators offer a potential solution to this problem by enabling delivery of electrical stimuli to an injured nerve over a period of several days post-surgery. The aim of this study was to determine the optimal time course of stimulation for maximizing functional recovery in a rat sciatic nerve isograft repair model. METHODS: Adult male Lewis rats underwent thin-film wireless nerve stimulator implantation following sciatic nerve transection and 40 mm nerve isograft repair. Immediately after surgery, animals began a daily regimen of TES for up to 12 consecutive days. Functional recovery was assessed by compound muscle action potential (CMAP), evoked muscle force, wet muscle mass, and axon counting. RESULTS: Serial CMAP measurements increased in amplitude over the course of the study, yet no significant difference between cohorts for serial or terminal CMAPs was observed. Axon counts and wet muscle mass measurements were greatest in the 6-day stimulation group, which correlated with a significant increase in evoked muscle force for the 6-day stimulation group at the terminal time point. DISCUSSION: Six daily sessions of TES were found to be most effective for augmenting functional recovery compared to other time courses of stimulation. Future studies should incorporate additional subjects and track axonal sprouting or measure neurotrophin levels during the therapeutic window to further elucidate the mechanisms behind, and ideal amount of, TES.


Assuntos
Terapia por Estimulação Elétrica , Músculo Esquelético , Ratos , Masculino , Animais , Músculo Esquelético/fisiologia , Axônios , Isoenxertos , Regeneração Nervosa/fisiologia , Ratos Endogâmicos Lew , Nervo Isquiático/cirurgia , Recuperação de Função Fisiológica/fisiologia , Estimulação Elétrica
3.
J Neurosci Methods ; 371: 109528, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35182605

RESUMO

BACKGROUND: Rodent behavioral models with an electrophysiological component may require the joint operation of hardware from Med Associates, Inc. (St. Albans, VT) and Tucker-Davis Technologies (TDT; Alachua, FL). Although these manufacturers do produce supplemental hardware for interfacing with each other, investing in such hardware may be untenable for research groups with limited funds who wish to use equipment already in their possession. NEW METHOD: We designed a printed circuit board (PCB) in KiCad and had it fabricated by Advanced Circuits (Aurora, CO), with components sourced from Digi-Key (Thief River Falls, MN). The PCB provided 8 channels of bidirectional communication for the transmission of signals between Med Associates' SG-716B SmartCtrl connection panel and TDT's RZ5D base station. This setup enabled the coordinated operation of programs running separately on each set of hardware. RESULTS: The custom-built PCB facilitated the joint operation of Med Associates and TDT hardware in a go/no-go detection task involving rats with electrical implants in their sciatic nerves. COMPARISON WITH EXISTING METHODS: Conventional methods for interfacing Med Associates and Tucker-Davis Technologies rely on the purchase of pre-built hardware whose costs can add up to thousands of dollars. The present method offers a viable alternative that is easily implemented and considerably less expensive (below $200). CONCLUSION: The present approach provides an inexpensive yet effective alternative to far more costly interfacing solutions offered by Med Associates and Tucker-Davis Technologies.


Assuntos
Computadores , Roedores , Animais , Fenômenos Eletrofisiológicos , Próteses e Implantes , Ratos , Nervo Isquiático
4.
Front Neurosci ; 15: 758427, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34690689

RESUMO

Objective: Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees' truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE's implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE's suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present in vivo study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Approach: Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. Main Results: For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 µA (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve's center were, on average, half those of leads located near the periphery (54.92 µA vs. 110.71 µA, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads' thresholds decreased or remained stable over the 3-week span. The remaining two leads' thresholds increased by 70-74%, possibly due to scarring or device failure. Significance: This work represents an important first step in establishing the MSE's viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms.

