Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 264: 44-52, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38518990

RESUMO

PURPOSE: To compare the refractive accuracy of legacy and new no-history formulas in eyes with previous myopic laser vision correction (M-LVC). DESIGN: Retrospective cohort study. METHODS: Setting: Two academic centers Study Population: 576 eyes (400 patients) with previous M-LVC that underwent cataract surgery between 2019-2023. A SS-OCT biometer was used to obtain biometric measurements, including standard (K), posterior (PK), and total keratometry values (TK). OBSERVATION PROCEDURES: Refractive prediction errors were calculated for 11 no-history formulas: two legacy M-LVC formulas, four new M-LVC formulas using K values only, and five new M-LVC formulas using K with PK or TK. MAIN OUTCOME MEASURES: Heteroscedastic testing was used to evaluate relative formula performance, and formulas were ranked by root mean square error (RMSE). RESULTS: New M-LVC formulas performed better than legacy M-LVC formulas. New M-LVC formulas with PK/TK values performed better than versions without PK/TK values. Among new M-LVC formulas with PK/TK values, EVO 2.0-PK was superior to Hoffer QST-PK (P < 0.005). Among new M-LVC formulas using K only, Pearl DGS-K and EVO 2.0-K were both superior to Hoffer QST-K and Barrett True K NH-K formulas (all P < 0.005). CONCLUSIONS: Surgeons should favor using new no-history post M-LVC formulas over legacy post M-LVC formulas whenever possible. The top-performing M-LVC formulas (EVO 2.0-PK, Pearl DGS-PK, and Barrett True K-TK) utilized posterior corneal power values. Among formulas utilizing K alone, the EVO 2.0-K and Pearl DGS-K performed best.

2.
Int Ophthalmol ; 43(5): 1647-1656, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36229561

RESUMO

PURPOSE: Evaluate effectiveness and safety outcomes for patients treated with canaloplasty and trabeculotomy previously treated with a trabecular microbypass stent (TBS). METHODS: Retrospective, multicenter, IRB approved study. Patients treated with TBS (iStent/iStent inject, Glaukos) and subsequently with OMNI surgical system (OSS) (Sight Sciences). From 5 practices in 5 US states. Open-angle glaucoma (OAG), minimum 3 months follow-up after OSS surgery, Pre-OSS IOP ≥ 17 mmHg on ≥ 1 medication. No glaucoma procedures between TBS and OSS. ENDPOINTS: proportion with ≥ 20% reduction in IOP, IOP between 6 and 18 mmHg, mean IOP, change in IOP, mean number of medications. Adverse events and secondary surgical interventions (SSI). Mann-Whitney rank sum test compared pre-OSS IOP and medications with follow-up. RESULTS: Twenty seven patients. Average age (SD) 72.2 (10.8), 22/27 primary OAG (82%), mean MD - 6.2 (7.0) dB. Mean IOP before OSS 22.3 (4.3) mmHg on 2.2 (1.3) medications. At last follow-up (mean 11 months) IOP was 17.2 mmHg on 1.8 medications, - 5.1 mmHg (- 23%, p < .001), - 0.4 meds (- 18%, p = .193); ≥ 20% IOP reduction (41%), IOP ≤ 18 (56%). Adverse events were non-serious. Hyphema > 1 mm (3, 11%), BCVA decrease (4, 15%), IOP spike (2, 7%). SSI (4, 15%) had higher pre-OSS IOP (23.4 mmHg) and worse MD (- 9.6 dB). CONCLUSION: Patients uncontrolled by medication and a prior TBS would once have been candidates for trabeculectomy and tube shunts. OSS offered a minimally invasive option that provided IOP control and avoidance of traditional surgery for the majority over follow-up averaging 11 months and up to 42 months.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Estudos Retrospectivos , Pressão Intraocular , Resultado do Tratamento , Stents
3.
Clin Ophthalmol ; 16: 2295-2303, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35903750

