Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JBMR Plus ; 7(12): e10807, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38130759

RESUMO

Early detection of osteoporosis using advanced imaging is imperative to the successful treatment and prevention of high morbidity fractures in aging patients. In this preclinical study, we aimed to compare dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT) to quantify bone mineral density (BMD) changes in the sheep lumbar spine. We also aimed to determine the relationship of BMD to microarchitecture in the same animals as an estimate of imaging modality precision. Osteoporosis was induced in 10 ewes via laparoscopic ovariectomy and administration of high-dose corticosteroids. We performed DXA and QCT imaging to measure areal BMD (aBMD) and trabecular volumetric BMD (Tb.vBMD)/cortical vBMD (Ct.vBMD), respectively, at baseline (before ovariectomy) and at 3, 6, 9, and 12 months after ovariectomy. Iliac crest bone biopsies were collected at each time point for micro-computed tomography (microCT) analysis; bone volume fraction (BV/TV), trabecular number (Tb.N), thickness (Tb.Th), and spacing (Tb.Sp) were reported. aBMD and Tb.vBMD both decreased significantly by 3 and 6 months (p < 0.05) compared with baseline, whereas no changes to Ct.vBMD were observed. Combined (Tb. and Ct.) vBMD was significantly correlated with aBMD at all time points (all p < 0.05). Additionally, greater significant correlations were found between BV/TV and Tb.vBMD at all five time points (R 2 = 0.54, 0.57, 0.66, 0.46, and 0.56, respectively) than with aBMD values (R 2 = 0.23, 0.55, 0.41, 0.20, and 0.19, respectively). The higher correlation of microCT values with QCT than with DXA indicates that QCT provides additional detailed information regarding bone mineral density changes in preclinical settings. Because trabecular bone is susceptible to rapid density loss and structural changes during osteoporosis, QCT can capture these subtle changes more precisely than DXA in a large animal preclinical model. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

2.
Am J Sports Med ; 50(13): 3649-3659, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36259712

RESUMO

BACKGROUND: Osteoporosis is an independent risk factor for failure after arthroscopic rotator cuff repair. Since rerupture rates after rotator cuff repair are associated with decreased bone mineral density and bone microarchitecture, adaptations of biomechanical properties of the rotator cuff enthesis in patients with osteoporosis remain unclear. Additionally, the effects of osteogenic therapy carrier drugs used for the treatment of osteoporosis on rotator cuff structure and properties have not been previously documented. PURPOSE: To investigate the changes to soft tissue biomechanics and insertional structure secondary to osteoporosis with and without an osteogenic therapy carrier (ie, modified alendronate). STUDY DESIGN: Controlled laboratory study. METHODS: Biomechanical, histopathological, and microcomputed tomography analyses were performed on 20 shoulders obtained from 10 osteoporotic sheep randomly allocated to modified bisphosphonate (ie, alendronate) or control (ie, osteoporotic without treatment) groups; 6 shoulders from healthy sheep were utilized for comparison purposes. RESULTS: Tendons from the control group exhibited a 57% decrease in undeformed Young modulus as compared with the healthy group (P = .010). Tendons from the modified bisphosphonate treatment group exhibited a 229% increase in initial Young modulus as compared with the control group (P = .010). Marked changes within the tendon insertional organization were noted in both the control and the modified bisphosphonate treatment group samples as evidenced by increased interdigitation of the bone-mineralized fibrocartilaginous junction. The control samples exhibited a markedly paucicellular insertion, whereas the modified bisphosphonate treated tendons exhibited a hypercellular insertional region as compared with the healthy group. Both groups exhibited significantly (P < .01) decreased bone quality underlying the infraspinatus insertion, as evidenced by all microcomputed tomography outcome parameters. CONCLUSION: This work illuminates changes to rotator cuff tendon secondary to osteoporosis. Specifically, it revealed decreased tendon modulus and altered insertional structure in the osteoporotic samples. Secondarily, these data revealed increases in tendon modulus accompanied by increased cellularity within the tendon insertion region after systemic modified bisphosphonate injections. CLINICAL RELEVANCE: Bisphosphonate treatment may have a positive effect on the healing of the enthesis after rotator cuff repair.


Assuntos
Osteoporose , Lesões do Manguito Rotador , Animais , Alendronato , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ovinos , Microtomografia por Raio-X
3.
Front Vet Sci ; 9: 816529, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35187145

RESUMO

Trauma to the soft tissues of the ankle joint distal syndesmosis often leads to syndesmotic instability, resulting in undesired movement of the talus, abnormal pressure distributions, and ultimately arthritis if deterioration progresses without treatment. Historically, syndesmotic injuries have been repaired by placing a screw across the distal syndesmosis to provide rigid fixation to facilitate ligament repair. While rigid syndesmotic screw fixation immobilizes the ligamentous injury between the tibia and fibula to promote healing, the same screws inhibit normal physiologic movement and dorsiflexion. It has been shown that intact screw removal can be beneficial for long-term patient success; however, the exact timing remains an unanswered question that necessitates further investigation, perhaps using animal models. Because of the sparsity of relevant preclinical models, the purpose of this study was to develop a new, more translatable, large animal model that can be used for the investigation of clinical foot and ankle implants. Eight (8) skeletally mature sheep underwent stabilization of the left and right distal carpal bones following transection of the dorsal and interosseous ligaments while the remaining two animals served as un-instrumented controls. Four of the surgically stabilized animals were sacrificed 6 weeks after surgery while the remaining four animals were sacrificed 10 weeks after surgery. Ligamentous healing was evaluated using radiography, histology, histomorphometry, and histopathology. Overall, animals demonstrated a high tolerance to the surgical procedure with minimal complications. Animals sacrificed at 10 weeks post-surgery had a slight trend toward mildly decreased inflammation, decreased necrotic debris, and a slight increase in the healing of the transected ligaments. The overall degree of soft tissue fibrosis/fibrous expansion, including along the dorsal periosteal surfaces/joint capsule of the carpal bones was very similar between both timepoints and often exhibited signs of healing. The findings of this study indicate that the carpometacarpal joint may serve as a viable location for the investigation of human foot and ankle orthopedic devices. Future work may include the investigation of orthopedic foot and ankle medical devices, biologic treatments, and repair techniques in a large animal model capable of providing translational results for human treatment.

