1.
Comput Toxicol ; 202021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35368437

RESUMO

Historically, identifying carcinogens has relied primarily on tumor studies in rodents, which require enormous resources in both money and time. In silico models have been developed for predicting rodent carcinogens but have not yet found general regulatory acceptance, in part due to the lack of a generally accepted protocol for performing such an assessment as well as limitations in predictive performance and scope. There remains a need for additional, improved in silico carcinogenicity models, especially ones that are more human-relevant, for use in research and regulatory decision-making. As part of an international effort to develop in silico toxicological protocols, a consortium of toxicologists, computational scientists, and regulatory scientists across several industries and governmental agencies evaluated the extent to which in silico models exist for each of the recently defined 10 key characteristics (KCs) of carcinogens. This position paper summarizes the current status of in silico tools for the assessment of each KC and identifies the data gaps that need to be addressed before a comprehensive in silico carcinogenicity protocol can be developed for regulatory use.

2.
Toxicol Mech Methods ; 13(1): 39-43, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-20021181

RESUMO

The use of magnetic resonance imaging (MRI) for the measurement of cardiac output parameters in anesthetized adult male beagle dogs has been validated against a widely accepted thermodilution method. Using a multislice cine gradient echo MRI method to acquire images of the entire heart, left ventricular lumen volumes were measured at systole and diastole in seven animals. Cardiac output correlated well (R 2 = 0.88) with thermodilution measurements made in a parallel manner, both before and during acute stimulation with the inotrope dobutamine. In a chronic study of changes in cardiac morphology and function brought about by the antihypertensive minoxidil, MRI reliably detected the expected increases in stroke volume (28%) and cardiac output (58%) resulting from neural reaction to decreased blood pressure. Left ventricular lumen enlarged as well in response to fluid retention and plasma volume increase. Two in four minoxidil-treated animals also developed clear MRI-visible pericardial effusion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...