J Med Case Rep ; 13(1): 283, 2019 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-31495337

RESUMO

BACKGROUND: Primary spontaneous pneumothorax is a common disorder occurring in young adults without underlying lung disease. Although tobacco smoking is a well-documented risk factor for spontaneous pneumothorax, an association between electronic cigarette use (that is, vaping) and spontaneous pneumothorax has not been noted. We report a case of spontaneous pneumothoraces correlated with vaping. CASE PRESENTATION: An 18-year-old Caucasian man presented twice with recurrent right-sided spontaneous pneumothoraces within 2 weeks. He reported a history of vaping just prior to both episodes. Diagnostic testing was notable for a right-sided spontaneous pneumothorax on chest X-ray and computed tomography scan. His symptoms improved following insertion of a chest tube and drainage of air on each occasion. In the 2-week follow-up visit for the recurrent episode, he was asymptomatic and reported that he was no longer using electronic cigarettes. CONCLUSIONS: Providers and patients should be aware of the potential risk of spontaneous pneumothorax associated with electronic cigarettes.


Assuntos
Pneumotórax/etiologia , Vaping/efeitos adversos , Adolescente , Tubos Torácicos , Drenagem , Humanos , Masculino , Pneumotórax/terapia , Recidiva
2.
J Cardiovasc Magn Reson ; 13: 16, 2011 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-21375743

RESUMO

BACKGROUND: Myocardial extravascular extracellular volume fraction (Ve) measures quantify diffuse fibrosis not readily detectable by conventional late gadolinium (Gd) enhancement (LGE). Ve measurement requires steady state equilibrium between plasma and interstitial Gd contrast. While a constant infusion produces steady state, it is unclear whether a simple bolus can do the same. Given the relatively slow clearance of Gd, we hypothesized that a bolus technique accurately measures Ve, thus facilitating integration of myocardial fibrosis quantification into cardiovascular magnetic resonance (CMR) workflow routines. Assuming equivalence between techniques, we further hypothesized that Ve measures would be reproducible across scans. METHODS: In 10 volunteers (ages 20-81, median 33 yr, 3 females), we compared serial Ve measures from a single short axis slice from two scans: first, during a constant infusion, and second, 12-50 min after a bolus (0.2 mmol/kg gadoteridol) on another day. Steady state during infusion was defined when serial blood and myocardial T1 data varied <5%. We measured T1 on a 1.5 T Siemens scanner using a single-shot modified Look Locker inversion recovery sequence (MOLLI) with balanced SSFP. To shorten breath hold times, T1 values were measured with a shorter sampling scheme that was validated with spin echo relaxometry (TR = 15 sec) in CuSO4-Agar phantoms. Serial infusion vs. bolus Ve measures (n = 205) from the 10 subjects were compared with generalized estimating equations (GEE) with exchangeable correlation matrices. LGE images were also acquired 12-30 minutes after the bolus. RESULTS: No subject exhibited LGE near the short axis slices where Ve was measured. The Ve range was 19.3-29.2% and 18.4-29.1% by constant infusion and bolus, respectively. In GEE models, serial Ve measures by constant infusion and bolus did not differ significantly (difference = 0.1%, p = 0.38). For both techniques, Ve was strongly related to age (p < 0.01 for both) in GEE models, even after adjusting for heart rate. Both techniques identically sorted older individuals with higher mean Ve values. CONCLUSION: Myocardial Ve can be measured reliably and accurately 12-50 minutes after a simple bolus. Ve measures are also reproducible across CMR scans. Ve estimation can be integrated into CMR workflow easily, which may simplify research applications involving the quantification of myocardial fibrosis.


Assuntos
Meios de Contraste/administração & dosagem , Cardiopatias/diagnóstico , Compostos Heterocíclicos/administração & dosagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Meios de Contraste/farmacocinética , Feminino , Fibrose , Gadolínio , Cardiopatias/patologia , Compostos Heterocíclicos/farmacocinética , Humanos , Infusões Intravenosas , Injeções Intravenosas , Imageamento por Ressonância Magnética/instrumentação , Masculino , Método de Monte Carlo , Compostos Organometálicos/farmacocinética , Pennsylvania , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fluxo de Trabalho , Adulto Jovem