RESUMO

Purpose: To evaluate short-term outcomes of combined ab interno canaloplasty and trabeculotomy in pseudophakic eyes with open-angle glaucoma. Patients and Methods: Series included all pseudophakic eyes with open-angle glaucoma treated with up to 360° ab interno canaloplasty and up to 360° ab interno trabeculotomy using a purpose-engineered device (OMNI, Sight Sciences Inc). Data collected prior to surgery and out to 6-months postoperative. Surgical success defined as a 20% reduction in intraocular pressure (IOP) without increase in glaucoma medication, or discontinuation of at least one glaucoma medication without increase in IOP. Other primary endpoints included mean IOP and number of glaucoma medications. Results: The study included 67 eyes of 52 patients with a mean age of 76.5 ± 8.9 years. Preoperative mean IOP was 22.1±8.0 mmHg on 2.3±1.4 glaucoma medications. Pressure lowering effects were sustained out to 6 months postoperative with a mean IOP of 15.2±4.9 mmHg (p < 0.001) and mean medication reduction of 0.7±1.4 (p < 0.001). Surgical success rate was 69.8% (30 eyes) and correlated with preoperative IOP. Two patients required a secondary surgical intervention. Conclusion: Combined ab interno canaloplasty and trabeculotomy as a standalone procedure is an effective means of reducing IOP and medication burden in pseudophakic eyes with open-angle glaucoma.

4.
Am J Ophthalmol Case Rep ; 22: 101061, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33718662

RESUMO

PURPOSE: The objective of this series is to report the early post-operative visual outcomes of a novel triple procedure utilizing Descemet membrane endothelial keratoplasty (DMEK) plus light adjustable lens (LAL) in two patients (four eyes). METHODS: Two patients with bilateral, visually significant cataracts and Fuchs' dystrophy were selected for DMEK plus LAL triple procedure. Patient B also exhibited a high amount of preoperative astigmatism. Both patients desired spectacle independence and were initially targeted for monovision with the dominant eye corrected for distance and the nondominant eye corrected for near. Best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), and manifest refraction were recorded at each postoperative appointment and light treatment. RESULTS: In the early post-operative course, Patient A chose to pursue binocular distance correction instead of monovision. This was adjusted for accordingly using the LAL. Following final lock-in, Patient A had a distance UCVA of 20/15 in the right eye (OD) and a distance UCVA of 20/20 in the left eye (OS). Patient B was targeted for monovision. After final lock-in, Patient B had a distance UCVA of 20/15 in the dominant eye (OD) and a near UCVA of Jaeger No. 1+ in the nondominant eye (OS). CONCLUSIONS AND IMPORTANCE: The first reported cases of DMEK plus LAL triple procedures achieved exceptional UCVA at the desired target. The post-operative customizability of the LAL allows for the achievement of excellent refractive outcomes after DMEK, even in patients with significant astigmatism and in patients who change their mind regarding refractive target.

5.
Ophthalmol Ther ; 9(4): 981-992, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32939747

RESUMO

INTRODUCTION: This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting with ocular hypertensive (OHT), glaucoma suspect, and open-angle glaucoma (OAG) subjects. METHODS: This study included nine patients (64 ± 9.0 years, nine female) with OHT, glaucoma suspect, or mild OAG. One eye of each subject was randomized to receive negative periocular pressure, while the contralateral eye served as the intrasubject control through the goggle without negative pressure. The Diopsys High Contrast Sensitivity ss-pERG protocol was conducted on both eyes of each subject while wearing the MPD device. Application of negative periocular pressure was set at 50% of baseline intraocular pressure for each study eye. RESULTS: Following 2 h of negative periocular pressure application, the difference in MagnitudeD (MagD) from baseline for eyes randomized to receive negative periocular pressure (+ 0.17 versus - 0.26) was statistically significant (p = 0.023). Over the same period, the change in MagD/Magnitude (MagD/Mag ratio) from baseline for eyes randomized to receive negative periocular pressure was also higher (+ 0.14 versus - 0.16), compared to the control eyes, approached significance (p = 0.059). CONCLUSIONS: Following 2 h of MPD wear, the measured MagD and MagD/Mag ratio improved compared to control, suggesting that negative periocular pressure application to the anterior globe can lead to short-term improvement in one measure of retinal ganglion cell function.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...