4.
J Shoulder Elbow Surg ; 31(4): 832-838, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34582992

RESUMO

BACKGROUND: Electrocautery is a common surgical technique and is often used during shoulder arthroplasty to elevate or transect the subscapularis tendon. The relative amount of tissue damage caused by cautery as opposed to sharp transection is not currently known. The purpose of this study was to examine local tissue damage resulting from electrocautery vs. sharp transection with a scalpel. We hypothesized that the electrosurgical unit would cause higher collateral tissue damage and cell death compared with sharp transection. METHODS: Twelve cadaveric ovine shoulders were randomized to either the electrosurgical or sharp transection group. The infraspinatus tendon was isolated, and a partial-thickness transection was made using either a monopolar electrosurgical device (Bovie) or No. 10 scalpel blade. Tendon explants were then visualized with confocal microscopy to evaluate tissue architecture. A live/dead assay was performed using microscopy imaging analysis software. Comparisons between Bovie and scalpel transection were made using the Mann-Whitney U test, and the cell death percentage at standardized distances from the transection site was compared between groups using a mixed-model analysis. Significance was defined at P < .05. RESULTS: The cellular and tendon fibril architecture was well maintained beyond the scalpel transection site, whereas Bovie transection disrupted the architecture beyond its transection path. The percentage of dead cells in the Bovie group (74.9% ± 31.2%) was significantly higher than that in the scalpel group (27.6% ± 29.9%, P = .0004). Compared with the transection site, the cell death percentage after Bovie transection significantly declined at 2.5 mm whereas that after scalpel transection significantly declined at 1 mm from the transection site. CONCLUSION: There was a significantly higher dead cell percentage in the Bovie transection group, indicating extensive damage beyond the local incision site, compared with sharp transection. Electrosurgical transection of the ovine infraspinatus tendon ex vivo caused higher cell death and greater tissue architecture disruption compared with sharp scalpel transection.


Assuntos
Lesões do Manguito Rotador , Traumatismos dos Tendões , Animais , Eletrocirurgia/métodos , Humanos , Manguito Rotador , Ovinos , Instrumentos Cirúrgicos , Traumatismos dos Tendões/cirurgia
5.
Am J Vet Res ; 80(9): 819-824, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31449447

RESUMO

OBJECTIVE: To compare IV doses of alfaxalone and ketamine needed to facilitate orotracheal intubation and assess effects of each treatment on selected physiologic variables in goats undergoing orthopedic surgery with isoflurane anesthesia. ANIMALS: 18 healthy adult goats. PROCEDURES: Behavior was assessed before and after sedation with midazolam (0.1 mg/kg, IV) for IV catheter placement. Anesthesia was induced with additional midazolam (0.1 mg/kg, IV) and alfaxalone (n = 9) or ketamine (9) at 2 mg/kg, IV, over 30 seconds. An additional dose of alfaxalone or ketamine (1 mg/kg) was given IV if needed for intubation; anesthesia was maintained with isoflurane in oxygen and IV fluids with ketamine (0.5 to 1 mg/kg/h). Direct systolic (SAP), diastolic (DAP), and mean (MAP) arterial blood pressures; heart rate; and respiratory rate were recorded before induction, immediately after intubation, and during surgery. Qualitative anesthetic induction and recovery characteristics were assessed. Variables were compared within and between groups by statistical methods. RESULTS: No preinduction variables differed significantly between groups. Postintubation and 30-minute intraoperative SAP, DAP, and MAP were higher for the ketamine group than for the alfaxalone group; within the alfaxalone group, postintubation SAP, MAP, and respiratory rate prior to mechanical ventilation were lower than respective preinduction values. All alfaxalone-group goats were intubated after 1 dose of the induction agent; 5 of 9 ketamine-group goats required an additional (1-mg/kg) dose. Postoperative recovery was good to excellent for all animals. CONCLUSIONS AND CLINICAL RELEVANCE: Both drugs were suitable for induction of anesthesia after sedation with midazolam, but most goats required higher doses of ketamine to allow intubation. For situations in which alfaxalone administration is appropriate, the potential for decreased arterial blood pressures and respiratory rate should be considered.


Assuntos
Anestesia Intravenosa/veterinária , Anestesia/veterinária , Anestésicos Intravenosos/administração & dosagem , Cabras/cirurgia , Isoflurano/administração & dosagem , Ketamina/administração & dosagem , Pregnanodionas/administração & dosagem , Animais , Feminino , Frequência Cardíaca/efeitos dos fármacos , Midazolam/administração & dosagem , Estudos Prospectivos , Distribuição Aleatória , Taxa Respiratória/efeitos dos fármacos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...