5.
Cureus ; 13(3): e13728, 2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33842107

RESUMO

Background and objective High-frequency alternating current (HFAC) can yield a rapid-acting and reversible nerve conduction block. The present study aimed to demonstrate the successful implementation of HFAC block delivery via regenerative macro-sieve electrodes (MSEs). Methods Dual-electrode assemblies in two configurations [dual macro-sieve electrode-1 (DMSE-I), DMSE-II] were fabricated from pairs of MSEs and implanted in the transected and subsequently repaired sciatic nerves of two male Lewis rats. After four months of postoperative nerve regeneration through the MSEs' transit zones, the efficacy of acute HFAC block was tested for both configurations. Frequencies ranging from 10 kHz to 42 kHz, and stimulus amplitudes with peak-to-peak voltages ranging from 2 V to 20 V were tested. Evoked muscle force measurement was used to quantify the nerve conduction block. Results HFAC stimulation delivered via DMSE assemblies obtained a complete block at frequencies of 14 to 26 kHz and stimulus amplitudes of 12 to 20 V p-p. The threshold voltage for the complete block showed an approximately linear dependence on frequency. The threshold voltage for the partial conduction block was also approximately linear. For those frequencies that displayed both partial and complete block, the partial block thresholds were consistently lower. Conclusion This study provides a proof of concept that regenerative MSEs can achieve complete and reversible conduction block via HFAC stimulation of regenerated nerve tissue. A chronically interfaced DMSE assembly may thereby facilitate the inactivation of targeted nerves in cases wherein pathologic neuronal hyperactivity is involved.

6.
Nat Med ; 24(12): 1830-1836, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30297910

RESUMO

Peripheral nerve injuries represent a significant problem in public health, constituting 2-5% of all trauma cases1. For severe nerve injuries, even advanced forms of clinical intervention often lead to incomplete and unsatisfactory motor and/or sensory function2. Numerous studies report the potential of pharmacological approaches (for example, growth factors, immunosuppressants) to accelerate and enhance nerve regeneration in rodent models3-10. Unfortunately, few have had a positive impact in clinical practice. Direct intraoperative electrical stimulation of injured nerve tissue proximal to the site of repair has been demonstrated to enhance and accelerate functional recovery11,12, suggesting a novel nonpharmacological, bioelectric form of therapy that could complement existing surgical approaches. A significant limitation of this technique is that existing protocols are constrained to intraoperative use and limited therapeutic benefits13. Herein we introduce (i) a platform for wireless, programmable electrical peripheral nerve stimulation, built with a collection of circuit elements and substrates that are entirely bioresorbable and biocompatible, and (ii) the first reported demonstration of enhanced neuroregeneration and functional recovery in rodent models as a result of multiple episodes of electrical stimulation of injured nervous tissue.


Assuntos
Estimulação Elétrica/métodos , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Cicatrização/fisiologia , Implantes Absorvíveis/normas , Estimulação Elétrica/instrumentação , Humanos , Traumatismos dos Nervos Periféricos/fisiopatologia , Recuperação de Função Fisiológica , Tecnologia sem Fio
7.
Neural Regen Res ; 12(6): 906-909, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28761419

RESUMO

Macro-sieve electrodes were implanted in the sciatic nerve of five adult male Lewis rats following spinal cord injury to assess the ability of the macro-sieve electrode to interface regenerated peripheral nerve fibers post-spinal cord injury. Each spinal cord injury was performed via right lateral hemisection of the cord at the T9-10 site. Five months post-implantation, the ability of the macro-sieve electrode to interface the regenerated nerve was assessed by stimulating through the macro-sieve electrode and recording both electromyography signals and evoked muscle force from distal musculature. Electromyography measurements were recorded from the tibialis anterior and gastrocnemius muscles, while evoked muscle force measurements were recorded from the tibialis anterior, extensor digitorum longus, and gastrocnemius muscles. The macro-sieve electrode and regenerated sciatic nerve were then explanted for histological evaluation. Successful sciatic nerve regeneration across the macro-sieve electrode interface following spinal cord injury was seen in all five animals. Recorded electromyography signals and muscle force recordings obtained through macro-sieve electrode stimulation confirm the ability of the macro-sieve electrode to successfully recruit distal musculature in this injury model. Taken together, these results demonstrate the macro-sieve electrode as a viable interface for peripheral nerve stimulation in the context of spinal cord injury.