Phys Rev Lett ; 122(23): 231102, 2019 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-31298875

RESUMO

Planned cryogenic gravitational-wave detectors will require improved coatings with a strain thermal noise reduced by a factor of 25 compared to Advanced LIGO. We present investigations of HfO_{2} doped with SiO_{2} as a new coating material for future detectors. Our measurements show an extinction coefficient of k=6×10^{-6} and a mechanical loss of ϕ=3.8×10^{-4} at 10 K, which is a factor of 2 below that of SiO_{2}, the currently used low refractive-index coating material. These properties make HfO_{2} doped with SiO_{2} ideally suited as a low-index partner material for use with a-Si in the lower part of a multimaterial coating. Based on these results, we present a multimaterial coating design which, for the first time, can simultaneously meet the strict requirements on optical absorption and thermal noise of the cryogenic Einstein Telescope.